1.1 INSTALLATION
RECOMMENDATIONS.
e Zeus Superior kW boiler has been designed
for wall mounted installation only; they must
be used to heat, to produce domestic hot water
and similar purposes. e installation site and
relative Immergas accessories must have suitable
characteristics (both technical and structural),
in order to allow (always in safe, eciency and
easiness conditions):
- installation (according to the legislation and
technical standards in force);
- maintenance operations (including those
scheduled, periodical, ordinary and special);
- removal (to the outdoors in a place suitable
for loading and transporting appliances and
components) as well as any replacement with
equivalent appliances and/or components.
The wall surface must be smooth, without
any protrusions or recesses enabling access
to the rear part. ey are NOT designed to be
installed on plinths or oors (Fig. 1-1).
By varying the type of installation the
classication of the boiler also varies, precisely:
- B22 type boiler if installed using the relevant
terminal for air intake directly from the room
in which the boiler has been installed.
- C type boiler if installed using concentric pipes
or other types of pipes envisioned for the sealed
chamber boiler for intake of air and expulsion
of fumes.
Only professionally enabled companies are
authorised to install Immergas gas appliances.
Installation must be carried out according to the
standards, current legislation and in compliance
with local technical regulations and the required
technical procedures.
Attention: the manufacturer declines all liability
for damages caused by boilers removed from
other systems or for any non-conformities of
such equipment.
Before installing the appliance, ensure that it
is delivered in perfect condition; if in doubt,
contact the supplier immediately. Packing
materials (staples, nails, plastic bags, polystyrene
foam, etc.) constitute a hazard and must be kept
out of the reach of children. If the appliance
is installed inside or between cabinets, ensure
sucient space for normal servicing; therefore
it is advisable to leave clearance of at least 3 cm
between the boiler casing and the vertical sides
of the cabinet.
Leave adequate space above the boiler for
possible water and fume removal connections.
At least 60 cm must be le below the boiler
in order to guarantee replacement of the
magnesium anode.
Keep all flammable objects away from the
appliance (paper, rags, plastic, polystyrene, etc.).
Leave adequate space above the boiler for
possible water and fume removal connections.
At least 60 cm must be le below the boiler
in order to guarantee replacement of the
magnesium anode.
Keep all flammable objects away from the
appliance (paper, rags, plastic, polystyrene, etc.).
Do not place household appliances underneath
the boiler as they could be damaged if the safety
valve intervenes, if the drain trap is blocked, or
if there are leaks from the hydraulic connec-
tions; otherwise, the manufacturer cannot be
held responsible for any damage caused to the
household appliances.
For the aforementioned reasons, we recommend
not placing furnishings, furniture, etc. under
the boiler.
In the event of malfunctions, faults or incorrect
operation, turn the appliance o and contact
an authorised company (e.g. the Authorised
Technical Assistance centre, which has
specically trained sta and original spare parts).
Do not attempt to modify or repair the appliance
alone.
Failure to comply with the above implies personal
responsibility and invalidates the warranty.
• Installation regulations:
- this boiler can be installed outside in a par-
tially protected area. A partially protected
location is one in which the appliance is not
exposed to the direct action of the weather
(rain, snow, hail, etc..).
NOTE: this type of installation is only possible
when permitted by the laws in force in the
appliance’s country of destination.
- Installation in places with a re risk is pro-
hibited (for example: garages, closed parking
stalls), gas appliances and relative ue ducts,
ue exhaust pipes and combustion air intake
pipes.
- Installation is prohibited on the vertical
projection of cooking hobs.
Attention: Wall mounting of the boiler must
guarantee stable and ecient support for the
generator.
The plugs supplied are to be used only in
conjunction with the mounting brackets or xing
template to x the appliance to the wall; they only
ensure adequate supportif inserted correctly
(according to technical standards) in walls made
of solid or semi-hollow brick or block.In the
case of walls made from hollow brick orblock,
partitions with limited static properties, or in any
case walls other than those indicated, a static test
must be carried out to ensure adequate support.
N.B.: the hex head screws supplied in the blister
pack are to be used exclusivelyto x the relative
mounting bracket to the wall.
ese boilers are used to heat water to below
boiling temperature in atmospheric pressure.
ey must be connected to a heating system
and hot water circuit suited to their performance
and capacity.
Anti-Legionella thermal treatment of the Immer-
gas (which can be activated through the specic
function present on the set thermoregulation sys-
tems): during this phase, the water temperature
inside the storage tank exceeds 60 °C resulting in
burns hazards. Keep this DHW treatment under
control (and inform the users), to prevent unex-
pected damage to persons, animals and objects. If
required, a thermostatic valve must be installed
at the DHW outlet to prevent burns.