1IMPORTANT
RECOMMENDATIONS
1.1 WARNINGS.
is appliance may only be used by
adults Users whose physical, sensory
or mental abilities are not impaired.
Before using this appliance, it is in any
case required to read this instructions
booklet (User section) and/or the op-
erating instructions by skilled technical
personnel.
Use by incompetent adult personnel
let alone by children is forbidden, both
due to safety issues and to issues of cor-
rect appliance operation and warranty.
is appliance has been designed to
serve one residential housing unit only
(and similar) subject to assessment of
the energy requirement for domestic
hot water; it is not a heating system
pursuant to the legislation in force.
1.2 INSTALLATION.
Warning: due to its weight (from 90
to 110 kg depending on the version),
this appliance must be handled with
care to avoid injury to persons or
damage to property and to the prod-
uct itself. Installation must therefore
be performed taking into account the
following instructions:
- Install the appliance in a frost-free
room. e warranty does not cover
any appliance breakdown caused by
excessive pressure due to the safety
valve blocking because of ice.
- Ensure the oor on which the appli-
ance is to be installed is suitable to
withstand the appliance's own weight
and that of the water content (270 li-
tres approximately). It is recommend-
ed to perform a structural assessment
by the designer of the dwelling.
- If the boiler is mounted on a false ceil-
ing, under the roof or above a living
area, it is mandatory to install a drip
tray to be connected to the drain.
- Suitably aerate the installation room
in the event the appliance is to be
installed in a room and/or in a posi-
tion where the ambient temperature
is always higher than 35°C.
- is device is intended for use up to
a maximum height of 3000 m.
- Position the appliance in an accessible
area and at such a distance from the
wall to permit correct maintenance /
accessibility (Parag. 3.1).
- Refer to the installation diagrams
(Parag. 3.1).
Warning: failure to comply with rec-
ommended installation procedures,
especially those related to the room
volume below the minimum of 20
m, may signicantly reduce system
performance.
- It is recommended to provide suita-
ble shut-o valves on the plumbing
coupling to allow for any routine and
extraordinary maintenance opera-
tions which might require emptying
/ lling the boiler.
- In order to prevent any stability and
safety issues, it is obligatory to secure
the boiler to the oor, on a at surface,
using the fastening anchors supplied.
1.3 PLUMBING CONNECTION.
It is mandatory to install a safety device,
set to be triggered at 0.7 MPa (7 bars)
(not supplied with the boiler), sized
3/4”, compliant with standard EN1487
as amended and added, and in any
case compliant with local regulations
in force, to be tted to the cold water
inlet of the boiler.
e safety device must be protected
from ice.
e safety unit must be tted with a
discharge device (overpressure) to
be operated regularly to remove any
limestone deposits.
It must also be checked regularly to
ensure it is not blocked.
e pressure reducer (not supplied as
standard) is required when the water
mains pressure exceeds 0.5 MPa (5
bars) and must be mounted on the
main water supply line.
e safety unit must also be connected
to a drain pipe kept in the open air, in
a frost-free environment, with a per-
manent downward gradient, to remove
any expansion water from the heating
process, or drainage water from the
water-heater.
e maximum operating pressure of
the heat exchanger circuit must not
exceed 0.3 MPa (3 bars) and its max
temperature must not exceed 100°C.
To perform any discharge operations
of the water-heater, strictly adhere to
the following sequence:
- Disconnect the appliance from the
electrical power supply.
- Disconnect the appliance from the
mains water supply (cold water).
- Open the hot water cock.
- Actuate the discharge device of the
safety unit.
1.4 WIRING.
Before removing the cover of the wa-
ter-heater, always ensure the power is
disconnected, to prevent any risk of
injury due to electric shocks.
e following must be provided up-
stream of the electrical installation:
- A thermal magnetic breaker or 16A
multi-pole fuse with contacts compli-
ant with regulations in force.
- A 30 mA dierential circuit breaker.
Should the power supply cable be found
to be damaged for any reason, it must
be replaced by the Aer-sale Support,
or in any case by skilled and qualied
personnel.
e water-heater must be connected to
earth according to the methods set out
by the regulations in force.
A special terminal, suitably marked
is provided for the specic purpose.
is manual is supplied jointly with
the boiler; in the event of loss it may
also be obtained from the Authorised
area Support service or be downloaded
from the suitable website.