FG-1525R/FG-1525RT Glassbreak Detector Supplemental Information
Protected glass:
Minimum size for all types is 11 inches (28 cm) square. Glass must be
framed in the wall of the room or mounted in a barrier of 36 inches (0.9 m)
minimum width.
1Protected only if both glass plates are broken.
2Coated glass with security films, including films for solar protection, up to 12 mil.
thick may be used. Film Technologies International, Inc.s GLASS-GARD GGLL 1200
has been e aluated with this product by Underwriters Laboratories, Inc. at
IntelliSenses request.
3In compliance with Underwriters Laboratories of Canadas Standard for Intrusion
Detection Units (CAN/ULC-S306-M89), ULC recognizes a maximum range for
protecting sealed and insulated glass of 3.8 m (12.5 ft).
IMPORTANT: The FG-1525R/RT must be connected to a UL listed power
supply or UL listed control unit capable of pro iding a minimum of four
hours of standby power.
LED INDICATORS
The two LEDs on the front co er indicate the detector's operational
status. The following table summarizes the LED operation when the
LEDs are enabled.
SELF TESTS
The FG-1525R/RT automatically performs a series of self-tests during
power-up. If any self-test fails, the detector signals trouble by flashing
the LEDs alternately once per second. Protection continues if possible.
Always return the detector for repair if there is any indication of trouble,
e en if the trouble is temporary.
LOCATION GUIDELINES
The FG-1525R/RT detects framed glass broken by an impact sufficient
to make a hole. Refer to the following guidelines when selecting a
mounting location:
•The FG-1525R/RT can be mounted in corners, on walls, and on
ceilings.
•Mount within 25 (7.6 m) of the glass.
•There is no minimum range, but the detector must ha e a clear line-
of-sight and a clear iew of the glass.
•The ideal location is on the wall or ceiling directly opposite the glass.
The least desirable location is on the same wall as the glass.
•When wall mounting, mount the detector a minimum of 6 (1.8 m) high.
•Curtains, blinds and other window co erings absorb energy from
breaking glass. Hea y curtains, for example, effecti ely block the
sound signal. In these cases, mount the detector on the window frame
behind the window co ering or abo e the window.
•Do not mount within 3 (0.9 m) of forced air ducts, sirens, or bells
measuring 2 (5 cm) or more in diameter.
•Minimize range to the glass. Do not install beyond the maximum
specified range e en if testing indicates greater range.
•Adjust sensiti ity for desired range; erify by testing with the FG-701.
•Mounting on freestanding posts and pillars is not recommended.
•Verify all installations back to the panel to be sure the protection loop
is intact.
•Do not use outside.
•A oid installing in rooms with high-le el noise sources, such as air
compressors, bells, and power tools if those sources can be acti e
when the detector can signal an alarm.
•Test false alarm immunity by acti ating any noise sources in the room.
Note: The FG-1525R/RT detects shattering of framed glass by a direct
impact. It may not consistently detect breakage by blows that only crack
the glass, by high elocity projectiles (such as bullets) or if the glass is
broken without an impact.
SPECIFICATIONS
Range:
25 feet (7.6 m) maximum
No minimum range
Alarm relay:
FG-1525R Form A
FG-1525RT Form C
125 mA maximum
25 VDC maximum
Alarm duration:
5 seconds (unaffected by alarm LED latching)
Tamper switch: (FG 1525RT only)
Combination co er and wall tamper
25 mA maximum
24 VDC maximum
Power requirements:
6 - 18 VDC; 12 mA typical at
12 VDC, 22 mA max.;
Operating temperature:
14° to 120°F (-10° to 50°C)
Storage: -4° to 122° F (-20° to 50° C)
RFI immunity:
30 V/m, 10 MHz - 1000 MHz
ESD immunity:
10 kV, Discharges of either polarity to exposed surfaces
Dimensions:
4.25 OD x 0.88 THK
(108 mm x 22.4 mm)
Weight:
4.5 oz., (128 g)
Packaged product: 7.5 oz., (213 g)
Accessories:
FG-701 Glassbreak Simulator
FG-SP2 Spacer Plate
Approvals/Listings:
FCC and IC Verified
UL Listed
ULC Listed
FCC Notice: This equipment has been tested and found to comply with the limits for a Class B digital
de ice, pursuant to part 15 of the FCC Rules. These limits are designed to pro ide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy, and if not installed and used in accordance with the instructions may cause
harmful interference to radio communications. Howe er, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or tele ision
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures: 1) Reorient or relocate the recei ing
antenna, 2) Increase the separation between the equipment and recei er, 3) Connect the equipment into an
outlet on a circuit different from that to which the recei er is connected. The installer can also consult an
experienced radio/tele ision technician for additional suggestions, if necessary.
IC Notice: This digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations. Cet appareil numerique de la Classe B respecte toutes les exigences du Reglement sur le
materiel brouilleur du Canada.
USING THE CEILING/WALL TAMPER SWITCH (FG 1525RT ONLY)
The FG-1525RT has a combination normally-closed (NC) co er and
wall tamper. Each detector is shipped with the co er tamper opera-
tional and the ceiling/wall tamper disabled.
• Use needle-nose pliers to break out the plastic tab on the back of
the detector. The tamper arm then extends through the hole.
THICKNESS
Type Minimum Maximum
Plate33/32" (2 mm) 3/8" (10 mm)
Tempered 1/8" (3 mm) 3/8" (10 mm)
Laminated11/8" (3 mm) 9/16" (14 mm)
Wired 1/4" (6 mm) 1/4" (6 mm)
Coated21/8" (3 mm) 1/4" (6 mm)
Sealed Insulating1,3 1/8" (3 mm) 1/4" (6 mm)
(5/8 o erall)
AC Ripple: 4 Volts peak-to-peak at
nominal 12 VDC
•The tamper screw (not pro ided)
should be a flat-head #8 (M4) or
#10 (M5) screw.
•Install the tamper screw so it will
just make contact with the bottom
of the mounted detectors tamper
ca ity.
•After installing the tamper screw,
position the detector o er it and
mark the locations for the
mounting screws. Install screw to seat in tamper cavity
Rear Housing
Tamper
Cavity
M 4 or M 5
Screw
(#8 or #10)
9.78 mm
(.385 in)
Normal OFF OFF
Normal, e ent detected Flicker OFF
Normal, break detected OFF ON 5 seconds
Normal, alarm latched OFF ON continuously
Power up ON 1 second ON 1 second
Low oltage Flash ON/OFF Flash ON/OFF
Test Mode Flash once per second OFF
Test Mode, e ent detected Flicker OFF
Test Mode, alarm Flash once per second ON 5 seconds
Condition Green LED Red LED