manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ingersoll-Rand
  6. •
  7. Air Compressor
  8. •
  9. Ingersoll-Rand HP600WJD User manual

Ingersoll-Rand HP600WJD User manual

This manual suits for next models

3

Other Ingersoll-Rand Air Compressor manuals

Ingersoll-Rand GHH RAND SILU CS90 User manual

Ingersoll-Rand

Ingersoll-Rand GHH RAND SILU CS90 User manual

Ingersoll-Rand Sierra SL 90 User manual

Ingersoll-Rand

Ingersoll-Rand Sierra SL 90 User manual

Ingersoll-Rand R37-45 kW User manual

Ingersoll-Rand

Ingersoll-Rand R37-45 kW User manual

Ingersoll-Rand UP6 20 HP User manual

Ingersoll-Rand

Ingersoll-Rand UP6 20 HP User manual

Ingersoll-Rand 2340 User manual

Ingersoll-Rand

Ingersoll-Rand 2340 User manual

Ingersoll-Rand RS15ie Setup guide

Ingersoll-Rand

Ingersoll-Rand RS15ie Setup guide

Ingersoll-Rand 7/31E User manual

Ingersoll-Rand

Ingersoll-Rand 7/31E User manual

Ingersoll-Rand SSR-2000 User manual

Ingersoll-Rand

Ingersoll-Rand SSR-2000 User manual

Ingersoll-Rand 125-200 Assembly instructions

Ingersoll-Rand

Ingersoll-Rand 125-200 Assembly instructions

Ingersoll-Rand SSR UP5-4 User manual

Ingersoll-Rand

Ingersoll-Rand SSR UP5-4 User manual

Ingersoll-Rand P1.5IU-A9 User manual

Ingersoll-Rand

Ingersoll-Rand P1.5IU-A9 User manual

Ingersoll-Rand Doosan XHP1070CMH-1800 User manual

Ingersoll-Rand

Ingersoll-Rand Doosan XHP1070CMH-1800 User manual

Ingersoll-Rand SSR UP5-4 User manual

Ingersoll-Rand

Ingersoll-Rand SSR UP5-4 User manual

Ingersoll-Rand R37-160 Setup guide

Ingersoll-Rand

Ingersoll-Rand R37-160 Setup guide

Ingersoll-Rand SS3 User manual

Ingersoll-Rand

Ingersoll-Rand SS3 User manual

Ingersoll-Rand 7/26E User manual

Ingersoll-Rand

Ingersoll-Rand 7/26E User manual

Ingersoll-Rand TS4L5 User manual

Ingersoll-Rand

Ingersoll-Rand TS4L5 User manual

Ingersoll-Rand RS45i Setup guide

Ingersoll-Rand

Ingersoll-Rand RS45i Setup guide

Ingersoll-Rand XHP650CM Installation and operation manual

Ingersoll-Rand

Ingersoll-Rand XHP650CM Installation and operation manual

Ingersoll-Rand P1IU-A9 User manual

Ingersoll-Rand

Ingersoll-Rand P1IU-A9 User manual

Ingersoll-Rand SV200 Quick guide

Ingersoll-Rand

Ingersoll-Rand SV200 Quick guide

Ingersoll-Rand EP 20 SE User manual

Ingersoll-Rand

Ingersoll-Rand EP 20 SE User manual

Ingersoll-Rand HP600A-WCU User manual

Ingersoll-Rand

Ingersoll-Rand HP600A-WCU User manual

Ingersoll-Rand HP300WCU User manual

Ingersoll-Rand

Ingersoll-Rand HP300WCU User manual

Popular Air Compressor manuals by other brands

Craftsman 919.724591 owner's manual

Craftsman

Craftsman 919.724591 owner's manual

Atlas Copco GA 30+ Instruction book

Atlas Copco

Atlas Copco GA 30+ Instruction book

Hitachi Highly WHP11500VSDPC9EQ installation manual

Hitachi

Hitachi Highly WHP11500VSDPC9EQ installation manual

Craftsman 919.167810 owner's manual

Craftsman

Craftsman 919.167810 owner's manual

Yamato 24/2 M1CD instruction manual

Yamato

Yamato 24/2 M1CD instruction manual

Clarke 2242117 Operation & maintenance instructions

Clarke

Clarke 2242117 Operation & maintenance instructions

Sparmax DC-25XR user manual

Sparmax

Sparmax DC-25XR user manual

Briggs & Stratton Air Compressor Operator's manual

Briggs & Stratton

Briggs & Stratton Air Compressor Operator's manual

Fini F3GST2TK Operator's manual

Fini

Fini F3GST2TK Operator's manual

Campbell Hausfeld RP3300 Easy setup guide

Campbell Hausfeld

Campbell Hausfeld RP3300 Easy setup guide

Parkside PKO 270 A1 operating instructions

Parkside

Parkside PKO 270 A1 operating instructions

Clas Ohlson QIE-ZTH-15 manual

Clas Ohlson

Clas Ohlson QIE-ZTH-15 manual

Ferm CRM1046 Original instructions

Ferm

Ferm CRM1046 Original instructions

BE AC153 Operation manual

BE

BE AC153 Operation manual

RIDGID OF25150A Operator's manual

RIDGID

RIDGID OF25150A Operator's manual

Johnson Controls QUANTUM LX Setup

Johnson Controls

Johnson Controls QUANTUM LX Setup

Ring Automotive RAC700 instructions

Ring Automotive

Ring Automotive RAC700 instructions

Craftsman 919.184190 owner's manual

Craftsman

Craftsman 919.184190 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Book 35389923 (04/02) 1
()
Code:
This manual contains important safety information.
Do not destroy this manual.
This manual must be available to the personnel who operate and maintain this machine.
!
Portable Air Compressor Division
P.O. Box 868 -- 501 Sanford Ave
Mocksville, N.C. 27028
OPERATING, MAINTENANCE,
PARTS MANUAL
COMPRESSOR MODEL
HP600WJD
XP750WJD
HP750WJD
XP825WJD
Book 35389923 (04/02) 2
()
QUALITY POLICY
We will supply products and services that consistently meet the requirements
of our customers and each other.
CALIFORNIA
Proposition 65 Warning
Diesel engine exhaust and some of its constituents are known
to the State of California to cause cancer, birth defects, and
other reproductive harm.
Book 35389923 (04/02) 3
()
Foreword
Machine models represented in this manual may be used in various locations worldwide. Machines sold and
shipped into European common market countries requires that the machine display the EC Mark and conform to
various directives. In such cases, the design specification of this machine has been certified as complying with EC
directives. Any modification to any part is absolutely prohibited and would result in the CE certification and marking
being rendered invalid. A declaration of that conformity follows:
Declaration of Conformity
WITH EC DIRECTIVE
We
Ingersoll--Rand Company
P.O. Box 868
501 Sanford Avenue
Mocksville, North Carolina 27028
Declare that, under our sole responsibility for manufacture and supply, the product(s)
To which this declaration relates, is (are) in conformity with the provisions of the above
directives using the following principal standards
________________________________
Represented In EC By:
Ingersoll--Rand Company Limited
Swan Lane, Hindley Green
Wigan WN2 4EZ
United Kingdom
Issued at Mocksville on 1--1--95 Issued at Hindley Green on 1--1--95
________________________________
EN1012--1, EN29001, EN202, EN60204--1
PN8NTC2, EN 50081, EN50082
HP1300WCU
XP1400WCU
P1600WCU
XP900WCU
XHP900WCAT
XHP650WCAT
XHP750WCAT
XHP825WCAT
VHP825WCU
HP935WCU
XP1050WCU
HP825WCU
VHP750WCAT
VHP850WCAT
HP900WCAT
XP1000WCAT
98/37/EC
XHP1070CAT
NXP1300WCU
H. Seddon, Q.A. Manager
Ric Lunsford
Manager of Quality Control
Book 35389923 (04/02) 4
()
Nothing contained in this document is intended to extend any promise, warranty or representation, expressed or
implied, regarding the Ingersoll--Rand products described herein. Any such warranties or other terms and
conditions of sale of products shall be in accordance with the standard terms and conditions of sale for such
products, which are available upon request.
This manual contains instructions and technical data to cover all routine operation and scheduled maintenance
tasks by operation and maintenance staff. Major overhauls are outside the scope of this manual and should be
referred to an authorized Ingersoll--Rand service department.
All components, accessories, pipes and connectors added to the compressed air system should be:
Sof good quality, procured from a reputable manufacturer and, wherever possible, be of a type approved by
Ingersoll--Rand.
Sclearly rated for a pressure at least equal to the machine maximum allowable working pressure.
Scompatible with the compressor lubricant/coolant.
Saccompanied with instructions for safe installation, operation and maintenance.
Details of approved equipment are available from Ingersoll--Rand Service departments.
The use of repair parts other than those included within the Ingersoll--Rand approved parts list may create
hazardous conditions over which Ingersoll--Rand has no control. Therefore, Ingersoll--Rand cannot be held
responsible for equipment in which non--approved repair parts are installed.
Ingersoll--Rand reserves the right to make changes and improvements to products without notice and without
incurring any obligation to make such changes or add such improvements to products sold previously.
The intended uses of this machine are outlined below and examples of unapproved usage are also given. However,
Ingersoll--Rand cannot anticipate every application or work situation that may arise. If in doubt, consult
supervision.
This machine has been designed and supplied for above ground operation to be used for compression of normal
ambient air containing no additional gases, vapors or particles within the ambient temperature range specified in
the general data section of this manual.
This machine should not be used:
A. For direct or indirect human consumption of the compressed air.
B. Outside the ambient temperature range specified in the general data section of this manual.
C. When an actual or foreseeable risk of hazardous levels of flammable gases or vapors exists.
D. With other than Ingersoll--Rand approved components.
E. With guards, or controls or switches missing or disabled.
F. For storage or transportation of materials inside or on the enclosure.
This company accepts no responsibility for errors in translation of this manual from the original English version.
Book 35389923 (04/02) 5
()
TABLE OF CONTENTS
SECTION 1 SAFETY...............
SECTION 2 WARRANTY/REGISTRATION...............
SECTION 3 NOISE EMISSION...............
SECTION 4 GENERAL DATA...............
SECTION 5 OPERATION...............
SECTION 6 MAINTENANCE...............
SECTION 7 LUBRICATION...............
SECTION 8 TROUBLESHOOTING...............
SECTION 9 PARTS ORDERING...............
SECTION 10 PARTS LIST..............
SECTION 11 OPTIONS PARTS LIST..............
SECTION 12 ENGINE..............
Book 35389923 (04/02) 6
()
SECTION 1-- SAFETY
SAFETY PRECAUTIONS
General Information
Ensure that the operator reads and understands the
decals and consults the manuals before maintenance
or operation.
Ensure that the Operation and Maintenance manual,
and the manual holder if equipped, are not removed
permanently from the machine.
Ensure that maintenance personnel are adequately
trained, competent and have read the manuals.
Make sure that all protective covers are in place and
that the canopy/doors are closed during operation.
The specification of this machine is such that the ma-
chine is not suitable for use in flammable gas risk
areas. If such an application is required then all local
regulations, codes of practice and site rules must be
observed. To ensure that the machine can operate in
a safe and reliable manner, additional equipment such
as gas detection, exhaust spark arrestors, and intake
(shut--off) valves may be required, dependent on local
regulations or the degree of risk involved.
Air discharged from this machine may contain carbon
monoxide or other contaminants which will cause seri-
ous injury or death. Do not breathe this air.
Compressed air can be dangerous if incorrectly han-
dled. Before doing any work on the unit, ensure that all
pressure is vented from the system and that the ma-
chine cannot be started accidentally.
Ensure that the machine is operating at the rated pres-
sure and that the rated pressure is known to all rele-
vant personnel.
All air pressure equipment installed in or connected to
the machine must have safe working pressure ratings
of at least the machine safety valve rating.
If more than one compressor is connected to one com-
mon downstream plant, effective check valves and
isolation valves must be fitted and controlled by work
procedures, so that one machine cannot accidentally
be pressurized or over pressurized by another.
Compressed air must not be used for a feed to any
form of breathing apparatus or mask.
The discharged air contains a very small percentage
of compressor lubricating oil and care should be taken
to ensure that downstream equipment is compatible.
If the discharged air is to be ultimately released into a
confined space, adequate ventilation must be pro-
vided.
When using compressed air, always use appropriate
personal protective equipment.
All pressure containing parts, especially flexible hoses
and their couplings, must be regularly inspected, be
free from defects and be replaced according to the
Manual instructions.
Avoid bodily contact with compressed air.
The safety valve located in the separator tank must be
checked periodically for correct operation.
Never operate unit without first observing all safety
warnings and carefully reading the operation and
maintenance manual shipped from the factory with
this machine.
Never operate the engine of this machine inside a
building without adequate ventilation. Avoid breathing
exhaust fumes when working on or near the machine.
Do not alter or modify this machine.
A battery contains sulfuric acid and can give off gases
which are corrosive and potentially explosive. Avoid
contact with skin, eyes and clothing. In case of con-
tact, flush area immediately with water.
Exercise extreme caution when using booster battery.
To jump battery, connect ends of one booster cable to
the positive (+) terminal of each battery. Connect one
end of other cable to the negative (--) terminal of the
booster battery and other end to a ground connection
away from dead battery (to avoid a spark occurring
near any explosive gases that may be present). After
starting unit, always disconnect cables in reverse or-
der.
Never operate unit without first observing all safety
warnings and carefully reading the operation and
maintenance manual shipped from the factory with
this machine.
Book 35389923 (04/02) 7
()
This machine may include such materials as oil, diesel
fuel, antifreeze, brake fluid, oil/air filters and batteries
which may require proper disposal when performing
maintenance and service tasks. Contact local authori-
ties for proper disposal of these materials.
A battery contains sulfuric acid and can give off gases
which are corrosive and potentially explosive. Avoid
contact with skin, eyes and clothing. In case of con-
tact, flush area immediately with water.
High Pressure Air can cause serious injury or death.
Relieve pressure before removing filler plugs/caps, fit-
tings or covers.
Air pressure can remain trapped in air supply line
which can result in serious injury or death. Always
carefully vent air supply line at tool or vent valve before
performing any service.
This machine produces loud noise with the doors open
or service valve vented. Extended exposure to loud
noise can cause hearing loss. Always wear hearing
protection when doors are open or service valve is
vented.
Never inspect or service unit without first disconnect-
ing battery cable(s) to prevent accidental starting.
Do not remove the pressure cap from a HOT radiator.
Allow radiator to cool down before removing pressure
cap.
Do not use petroleum products (solvents or fuels) un-
der high pressure as this can penetrate the skin and
result in serious illness. wear eye protection while
cleaning unit with compressed air to prevent debris
from injuring eye(s).
Disconnected air hoses whip and can cause serious
injury or death. Always attach a safety flow restrictor
to each hose at the source of supply or branch line in
accordance with OSHA Regulation 29CFR Section
1926.302(b).
Hot pressurized fluid can cause serious burns. Do not
open radiator while hot.
Rotating fan blade can cause serious injury. Do not
operate without guard in place.
Use care to avoid contacting hot surfaces (engine
exhaust manifold and piping, air receiver and air
discharge piping, etc.).
Ether is an extremely volatile, highly flammable gas.
USE SPARINGLY! Do NOT use ETHER if unit has
GLOW Plug starting aid. Engine damage will result.
Never allow the unit to sit stopped with pressure in the
receiver--separator system. As a precaution, open the
manual blowdown valve.
Never operate unit with guards, covers or screens
removed. Keep hands, hair, clothing, tools, blow gun
tips, etc. well away from moving parts.
Make sure wheels, tires and tow bar connectors are in
safe operating condition and tow bar is properly
connected before towing.
Whenever the machine is stopped, air will flow back
into the compressor system from devices or systems
downstream of the machine unless the service valve
is closed. Install a check valve at the machine service
valve to prevent reverse flow in the event of an
unexpected shutdown when the service valve is open.
Hazardous Substance Precaution
The following substances are used in the manufacture
of this machine and may be hazardous to health if
used incorrectly.
Precaution: Avoid ingestion, skin contact and
breathing fumes for the following substances:
Antifreeze, Compressor Oil, Engine Lubricating Oil,
Preservative Grease, Rust Preventative, Diesel Fuel
and Battery Electrolyte.
The following substances may be produced during the
operation of this machine and may be hazardous to
health:
Avoid build--up of Engine Exhaust Fumes in confined
spaces.
Avoid breathing Exhaust Fumes.
Avoid breathing Brake Lining Dust during mainte-
nance.
Book 35389923 (04/02) 8
()
SAFETY LABELS
Corrosion risk
Do not operate the machine
without guard being fitted.
Hot Surface
WARNING: Electrical shock risk.
Lifting point
Parking Brake No open flame
When parking use prop stand,
WARNING -- Hot and harmful exhaust gas.
WARNING -- Flammable liquid.
Air/gas flow or Air discharge.
Look for these signs on machines shipped to international markets outside North America, which
point out potential hazards to the safety of you and others. Read and understand thoroughly. Heed
warnings and follow instructions. If you do not understand, inform you supervisor.
handbrake and wheel chocks.
Diesel Fuel.
No open flame.
Do not breathe the compressed
air from this machine.
Lifting point
Tie down point
Book 35389923 (04/02) 9
()
Read the Operation and Maintenance
manual before operation or maintenance
of this machine is undertaken. X,XBAR
WARNING -- Maintain correct tire pressure.
(Refer to the GENERAL INFORMATION section
of this manual).
Rough Service Designation
Wet Location Operation
WARNING: Consult the operation
and maintenance manual before
performing any maintenance.
WARNING -- Before connecting the tow bar or
when preparing to tow, consult the operation
and maintenance manual.
Replace any cracked
protective shield.
On (power).
Off (power).
Emergency stop.
Do not use fork lift truck from this side
Do not stack
Do not operate with the doors or enclosure
open.
Book 35389923 (04/02) 10
()
Oil Drain
WARNING -- Do not undertake any
maintenance on this machine until the
electrical supply is disconnected and the air
pressure is totally relieved.
Read the Operation and Maintenance manual
before operation or maintenance of this
machine is undertaken
XX
km/h
Pressurized component or system.
Do not exceed the speed limit.
Pressurized vessel.
Do not remove the Operating and
Maintenance manual and manual holder from
this machine.
Use fork lift truck from this side only.
0_C
WARNING -- For operating temperature below
0_C, consult the operation and maintenance
manual.