Immergas BASIC SOL V2 User manual

V2 HEATING
SOLAR
PANELS
PACKS
IE
Instruction booklet
and warning
*1.041485ENG*


Dear Customer,
Our compliments for having chosen a V2-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas customer
you can also count on a qualied aer-sales service, prepared and updated to guarantee constant eciency of its products.
Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the device, the respect of which, will conrm your
satisfaction for the Immergas product.
For any interventions or routine maintenance contact Authorised Centres: these have original spare parts and boast of specic preparation directly from the
manufacturer.
General recommendations
All Immergas products are protected with suitable transport packaging.
e material must be stored in dry environments protected against bad weather.
e instruction book is an integral and essential part of the product and must be consigned to the new user also in the case of transfer or succession of ownership.
It must be stored with care and consulted carefully, as all of the warnings provide important safety indications for installation, use and maintenance stages.
is instructions manual provides technical information regarding installation of Immergas heating solar panels packs. As for the other issues related to in-
stallation of the said products (e.g. safety in the work site, environment protection, injury prevention), it is necessary to comply with the provisions specied
in the regulations in force and principles of good practice.
In compliance with legislation in force, the systems must be designed by qualied professionals, within the dimensional limits established by the Law. Installation
and maintenance must be performed in compliance with the regulations in force, according to the manufacturer’s instructions and by an authorised company,
which has specic technical expertise in the system sector, as required by Law.
Improper installation or assembly of the Immergas appliance and/or components, accessories, kit and devices can cause unexpected problems to people, animals
and objects. Read the instructions provided with the product carefully to ensure a proper installation.
Maintenance must be carried out by an authorised company. e Authorised Aer-sales Service represents a guarantee of qualication and professionalism.
e appliance must only be destined for the use for which it has been expressly declared. Any other use will be considered improper and therefore potentially
dangerous.
If errors occur during installation, operation and maintenance, due to non compliance with technical laws in force, standards or instructions contained in this
book (or however supplied by the manufacturer), the manufacturer is excluded from any contractual and extra-contractual liability for any damages and the
appliance warranty is invalidated.
e company IMMERGAS S.p.A., with registered oce in via Cisa Ligure 95 42041 Brescello (RE), declares that the design, manufacturing and aer-sales
assistance processes comply with the requirements of standard UNI EN ISO 9001:2008.
For further details on the product CE marking, request a copy of the Declaration of Conformity from the manufacturer, specifying the appliance model
and the language of the country.
e manufacturer declines all liability due to printing or transcription errors, reserving the right to make any modications to its technical and commercial
documents without forewarning.

INDEX
USER pageINSTALLER page MAINTENANCE TECHNICIAN page
1 Device installation ....................................5
1.1 Description of the device. ........................5
1.2 Kit Basic Sol V2.........................................6
1.3 Kit basic Sol Lux V2..................................7
1.4 Stainless Steel Sol 200 V2.........................8
1.5 Stainless Steel Sol 200 Lux V2. ................9
1.6 Stainless Steel Sol 300 V2.......................10
1.7 Stainless Steel Sol 300 Lux V2. ..............11
1.8 Inox Sol 500 V2. ......................................12
1.9 Inox Sol 500 Lux V2................................13
1.10 Solar collectors. .......................................14
1.11 Control devices unit................................16
1.12 Circulation unit.......................................17
1.13 Hydraulic connection
CP4XL at collectors..............................18
1.14 Hydraulic connection
CSV14 vacuum collectors......................19
1.15 Circulation unit
hydraulic connection..............................20
1.16 Assembly instructions. ...........................20
1.17 Commissioning. ......................................21
1.18 Expansion vessel pre-charge..................21
1.19 Safety valve...............................................21
1.20 Filling system...........................................21
2 Decommissioning ...................................22 3 Controls and maintenance.....................23
3.1 Maintenance. ...........................................23
3.2 Annual maintenance methods. .............23

5
INSTALLERUSERMAINTENANCE TECHNICIAN
1DEVICE
INSTALLATION
1.1 DESCRIPTION OF THE DEVICE.
e Immergas solar solutions systems are sup-
plied complete for its commissioning with exclu-
sion of xing systems (e.g. plugs etc.).
e solar collectors are certied and are in com-
pliance with the standards Solarkeymark. ey
can be mounted on all roof types or directly on
the ground by means of an additional appropri-
ate structure.
e purpose of this manual is to give general
indications on its installation and relative use of
the complete system.
Installation must be carried out in compliance
with current regulations and by qualied sta.
Installation must be carried out according to the
standards, current legislation and in compliance
with local technical regulations and the enabled
companies.
In the event the pack is installed in damp places,
one must provide an insulation system under-
neath it, to insulate it from the ground.
e place of installation of the appliance and
relative Immergas accessories must have suitable
features (technical and structural) such to allow
(always in safety, efficiency and comfortable
conditions):
- installation (according to the provisions of the
technical legislation and technical regulations);
- maintenance operations (including scheduled,
periodic, routine and special ones);
- removal (to outdoors in the place for loading
and transporting the appliances and com-
ponents) as well as the eventual replacement
of those with appliances and/or equivalent
components.
Before installing the system, ensure that it is
delivered in perfect condition; if in doubt, con-
tact the supplier immediately. Packing materials
(staples, nails, plastic bags, polystyrene foam,
etc.) constitute a hazard and must be kept out of
the reach of children.
In case of failure to use the solar system or pro-
longed absences, cover the collectors to prevent
overheating of the system.
In the event of malfunctions, faults or incorrect
operation, turn the system o immediately and
cover it; it is also necessary to contact an author-
ised company (e.g. the Authorised Technical
Assistance Centre, which has specically trained
sta and original spare parts). Do not attempt to
modify or repair the appliance alone.Failure to
comply with the above implies personal respon-
sibility and invalidates the warranty.
“Anti-legionella” heat treatment of the Immergas
storage tank (activated by the specic function
present on the predisposed thermoregulatory
systems): during this stage, the temperature of
the water inside the storage tank exceeds 60°C
with a relative risk of burns. Keep this domestic
water treatment under control (and inform
the users) to prevent unforeseeable damage
to people, animals, things. If required install a
thermostatic valve on the domestic hot water
outlet to prevent scalding.
• Installation regulations:
- e control of the entire framework by a statics
expert, according to the Standards in force, is
mostly necessary in areas with large snowfall or
in areas exposed to strong winds. erefore, all
characteristics of the place of assembly must be
taken into consideration (gusts of wind, vortex
build-up, etc...) which can lead to an increase
of loads on the structures.
- before starting the system, the solar collector
must be covered to protect the absorber from
over-heating and the operator from eventual
burns. e system must only be lled when
all hydraulic connections have been coupled
correctly. It cannot be started until it is possible
to eliminate the heat generated by the solar
collector.
- e collector can be positioned on the basis of
the conditions of the roof (at or sloping) or in
a prepared free structure. e collector cannot
be positioned with the glass part facing down.
is causes malfunctioning and damage.
- Pay attention not to force or put excessive
traction on the collector connection ttings in
order to prevent damage tot he same and the
internal parts of the collector.
- During movement, use protective gloves and
do not transport the collector holding it by the
connection ttings.
Attention:
- it is in fact obligatory to use antifreeze supplied
by the manufacturer;
- when realising the hydraulic circuit (pipes,
ttings, etc.), only use suitable materials that
resist high temperatures and are suitable for
use with solar systems.
- the use of a boiler involves the installation of a
safety valve, an expansion vessel and a one-way
valve for the appropriately sized domestic hot
water circuit, these components are not always
included in the package.
N.B.: if errors occur during installation, running
and maintenance, due to the non compliance of
technical laws in force, standards or instructions
contained in this book (or however supplied by
the manufacturer), the manufacturer is excluded
from any contractual and extra-contractual
liability for any damages and the warranty is
invalidated.

6
1-1
1
2
3
4
5
6
7
A
D
E
C
B
8
INSTALLERUSERMAINTENANCE TECHNICIAN
1.2 KIT BASIC SOL V2.
Kit composition.
N°1 at solar collector CP4XL (1)
N°1 electronic control unit (2)
N°1 individual solar circulation unit (3)
N°1 18 l expansion vessel (4)
N°1 6 bar safety valve (5)
N°1 system probe and venting unit (6)
N°1 mixing valve (7)
- frame and brackets for roof installation
Key:
A - Hercules Boiler series (sold separately)
B - Domestic hot water withdrawal
C - Solar panels connection attachments
D - Domestic cold water inlet
E - Domestic hot water outlet

7
1-2
1
2
3
4
5
6
7
A
D
E
C
B
8
INSTALLERUSERMAINTENANCE TECHNICIAN
1.3 KIT BASIC SOL LUX V2.
Kit Composition.
N°1 vacuum solar collector CSV14 (1)
N°1 electronic control unit (2)
N°1 double circulation solar unit (3)
N°1 35 l expansion vessel (4)
N°1 6 bar safety valve (5)
N°1 probe unit and system venting (6)
N°1 mixer valve (7)
- frame and brackets for roof installation
Key:
A - Hercules series boiler (sold separately)
B - Withdrawal of domestic hot water
C - Solar panels connection attachments
D - Domestic cold water inlet
E - Domestic hot water outlet

8
1-3
9
1
2
3
4
5
6
7
A
8
B
10
INSTALLERUSERMAINTENANCE TECHNICIAN
1.4 STAINLESS STEEL SOL 200 V2.
Kit Composition.
N°1 at solar collector CP4XL (1)
N°1 electronic control unit (2)
N°1 single circulation solar unit (3)
N°1 18 l expansion vessel (4)
N°1 6 bar safety valve (5)
N°1 probe unit and system venting (6)
N°1 mixer valve (7)
N°1 200 litre storage tank in stainless steel (8)
N°1 Non-return valve (9)
- frame and brackets for roof installation
Key:
A - Withdrawal of domestic hot water
B - Connection to the boiler

9
1-4
8
B
1
2
3
4
5
6
7
A
9
INSTALLERUSERMAINTENANCE TECHNICIAN
1.5 STAINLESS STEEL SOL 200 LUX V2.
Kit Composition.
N°1 vacuum solar collector CSV14 (1)
N°1 electronic control unit (2)
N°1 double circulation solar unit (3)
N°1 35 l expansion vessel (4)
N°1 6 bar safety valve (5)
N°1 probe unit and system venting (6)
N°1 mixer valve (7)
N°1 200 litre storage tank in stainless steel (8)
- frame and brackets for roof installation
Key:
A - Withdrawal of domestic hot water
B - Connection to the boiler

10
1-5
9
B
1
23
4
5
6
7
A
8
10
INSTALLERUSERMAINTENANCE TECHNICIAN
1.6 STAINLESS STEEL SOL 300 V2.
Kit Composition.
N°2 at solar collectors CP4XL (1)
N°1 electronic control unit (2)
N°1 single circulation solar unit (3)
N°1 18 l expansion vessel (4)
N°1 6 bar safety valve (5)
N°1 probe unit and system venting (6)
N°1 mixer valve (7)
N°1 300 litre storage tank in stainless steel (8)
N°1 Non-return valve (9)
- frame and brackets for roof installation
Key:
A - Withdrawal of domestic hot water
B - Connection to the boiler

11
1-6
A
1
2
3
4
5
6
7
8
B
1
9
INSTALLERUSERMAINTENANCE TECHNICIAN
1.7 STAINLESS STEEL SOL 300 LUX V2.
Kit Composition.
N°2 vacuum solar collectors CSV14 (1)
N°1 electronic control unit (2)
N°1 double circulation solar unit (3)
N°1 35 l expansion vessel (4)
N°1 6 bar safety valve (5)
N°1 probe unit and system venting (6)
N°1 mixer valve (7)
N°1 300 litre storage tank in stainless steel (8)
- frame and brackets for roof installation
Key:
A - Withdrawal of domestic hot water
B - Connection to the boiler

12
1-7
1
23
4
5
6
7
A
8
B
1
9
10
INSTALLERUSERMAINTENANCE TECHNICIAN
1.8 INOX SOL 500 V2.
Kit Composition.
N°4 at solar collectors CP4XL (1)
N°1 electronic control unit (2)
N°1 single circulation solar unit (3)
N°1 35 l expansion vessel (4)
N°1 6 bar safety valve (5)
N°1 probe unit and system venting (6)
N°1 mixer valve (7)
N°1 500 litre storage tank in stainless steel (8)
N°1 Non-return valve (9)
- frame and brackets for roof installation
Key:
A - Withdrawal of domestic hot water
B - Connection to the boiler

13
1-8
1
2
3
4
5
6
7
8
B
A
9
INSTALLERUSERMAINTENANCE TECHNICIAN
1.9 INOX SOL 500 LUX V2.
Kit Composition.
N°3 vacuum solar collectors CSV14 (1)
N°1 electronic control unit (2)
N°1 double circulation solar unit (3)
N°1 80 l expansion vessel (4)
N°1 6 bar safety valve (5)
N°1 probe unit and system venting (6)
N°1 mixer valve (7)
N°1 500 litre storage tank in stainless steel (8)
- frame and brackets for roof installation
Key:
A - Withdrawal of domestic hot water
B - Connection to the boiler

14
1-9
1-10
CP4XL CSV14
INSTALLERUSERMAINTENANCE TECHNICIAN
1.10 SOLAR COLLECTORS.
The installation of a heating solar collector
requires analysis of a range of issues (installa-
tion area, positioning, inclination angle, etc.), of
which depend on the performances the collector
will be able to supply once started.
It is therefore important to contact a an author-
ised company to check the various parameters
installation.
Installation precautions:
- Before installing the collector, proceed with an
installation area check, ensure the installation
of the collector can withstand atmospheric
agents: wind and snow.
- e collector can be positioned based on the
roofs conditions (at or leaning) or in a predis-
posed adjustable structure. Under no circum-
stances can the collector be positioned with the
collector glass facing downwards which is the
cause of the malfunctions and damages.
- before starting the operating system, the solar
collector must be covered to protect the ab-
sorber from overheating and the operator from
scalding. e system must only be lled when
the hydraulic system of the collector has been
assembled and cannot be started before it has
been possible to eliminate the heat generated
from the solar collector.
- Be careful to not force or put the connection
fittings under excessive traction to avoid
damaging them and the internal parts of the
collector.
- During handling use appropriate personal pro-
tective equipment (e.g. gloves etc.) and avoid
transporting the collector from the connection
ttings.
- Provide an appropriate earthing system con-
nection and any lightning and surge protection
systems to safeguard any electric devices. In
the event these systems are already present,
the Immergas solar system must be connected
to the existing lightning protection system by
a qualied rm, in compliance with the legisla-
tion in force, which must issue a declaration of
conformity.
HEAD LOSSES GRAPHICS.
FLAT COLLECTOR VACUUM COLLECTOR
Mass ow rate [kg/h] Mass ow rate [kg/h]
Pressure drop [mbar]
Pressure drop [mbar]

15
INSTALLERUSERMAINTENANCE TECHNICIAN
TECHNICAL FEATURES CP4 XL.
Name Flat Collector
Dimensions (length x height x thickness) mm 1198 x 2150 x 83
Weight of collector(empty) kg 47
Attachment diameter mm Ø 22
Selector inside pipe diameter mm Ø 8
Capacity l1,7
Cover -- Aluminium
Glass Solar, toughened
Glass thickness mm 4
Insulating material Mineral wool
Absorber Highly selective covering
Gross surface m22.52
Solar absorption area m22.31
Maximum stagnation temperature (dry) °C 234
Optical output ratio (according to EN 12975) η0.759
a1 ref. Opening surface W / m2K 3.48
a2 ref. Opening surface W / m2K20.0161
Kθangle incidence 50° 0.95
Heating capacity ceff 5.72
Maximum working pressure bar 10
Average ow l/min 1.25
TECHNICAL FEATURES CSV.
Name Vacuum collector
Dimensions mm 1616 x 1647 x 107
Weight of collector(empty) kg 42
Attachment diameter -- 3/4”
Selector inside pipe diameter mm Ø 8
Capacity l2.30
Cover -- Aluminium
Glass Borosilicate
Insulating material Vacuum chamber
Absorber Aluminium nitrite
Gross surface m22.57
Solar absorption area m22.36
Maximum stagnation temperature (dry) °C 286
Optical output ratio (according to EN 12975) η0.605
a1 ref. Opening surface W / m2K 0.85
a2 ref. Opening surface W / m2K20.010
Kθangle incidence 50° θl50° = 0.92
θt50° = 1.15
Heating capacity ceff 45.94
Maximum working pressure bar 10
Average ow l/min 1.25

16
1-11
1-12
1-13
A
5
1
2
3
4
7
8
6
A
T1
T2
INSTALLERUSERMAINTENANCE TECHNICIAN
1.11 CONTROL DEVICES UNIT.
e control unit manages the solar system by
controlling the solar unit pump. e various
functions can be programmed via the 3 buttons
(Fig. 1-11) positioned under the display.
1 Forward; 2 Reverse; 3 Set (Selection / opera-
tion mode)
e unit (A) activates the pump when a tem-
perature dierence set between the collector
probe (T1) and the boiler probe (T2) (Fig. 1-12).
The installation must only be carried out in
closed and dry environments. To guarantee
regular operation, avoid areas with strong elec-
tromagnetic elds. e regulation control unit
must be detachable from the electric network by
means of an additional device in compliance with
the Laws in force. During installation ensure that
the connection cable to the electric network and
the probe cables remain separated.
e control unit is equipped with 3 relay to which
to connect users such as pumps, valves, etc.
At the time of installation the unit is supplied
pre-set for its correct use. For personalisation
and installation information see the relative
instructions book.
Attention: the probes supplied are used in ac-
cordance with the pre-xed purpose:
T1 PT1000 solar probe
T2 NTC boiler probe.
Technical data:
Power Supply 220 ÷ 240 V AC
Stand-by 3,5 W
Inputs 2 temperature probes (pt
1000)
2 NTC 10 k probes
Outputs 3 relay
Room temp. 0 ÷ 40 °C
Protection type IP 20 / DIN40050
Fuse T 4 A
key:
A - Control
1 - Terminal T2 probe NTC
2 - Terminal T1 probe
PT1000
3 - Terminal T4 probe
PT1000
4 - Terminal T3 probe NTC
5 - terminal connection to
the mains
6 - Relay Terminals 1 -
circulation pump
7 - relay 2 terminal
8 - relay 3 terminal
key:
A - Control
key:
1 - Forward
2 - Reverse
3 - Set (Selection / operation
mode)

17
1-14
1
2
3
4
5
6
7
6
10
11
1
4
8
12
2
13 3
5
14
9
1
2
3
4
5
6
7
6
3
5
14
13
17
15
10
1
16
18
2
11
12
4
9
8
INSTALLERUSERMAINTENANCE TECHNICIAN
Key:
1 - Solar pump
2 - Non-return valve, thermometer and
cock
3 - Valve drain tting
4 - Flow meter
5 6 bar safety valve
6 - 3/4” connection for expansion vessel
7 - Manometer
8 - Draining valve
9 - Filling valve
10 - Insulating casing
11 - Flow rate regulator
12 - Boiler inlet
13 - Solar collector towards output
14 - Reference for ow rate reading
15 - Non-return valve, thermometer and
cock
16 - Degasser
17 - Solar collector inlet
18 - Boiler towards output
1.12 CIRCULATION UNIT.
e pump unit allows to connect the storage tank
to the solar collector, making the water circulate
according to the request of the control unit.
Two types of circulation units are present, single
coupled at collectors (CP4XL) and double cou-
pled vacuum collectors (CSV14).
Technical data:
Continuous functioning
temp.
130°C
Short term ignition temp. 150°C
Safety valve pressure 6 bar
Pump consumption 36 W
Max. pump head 6,5 m
Max. pump capacity 1,8 m3
Regulator control range
ow rate
1-6 l/min
EEI ≤ 0,20 - Part 3

18
1-15
1
Ø 18
DN 16
DN 20
2
Ø 18 DN 16 DN 20
34
566
7
8
3 4 7 9
3
3
3
310
10
3
47
9
3
11
5
4
4
7
8
INSTALLERUSERMAINTENANCE TECHNICIAN
1.13 HYDRAULIC CONNECTION
CP4XL FLAT COLLECTORS.
e collectors installation must be carried out
using the complete kits supplied by Immergas.
e following can be connected to maximum
six collectors in series, using the connection kits
additional collectors.
N.B.: when mounting the ttings, including the
air vent valve, apply teon or other material with
similar characteristics.
N.B.: before nearing the two solar collectors,
insert both bushes (3) in the connection pipe
and mount at least one side of the tting (10).
Flat collector connection kit:
Air venting unit with probe holder bulb (1)
Vabco tting (2)
Bearing (3)
Ogive tting (4)
Bearing (5)
Nipples (6)
Gasket (7)
Reduction (8)
Cap (9)
Ogive tting (10)
Ogive tting (11)

19
1-16
Ø 18 DN 16 DN 20
12
3
4
55
6
7
6
Ø 18
DN 16
DN 20
43
5
6
56
7
8 96
Ø 18 DN 16 DN 20
1
2
3
4
55
6
7
8 96
INSTALLERUSERMAINTENANCE TECHNICIAN
1.14 HYDRAULIC CONNECTION
CSV14 VACUUM COLLECTORS.
e collectors installation must be carried out using
the complete kits supplied by Immergas.
e following can be connected to maximum
six collectors in series, using the connection kits
additional collectors.
N.B.: when mounting the ttings, including the
air vent valve, apply teon or other material with
similar characteristics.
Vacuum collector connection kit:
Nipples (1)
Air venting unit with probe holder bulb (2)
Vabco tting (3)
Bearing (4)
Nipples (5)
Gasket (6)
Reduction (7)
Extension tting (8)
Gasket (9)
VARIANT FOR INSTALLATION ON THE
LEFT

20
1-16
INSTALLERUSERMAINTENANCE TECHNICIAN
1.15 CIRCULATION UNIT HYDRAULIC
CONNECTION.
e device is pre-assembled before delivery. e
pipes for connection must be ordered separately.
To avoid any vapour entering the expansion
vessel, position the expansion vessel lower than
the collectors. If the vessel is positioned above
the collectors height, it must be connected by
means of a particular pipe to prevent the vessel
from heating up (this pipe, which is not supplied
by Immergas, interrupts the laminar circulation).
Every time the system is emptied, it must be
rinsed well with running water. e circulation
unit is not designed for use in direct contact with
swimming pool water.
1.16 ASSEMBLY INSTRUCTIONS.
a) remove the device from the insulation casing
by removing the front and rear halves.
b) drill two holes Ø 8 on the wall in correspond-
ence with the holes on the supporting plate.
c) x the supporting plate to the wall by placing
the rear half of the insulation casing.
d) connect the circulation group fittings in
accordance to the indications of the gures
using the ttings kit supplied separately. If
using copper pipes or pipes of limited physical
resistance their terminals must be reinforced.
e terminal part of the pipe must be cut
perpendicular in respect to the pipe axis and
cleaned.
e) Mount the safety valve unit on the circulation
unit. e safety valve outlet must be connected
to a draining funnel. Otherwise, the manu-
facturer declines any responsibility in case of
ooding if the drain valve cuts in.
f) Connect the electric cable of the circulation
unit as indicated in the respective manual of
the control unit, positioning it at the centre of
the device.
g)Cover the circulation unit with the front case
previously removed.
This manual suits for next models
17