manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. INSECT-O-CUTOR
  6. •
  7. Lawn And Garden Equipment
  8. •
  9. INSECT-O-CUTOR Exocutor EX16 User manual

INSECT-O-CUTOR Exocutor EX16 User manual

This manual suits for next models

3

Other INSECT-O-CUTOR Lawn And Garden Equipment manuals

INSECT-O-CUTOR PRISM User manual

INSECT-O-CUTOR

INSECT-O-CUTOR PRISM User manual

INSECT-O-CUTOR PRISM User manual

INSECT-O-CUTOR

INSECT-O-CUTOR PRISM User manual

INSECT-O-CUTOR Aura User manual

INSECT-O-CUTOR

INSECT-O-CUTOR Aura User manual

INSECT-O-CUTOR Halo Aqua User manual

INSECT-O-CUTOR

INSECT-O-CUTOR Halo Aqua User manual

Popular Lawn And Garden Equipment manuals by other brands

Sunforce SOLAR user manual

Sunforce

Sunforce SOLAR user manual

GARDEN OF EDEN 55627 user manual

GARDEN OF EDEN

GARDEN OF EDEN 55627 user manual

Goizper Group MATABI POLMINOR instruction manual

Goizper Group

Goizper Group MATABI POLMINOR instruction manual

Rain Bird 11000 Series Operation & maintenance manual

Rain Bird

Rain Bird 11000 Series Operation & maintenance manual

Cub Cadet BB 230 brochure

Cub Cadet

Cub Cadet BB 230 brochure

EXTOL PREMIUM 8891590 Translation of the original user manual

EXTOL PREMIUM

EXTOL PREMIUM 8891590 Translation of the original user manual

Snapper 690179 installation instructions

Snapper

Snapper 690179 installation instructions

Exmark SAR481KA30 Operator's manual

Exmark

Exmark SAR481KA30 Operator's manual

Yazoo/Kees Z12 Operator's manual

Yazoo/Kees

Yazoo/Kees Z12 Operator's manual

Makita EM408MP Original instruction manual

Makita

Makita EM408MP Original instruction manual

Exmark Quest Bagger Setup instructions

Exmark

Exmark Quest Bagger Setup instructions

Manitou Systems AS960 Operator's manual

Manitou Systems

Manitou Systems AS960 Operator's manual

Vertex 1/3 HP Maintenance instructions

Vertex

Vertex 1/3 HP Maintenance instructions

GHE AeroFlo 80 manual

GHE

GHE AeroFlo 80 manual

Land Pride Post Hole Diggers HD25 Operator's manual

Land Pride

Land Pride Post Hole Diggers HD25 Operator's manual

Yazoo/Kees Z9 Commercial Collection System Z9A Operator's & parts manual

Yazoo/Kees

Yazoo/Kees Z9 Commercial Collection System Z9A Operator's & parts manual

Premier designs WindGarden 26829 Assembly instructions

Premier designs

Premier designs WindGarden 26829 Assembly instructions

Snapper 1691351 installation instructions

Snapper

Snapper 1691351 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Please read these instructions carefully and store in a safe
place for future reference.
EXOCUTOR™
As part of the Insect-O-Cutor®brand of insect control
products, Exocutor™is an effective and flexible commercial
flykiller which utilises highly effective UV tubes. Available in a
white or stainless steel finish, four sizes of unit are available
which can be wall mounted, ceiling suspended or desk
mounted.
CONTENTS OF PACKAGE
- 1 x Exocutor™flykiller
- 1 x Mains cable (Type X)
- 2 x Screws, wall plugs and suspension keyrings
- 2 x High powered UV tubes (Fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)
INSECT CONTROL PRODUCTS
Exocutor™utilises ultra violet tubes to attract flying insects and
then electrocutes them on a killing grid, before collecting
them in a removable catch tray.
WARNING
Exocutor™is not to be used by persons with reduced physical,
sensory or mental capabilities, or lack of experience and
training, unless they have been given instruction.
Children should be supervised to ensure they do not play with
the appliance.
If the mains cable is damaged it must be replaced by a
specialist mains cable available from P+L Systems Ltd or your
supplier.
Exocutor™must only be used in areas which are free of dust
and any possible explosive vapour mixture, is suitable for
indoor use only and is not suitable for use in barns, stables
and similar locations.
POSITIONING
Exocutor™should ideally be fixed around two meters above
the ground, preferably in the darkest place within the area to
be protected. Do not position the unit close to windows,
skylights or other sources of light, or where it may be
obscured by furniture, doors or other obstacles.
USING EXOCUTOR™
Exocutor™should ideally be in operation for 24 hours a day,
ensuring your premises are kept free of flying insects. Insects
are most attracted to Exocutor™units at night when there is
no competition from daylight or other light sources.
GUARANTEE
Exocutor™has a three year guarantee and if maintained as
recommended in these instructions should continue to work
for many years.* Use of non-approved consumables may
invalidate the guarantee.
*Excludes tubes and starters. Does not cover breakdown due to misuse, incorrect operation
or use in an incorrect application.
INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY SERVICE
PERSONNEL ONLY.
Exocutor™should be mounted as shown in the mounting
options section of this document. Keep out of reach of
children. Use the removable mains lead and plug to connect
Exocutor™to a power supply of appropriate rating, as
specified on the specification label found on the catch tray.
CLEANING
CLEANING SHOULD BE CARRIED OUT BY SERVICE PERSONNEL
ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
It is recommended that cleaning is carried out regularly every
month. During cleaning the unit should be thoroughly wiped
down with a damp cloth, removing any build up of dirt.
Ensure the unit is completely dry before reconnecting it to the
power supply.
Mounting Options
Wall
Desk
Suspended
MOUNTING FIXING CENTRES
METHOD EX16 EX30 EX40 EX80
Wall 174mm 310mm 455mm 455mm
Desk - - - -
Suspended 338mm 488mm 640mm 640mm
EX16, 30, 40 & 80
Professional Electric Insect Control
SPECIFICATION / REPLACEMENT PARTS
Unit EX16
Voltage 230V ~ 50Hz
Dimensions(mm) 390 x 140 x 265
Coverage 50 Sq. Meters
Weight 3.3 Kg
Light Output 16W
Tubes 2 x TPX8-12
Starter 2 x I154
Tray (W / S/S) T-EX16W / T-EX16S
Unit EX30
Voltage 230V ~ 50Hz
Dimensions(mm) 538 x 140 x 265
Coverage 100 Sq. Meters
Weight 4.5 Kg
Light Output 30W
Tubes 2 x TPX15-18
Starter 2 x I154
Tray (W / S/S) T-EX30W / T-EX30S
Unit EX40
Voltage 230V ~ 50Hz
Dimensions(mm) 694 x 140 x 265
Coverage 140 Sq. Meters
Weight 5.6 Kg
Light Output 40W
Tubes 2 x TPX18-24
Starter 2 x I154
Tray (W / S/S) T-EX40W / T-EX40S
Unit EX80
Voltage 230V ~ 50Hz
Dimensions(mm) 694 x 140 x 265
Coverage 280 Sq. Meters
Weight 5.7 Kg
Light Output 80W
Tubes 2 x TPX36-24
Starter 2 x I154
Tray (W / S/S) T-EX40W / T-EX40S
Tube ReplacementStarter Replacement
CATCH TRAY REMOVAL
The catch tray is connected to the power supply of the unit via a hidden switch. By
removing the catch tray, the connection is broken and power is cut to the unit. This
ensures safe access to the unit for servicing and cleaning.
NB - WHEN REPLACING THE CATCH TRAY BACK INTO EXOCUTOR™, ENSURE IT IS PUSHED
FULLY INTO POSITION AND THAT POWER IS RESTORED TO THE UNIT.
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of Exocutor™in catching flying insects, the UV tubes should
be replaced annually. After twelve months the phosphor coating that emits the
correct wavelength of UV light has burnt away and the UV output is diminished
substantially.
To replace the UV tubes…
1. Remove the catch tray, breaking the power supply to the unit.
2. Rotate the tube through 90°, freeing it from the tube holders.
3. Pull the tube away from the chassis.
4. Dispose of the used UV tubes in conjunction with local WEEE regulations.
STARTER REPLACEMENT
STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY,
AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tubes. Starters wear out
and should be replaced at the same intervals as the UV tubes.
To replace the starters…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.
R3 03/14
C2014
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
WEEE Compliance No. WEE/GF0661QR