Lenze IE2 Guide

Three-phase AC motors
IE2 three-phase AC motor m550-H Version B
IE3 three-phase AC motor m550-P Version B
Mounng and switch-on instrucons EN


Contents
About this document 5
Document descripon 5
Further documents 5
Notaons and convenons 6
Safety instrucons 7
Basic safety instrucons 7
Applicaon as directed 7
Residual hazards 8
Product informaon 9
Idencaon of the products 9
Nameplates 9
Product codes 10
Features 12
Transport 13
Storage 14
Mechanical installaon 15
Important notes 15
Preparaon 15
Installaon 15
Dimensions 15
Mounng 16
Product extensions 17
Electrical installaon 19
Important notes 19
Preparaon 19
Motor connecon 20
Connecon via terminal box 21
Connecon via ICN connector 26
Connecon via M12 connector 29
Connecon via HAN connector 30
Commissioning 32
Important notes 32
Before inial switch-on 33
Funconal test 33
Maintenance 34
Maintenance intervals 35
Maintenance work 36
Repair 39
Diagnoscs and fault eliminaon 40
Malfuncons 40
Contents
3

About this document
WARNING!
Read this documentaon carefully before starng any work.
▶Please observe the safety instrucons!
Document descripon
This document is intended for skilled personnel who work with the products described.
The data and informaon compiled in this document serve to support you in the electrical and
mechanical installaon and commissioning.
•The document is only valid together with the complete documentaon of the product!
•For safety-rated aachments observe the enclosed operang instrucons of the
manufacturer!
•The document includes safety instrucons which must be observed.
•All persons working on and with the drives must have the documentaon at hand during
work and observe the informaon and notes relevant for it.
•The documentaon must always be complete and in a perfectly readable state.
Further documents
Informaon and tools with regard to the Lenze products can be found on the
Internet:
www.Lenze.com à Downloads
About this document
Document descripon
5

Notaons and convenons
Convenons are used in this document to disnguish between dierent types of informaon.
Numeric notaon
Decimal separator Point Generally shown as a decimal point.
Example: 1 234.56
Warnings
UL Warnings UL Are used in English and French.
UR warnings UR
Text
Engineering Tools " " Soware
Example: "Engineer", "EASY Starter"
Icons
Page reference ¶Reference to another page with addional informaon.
Example: ¶ 16 = see page 16
Documentaon reference ,Reference to other documentaon with addional informaon.
Example: , EDKxxx = see documentaon EDKxxx
Layout of the safety instrucons
DANGER!
Indicates an extremely hazardous situaon. Failure to comply with this instrucon will result
in severe irreparable injury and even death.
WARNING!
Indicates an extremely hazardous situaon. Failure to comply with this instrucon may result
in severe irreparable injury and even death.
CAUTION!
Indicates a hazardous situaon. Failure to comply with this instrucon may result in slight to
medium injury.
NOTICE
Indicates a material hazard. Failure to comply with this instrucon may result in material
damage.
About this document
Notaons and convenons
6

Safety instrucons
Basic safety instrucons
Disregarding the following basic safety instrucons and safety informaon may lead to severe
personal injury and damage to property!
•Only use the product as directed.
•Never commission the product in the event of visible damage.
•Never modify the product technically.
•Never commission the product before assembly has been completed.
•Never operate the product without the required covers.
•Connect/disconnect all pluggable connecons only in deenergized condion!
•Only remove the product from the installaon in the deenergized state.
•The product can – depending on their degree of protecon – have live, movable or
rotang parts during or aer operaon. Surfaces can be hot.
•Observe all specicaons of the corresponding documentaon supplied. This is the
condion for safe and trouble-free operaon and the achievement of the specied
product features.
•The procedural notes and circuit details given in the associated documentaon are
suggesons and their transferability to the respecve applicaon has to be checked. The
manufacturer of the product does not take responsibility for the suitability of the process
and circuit proposals.
•All work with and on the product may only be carried out by qualied personnel.
IEC 60364 and CENELEC HD 384 dene the qualicaons of these persons:
-They are familiar with installing, mounng, commissioning, and operang the product.
-They have the corresponding qualicaons for their work.
-They know and can apply all regulaons for the prevenon of accidents, direcves, and
laws applicable at the place of use.
Applicaon as directed
•The product is a professional equipment intended for use by trades, specic professions or
industry and not for sale to the general public. IEC 60050 [IEV 161-05-05]
•To prevent personal injury and damage to property, higher-level safety and protecon
systems must be used!
•All transport locks must be removed.
•Mounted eye bolts on the motor are not suitable for transporng geared motors.
•The product may only be operated under the specied operang condions and in the
specied mounng posions.
•The product may be operated on the mains or on the inverter.
•Only cered applicaon brakes may be used as safety brakes for funconal safety.
•The product must not be operated in private areas, in potenally explosive atmospheres
and in areas with harmful gases, oils, acids and radiaon.
Safety instrucons
Basic safety instrucons
7

Residual hazards
Even if notes given are taken into consideraon and protecve measures are implemented,
the occurrence of residual risks cannot be fully prevented.
The user must take the residual hazards menoned into consideraon in the risk assessment
for his/her machine/system.
If the above is disregarded, this can lead to severe injuries to persons and damage to
property!
Product
Observe the warning labels on the product!
Dangerous electrical voltage:
Before working on the product, make sure there is no voltage applied to the power terminals!
Aer mains disconnecon, the power terminals will sll carry the hazardous electrical voltage for the me given next to the
symbol!
High leakage current:
Carry out xed installaon and PE connecon in compliance with:
EN IEC 61800−5−1 / EN IEC 60204−1
Hot surface:
Use personal protecve equipment or wait unl the device has cooled down!
Protecon of persons
•The power terminals may carry voltage in the switched-o state or when the motor is
stopped.
-Before working, check whether all power terminals are deenergized.
•Voltages may occur on the drive components (e.g. capacive, caused by inverter supply).
-Careful earthing in the marked posions of the components must be carried out.
•There is a risk of burns from hot surfaces.
-Provide protecon against accidental contact.
-Use personal protecve equipment or wait unl the device has cooled down.
-Prevent contact with ammable substances.
•There is a risk of injury due to rotang parts.
-Before working on the drive system, ensure that the motor is at a standsll.
•There is a risk of accidental start-up or electric shock.
Motor protecon
•Installed temperature sensors are no full protecon for the machine.
-If necessary, limit the maximum current. Parameterize the inverter so that it will be
switched o aer some seconds of operaon with I > Irated , especially if there is a risk
of blocking.
-Integrated overload protecon does not prevent overloading under all condions.
•The fuses are no motor protecon.
-Use a current-dependent motor protecon switch.
-Use the built-in temperature sensors.
•Too high torques cause a fracon of the motor sha.
-Do not exceed the maximum torques according to the technical data on the
nameplate.
•Lateral forces on the motor sha are possible.
-Align the shas of motor and driven machine exactly to each other.
Safety instrucons
Residual hazards
8

Product informaon
Idencaon of the products
Nameplates
11.1 11.2 11.3 11.511.4 11.6 11.7 11.8 11.9 12 13.1 13.2 13.3
4
1
L
23
22
20
19
23
Hz kW r/min C86 M2 n2 c
89
7.1 7.3
7.8
Brake
ACH
Fan
15
5
16.416.216.1
6.4 6.5 6.6 6.7
6.3
7.57.4
6.2
7.2
6.1 14
16.3
17.1 17.2 17.3
18
7.6 7.7SF
10
A
V
A
V
2
3
21
Posion Contents Posion Contents
1 Manufacturer 12 Motor code for Lenze frequency inverter
2 Country of producon 13 Gearbox output data
3 Approvals 13.1 Output torque
4 Standards 13.2 Output speed
5 Motor type 13.3 Load capacity
6 Gearbox data 14 Temperature monitoring
6.1 Product name 15 Feedback
6.2 Product code 16 Brake
6.3 Gearbox rao 16.1 Size
6.4 Posion: Sha, ange, terminal box/motec 16.2 Supply voltage
6.5 Mounng posion 16.3 Power
6.6 Lubricant 16.4 Braking torque
6.7 Lubricant quanty 17 Blower
7 Motor data 17.1 Rated voltage
7.1 Product name 17.2 Rated frequency
7.2 Product key 17.3 Rated power
7.3 Degree of protecon 18 An-condensaon heater
7.4 Eciency class 19 Customer data
7.5 Operang mode 20 Year of manufacture / week of manufacture
7.6 Rated frequency 21 Country of producon, code
7.7 Service factor 22 Material number
7.8 Class of insulaon 23 Serial number
8 Ambient temperature 24 Bar code
9 Weight
10 UL product category
11 Motor data at rated frequency
11.1 Rated frequency
11.2 Rated power
11.3 Rated voltage
11.4 Rated current
11.5 Rated voltage
11.6 Rated current
11.7 Rated speed
11.8 Power factor
11.9 Eciency
Product informaon
Idencaon of the products
Nameplates
9

Product codes
Motor product code
Example M 55 B H 063 S 04 5 E 0 0 C C
Product type Motor M
Product family 55
Version B
Eciency class IE2 H
IE3 P
Size 063
071
080
090
100
112
132
160
180
Overall length Short S
Medium M
Long L
Number of poles 4-pole 04
Degree of protecon IP54/IP55 5
IP65/IP66 6
Cooling Self-venlaon E
Forced venlaon F
Brake Without 0
Spring-applied brakes F
Feedback Without 0
Absolute value encoder A
Incremental encoder E
Resolver R
Approvals None N
CE C
CE, CCC 3
CE, cULus L
CE, cULus, CCC 5
CE, cURus U
CE, cURus, CCC W
Design type Internal key C
Product informaon
Idencaon of the products
Product codes
10

Product code feedbacks
Example AS 1024 - 8 V - K 2
Meaning Variant Product code
Product family Resolver RS
Resolver for safety funcon RV
Incremental encoder IG
Incremental encoder with commutaon
signal
IK
Absolute value encoder, singleturn AS
Absolute value encoder, multurn AM
Number 2-pole Resolver for servo motors 0
2-pole Resolver for three-phase AC
motors
1
Number of pole pairs for resolvers 2
3
4
...
Number of bits, steps or increments per
revoluon
20
32
128
512
1024
2048
...
Supply voltage 5 V
8 V
15 V
24 V
...
Interface or signal level Standard
TTL T
HTL (for incremental encoders) H
Hiperface (for absolute value encoders) H
EnDat E
SinCos 1 Vss S
Digital D
For safety funcon
TTL U
HTL (for incremental encoders) K
Hiperface (for absolute value encoders) K
EnDat F
SinCos 1 Vss V
Digital D
Safety Integrity Level (SIL) 1
2
3
4
Product informaon
Idencaon of the products
Product codes
11

Features
The following gure provides an overview of the elements and connecons on the product.
Their posion, size and appearance may vary.
Foot
Output flange
Output shaft
Brake
Motor connection
Cooling
Feedback
Temperature monitoring
Product informaon
Features
12

Transport
•Ensure appropriate handling.
•Make sure that all component parts are securely mounted. Secure or remove loose
component parts.
•Only use safely xed transport aids (e.g., eye bolts or support plates).
•Do not damage any components during transport.
•Avoid electrostac discharges on electronic components and contacts.
•Avoid impacts.
•Check the carrying capacity of the hoists and load handling devices. The weights can be
found in the shipping documents.
•Secure the load against pping and falling down.
•Standing beneath suspended loads is prohibited.
The transport weights can be found in the shipping documents!
Transport
13

Mechanical installaon
Important notes
•Install the product according to the informaon in the chapter "Standards and operang
condions".
4Standards and operang condions ^ 42
•The technical data and the data regarding the supply condions can be found on the
nameplate and in this documentaon.
•Ambient media − especially chemically aggressive ones − may damage sha sealing rings,
lacquers and plascs.
•Lenze oers special surface and corrosion protecon in this case.
Preparaon
•Protect sha sealing rings from contact with solvents.
•Remove protecon covers from shas.
•Thoroughly remove ancorrosion agents from the sha and from ange faces.
•Draw the transmission elements onto the output sha only by using the centering thread.
•Align the output sha and transmission elements exactly to avoid tensions.
•Mount belt pulleys, sprockets, or gear wheels as close as possible to the sha shoulder in
order to keep the bending load of the sha and the bearing forces at a minimum level.
•Tighten all screw connecons with the specied torques and secure them with standard
screw locking adhesive.
•Check paint for damage and repair professionally.
Installaon
•The mounng surfaces must be plane, torsionally rigid and free from vibraons.
•The mounng areas must be suited to absorb the forces and torques generated during
operaon.
•Ensure an unhindered venlaon.
•For versions with a fan, keep a minimum distance of 10 % from the outside diameter of the
fan cover in intake direcon.
Dimensions
Dimensions are contained in the conguraon document.
Mechanical installaon
Important notes
15

Mounng
Transmission elements
•Fit or remove transmission elements only using suitable equipment.
•For ng the transmission elements use the center hole in the sha.
•Avoid impacts and shocks.
•In case of a belt drive, tension the belt in a controlled manner according to manufacturer
informaon.
•Be sure to carry out mounng in a manner free from distoron.
•Compensate minor inaccuracies by suitable exible couplings.
Fastening
•Use screws with a minimum property class of 8.8.
•Observe prescribed ghtening torques.
•Secure against unintended loosening.
•For alternang loads, we recommend applying anaerobic curing adhesive between ange
and mounng surface.
Thread M3 M4 M5 M6 M8 M10 M12 M16 M20 M24 M27 M30
Strength Tightening torque Nm ±10 %
8.8 Nm 1.3 3.0 5.9 10.1 24.6 48 84 206 415 714 1050 1428
10.9 Nm 1.9 4.6 8.6 14.9 36.1 71 123 302 592 1017 1496 2033
Mechanical installaon
Mounng
16

Product extensions
Assembly of lockable manual release lever in operang posion
1
2
3
4
5
1 Cheese head screw with hexagon nut 4 Manual release lever
2 Manual release shackle 5 Fan cover
3 Terminal block
How to mount the manual release lever
1.Screw the cheese head screw with hexagon nut (1) loosely into the terminal block (3).
2.Push the terminal block (3) over the manual release lever (4).
3.Guide the manual release lever with terminal block (3+4) through the slot in the fan cover
(5) and screw it into the threaded hole in the manual release shackle (2).
4.Tighten the manual release lever (4) to the prescribed torque.
5.Align the terminal block (3) (see g.) and insert it from above into the slot of the fan cover
(5) up to the stop.
6.Tighten the cheese head screw (1) to the specied torque and counter with hexagon head
screw.
Mechanical installaon
Mounng
Product extensions
17

Handling of lockable manual release lever
NOTICE
▶Only lock the hand release in the service posion for service work!
▶The manual release must not be locked in the service posion during operaon, otherwise
the brake could be damaged!
▶Always secure the terminal block against loosening in every posion with cheese head
screw and nut!
Operang posion, brake is not released Service posion, brake is released
1 4 351.1
1 Cheese head screw with hexagon nut 4 Manual release lever
3 Terminal block 5 Fan cover
How to lock the manual release lever:
1.Loosen hexagon nut (1.1) and cheese head screw (1).
2.Pull the terminal block (3) out of the slot in the fan cover and turn it by 180 .
3.Actuate the manual release lever (4) and bring it into the service posion, pushing the
terminal block (3) under slight pressure into the slot of the fan cover (5).
4.Tighten the cheese head screw (1) to the specied torque and counter with hexagon nut
(1.1).
Mechanical installaon
Mounng
Product extensions
18

Electrical installaon
Important notes
DANGER!
Risk of injury and risk of burns from dangerous voltage
Power terminals may also carry voltage in the switched-o state or when the motor is stopped
and may cause life-threatening cardiac arrhythmia and serious burns.
▶Disconnect the product from the mains.
▶Check that the power terminals are deenergized before starng work.
•When working on energized products, comply with the applicable naonal accident
prevenon regulaons.
•The electrical installaon must be carried out according to the appropriate regulaons
(e.g. cable cross-secons, fuses, PE connecon).
•The manufacturer of the system or machine is responsible for adherence to the limits
required in connecon with EMC legislaon.
Connecon for high leakage current
If the leakage current is greater than 3.5 mA for alternang current or greater than 10 mA for
direct current, the standard EN IEC 61800−5−1 requires that at least one or more of the
following measures be met:
•The minimum PE conductor cross-secon is 10 mm2 with Cu or 16 mm2 with Al.
•Aachment of an addional protecve grounding conductor with the same cross-secon
as the original protecve grounding conductor.
-Do not place the addional terminal on the same terminal.
•Provide automac disconnecon of the mains in case of interrupon of the protecve
conductor.
Operaon on an external inverter
A max. pulse voltage amplitude of Upk = 1560 V at the motor terminals must not be exceeded.
Here, the minimum pulse rise me must be tR = 0.1 µs.
If it cannot be ruled out that the permissible voltage peaks will be exceeded or that the
minimum pulse rise me will not be reached, the following measures must be iniated:
•Reducon of the DC-bus voltage (threshold for brake chopper voltage)
•Use of lters, chokes
•Use of special motor cables
Preparaon
EMC-compliant wiring
The EMC-compliant wiring is described in detail in the documentaon of the
Lenze inverters.
Electrical installaon
Important notes
19

Motor connecon
To connect the motor correctly, you must follow:
•The notes in the terminal box of the motor.
•The notes in the conguraon document of the motor.
•The technical data on the motor nameplate.
Second ground connecon on the motor
According to the EN IEC 61800−5−1 standard, addional measures are required for the
protecve earth connecon if the leakage current is greater than 3.5 mA for alternang
current or greater than 10 mA for direct current.
4Important notes ^ 19
A possible measure is the execuon via a second ground connecon.
Scope of delivery when a second ground connecon is selected:
•Toothed lock washer
•Washer
•Fixing screw
An addional grounding cable is not included in the scope of delivery.
The dimensioning of the grounding is done by the customer.
Electrical installaon
Motor connecon
20
This manual suits for next models
1
Table of contents
Other Lenze Engine manuals

Lenze
Lenze g500-S User manual

Lenze
Lenze Smart Motor m300 Guide

Lenze
Lenze G-motion GPA Series User manual

Lenze
Lenze g500-H User manual

Lenze
Lenze MCS 09 Guide

Lenze
Lenze IE2 g500-H Guide

Lenze
Lenze g500-H45 Technical manual

Lenze
Lenze MCA Series Guide

Lenze
Lenze MCS 06C60 Guide

Lenze
Lenze SDS Series User manual