Technical Specification Update Table of Contents
Table of Contents
I. Preface......................................................................................................................6
1Nomenclature .........................................................................................................6
2Product Scope........................................................................................................7
II. Summary Tables......................................................................................................8
III. Errata......................................................................................................................10
1Memory Mirroring Not Supported by the System BIOS ........................................10
2Microsoft Windows* 2003 operating system shows 2 monitors in Device Manager.10
3Some RAID controllers fail to recognize their Option ROM access hot-key sequence
needed to configure the card during POST ................................................................10
4Platform Confidence Test (PCT) reports SIO error when no floppy drive is present11
5Unknown Interrupt Error Message during POST ..................................................11
6COM Port B Ring Indicator not terminated correctly.............................................11
7BMC SEL Timestamp Incorrect Information .........................................................12
8Current BIOS does not support Legacy Mode for the on-board Serial ATA (SATA) ports
12
9Non-threshold base sensors mBMC responds threshold value............................12
10 LM93 sensor monitoring issue...........................................................................13
11 The silk screen identifying the PCI Slot numbers on the Low Profile PCI riser card for the
SR2400 is not consistant with silk screen of the Full Height PCI-X (passive) riser card.13
12 CPU 2 Processor Fault LED illuminated when no processor is installed ...........14
13 Silk screen for onboard SCSI Channels denote the internal SCSI connector as Channel
A and the external SCSI connector as Channel B. However, LSI firmware recognizes them in
opposite order.............................................................................................................14
14 Blinking Green Status LED Associated with FRUSDR 6.6.8 and Earlier on
S7520JR2ATAD2 Server Boards................................................................................14
IV. Documentation Changes ......................................................................................16
1SATA drive activity LED is driven by both the backplane controller and the Hard Drives
16
2Incorrect description of 50-pin front panel connector as J1J2...............................16
3Incorrect pin assignment for table 90 “OEM RMC Connector Pinout (J3B2)”.......16
4Incorrect measurement for table 1 “Chassis Dimentions” on TPS........................17
5Power module must be inserted into the top slot of the power module enclosure in single
power module configuration........................................................................................17
6Memory error handling mechanism in BIOS is changed.......................................17
73-pin cable in SR1450 SATA Backplane Kit is not used with the onboard SATA controller
18
V. FYI – Useful Information .......................................................................................20
1Onboard CTRL <C> RAID 0, 1 creation appears to be slow and appears to limit the
number of RAID configurations...................................................................................20
2BIOS will display a warning message when the mBMC System Event Log (SEL) is full
20
3ID Button/LED functionality with no Intel Management Module (IMM)..................21
4mBMC doesn't log the "AC Lost" event when AC power lost................................21
iii