Interroll i Series User manual

Instruction manual
Interroll Drum motor
i-Series
S-Series
S/A-Series
D-Series
Version 4.1 (06/2015) en-US
Translation of original instruction manual

Version 4.1 (06/2015) en-US
Translation of original instruction manual

Interroll Drum motor series i, S, S/A, D
Version 4.1 (06/2015) en-US
Translation of original instruction manual
3
Table of Contents
Introduction 7
Information about the manual 7
Contents 7
The instruction manual is part of the product 7
Warning notices in this manual 7
Symbols 8
Safety 9
State of the art 9
Intended use 9
Unintended use 9
Personnel qualification 10
Operators 10
Service personnel 10
Electricians 10
Dangers 10
Bodily injury 10
Electricity 10
Oil 10
Rotating parts 10
Hot motor parts 11
Working environment 11
Faults during operation 11
Maintenance 11
Accidental motor start 11
Interfaces to other devices 11
General technical information 12
Product description 12
Options 12
Technical data 13
Product identification 13
Thermal protection 14
Standard design: Temperature limiter, automatically switching back 14
Optional version: PTC (positive temperature coefficient) 15
Use of 50-Hz motors on 60-Hz supply system 15
Effect of using a motor with 50-Hz rated motor voltage on a 60-Hz
supply system 15
Effect of using a motor with 50-Hz rated motor voltage on a 60-Hz
supply system with 15/20 % higher voltage 16
i-series product information 17
Type plate of i-series drum motor 17

Interroll Drum motor series i, S, S/A, D
Table of Contents
4
Version 4.1 (06/2015) en-US
Translation of original instruction manual
Electrical data of i-series 19
80i 3-phase 19
113i 3-phase 20
138i 3-phase 22
165i and 217i* 3-phase 23
217i 3-phase 25
Dimensions of i-series drum motor 28
Connection diagrams for the i-series 29
Cable connections 29
Connections in the terminal box 32
S-series product information 37
Type plate of S-series drum motor 37
Electrical data of S-series 39
80S 1-phase 39
80S 3-phase 39
113S 1-phase 39
113S 3-phase 40
Dimensions of S-series drum motor 42
Connection diagrams for the S-series 44
Cable connections 44
Connections in the terminal box 46
S/A-series product information 47
Type plate of S/A-series drum motor 47
Electrical data of S/A-series 48
113S/A 1-phase 48
113S/A 3-phase 48
Dimensions of S/A-series drum motor 49
Connection diagrams for the S/A-series 50
Cable connections 50
Connections in the terminal box 51
D-series product information 53
Type plate of D-series drum motor 53
Electrical data of D-series 54
Dimensions of D-series drum motor 55
Connection diagrams for the D-series 56
Cable connections 56
Encoder connection 57
Options and accessories 59
Electromagnetic brake for the i-series 59
Brake rectifiers for i-series 61
Brake rectifier connections 61
Brake rectifier dimensions 63
Asynchronous drum motors with frequency inverters 65
Torque dependent on input frequency 65
Frequency inverter parameters 65

Interroll Drum motor series i, S, S/A, D
Version 4.1 (06/2015) en-US
Translation of original instruction manual
5
Encoder type BMB-6202 & 6205 SKF for the i-series 67
Technical data 67
Connections 68
Best connection option 69
Encoder type RM44-RLS for the i and D-series 70
Technical data 70
Connections 71
Signal connection 71
Resolver type RE-15-1-LTN 72
Connections 72
Technical data 72
Impedance 73
Transport and storage 74
Transport 74
Storage 75
Assembly and installation 76
Warning notices concerning the installation 76
Installing the drum motor 76
Positioning the drum motor 76
Installing the motor with mounting brackets 77
Installation considering hygienic aspects 79
Belt assembly 79
Belt width / tube length 79
Belt adjustment 79
Tensioning the belt 80
Belt tension 81
Belt elongation 81
Measuring the belt elongation 82
Calculating the belt elongation 82
Drum coating 83
Sprockets 83
Warning notices concerning the electrical installation 84
Electrical connection of the drum motor 84
Connecting the drum motor – with a cable 84
Connecting the drum motor – with a terminal box 84
Single-phase motor 84
External motor protection 85
Integrated thermal protection 85
Frequency inverter 85
Backstop 85
Electromagnetic brake 86
Initial startup and operation 88
Initial startup 88
Checks before the initial startup 88
Operation 89
Checks before every startup 89
Procedure in case of accident or fault 89

Interroll Drum motor series i, S, S/A, D
Table of Contents
6
Version 4.1 (06/2015) en-US
Translation of original instruction manual
Maintenance and cleaning 90
Warning notices concerning maintenance and cleaning 90
Preparation for maintenance and cleaning by hand 90
Maintenance 90
Checking the drum motor 90
Relubricating the drum motor 90
Maintaining drum motors with optional, relubricating IP66 seals 90
Oil change at drum motor 91
Oil types 92
Oil quantities for the i-series in liters (standard installation) 93
Oil quantities for the i-series (vertical installation) 94
Cleaning 94
Cleaning the drum motor with pressure washer 94
Hygienic cleaning 95
Troubleshooting 96
Troubleshooting 96
Decommissioning and disposal 106
Shutdown 106
Disposal 106
Appendix 107
Warranty for Interroll drum motors 107
Restrictions 107
Exceptions 107
List of abbreviations 108
Electrical data 108
Connection diagrams 109
Color coding 109
Installation declaration 111

Interroll Drum motor series i, S, S/A, D
Version 4.1 (06/2015) en-US
Translation of original instruction manual
7
Introduction
Information about the manual
In this instruction manual, the following drum motor types are described:
• 80S, 113S
• 113S/A
• 80i, 113i, 138i, 165i, 217i
• 80D, 88D, 113D
This instruction manual contains important notes and information about the various operating
phases of the drum motor:
The instruction manual describes the drum motor as it is delivered by Interroll.
In addition to this instruction manual, special contractual agreements and technical documents
apply to special versions.
4For trouble-free, safe operation and warranty claims, read the instruction manual first and
follow the instructions.
4Keep the instruction manual close to the drum motor.
4Pass the instruction manual on to any subsequent operator or occupant.
4NOTICE! The manufacturer does not accept any liability for faults or defects due to
non-observance of this instruction manual.
4If you still have questions after reading the instruction manual, please contact Interroll
customer service. Contact persons close to you can be found on the Internet under www.
interroll.com/contacts.
Warning notices in this manual
The warning notices refer to risks which may arise while using the drum motor. They are
available in four danger levels with the following callouts:
Signal word Meaning
DANGER Identifies a danger with high risk that can lead to death or serious injury if it
is not avoided.
WARNING Identifies a danger with medium risk that can lead to death or serious injury
if it is not avoided.
CAUTION Identifies a danger with low risk that can lead to minor or medium injury if it
is not avoided.
NOTICE Identifies a danger that can lead to property damages.
Contents
The instruction manual is
part of the product

Interroll Drum motor series i, S, S/A, D
Introduction
8
Version 4.1 (06/2015) en-US
Translation of original instruction manual
Symbols
This symbol marks useful and important information.
Requirement:
RThis symbol represents a prerequisite to be met prior to assembly and maintenance work.
4This symbol marks the steps to be carried out.

Interroll Drum motor series i, S, S/A, D
Version 4.1 (06/2015) en-US
Translation of original instruction manual
9
Safety
State of the art
The conveyor is designed according to the state of the art and is reliable in operation, once
distributed. However, risks may still arise.
Disregarding the notices in this manual may lead to serious injury.
4Carefully read the manual and follow its content.
Intended use
The drum motor is intended for use in industrial environments, supermarkets and airports and is
used for transporting general cargo, such as parts, cardboard boxes or boxes, as well as
transporting bulk material such as granular material, powder and other fluid materials. The drum
motor must be integrated into a conveyor module or conveyor system. Any other use is
considered inappropriate.
Use of the drum motor is only allowed in the areas described in the product information chapter.
Any modifications that affect the safety of the product are not permitted.
The drum motor may only be operated within the defined operating limits.
Unintended use
The drum motor must not be used for transporting people.
The drum motor is not intended for use under impact or shock loads.
The drum motor is not designed to be used under water. Such a use leads to personal or fatal
injuries from electrocution as well as the penetration of water, resulting in a short circuit or motor
damage.
The drum motor may not be used as a drive for cranes or lifting devices or for the
corresponding hoist ropes, cables or chains.
Use of the drum motor for anything other than the intended purpose is subject to approval by
Interroll.
Unless otherwise stated in writing and/or specified in a quote, Interroll and its dealers shall
assume no liability for product damage or failure which result from failure to observe these
specification and restrictions (see the chapter "Electrical data" of the respective series).

Interroll Drum motor series i, S, S/A, D
Safety
10
Version 4.1 (06/2015) en-US
Translation of original instruction manual
Personnel qualification
Unqualified personnel cannot recognize risks and, as a result, is subject to greater dangers.
4Authorize only qualified personnel with the activities described in these operating instructions.
4The operating company must ensure that the personnel follows locally applicable regulations
and rules during their work with regard to safety and dangers.
The following target groups are addressed in these operating instructions:
Operators have been instructed in operating and cleaning the drum motor and follow the safety
guidelines.
The service personnel features a technical training or has undergone training by the
manufacturer and performs the maintenance and repair tasks.
Persons working on electrical equipment must have undergone technical training and training
provided by the manufacturer.
Dangers
The following list informs you about the various types of danger or damage that may occur
while working with the drum motor.
4Maintenance or repair work must only be executed by authorized and qualified persons in
accordance with the applicable regulations.
4Before turning on the drum motor, ensure that no unauthorized persons are near the
conveyor.
4Only perform installation and maintenance work after you have switched off the power.
Ensure that the drum motor cannot be turned on accidentally.
4Do not ingest the oil. In general, the oil used is relatively non-toxic, but it can still contain
hazardous substances. Ingestion can lead to nausea, vomiting and/or diarrhea. Generally,
medical care is not required, unless large quantities have been ingested. Nevertheless, a
physician should be consulted.
4Avoid skin and eye contact. Prolonged or repeated skin contact without proper cleaning can
clog the pores of the skin and lead to skin problems such as oil acne and folliculitis.
4Wipe up spilled oil as quickly as possible to avoid slippery surfaces. Ensure that oil does not
reach the environment. Properly dispose of dirty rags or cleaning materials to avoid self-
ignition and fires.
4Extinguish oil fires with foam, spraying water or water mist, dry chemical powder or carbon
dioxide. Do not extinguish with water jet. Wear suitable protective clothing, incl. breathing
mask.
4Observe the corresponding certificates at www.interroll.com.
4Do not reach into areas between drum motor and conveyor belts or roller chains.
4Tie long hair together.
4Never wear loose clothing.
Operators
Service personnel
Electricians
Bodily injury
Electricity
Oil
Rotating parts

Interroll Drum motor series i, S, S/A, D
Safety
Version 4.1 (06/2015) en-US
Translation of original instruction manual
11
4Never wear jewelery, such as necklaces or bracelets.
4Do not touch the surface of the drum motor. It can result in burns, even under regular
operating temperature.
4Do not use the drum motor in explosive atmospheres.
4Remove equipment or material which is not required from the workspace.
4Wear safety shoes.
4Clearly specify and monitor the way materials are placed on the conveyor.
4Regularly check the drum motor for visible damage.
4In case of fumes, unusual noise or blocked or damaged materials, stop the drum motor at
once and ensure that the RollerDrive cannot be started accidentally.
4Contact qualified personnel immediately to find the source of the fault.
4During operation, do not step on the drum motor or the conveyor/the system in which it is
installed.
4Check the product regularly for visible damages, unusual noise and firm seating of fittings,
screws and nuts. An additional maintenance is not required.
4Do not open the drum motor.
4Take care during installation and maintenance work or in the event of a drum motor fault:
The drum motor could start up unintentionally.
Interfaces to other devices
Hazards may occur while integrating the drum motor into a complete system. These are not part
of this manual and have to be analyzed during the design, installation and startup of the
complete system.
4After assembling the drum motor in a conveyor module, check the whole system for a new
potential dangerous spot before switching on the conveyor.
4Additional constructive measures may be required.
Hot motor parts
Working environment
Faults during operation
Maintenance
Accidental motor start

Interroll Drum motor series i, S, S/A, D
12
Version 4.1 (06/2015) en-US
Translation of original instruction manual
General technical information
Product description
The drum motor is a completely enclosed electrical drive roller. It replaces external components
such as motors and gears, which require frequent maintenance.
The drum motor can be used in environments with high coarse and fine dust exposure as well as
exposed to water jets and spraying water and is resistant to most of the aggressive ambient
conditions. In aggressive environments and environments with salt water, only stainless steel
motors should be used. Thanks to protection classification IP66 or IP69k and its stainless steel
design (upon request), the drum motor is also suitable for use in the food processing industry and
pharmaceutical industry as well as for applications with high hygienic demands. The drum motor
can be used without as well as with a drum coating to increase the friction between drum motor
and conveyor belt or with profile coating for the drive of form-fit driven belts.
The drum motors of series S, S/A and i are driven by an asynchronous three-phase induction
motor. It is available in different power stages and for most of the international supply voltages.
The drum motors of the D-series are driven by a synchronous motor and must be connected to a
suitable drive control unit. For additional information about the drive control unit, see the
respective manual.
The drum motor contains oil as lubricant and coolant which dissipates the heat via the drum and
the conveyor belt.
If an asynchronous drum motor without belt or with a form-fit driven belt is used, a special
design is available to ensure cooling.
Integrated thermal overload protection: A thermal cut motor protection switch integrated in
the winding head protects against overheating. The switch trips if the motor overheats. However,
it has to be connected to a suitable external control device that interrupts the current supply to
the motor in case of overheating (See "Thermal protection", page 14).
Integrated electromagnetic brake: The integrated electromagnetic brake can hold loads. It
acts directly on the rotor shaft of the drum motor and is controlled by a rectifier. The holding
force of each drum motor with brake has to be calculated first and does not always correspond
to the belt pull of the motor. The electromagnetic brake is available for all drum motors of the
i-series (See "Electromagnetic brake for the i-series", page 59).
Mechanical backstop: The mechanical backstop attached to the rotor shaft and, for 80i, in the
cover, can be used for ascending conveyors. It prevents the belt from running in reverse direction
in case of a power failure. The mechanical backstop is available for all drum motors, except
113s and the D-series.
Encoder: The signal of the encoder can be used for position determination and for controlling
the speed and rotational direction (See "Options and accessories", page 59).
Options

Interroll Drum motor series i, S, S/A, D
General technical information
Version 4.1 (06/2015) en-US
Translation of original instruction manual
13
Technical data
Protection classification IP65 (S/A-series)
IP66 (i and S-series)
IP69k (D-series)
Ambient temperature range for
standard applications 1)
+5 °C to +40 °C
Ambient temperature range for low-
temperature applications 1)
-25 °C to +15 °C
Ambient temperature range for
reduced drum motors 1)
+5 °C to +25 °C
Cycle times max. 3 starts/stops per hour 2)
Ramp times i-series: ≥ 0.5 s
S-series: ≥ 1 s
D-series: ≤ 0.5 s
Installation altitude above sea level Max. 1000 m
1) Depending on the ambient temperature, different types of oil are required (See "Oil types",
page 92). For ambient temperatures below +1 °C, Interroll recommends a standstill heater
and special cables.
2) Higher cycle times with more than 3 starts/stops per hour are possible only if the motor
displacements are implemented absolutely backlash-free. Interroll recommends using frequency
inverters (FI) with set run-up or run-down ramps or special designs.
Product identification
The information given below is required in order to identify a drum motor. The values for a
specific drum motor can be entered in the last column.
Information Possible value Own value
Type plate of drum
motor
Motor type
Speed in m/s
Serial number
Tube length in mm
Number of poles
Power in kW
Drum diameter
(tube diameter)
e.g.
112.3 mm drum ends
113.3 mm drum center
Cover material e.g. rubber, thickness, profile

Interroll Drum motor series i, S, S/A, D
General technical information
14
Version 4.1 (06/2015) en-US
Translation of original instruction manual
Thermal protection
Under normal operating conditions, the thermal circuit breaker integrated in the stator winding is
closed. When the motor limit temperature is reached (overheating), the switch opens at a preset
temperature to prevent damage to the motor.
WARNING
The thermal circuit breaker is automatically reset after the motor has cooled off.
Inadvertent start-up of the motor
4Connect the thermal circuit breaker in series with a suitable relay or contactor so that the
current supply to the motor is safely interrupted when the switch trips.
4Ensure that the motor can be switched on again after overheating only with a confirmation
button.
4After the switch has tripped, wait until the motor is cooled off, and ensure prior to switch-on
that no dangers to other persons are present.
Service life: 10,000 cycles
AC cos φ= 1 2.5 A 250 V AC
cos φ = 0.6 1.6 A 250 V AC
DC 1.6 A 24 V DC
1.25 A 48 V DC
Service life: 2000 cycles
AC cos φ= 1 6.3 A 250 V AC
Switch-back temperature 40 K ± 15 K
Resistance < 50 mΩ
Contact bounce time < 1 ms
Standard design:
Temperature limiter,
automatically switching
back

Interroll Drum motor series i, S, S/A, D
General technical information
Version 4.1 (06/2015) en-US
Translation of original instruction manual
15
PTC
Maximum operating voltage W 25
Thermal time constant s < 10
Resistance at switching temperature + 15 K Ω 1330 ... 4000
+ 5 K Ω 550 ... 1330
Ω 550
- 5 K Ω 250 ... 550
- 20 K Ω < 250
In particular, if the motor does not have an internal thermal winding protection, a suitable
external thermal control relay/contactor must be connected upstream.
A thermal winding protection does not replace the overcurrent protection. In addition, every
motor must be connected to a suitable overcurrent protection which is set to the rated motor
current.
Use of 50-Hz motors on 60-Hz supply system
This option is not available for the D-series.
Rated motor voltage: 230/400 V - 3 ph - 50 Hz
System voltage: 230/400 V - 3 ph - 60 Hz
If a 50-Hz motor is connected to a 60-Hz supply system, the frequency increases and, as a
result, the speed by 20 %. Since the torque decreases accordingly, the motor output remains
constant. The voltage-dependent parameters change in the speed range under field control at
60 Hz according to the following table:
System voltage = rated motor voltage
Power P kW 100 %
Rated speed nn1/min 120 %
Rated torque MnNm 83.3 %
Starting torque MANm 64 %
Pull-up torque MSNm 64 %
Pull-out torque MKNm 64 %
Rated current INA 95 %
Optional version: PTC
(positive temperature
coefficient)
Effect of using a motor
with 50-Hz rated motor
voltage on a 60-Hz supply
system

Interroll Drum motor series i, S, S/A, D
General technical information
16
Version 4.1 (06/2015) en-US
Translation of original instruction manual
Peak current IAA 80 %
Power factor cos φ106 %
Efficiency η99.5 %
Rated motor voltage: 230/400 V - 3 ph - 50 Hz
System voltage: 276/480 V - 3 ph - 60 Hz - 2 & 4 poles (motor voltage + 20 %)
System voltage: 265/460 V - 3 ph - 60 Hz - 6, 8 & 12 poles (motor voltage + 15 %)
If a 50-Hz motor with a 20 % higher voltage is operated on a 60-Hz supply system, frequency
and speed increase by 20 %. But except for minor deviations, the rated motor parameters
remain constant (V/f constant).
If the supply voltage is increased by 15 % compared to the motor voltage, the actual motor
output decreases to 92 % of the original motor output.
In this operating mode, the drum motor should have an output reserve of at least 20 %.
Supply voltage = 1.2 x rated motor voltage (for 2 and 4 number of poles)
Power P kW 100 %
Rated speed nn1/min 120 %
Rated torque MnNm 100 %
Starting torque MANm 100 %
Pull-up torque MSNm 100 %
Pull-out torque MKNm 100 %
Rated current INA 102 %
Peak current IAA 100 %
Power factor cos φ100 %
Efficiency η98 %
Effect of using a motor
with 50-Hz rated motor
voltage on a 60-Hz supply
system with 15/20 %
higher voltage

Interroll Drum motor series i, S, S/A, D
Version 4.1 (06/2015) en-US
Translation of original instruction manual
17
i-series product information
Type plate of i-series drum motor
The information on the type plate of the drum motor is intended for its identification. This is the
only way for the drum motor to be used properly.
For drum motors of the i-series, there are different types of type plates:
• Half-circle type plate on the end housing of the drum motor (glued or lasered)
• Rectangular type plate on the terminal box (if available)
• Rectangular type plates with rounded corners on the individual components with special
information about the product features
IEC 60034
vN: 0,5 (0,6) m/s
SL: 500 mm
Weight: 12,35 kg
Ins. Class: F; IP66
Oil: Iso VG 150 FDA 1,25 l
Cust.Ref.: 01234567890123456789012345
138i
Order N
°
: 0001172181 Pos: 000020
CD: 34
PN: 225 W
~ 3 Phases
np: 4 / 2
UN: ∆230 V/ Y400 V
(UN: ∆276 V/ Y480 V)
fN: 50 Hz
(fN: 60 Hz)
IN: 1,00 A / 0,62 A
(IN: 1,08 A / 0,62 A)
nN: 1.355 (1.626) rpm
cos φ: 0,76
CR: 10 μF
PN: 225 W
~ 3 Phases
np: 4 / 2
PN: 225 W
~ 3 Phases
np: 4 / 2
UN: ∆230 V/ Y400 V; fN: 50 Hz
(UN: ∆276 V/ Y480 V; fN: 60 Hz)
IN: 1,00 A / 0,62 A
(IN: 1,08 A / 0,62 A)
nN: 1.355 (1.626) rpm
cos φ: 0,76
CR: 10 μF
UN: ∆230 V/ Y400 V; fN: 50 Hz
(UN: ∆276 V/ Y480 V; fN: 60 Hz)
IN: 1,00 A / 0,62 A
(IN: 1,08 A / 0,62 A)
nN: 1.355 (1.626) rpm
cos φ: 0,76
CR: 10 μF
Ø: 138 mm
UL-Type: Q6113
UL-Type: Q6113
IEC 60034
CD: 34
CD: 33
vN: 0,5 (0,6) m/s
vN: 0,5 (0,6) m/s
SL: 500 mm
Weight: 12,35 kg
Ins. Class: F; IP66
Oil: Iso VG 150 FDA 1,25 l
Ø: 138 mm
138i
Interroll Trommelmotoren GmbH - 41836 Hückelhoven
Made in Germany | www.interroll.com
Amb. Temp.: -20°C to +40°C
Prod. Week/Year: 41/14/DE
Ser. N°: 12345678
Order N°: 0001172181 Pos: 000020
Cust. Ref.: 01234567890123456789012345
Interroll Trommelmotoren GmbH - 41836 Hückelhoven
Made in Germany
Ser. N
°
: 12345678
Brake: EM 207 VDC 41/14/DE
Encoder: SKF 24 VDC 48 inc
Brake: EM 207 VDC
Brake: EM 207 VDC
Encoder: SKF 24 VDC 48 inc
IEC 60034
SL: 500 mm
Weight: 12,35 kg
Ins. Class: F; IP66
Oil: Iso VG 150 FDA 1,25 l
Ø: 138 mm
138i
Interroll Trommelmotoren GmbH - 41836 Hückelhoven
Made in Germany | www.interroll.com
97863352204360970
Amb. Temp.: -20°C to +40°C
Prod. Week/Year: 41/14/DE
Ser. N°: 12345678
Order N°: 0001172181 Pos: 000020
Cust. Ref.: 012345678901234567890123
Encoder: SKF 24 VDC 48 inc
15
9
8
7
6
5
4
3
21 15 17 18 19 2016
10
11
12 13 14
32
30
28
17
21
22
23
24
25
26
27
28
29
31
30
34
5
2
21
22
23
24
26
21 22
23
24
26
27
25
33
27
25
33
14 131 23429311617 20 19101112
6
345323028 8
15
18
98
10
18
31
16
29
7
11
6
12
13 14
Type plate for the i-series
1 Direction of travel 18 Type
2 Connection diagram number 19 CE mark
3 Number of phases 20 UL mark
4 Rated power 21 Standard for drum motors
5 Number of poles 22 Max. diameter of tube
6 Rated voltage 23 Roller or tube length

Interroll Drum motor series i, S, S/A, D
i-series product information
18
Version 4.1 (06/2015) en-US
Translation of original instruction manual
7 Rated frequency 24 Weight
8 (rated voltage) 1) 25 Insulation class and IP rating
9 (rated frequency) 1) 26 Circumferential speed of tube
10 Rated current 27 Oil type
11 (rated current) 1) 28 Serial number
12 Rated speed of rotor 1) 29 Brake data
13 Power factor 30 Date of manufacture (week/year/country)
14 Run capacitor 31 Encoder data
15 Manufacturer / manufacturing location 32 Permissible ambient temperature
16 Customer part number 33 Type of UL standard
17 Part number 34 EAN code
1) The value depends on the voltage used. All values in parentheses refer to the rated voltage in
parentheses.

Interroll Drum motor series i, S, S/A, D
i-series product information
Version 4.1 (06/2015) en-US
Translation of original instruction manual
19
Electrical data of i-series
Abbreviations See "List of abbreviations", page 108
PNnPnNfNUNINcosφηJRIS/INMS/
MN
MB/
MN
MP/
MN
MNRMUSH delta USH star Cr
kW min-1 Hz W A kgcm2Nm ΩV DC V DC µF
0.018 8 610 50 230 0.33 0.63 0.22 0.9 1.2 1 1.2 1 0.28 575 60 - 5
0.018 8 732 60 230 0.34 0.63 0.21 0.9 1.2 1.2 1.5 1 0.23 287.5 92 - 12
0.018 8 610 50 400 0.19 0.63 0.22 0.9 1.2 1 1.2 1 0.28 575 - 103 5
0.018 8 732 60 460 0.17 0.63 0.21 0.9 1.2 1.2 1.5 1 0.23 575 - 92 3
0.033 4 1384 50 230 0.3 0.62 0.45 0.4 1.7 2.73 2.74 2.48 0.23 286.5 27 - 4
0.033 4 1384 50 230 0.3 0.62 0.45 0.4 1.7 2.73 2.74 2.48 0.23 286.5 27 - 4
0.033 4 1384 50 400 0.17 0.62 0.45 0.4 1.7 2.73 2.74 2.48 0.23 286.5 - 45 4
0.033 4 1384 50 400 0.17 0.62 0.45 0.4 1.7 2.73 2.74 2.48 0.23 286.5 - 45 4
0.04 4 1384 50 230 0.37 0.68 0.41 0.4 1.9 1.8 2 1.8 0.28 240 30 - 5
0.04 4 1610 60 230 0.36 0.68 0.42 0.4 1.9 3.4 3.32 3 0.24 73.5 27 - 12
0.04 4 1384 50 400 0.21 0.68 0.41 0.4 1.9 1.8 2 1.8 0.28 240 - 51 5
0.04 4 1610 60 460 0.18 0.68 0.42 0.4 1.9 3.4 3.32 3 0.24 267.5 - 49 3
0.058 2 2750 50 230 0.26 0.78 0.71 0.4 2.4 2.15 2.26 1.9 0.201 183.5 19 - -
0.058 2 2750 50 400 0.15 0.78 0.71 0.4 2.4 2.15 2.26 1.9 0.201 183.5 - 32 -
0.058 4 1310 50 230 0.39 0.68 0.54 0.6 2.4 2.31 2.31 2.15 0.423 106.4 14 - -
0.058 4 1310 50 400 0.23 0.68 0.54 0.6 2.4 2.31 2.31 2.15 0.423 106.4 - 25 -
0.07 2 2778 50 230 0.38 0.82 0.56 0.4 2.6 1.9 2 1.9 0.24 190 30 - -
0.07 2 3328 60 230 0.4 0.82 0.53 0.4 2.6 2.6 2.74 2.3 0.2 46 23 - -
0.07 2 2778 50 400 0.22 0.82 0.56 0.4 2.6 1.9 2 1.9 0.24 190 - 51 -
0.07 2 3328 60 460 0.2 0.82 0.53 0.4 2.6 2.6 2.74 2.3 0.2 179.5 - 44 -
0.07 4 1288 50 230 0.48 0.68 0.53 0.6 1.4 1.66 1.75 1.66 0.52 156 25 - 7
0.07 4 1546 60 230 0.5 0.68 0.51 0.6 1.4 2.2 3.1 2.3 0.43 44 22 - 17
0.07 4 1288 50 400 0.28 0.68 0.53 0.6 1.4 1.66 1.75 1.66 0.52 156 - 45 7
0.07 4 1546 60 460 0.26 0.68 0.49 0.6 1.4 2.2 3.1 3 0.43 157.5 - 42 4
0.099 2 2727 50 230 0.45 0.78 0.71 0.6 2.4 2.31 2.31 2.15 0.347 106.4 19 - -
0.099 2 2727 50 400 0.26 0.78 0.71 0.6 2.4 2.31 2.31 2.15 0.347 106.4 - 32 -
0.12 2 2778 50 230 0.59 0.78 0.65 0.6 2.6 2 2.1 2 0.41 89 20 - -
0.12 2 3308 60 230 0.6 0.78 0.65 0.6 2.6 2.8 3 2.6 0.35 22.5 16 - -
0.12 2 2778 50 400 0.34 0.78 0.65 0.6 2.6 2 2.1 2 0.41 89 - 35 -
0.12 2 3308 60 460 0.32 0.78 0.61 0.6 2.6 2.8 3 2.6 0.35 89 - 33 -
80i 3-phase

Interroll Drum motor series i, S, S/A, D
i-series product information
20
Version 4.1 (06/2015) en-US
Translation of original instruction manual
PNnPnNfNUNINcosφηJRIS/INMS/
MN
MB/
MN
MP/
MN
MNRMUSH delta USH star Cr
kW min-1 Hz W A kgcm2Nm ΩV DC V DC µF
0.035 12 353 50 230 0.71 0.6 0.21 3.3 2.4 1.1 1.46 1.1 0.95 208 44 - 10
0.035 12 353 50 400 0.41 0.6 0.21 3.3 2.4 1.1 1.46 1.1 0.95 208 - 77 10
0.058 12 353 50 230 0.91 0.6 0.26 5.7 1.9 1.07 1.16 0.91 1.569 144 39 - -
0.058 12 353 50 400 0.53 0.6 0.26 5.7 1.9 1.07 1.16 0.91 1.569 144 - 69 -
0.066 8 680 50 230 0.55 0.6 0.5 3.3 2 1.57 1.82 1.74 0.927 190 31 - -
0.066 8 680 50 400 0.32 0.6 0.5 3.3 2 1.57 1.82 1.74 0.927 190 - 55 -
0.07 12 353 50 230 1.07 0.6 0.27 5.7 2 1 1.3 1 1.89 128 41 - 15
0.07 12 415 60 230 1.08 0.6 0.21 5.7 1.92 1.2 1.29 1.1 1.4 128 62 - 11
0.07 12 353 50 400 0.62 0.6 0.27 5.7 2 1 1.3 1 1.89 128 - 71 15
0.07 12 415 60 460 0.62 0.6 0.21 5.7 1.92 1.2 1.29 1.1 1.4 128 - 143 11
0.08 8 680 50 230 0.69 0.6 0.48 3.3 2.2 1.4 1.6 1.4 1.12 164 34 - 10
0.08 8 680 50 400 0.4 0.6 0.48 3.3 2.2 1.4 1.6 1.4 1.12 164 - 59 10
0.083 6 865 50 230 0.66 0.63 0.5 3.3 1.9 1.82 1.74 1.49 0.916 126.4 26 - -
0.083 6 865 50 400 0.38 0.63 0.5 3.3 1.9 1.82 1.74 1.49 0.916 126.4 - 45 -
0.1 6 865 50 230 0.8 0.66 0.47 3.3 2.1 1.8 2 1.8 1.1 111.4 29 - 11
0.1 6 865 50 400 0.46 0.66 0.47 3.3 2.1 1.8 2 1.8 1.1 111.4 - 51 11
0.1 6 1096 60 575 0.37 0.63 0.43 3.3 2.1 2.17 2.13 1.8 0.87 170 - 59 5
0.124 8 678 50 230 0.97 0.62 0.52 5.7 2 2.32 2.18 2.05 1.747 97 29 - -
0.124 8 678 50 400 0.56 0.62 0.52 5.7 2 2.32 2.18 2.05 1.747 97 - 51 -
0.124 4 1360 50 230 0.65 0.7 0.67 2.1 2.9 1.57 1.57 1.32 0.871 86 20 - -
0.124 4 1360 50 400 0.38 0.7 0.67 2.1 2.9 1.57 1.57 1.32 0.871 86 - 34 -
0.149 6 915 50 230 1.02 0.62 0.59 5.7 2.2 2.81 2.64 2.48 1.555 54.8 17 - -
0.149 6 915 50 400 0.59 0.62 0.59 5.7 2.2 2.81 2.64 2.48 1.555 54.8 - 30 -
0.15 8 678 50 230 1.18 0.62 0.51 5.7 2.2 1.35 1.5 1.35 2.11 89 33 - 16
0.15 8 678 50 400 0.68 0.62 0.51 5.7 2.2 1.35 1.5 1.35 2.11 89 - 56 16
0.15 4 1350 50 230 0.94 0.71 0.56 2.1 3.2 1.85 2.15 1.85 1.06 71 24 - 13
0.15 4 1632 60 575 0.38 0.7 0.57 2.1 3.2 1.9 1.9 1.6 0.88 114 - 45 5
0.15 4 1350 50 400 0.54 0.71 0.56 2.1 3.2 1.85 2.15 1.85 1.06 71 - 41 13
0.18 6 915 50 230 1.39 0.62 0.52 5.7 2.4 2.8 3 2.8 1.88 42.8 18 - 19
0.18 6 1098 60 230 1.36 0.76 0.44 5.7 3.2 3.4 3.2 3 1.57 43.5 34 - 12
0.18 6 915 50 400 0.8 0.62 0.52 5.7 2.4 2.8 3 2.8 1.88 42.8 - 32 19
0.18 6 1098 60 230 1.5 0.68 0.44 5.7 2.4 3.4 3.2 3 1.57 11.08 17 - 52
0.18 6 1098 60 460 0.75 0.68 0.44 5.7 3.2 3.4 3.2 3 1.57 43.5 - 33 13
113i 3-phase
This manual suits for next models
13
Table of contents
Other Interroll Engine manuals