GB
3. EXPLANATION
The instructions in this manual contain important
information about the safe installation, operation,
cleaning and maintenance of the equipment.
Therefore, keep the manual where the operator
and the technician can reach easily .
The installation of the machine, conversion into
different gas groups and maintenance operations
should be realized by an authorized person
complying with the instructions of the
manufacturer.
The machine should be connected to the gas
supply as per values displayed in’’Technical
Features’’ .
The manufacturer does not accept any liability
from the eventual damages occurred by any
operation not considering the operation manual
and maintenance and technical intervention by
any unauthorised person .
4. INSTALLATION
Position the equipment under a hood which is
capable of sufficient air ventilation in order to
prevent formation of odour and fume .
Remove the protective nylon film on the
equipment by peeling it off. If there are any
remnants of adhesive substance on the equipment,
clean it with a suitable solvent( eg: Henkel-
Helios)
Level the equipment by adjusting the 4 adjustable
feet on an even surface.
Please consider that there is no flammable
product around the equipment .
5. GAS CONNECTION
Connect the equipment to the gas supply through
a metal pipe with a suitable cross-section.
A valve should be positioned to the equipment
inlet in case gas delivery must be stopped.
After all the connections are realized, make a gas
leak check.
Check whether the equipment is suitable for the
gas type connected or not . If not, see the chapter
‘’Conversion to the Different Gases’’ .
All of the necessary parts for the installation will
be supplied by manufacturer.
Gas flex or gas hose connections should be
realized according to the standard of TS EN
14800.
6. CONVERSION INTO DIFFERENT GASES
ATTENTION ! The conversion of the
equipment into different gases should only
be realized by authorised service agents .
The equipment is adjusted to operate under
20mbar NG(G20) gas. If it should be operated
with another gas , then the following procedures
should be realized . Necessary injectors and self-
adhesive labels are delivered in a bag together
with the equipment . TABLE T2
4.1 Changing the burner injectors
Remove cast iron no“1” and the oil pan
no”2”underneath.
Loosen the screw of part “3” by a screwdriver
and move it backward and forward.
Convert the injector “7” according to the gas type
you are going to use on Table 2. Figure 1
4.2 Changing the oven injectors
Remove the part “1” by turning the nut “3”.
Convert the injector “2” according to the gas type
you are going to use on Table T2.
Figure 2