Imtra LIM80110 User manual

1
PowerLED Dimming Control
Reference Manual
ILIM80110
Imtra PowerLED Dimmer
(see page 3)
ILIM80102
Captiva PowerLED Dimmer
(see page 4)
ILIM80200
PowerLED Analog Dimmer
(see page 5)
PWM Control of PowerLED Lights
thru a centralized lighting control
system
(see page 6)
2
Overview
In order to provide control of our PowerLED lighting fixtures to support
various lighting applications, Imtra offers a range of dimming control
solutions.
For typical applications, an ILIM80110 dimmer module may be used with
any number of normally open momentary pushbuttons to control up to 30*
PowerLED lights.
Lighting circuits that include one or more Captiva PowerLEDs require an
ILIM80102. This dimmer module can also be controlled by any number of
normally open momentary pushbuttons and it can control up to 50*
PowerLED lights.
For applications where it is necessary to integrate with a third party
automated control system, one of two solutions may be employed.
1. A 0-10V analog signal may be used to control the PowerLEDs via
our ILIM80200 dimmer module. This dimmer module requires a 0-
10V analog signal source and can control up to 30* PowerLED
lights.
2. A Pulse Width Modulating signal may be used to control the
PowerLEDs directly via the white and grey dimming signal wires.
Specifications
ILIM80110 ILIM80102 ILIM80200
Height 0.90” (23mm) 0.84”(21mm) 0.63” (16mm)
Width 3.86” (98mm) 2.53”(64mm) 2.63” (67mm)
Depth 2.10” (52mm) 1.47”(37mm) 1.38” (35mm)
Input Voltage Range 10-30VDC
Max. Output Current 0.03A 0.05A 0.03A
Capacity 30 Fixtures* 50 Fixtures* 30 Fixtures*
Control Interface N.O. Contacts N.O. Contacts 0-10V Analog
IP Rating IP40
*Note: Exceeding maximum number of fixtures can permanently damage
dimmer module.

3
Imtra PowerLED Dimmer
The ILIM80110 PowerLED Dimmer Module is used to
manually operate a circuit of PowerLED Lights with on/off and
dimming control. Before making any connections, be sure all
power in the circuit is turned off at the breaker. To install
your PowerLED dimmer, connect the wires according to the following
wiring schematic. Failure to follow the wiring schematic exactly as shown
will result in failure & permanent damage to the dimmer.
To operate your PowerLED Dimmer Module and Lights:
Tap any one of the momentary pushbuttons to turn on or off.
Press and hold any one of the momentary pushbuttons to dim up
or down.
Note:
When DC voltage to the PowerLED Dimmer and Lights is lost, the
default setting when powered up again is always off.
A tap of the momentary pushbutton will always turn the PowerLED
Dimmer and Lights on to the previous setting.
V
oltage Supply
(battery, converter, etc)
Momentary
Pushbutton
Imtra
PowerLED
ILIM80110
Dimmer Module
Imtra
PowerLED
Momentary
Pushbutton
To other PowerLEDs
(up to 30 total)
To other
control
push
buttons
4
Captiva PowerLED Dimmer Module
The ILIM80102 Captiva PowerLED Dimmer Module is
specifically designed to control the Captiva PowerLED
down spot. However, it may also be used to control a
circuit which contains both Captiva and Hatteras PowerLED
down spots. Before making any connections, be sure all
power in the circuit is turned off at the breaker. To install your dimmer,
connect the wires according to the following schematic. Failure to follow
the wiring schematic exactly as shown will result in failure & permanent
damage to the dimmer.
To operate your Captiva PowerLED Dimmer Module and Lights:
Tap any one of the momentary pushbuttons to turn on or off.
Press and hold any one of the momentary pushbuttons to dim up
or down.
Note:
When DC voltage to the PowerLED Dimmer and Lights is lost, the
default setting when powered up again is always off.
A tap of the momentary pushbutton will always turn the PowerLED
Dimmer and Lights on to the previous setting.
Momentary
Pushbutton
Other
PowerLED
V
oltage Supply
(battery, converter, etc)
ILIM80102
Dimmer Module
Captiva
PowerLED
Momentary
Pushbutton
To other PowerLEDs
(up to 50 total)
To other
control
push
buttons

5
PowerLED Analog Dimmer Module
The ILIM80200 PowerLED Analog Dimmer Module is
used for automated control of a circuit of PowerLED
Lights. The ILIM80200 PowerLED Dimmer Module
can interface with any control system that can provide
a 0-10VDC Analog signal. Before making any
connections, be sure all power in the circuit is turned
off at the breaker. To install your PowerLED dimmer, connect the wires
according to the following schematic. Failure to follow the wiring schematic
exactly as shown will result in failure & permanent damage to the dimmer.
Note:
The ILIM80200 PowerLED Dimmer Module requires a 0-10VDC
signal source. It does not provide a 10VDC voltage to be
modulated and returned.
A 0V signal input will render a 0% light output.
A 10V signal input will render a 100% light output.
0-10V Analog
Signal Source
Imtra
PowerLED
V
oltage Supply
(battery, converter, etc)
Control System
0-10V Analog
Control Unit
Imtra
PowerLED
(+)
(-)
To other PowerLEDs
(up to 30 total)
ILIM80200
Dimmer Module
6
PWM Control of PowerLED Lights
Imtra PowerLED Lights can also be controlled with a Pulse Width
Modulating signal. Many centralized lighting automation systems use this
type of control. To control your PowerLED using a PWM signal, the wiring
and signal parameters should be configured according to details below.
Note:
5.0mS<TPWM<8.33mS (PWM Frequency=120-200Hz)
Dim signal voltage to be 0VDC<VO<1.7VDC &
2.1VDC<VI<30VDC
Current Sink I=1mA
Imtra
PowerLED
V
oltage Supply
(battery, converter, etc)
Control System
PWM Control
Module
Imtra
PowerLED
PWM Signal Parameters
V
T
VI
0
VO
TPWM
(+)
(-)
To other PowerLEDs

7
Limited Warranty
Imtra warrants these dimming control products for 1 year from the date of
purchase. If the dimmer module should cease to function within 1 year,
return it to Imtra for repair or replacement.
This warranty does not apply to damage resulting from actions of the user
such as misuse, improper wiring/installation, operation outside of
specification, improper maintenance or repair, unauthorized modification,
lightning strike or damage from a power surge.
Imtra specifically disclaims any implied warranties, merchantability or fitness
for a specific purpose and will not be liable for any direct, indirect,
incidental or consequential damages. Imtra's total liability is limited to
repair or replacement of the product.
The warranty set forth above is inclusive and no other warranty, whether
written or oral, is expressed or implied.
If it should become necessary to return a fixture for service during or
beyond the warranty period, please refer to Imtra's standard Return Policy
as detailed on Imtra's website (www.imtra.com) or call Imtra customer
service at (508) 995-7000.
No returns are accepted without a Return Authorization (RA) number.
8
30 Samuel Barnet Boulevard, New Bedford, MA 02745
(508) 995-7000 www.imtra.com
This manual suits for next models
2
Table of contents
Popular Control System manuals by other brands

Pilz
Pilz PSS67 IO1 16FDI operating manual

Minitech
Minitech Mini-Mill Series user guide

LEGRAND
LEGRAND Pass & Seymour Harmony De-Hummer installation instructions

Skip-Line
Skip-Line SC-12 quick start guide

Mitsubishi Electric
Mitsubishi Electric MELDAS 60 Series Programming manual

DSE
DSE DSEG8680 installation instructions

OBSIDIAN CONTROL SYSTEMS
OBSIDIAN CONTROL SYSTEMS NETRON EN12 installation guide

Eaton
Eaton CCS 5 instruction manual

Aspire
Aspire RFTCP installation guide

Skov
Skov BlueControl Pig Technical manual

PACH & COMPANY
PACH & COMPANY AeGIS AFGR9 Installation and programming manual

Siemens
Siemens SINUMERIK 840D sl Commissioning manual