Inhep Digital Security IDS816 Assembly instructions

Installer Guide to Wiring and
Keypad Programming
I
N
H
E
P
D
I
G
I
T
A
L
S
E
C
U
R
I
T
Y
IDS
IDS816
IDS816
MANUALNO.700-283-02BISSUEDNOVEMBER2004 VERSION2.00

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
2
stnetnoC.1
1. Introduction to the IDS816 ........................................4
1.1 Features of the IDS 816 ................................................5
2. Installation and Wiring ...............................................6
3. End-of-Line Resistors/Tamper by Zone/Zone...........
Doubling .......................................................................7
4. Box Tamper Input ........................................................8
5. Installing an Expander Module ................................8
6. Connecting the Telephone Communicator ............9
7. Programmable Outputs..............................................9
8. Key-Switch or Remote Control Unit .........................9
9. IDS Remote Receiver...............................................10
10 Additional Technical Data ........................................10
11. Radio Transmitter Connection................................10
12. Hardware Reset Switch............................................10
13. Defaulting Keypads ..................................................11
14. Event Log ................................................................... 11
15. Download Code ......................................................... 11
16. Programming Instructions.......................................12
16.1 Introduction ..................................................................12
16.2 Location Values............................................................12
17. Programming the Panel ...........................................13
17.1 Entering Program Mode...............................................13
17.2 Programming Standard Locations ...............................14
17.3 Programming Extended Locations...............................14
17.4 Programming Bitmapped Location ..............................15
17.5 Incorrect Data Entries ..................................................16
17.6 Programming Location Summary............................16
17.6.1 Zone Options...........................................................16
17.6.2 System Options .......................................................22
17.6.3 System Reporting Codes ........................................29
17.6.4 System Programmable Outputs..............................31
17.6.5 System Clock Options .............................................34
17.6.6 Communicator Options ...........................................36
17.6.7 Partition Setup.........................................................45
17.6.8 User Options ...........................................................53
17.6.9 Programmable Output Options ...............................56
17.6.10 Keypad Options ......................................................57
17.6.11 Installer Options ......................................................59

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 3
Location Tables ........................................................................61
serugiF
Figure 1: Connection Diagram without Tamper per Zone .....6
Figure 2: Tamper per Zone Connection ................................7
Figure 3: Zone Doubling Connection.....................................8
Figure 4: Resistors used for Tamper per Zone or Zone ..........
Doubling.................................................................9
Figure 5: Programmable Output Configuration.....................9
Figure 6: Fire Detect Output Sequence..............................34
selbaT
Table1: Value Represented by each Zone Indicator .........12
Table 2: Binary Representation .........................................12
Table3: HexadecimalValue ..............................................13
Table 4: Location / Zone defaults.......................................17
Table 5: Programmable Zone Types .................................18
Table 6: Programmable Ouput Numbering .......................31
Table 7: Output Actions .....................................................32
Table 8: Summary of System Event Driven ..........................
Programmable Outputs .......................................33
Table 9: Summary of System Function Driven......................
Programmable Outputs .......................................34
Table 10: Value for Day of the Week ...................................35
Table 11: Standard Contact I.D Reporting Codes ...............39
Table 12: Standard Contact I.D Reporting Codes ...............53
Tabe 13: Location Number - User Codes...........................54

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
4
618SDIehtotnoitcudortnI.1
TheIDS816 is aversatile, microprocessor basedeight zonealarm
panel. It has two partitions and can be expanded to sixteen zones.
Mostfeatures areoptionaland maybeprogrammed eitherdirectly
through the keypad or via the telephone system, using the IDS
downloadsoftwareandappropriate modem. There areeight
programmableburglary zones, adedicatedpanic zone, monitored
sirenoutput, auxiliary poweroutputsand five programmableoutputs
whichmaybe programmedto performvarioustrigger/switching
functions.
For correct operation the IDS816 must be used in conjunction with the
specifiedtransformer/batterycombinationand appropriate peripheral
sensorsand signalling devices.
I
N
H
E
P
D
I
G
I
T
A
L
S
E
C
U
R
I
T
Y
IDS

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 5
1
618SDIehtfoserutaeF1.1
!RS485keypad bussupportsone eightzoneexpander module,
oneIDS remotereceiverand upto 8 keypads.
!Eightprogrammable,end-of-linesupervised zoneinputs.
!Expandable to sixteen zones via keypad / zone expander module
orzonedoubling
!2partitions
!Optionaltamperreporting per zoneusing doubleend-of-line
resistors(12K and4K7).
!Fullyprogrammabledigital telephonecommunicatorwhich
supportsmost industrystandard formats.
!Panelsupports securedial-infunctionality usingany DTMF
phone.
!Fiveprogrammableoutputs on alarmpanel.Expandableto seven
whenusingWired ZoneExpander module.
!Nonvolatile EEPROM memory retainsall programandevent log
datain theeventof atotal power failure.
!Eventlog (one thousandevents) date andtimestamped.
!Programmableloopresponse time.
!Upand downloadable usingIDS Windowsbased software, either
directvia RS232 orremote usinga modem
!Excellentprotection against lightning(provided by specialised
“zaptracking” andtransientsuppressors).
!Auto arm / disarm capability per partition and by day of the
week. The panel can be programmed to arm /disarm at a
pre-determinedtime.
!Faxdefeat/ answering machineoverride.
!Dualreportingprovides for duplicatedreporting totwo independent
central base stations.
!Dynamic battery self test.
!Low battery cutout circuit.

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
6
gniriWdnanoitallatsnI.2
Pleaserefer to Figure1:Connection Diagramandfamiliarise yourself
withthe followingsections.
enoZreprepmaTtuohtiwmargaiDnoitcennoC.1erugiF

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 7
/enoZybrepmaT/srotsiseReniL-fo-dnE.3 gnilbuoDenoZ
!Allzones mustbeend-of-line supervised.Anyunusedzones
must be terminated with a 3K3 resistor.
!The end of line resistor must be placed inside or as close to the
sensor as possible.
!Any zone that is not to be doubled or to report
tamper-by-zonemustuse a3K3end-of-line resistor.
!Forzone doublingortamper perzone,the 4K7and12K end-of-
line resistors must be connected as per Figures 2 and 3.
noitcennoCenoZreprepmaT.2erugiF
!Tamper operation isas follows:
!If the panel is unarmed and a tamper condition occurs, the
siren will not sound but a tamper condition will be reported.
!If the panel is armed and a tamper condition occurs an
audiblealarm willregister andatamper conditionwill be
reported.
!Panic zones always register panic and tamper conditions.
!The colour codes for the 12K and 4K7 resistors are as per
in Figure 4.

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
8
noitcennoCgnilbuoDenoZ.3erugiF
The following limitations apply to zone doubling:
1. Only normally closed contacts (n/c) may be used.
2. If the zone input is short circuited at the panel, both the zone and
itsdouble willbeviolated.
3. If the 4K7 resistor is open circuited by the sensor, the primary
zonewill indicateaviolation.
4. If the 12K resistor is open circuited by the sensor the secondary
zonewill indicateaviolation.
5. The colour codes for the 4K7 and 12K resistors are shown in
Figure4.
tupnIrepmaTxoB.4
Thebox tamperinput doesnot requirean end-of-line resistor.
Use a normally closed contact only.
eludoMrednapxEnagnillatsnI.5
Wheninstalling anexpandermodule refertothe document supplied
withthe module.

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 9
gnilbuoDenoZroenoZreprepmaTrofdesusrotsiseR.4erugiF
rotacinummoCenohpeleTehtgnitcennoC.6
RefertoFigure 1.ConnectionDiagram.
!Foroptimum lightningprotectionconnect alowimpedance earth
tothe communicatorearth input
!Always connect the telephone communicator in line seizure
modeand never inparallel with thetelephone.Ensure the
telephonereceiver isconnectedto the communicatorterminals
marked“phone” andthe incoming lineto the terminalsmarked
“line”.
stuptuOelbammargorP.7
Arelay boardmust be usedwhen anydevice requiring ahigh currentis
connected to a programmable output. The output circuitry of a
programmable output consists of a 12 volt source with a 56Ωseries
resistor.Current sinkis via a1000Ωresistor tonegative.The output
circuitry is shown in Figure 5.
noitarugifnoCtuptuOelbammargorP.5erugiF
tinUlortnoCetomeRrohctiwS-yeK.8
Amomentary key-switchornon-latching remote controlreceiver may
be connected to any zone to allow remote arm/disarm and remote
panic capability.
Purple
Brown Orange
Red
12K 4K7
Yellow Red

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
10
!When using a key-switch or remote control unit a 3K3 resistor
mustbe connectedbetweenthe zoneinput and ground.
!Useonly a spring-loadedmomentarykey-switch ornon-latching
remotecontrol unit.
revieceRetomeRSDI.9
AnIDS Remote Receiver(PN860-06-0002) maybe connectedtothe
keypad bus. This provides the facility to allow 32 users to arm / disarm
the panel with user code identification. Using a remote control.
ataDlacinhceTlanoitiddA.01
!Asuitable transformerwithan outputvoltageof 16voltsAC
±10% with a 16VAminimum rating must be used.A32 VA
transformeris recommended forlargerinstallations.
!A 12V sealed lead acid battery with a minimum capacity of 7AH
mustbe used.The back upperiod aftermainsfailure willdepend
on thenumber of keypads,sensors and peripheraldevices
connected to the system.
!Thepanel cancontinously supply 750mAin totalto peripherals
such as keypads, remotes, receivers, passives etc.
!Connecta 12volt selfdrivensiren orpiezo siren[not a horn
speaker] to the siren output.
noitcennoCrettimsnarToidaR.11
Whenconnecting a radiotransmitterutilize the TXterminal provided
on the P.C.B to supply power to the transmitter. (See Figure 1) This
output is protected by the 4Amp battery fuse.
hctiwSteseRerawdraH.21
Should the need arise to return the panel to factory default, utilise the
hardwarereset switch (seeFigure 1).
Thepanelcan be defaultedbyremoving bothbatteryandACpower
fromthe panel,and thenreapplying thepowerwhile depressingthe
reset switch. Factory default values will be restored to all locations
and all attached keypads I.D’s will be defaulted

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 11
Note: Once the reset switch has been disabled in programming it
will not be possible to default the panel using the reset
switch.The panelcan only bedefaulted ifavalid installer
code is entered and a value of [0] is entered into location 0.
sdapyeKgnitluafeD.31
To default theI.D ofa keypad(s):
1. Removepower to thekeypadand the restorepowerwhile holding
down the [1] and [3] keys simultaneously for three seconds.
2. All the keypad LEDs will flash ON and OFF together. Wait for five
seconds and then press the [#] hash key to allocate a new I.D
to the defaulted keypad. Keypad I.Ds are allocated incrementally.
3. TheI.D ofanykeypad canbe interograted byviewing thedatain
location446.
goLtnevE.41
Acomprehensive log ofthethousand mostrecent eventsare retained
inthe non-volatileEEPROM.The logmaybe retrievedusingthe up/
downloadsoftware.Alternatelyit can beviewed using anLCD keypad.
edoCdaolnwoD.51
A download code in conjunction with the installer code is used for
downloadaccess. Thedefaultdownload codeis9999. Usingthe
downloading software it is possible to program a location that will
eitherallow or disallowdefaulting of thedownloadcode. Thislocation
isonly accessibleusingthe downloadsoftware. If defaultedthe
download code willrevert back to 9999.Avalue of [1] [0]programmed
intothis location willpreventthe downloadcodefrom being defaulted
whenperformingahardwarereset.

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
12
snoitcurtsnIgnimmargorP.61
noitcudortnI1.61
Thepanel can beprogrammed via eitherakeypad orviathe up/
downloadsoftware. Programming thepanel by meansofa LED
keypadis explainedbelow:
Note: Beforecommencing programming itis advisable toread the
InstallerManual thoroughly.
seulaVnoitacoL2.61
All values within a program location will be displayed by the zone
indicatorsin binaryformat.
To read abinary valueonthe keypadsum thevalues represented by
each illuminated LED as shown in Table 1 below:
.rotacidnIenoZhcaeybdetneserpeReulaV1elbaT
1enoZ 1
2enoZ 2
3enoZ 4
4enoZ 8
Thetotal summedvalueis thenumberbeing displayed.
Forexample: assumethefollowing zoneindicators are illuminated:
Zone1, Zone3 andZone 4.Thevalue equalsthesum ofthevalues
displayed by zone LEDs [1], [3],and [4]. See Table 2 below:
noitatneserpeRyraniB2elbaT
1enoZ 1
3enoZ 4
4enoZ 8
latoT31

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 13
lenaPehtgnimmargorP.71
!Forall programmingprocedures, the [!](star) keyfunctions
as the [ENTER] key and the [#] hash key functions as a
[CLEAR] oran [EXIT] program key.
!Invaliddata entries areindicatedvia a threebeeperror beepofthe
keypadbuzzer.
!Thereare twotypesof locationcategories:
• Standardlocations which aresingle tieredanddo not
containany sub-locations.
• Extendedlocations which aredoubletiered and have
sublocations.
!For both types of locations there are clear visual keypad prompts
whichaid in programmingdata.
!Data contained in some locations is longer than one digit in
length.(ega telephonenumber).Toread the datastoredin these
locations press the [Panic] key.Each time the [Panic] key is
pressed, the keypad will scroll to and display the next digit
programmedin the location.
!Wherea hexadecimalnumbermust beprogrammed utilize the
[MODE] keyas perTable 3below:
eulaVlamicedaxeH3elbaT
eulaVxeH eulaVlamiceD sekortSyeK
A01 ]edoM[ yek]0[nehtyek
B11 ]edoM[ yek]1[nehtyek
C21 ]edoM[ yek]2[nehtyek
D31 ]edoM[ yek]3[nehtyek
E41 ]edoM[ yek]4[nehtyek
F51 edoM[ yek]5[nehtyek]
edoMmargorPgniretnE1.71
1. Ensurethat allpartitionsare unarmed
2. Press the [#] hash key followed by the [INSTALLER CODE].
The default installer code is 9999
3. If a correct code has been entered the green READY indicator

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
14
will flash. Press the [!] star key and a long beep will
confirmentry into programmode.
snoitacoLdradnatSgnimmargorP2.71
1. Ensure the panel is in program mode - the READY indicator will
beflashing.
2. Enterthe [LOCATIONNUMBER] of theprogram locationthatyou
wishto view orchange.
3. Press the [!] star key. The READY indicator will continue
flashing and theAWAY indicator will illuminate.
4. The zone LED’s will display the data stored in the program
locationin binaryformat.
5. Enter the [NEW DATA] followed by the [!] star key.A long beep
will indicate a valid entry and theAWAY indicator will extinguish.
6. If you do not wish to change the data press the [#] key.
The READY indicator will continue flashing and theAWAY
indicatorwill extinguish
7. Repeat steps 2 - 5 untill all the necessary locations have been
programmed.
8. Press the [#] hash key to exit program mode.
9. The READY indicator will stop flashing and the panel will return to
the standby mode.
snoitacoLdednetxEgnimmargorP3.71
1. Ensure that the panel is in program mode - the READY
indicatorwill beflashing.
2. Enter the [LOCATIONNUMBER]of theprogramlocation that you
wishto view orchange.
3. Press the [!]star key. The READY indicator will continue
flashingand theARMED indicatorwillilluminate.
4. Enterthe [SUB LOCATIONNUMBER]for theprogramlocation
that you wish to view or change.
5. Press the [!] star key, a long beep indicates a valid data entry.
The READY indicator will continue flashing and the ARMED and
AWAY indicators will illuminate.
6. Enter the [NEW DATA] followed by the [!] star key.Along beep
will indicate a valid entry. TheAWAY indicator will extinguish.
7. If you do not wish to change the data within this sublocation
press the [#] hash key. The READY indicator will continue
flashing and theAWAY indicator will extinguish.
8. Repeat steps 2 - 6 until all the necessary locations and their
sublocationshavebeenprogrammed.
9. Press the [#] hash key twice to exit from program mode.

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 15
noitacoLdeppamtiBagnimmargorP4.71
1. Abitmapped location allowsthe installerto program multiple
panel features within a single location or sublocation. This is
achievedusing theindividualzone LEDs toindicate which
featuresareenabled or disabled.
2. Byrefering to theappropriate location referencetablesthe
installercan viewthe entire selectionof featuresassociatedwith
that location.
3. An illuminated zone LED indicates that a feature is enabled.An
extinguished LED indicates that a feature is disabled
4. The installer is able to toggle a selected LED indicator ON or OFF
by pressing the corresponding key followed by the [!] star key
5. Oncea completeselection offeatures hasbeen finalized,press
the [!] key to enter the selection to the location.
elpmaxEnA
Location40 onpage 26of thismanual providesus with a good
example of a bitmapped location which will help explain the
programmingmethod employed forsuchlocations.
Location 40 allows the installer to select up to twelve trouble
conditions which can be displayed and reported. By default onlyAC
failtrouble and lowbatterytrouble areenabled.If we enterprogram
mode and then view the contents of Location 40 we will note that the
[1] LED and [5] LED will be illuminated.All other zone LED indicators
will be extinguished. To enable the Comms Fail Trouble Display
(indicated by zone 2 LED) press the 2 key followed by the [!] star key.
A long beep will indicate a valid entry and the 2 zone LED indicator will
illuminateindicating theenabling of theComms FailTroubleDisplay.
Continueselection (ordeselection)of thedesiredtrouble conditions.
Once a final selection has been made enter the [!] star key again to
enter the selection. TheAWAY indicator will extinguish and a long
beep will indicate acceptance of a valid data entry.

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
16
seirtnEataDtcerrocnI5.71
1. When programming eitherstandard or extended locationsany
attempt to enter invalid data will result in three short error beeps of
the keypad buzzer.
2. In the case of standard locations theAWAY indicator will remain
illuminatedafter the errorbeeps.Re-enter thecorrectdata. There
is no need to press the [#] hash key.
3. In the case of extended locations theAWAY andARMED
indicatorswill remain illuminatedafterthe errorbeeps.Re-enter
the correct data. There is no need to press the [#] hash key.
yrammuSnoitacoLgnimmargorP6.71
Below follows a detailed description of each location and its options.
0NOITACOL edoCresUretsaMrolenapehtfognitluafeD
eulaV noitcA
0resullA.seulavtluafedyrotcafehtotsnoitacolllateserlliW ).4321edoCresUretsaM(:detluafedeboslalliwsedoc
1ehttluafedosladna4321otedocresuretsamehttluafedlliW .seitreporpedocresuretsam
snoitpOenoZ1.6.71
61-1SNOITACOL puteSenoZlaudividnI
1NOITACOLBUS epyTenoZ
Program sub-location 1of location 1 - 16 to define the zone
characteristicsof eachofthe sixteenzones. There are12 (twelve)
zonetypes.Table 4providesa location/zone cross-referencetogether
with the default zone characteristics.

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 17
stluafedenoZ/noitacoL4elbaT
coL enoZ tluafeD epyTenoZ
111 tixE/yrtnE
222 rewolloF
334 tnatsnIelbiduA
444 tnatsnIelbiduA
554 tnatsnIelbiduA
664 tnatsnIelbiduA
774 tnatsnIelbiduA
884 tnatsnIelbiduA
990 delbasiD
01010 delbasiD
11110 delbasiD
21210 delbasiD
31310 delbasiD
41410 delbasiD
51510 delbasiD
61610 delbasiD
Table 5 (page18) Provides acomplete listof thedifferentzone types
together with a description of their characteristics.

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
18
sepyTenoZelbammargorP5elbaT
eulaV epyTenoZ
0DELBASID lortnocehtybderongisienozdelbasidafonoitaloivenoZA .dapyekehtnodetacidniebtonlliwdnalenap
1ENOZTIXE/YRTNEYRAMIRP yaledtixeehtgnirudderongieraenoztixE/yrtnEnafosnoitaloiV nehwenoztixE/yrtnEnagnitaloiV.erudecorpgnimraehtfodoirep deretnetonsiedoCresUdilavfI.yaledyrtneehtetaitinilliwdemra eblliwnoitidnocmralana,seripxedoirepyaledyrtneehterofeb gnimraretfaenoztixE/yrtnEnahguorhttixeoteruliaF.deretsiger .mrAyatSotlenapehtesuaclliw
8ENOZTIXE/YRTNEYRADNOCES sienozsihtnehwdetavitcaeblliwyaledyrtneyradnocesehT .demrasilenapehtnehwdetaloiv
2ENOZREWOLLOF eehtgnirudderongisienozrewolloFafonoitaloivA tixe/yrtn
doirepyaled rewollofehtaivtixe/retneotresuehtswollasiht( lenapehtfienoztnatsninasaevaheblliwenozrewolloFA.)enoz detaloivtsriftonsienoztixE/yrtnEnadnademrasi
3ENOZYTIROIRP/CINAP afonoitaloiva,tonrodemrasilenapehtrehtehwfosseldrageR cinaparetsigerotlenaplortnocehtesuaclliwenozytiroirP .noitidnoc
4ENOZTNATSNI lliwenoztnatsninafonoitaloivehtdemrasilenapehtnehW .noitidnocmralanaretsigerotlenaplortnocehtesuac
5ENOZMRASID/MRA otlenapehtesuaclliwenozmrasiD/mrAnafonoitaloivehT -nonrohctiws-yekyratnemomatcennoC.mrasidromrarehtie .enozehtottinulortnocetomergnihctal

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00 19
eulaV epyTenoZ
9ENOZYRTNEREWOLLOF otnommocsienozyrtnenanehwdesusienozyrtnE/rewolloFA rewollofasastcatidemraerasnoititraphtobnehW.snoititrapowt tixe/yrtnenasastcatidemrasidsisnoititrapehtfoenofI.enoz .enoz
01 ENOZERIF fosseldragerdnuosotnerisehtesuaclliwenoZeriFafonoitaloiV dnuoslliwnerisehT.tonrodemrasilenapehtrehtehw noitarepotcerrocroF)ffodnoceseno,nodnoceseno(yltnattimretni rewoprotcetederifasademmargorptuptuoelbammargorpa .rotcetederifehtotrewoplortnocotdesuebtsumtuptuo
11 ENOZREPMAT sseldragernoitatsesabehtotdetropereblliwenozsihtfonoitaloiV demrasilenapehtfI.demrasidrodemrasilenapehtrehtehwfo .detavitcaeblliwneriseht
21 ENOZMRALARUOH42 42afonoitaloiva,lenapehtfoetatsdemraehtfosseldrageR .noitidnocmralanaretsigerlliwenozruoh
31 ENOZGNINRAW esuaclliwenozgninrawafonoitaloiv,demrasilenapehtnehW sititubgoltneveehtnideggolsinoitaloivehT.peebotneriseht detroperton .noitatsesabehtot
41 ENOZMRAOTHSUP lliwyaledtixeehtgnirudenozmraothsupafonoitaloiV .lenapehtmrayletaidemmi
2NOITACOLBUS seitreporPenoZ
Note: Select all the options for each zone.
This is a bitmapped location.
DEL FFO/NO seitreporPenoZ
1NO
delbanEenoZybrepmaT
*FFO
delbasiDenoZybrepmaT
2NO
delbanEenoZssorC
*FFO
delbasiDenoZssorC
3NO
delbanEnwodtuhS
*FFO
delbasiDnwodtuhS
4NO
delbanEenoZtneliS
*FFO
delbasiDenoZtneliS
seulavtluafedsetoneD*

IDS816INSTALLERMANUAL
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00
20
Tamper by Zone
Individualzones maybeenabled fortamperby zone.Seepage 7
Figure2, forconnectiondetails. Thisfeature is notavailable ifzone
doubling is enabled. (See Figure 3, page 8 and Location 38 page 24)
Cross Zoning
Thisfeature isuseful for reducingfalse alarms. Violatingzones with
thecross zoneproperty enabled willnot immediatelygeneratean
alarm.The CrossZone DelayTimer is started.See Location36.
Dependingonthe value programmedintolocation37 (Cross ZoneTrip
Count)the zone(or anyother zone with cross zoneoption enabled)
musttrip thenumber of timesprogrammed intolocation 37 beforean
alarmis generated.Analarm willalso begenerated shouldthe zone
remainviolatedfor theentiredelayperiod.
Swinger Shutdown
Duringa singlearmcycle if thenumber of alarmviolations generated
by a swinger zone equals the shutdown count (Location 33) the control
panel will automatically bypass the that zone.The swinger shutdown
counter is reset either when the system is disarmed and re-armed or
automatically when the 24 hour self test report is generated. See
Sublocation5 ofLocations109 and110[Partition Setup]
Silent Zone Enabled
Thisproperty allowsanyFollower, Instant,Panicand 24HourAlarm
Zone types to be programmed as a silent zone.
sedoCgnitropeRenoZ
Note: For the following locations a two digit hexadecimal code must
beprogrammed.To disableareporting code adouble zero
(00)must beentered.
3NOITACOLBUS edoCgnitropeRmralA
The code transmitted when the zone is violated during an arm cycle or
ifa panicor24 HourZone is violated.
Table of contents
Other Inhep Digital Security Security System manuals

Inhep Digital Security
Inhep Digital Security IDS 400 User guide

Inhep Digital Security
Inhep Digital Security IDS 1600 User guide

Inhep Digital Security
Inhep Digital Security IDS X Series User manual

Inhep Digital Security
Inhep Digital Security IDS 1200 User guide

Inhep Digital Security
Inhep Digital Security IDS 800 User guide

Inhep Digital Security
Inhep Digital Security IDS404 User guide