INSECT-O-CUTOR Halo Aqua User manual

Halo Aqua
Please read these instructions carefully and store in a safe place for
future reference.
HALO
As part of the Insect-O-Cutor®brand of insect control products, Halo is
a versatile professional flykiller which utilises highly effective UV tubes and
is designed for use with a high specification glupac®glueboard. Halo is
available as a 15, 30 or 45W model which can be wall or desk mounted,
and a 2x30w model for ceiling suspension. Halo Aqua is a 45w IP45 rated
model, which is designed for use areas which require hosing down.
CONTENTS OF PACKAGE
- 1 x Halo Aqua flykiller
- 1x Glupac®pheromone impregnated glueboard
- 1 x Removable aluminium debris tray
- 2 x High powered shatterproof UV tubes
- 4 x Screws and wall plugs
- 2 x Vertical mount glueboard retaining pins
- 1 x Servicing key fob and mains cable tidy tie wrap wire
WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)
INSECT CONTROL PRODUCTS
Halo Aqua utilises high powered ultra violet tubes to attract flying insects
and retains the caught insects on a pheromone impregnated glueboard
for inspection or hygienic disposal.
WARNING
Halo Aqua is IP45 rated and is designed for use in applications
appropriate to this ingress protection rating.
Halo Aqua is not to be used by children or persons with reduced
physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction.
Children should be supervised to ensure they do not play with the
appliance.
Halo Aqua is not suitable for applications where potentially explosive
environments may exist.
POSITIONING AND GUIDANCE FOR USING HALO
THIS UNIT IS FOR INDOOR USE ONLY.
Halo Aqua should ideally be fixed around two meters above the ground,
preferably in the darkest place within the area to be protected. ENSURE
THERE IS A MINIMUM OF 550mm BETWEEN ONE SIDE OF HALO AND THE
ADJACENT SURFACE, TO PROVIDE ENOUGH SPACE TO INSERT THE
GLUEBOARD (SEE MOUNTING INSTRUCTIONS.) Do not position the unit
close to windows, skylights or other sources of light, or where it may be
obscured by furniture, doors or other obstacles. Ideally, Halo Aqua
should be visible from every part of the area to be protected.
Halo Aqua should ideally be in operation for 24 hours a day, ensuring
your premises are kept free of flying insects. Insects are most attracted
to Halo Aqua at night when there is no competition from daylight or
other light sources.
*Excludes tubes, glueboards and starters. Does not cover breakdown due to misuse, incorrect
operation or use in an incorrect application.
GUARANTEE
Halo Aqua has a three year guarantee and if maintained as
recommended in these instructions should continue to work for many
years.* Use of non-approved consumables may invalidate the
guarantee. Ensure genuine glupac®glueboards are used in conjunction
with this product.
INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY.
For wall mounting, use the supplied wall mounting plugs and screws,
making sure correct wall plugs are used for specialist mounting materials,
such as plasterboard.
Wall Mounting - Halo Aqua can be wall mounted horizontally or
vertically. For horizontal mounting, use the two cut outs on the debris
tray to mark the correct wall mounting points. For vertical wall
mounting, insert the two large plastic glueboard retaining pins in the two
holes on the glueboard runners, to stop the glueboard falling out of the
unit. (Supplied in the fixing kit)
Once Halo Aqua is installed in position, fit the glupac®glueboard in
place as described in the glueboard replacement section of this
document. Halo Aqua should be hardwired into an appropriate power
supply (as indicated on the specification label) by a qualified
electrician. Use the supplied black mains cable tidy tie wrap wire to
hide any excess mains cable behind the product if required.
To maximise the effectiveness of Halo Aqua in catching flying insects,
the top of moulding has light apertures to increase the UV irradiance
emitted from the product. However, if required, these apertures can be
covered to protect the glueboard from debris and prolong its life, by
simply sliding the reflective aluminium cover forward.
CLEANING
CLEANING SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY,
AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS
SUPPLY.
It is recommended that cleaning is carried out regularly when the
glueboard is replaced. Once the glueboard is removed, the unit should
be thoroughly wiped down with a damp cloth, removing any build up of
dirt. Ensure the unit is completely dry before reconnecting it to the
power supply.
Wall Mounting
Professional Glueboard Insect Control
Light Apertures &
Cable Management

Tube Replacement
Starter Replacement
SPECIFICATION / REPLACEMENT PARTS
Unit Halo Aqua 45
Voltage 230V ~ 50Hz
Dimensions(mm) 588 x 404 x 118
Coverage 120 Sq. Meters
Weight 7.0 Kg
Light Output 45W
Tubes 3 x TPX15-18S
Starter 3 x I154
Glueboards (x6) GB013 (Yellow)
GLUEBOARD REPLACEMENT
GLUEBOARD REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac®glueboard. Use of
non-approved glueboards may invalidate your guarantee. Halo Aqua comes supplied with
high efficacy replacement yellow glueboards, with printed grids for simple insect evaluation
and monitoring.
To replace the glueboard…
1. Remove the used glupac®glueboard by simply pulling it clear from either the left or
right of the unit.
2. Remove the protective release paper from the new glupac®glueboard.
3. Slowly slide the new glupac®glueboard into position, until the glueboard ‘drops’ into
the locator, indicating it is in the centre of the unit.
Always ensure the selected genuine glupac®glueboards are compatible with your unit,
available from your pest control operator or Pelsis Ltd.
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING
THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of Halo Aqua in catching flying insects, the UV tubes should be
replaced annually. After twelve months the phosphor coating that emits the correct
wavelength of UV light has burnt away and the UV output is diminished substantially.
To replace the UV tubes…
1. Open the swing down front guard, by using the supplied servicing key fob.
2. Loosen the lampholder cap slightly, then rotate the lampholder anticlockwise
3. Repeat the process on the opposite lampholder, then slide them both towards the
centre of the tube
4. Rotate the tube through 90°, freeing it from the tube holders.
5. Pull the tube away from the chassis.
6. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING
THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tubes. Starters wear
out and should be replaced at the same intervals as the UV tubes.
To replace the starters…
1. Release the starterholder cap by unscrewing it anticlockwise.
2. Rotate the starter anti-clockwise.
3. Pull the starter free from the unit.
Glueboard Replacement
R2 03/15
C2015
Pelsis Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pelsis.com
WEEE Compliance No. WEE/GF0661QR

Halo Aqua
Professional Glueboard Insect Control
MOUNTING INSTRUCTIONS
340mm
B
A
A
D
B
C
550mm
(MINIMUM)
R2 03/15
www.pelsis.com
Other INSECT-O-CUTOR Lawn And Garden Equipment manuals
Popular Lawn And Garden Equipment manuals by other brands

Click & Grow
Click & Grow 25 manual

Rutland County Garden Furniture
Rutland County Garden Furniture The Wall Mounted Box Pergola & Decking Kit Assembly instructions

VEVOR
VEVOR HL11351 instructions

Brinno
Brinno GardenWatchCam user guide

Steen QOS
Steen QOS Horneet GF-7CN Instruction for operation and maintenance

Fimco
Fimco TC-12-P Assembly / Parts