MAGIS HERCULES PRO 12-14-16
6
2 MAGIS HERCULES PRO 12 14 16 FEATURES SINGLEPHASE OR THREEPHASE
Split inverter reversible single-phase or three-phase air/water heat
pumps, composed of an outdoor condensing unit and an indoor
oor standing unit; a single code identies the complete system.
Main components:
- Outdoor condensing unit (UE AUDAX PRO V2 /
UE AUDAX PRO V2 T) which mainly includes rotary com-
pressor, inverter electronics, throttle valve, 4-way valve for
cycle inversion, nned exchange coil with outdoor air. e
cooling circuit is already preloaded (R410A refrigerant) in the
condensing unit, equipped with the relative shut-o valves;
- Floor standing indoor unit (UI MHP AP), which includes
the hydraulic circuit components for connection to the sys-
tem, as well as the related management and communication
electronics with the condensing unit. e indoor unit can be
divided into 2 parts (with dedicated frame for each individual
unit), to facilitate transportation to the installation rooms; in
particular, it consists of:
•72-plate water / R410A Heat exchanger unit;
•Stainless steel 235 litre domestic hot water storage tank unit,
standard equipped with 2.3 kW DHW (Domestic hot water)
integrative resistance (possible combination of 1 or 2 additional
2.3 kW DHW (Domestic hot water) resistances - optional);
•Stainless steel 45 litre inertial storage tank, which also acts as
a hydraulic manifold;
•3 kW System integrative resistance (optional) - only one or 2
can be installed;
•Hydraulic unit on the Grundfos CHBL UPML 20-105 pri-
mary circuit and 3-way DHW (Domestic hot water) priority
valve, while for the system ow circuits, the zone pumps are
WILO PARA 15-130 8 m (1 standard zone) and WILO
PARA 15-130 9 m (mixed zone 2 kit and mixed zone 3 kit,
both optional; the circuits can operate in heating and cooling
mode); shut-o valves with standard lter on zone 1;
•24 litre system expansion vessel, 16 litre DHW (Domestic hot
water) expansion vessel;
•Electronics including system manager unit (for programming
all generator functions directly from the control panel and
programming the time slots for all circuits and relative climatic
curves, in heating and cooling mode) + power electronics unit
(electrical connection terminal block of the various electrical
devices - e.g. resistances);
•Control panel with control covering door equipped with
opening for the large display; controls composed of 7 keys +
2 encoder knobs to make adjustments;
- e system zones can be managed via:
•Zone remote panel (optional, for zone 1 also), it is possible to
install up to 3, one for each system zone;
•ModBus temperature and humidity sensor kit;
•On-o room chrono-thermostat and on-o humidistat;
•Variable temperature operation, using the external probe on
the condensing unit. Possibility to set 3 heating curves and 3
cooling curves (from control panel); if the condensing unit is
installed in “unfavourable” conditions for detecting the outdoor
temperature, another external probe can be combined (optional);
•BOOST function for DHW (Domestic hot water) - makes it
possible to use all the power available (HP + electrical resist-
ances);
•Inlet to force activation with photovoltaic system that produces
electricity (the DHW storage tank is heated to a maximum
storage temperature exclusively by the heat pump. In case
of simultaneous DHW and system request, the system will
decide which service to satisfy, in order to ensure the best
comfort);•Electrical outputs for dehumidier control;
•230 V output to control summer/winter diverter valves in
heating systems with fan coil cold / radiant panels; switching
occurs with the change of mode (summer/winter);
•Control of Recirculation kit with pump (optional) - pro-
gramming of the activation time slots from control panel +
temperature probe (on the recirculation network return) to
switch o the circulator when the loop is hot;
•Programmable anti-legionella function (with resistance);
•Screed heater function;
•Compared with block heat pumps, the water circuit is fully
protected against freezing because it can be installed inside the
home (important in cold zones);
•Minimum system water content demand of 50 litres for ma-
chines 12-14-16 kW. erefore, the standard supplied thermal
ywheel (45 litres) is practically always sucient.
It is available in the model:
• MAGIS HERCULES PRO 12 code 3.030431
• MAGIS HERCULES PRO 14 code 3.030432
• MAGIS HERCULES PRO 16 code 3.030433
• MAGIS HERCULES PRO 12 T code 3.030434
• MAGIS HERCULES PRO 14 T code 3.030435
• MAGIS HERCULES PRO 16 T code 3.030436
EC Declaration Of Conformity.