inTest THERMOSTREAM ATS-545 User guide

Part Number:
41 Hampden Road, Mansfield, MA U.S.A.
Tel: +1.781.688.2300
www.inTESTthermal.com LM04050
ATS-545 & -645
THERMOSTREAM®
Interface & Applications Manual
Revision A
January 2013


ATS-545 & -645 Interface & Applications Manual iii
. . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents
Preface
To Our Customers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii-viii
inTEST Thermal Solutions Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii-ix
Before You Call. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii-x
Chapter 1. Safety
Chapter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Section A. Safety Precautions, Warnings, Cautions
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Section B. CONSIGNES DE SÉCURITÉ POUR LE PERSONNEL EXPLOITANT
AVERTISSEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
ATTENTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Section C. SICHERHEITSHINWEISE FÜR DAS BEDIENPERSONAL
WARNHINWEIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
HINWEIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
Section D. PRECAUCIONES DE SEGURIDAD PARA EL PERSONAL DE OPERACIONES
ADVERTENCIA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
PRECAUCION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
Section E. Säkerhets Föreskrifter och Varningar, Varsamhet
Varningar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20
Försiktighet och Varsamhet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23
Chapter 2. Preparation For Use
Chapter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Section A. Initial System Setup Checklist
Setup Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Section B. General Information
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Scope of Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
User/Owner Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Remote Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Section C. Unpacking/Receipt of Shipment
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Receipt of Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Unpacking Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Repackaging System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12

TABLE OF CONTENTS
iv ATS-545 & -645 Interface & Applications Manual
Section D. Placement Requirements
Clearances, Dimensions, Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Section E. Attaching the Thermal Cap and Shroud
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
Section F. Rear Panel, Air and Power Connections
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Section G. Power Connections and Voltage Requirements
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
System Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19
To Re-Configure the Auto Transformer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Voltage Configuration Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
Connecting the Main Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Section H. Air Connections
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26
Compressed Air Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27
Connecting the Main Air Supply (Compressed Air) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28
Connecting Purged Air. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29
Section I. Rear Panel I/O Ports
I/O Ports Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30
Section J. Interfacing and Attaching Thermocouples
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
Sensor Interface Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
T-Type Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
K-Type Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37
Non-Standard Thermocouples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-38
Section K. Static, Moisture, and Extreme Temperature Protection
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-40
Electrostatic Discharge (ESD) Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
-41
Moisture Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-42
Insulation (Minimizing Heat Conductivity) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-44
Section L. MobileTempTM Series ThermoChambers
Chapter 3. System Operation
Chapter Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Section A. System Startup and Shutdown
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Initializing Cold Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Initializing Hot Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
System Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Section B. Thermal Head and Manipulator
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Head and Manipulator Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Manipulator Locks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Stand Motion: Up/Down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Thermal Head Motion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Section C. Operator Control Module (OCM)

. . . . .
TABLE OF CONTENTS
ATS-545 & -645 Interface & Applications Manual v
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
OCM Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
ATS-545 & -645 Screens Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Air Purge and Compressor Delay Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
TOP MENU Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
CONFIGURE SYSTEM Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
MANUAL OPERATION Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
MANUAL TEST SETUP Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
MANUAL OPERATION “RAMP/CYCLE” Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
DEFINE PARAMETERS Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
PROGRAM OPERATION Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
PROGRAM TEST SETUP Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
PROGRAM OPERATION “RAMP/CYCLE” Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32
SETUP OPTIONS Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
COPY SETUP Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-35
Chapter 4. Remote Interfaces
Chapter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Section A. Remote Interfaces, Overview and Assumptions
Remote Interfaces Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Section B. Syntax
Syntax Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Section C. Command Processing
Command Processing Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Section D. Error Reporting
Section E. Maximizing Communications Throughput
Section F. IEEE-488.2 Interface
Set: Bus Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Section G. Serial Interface
Serial Interface Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Serial Interface Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Serial Cables: 25 Pin, 9 Pin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Section H. Remote Command Set
Remote Commands Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
IEEE Mandatory Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
RS-232C Serial Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
Device Specific Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
Section I. MCT Interface
MCT Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
Chapter 5. Routine Maintenance
Chapter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Section A. Maintenance Log

TABLE OF CONTENTS
vi ATS-545 & -645 Interface & Applications Manual
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Section B. Inspection and Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
Section C. Side Panel and Cover Removal
Section D. Air Path Maintenance
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
Drain Moisture from Pneumatics Filter Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Pneumatics Filter Element Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
Air Dryer: Post Filter Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
Muffler Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
Section E. Verification of DUT
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
DUT Verification Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
Low Temperature Verification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
High Temperature Verification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
Section F. Calibration
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21
Calibration Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22
Calibration Choice Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23
Calibration Procedure (Main Air Sensor). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
-24
Calibration Procedure (Type T or K Sensor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
Flow Board Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
LCD Screen Contrast Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-37
Appendices.
Appendix A - MSDS Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Appendix B - Drawings Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Appendix C - Backwards Compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1

ATS-545 & -645 Interface & Applications Manual vii
. . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface
©Copyright 2013 by Temptronic Corporation
All Rights Reserved
The text of this publication, or any part thereof, may not be reproduced or transmitted in any
form or by any means, electronic or mechanical, including photocopying, recording, or
otherwise, without the prior written permission of Temptronic Corporation.
The software program contained within the THERMOSTREAM®System is protected by
copyright laws that pertain to computer software. Use of this software does not authorize de-
compiling, disassembling, or reverse engineering to gain access to the program code.
Temptronic Corporation does not authorize any copy, change, or other use of this software.
Notice
Patents have been granted and/or patent applications are pending or are in process of
preparation on all our developments.
The material in this manual is for informational purposes and is subject to change without
notice.
Temptronic Corporation assumes no responsibility for any errors which may appear in this
manual.

PREFACE
To Our Customers
viii ATS-545 & -645 Interface & Applications Manual
To Our Customers
This Manual The purpose of this manual is to help obtain the greatest return on your investment. Temptronic
suggests that operators, supervisors, and technicians responsible for operating and maintaining
this equipment become familiar with the contents of these manuals prior to using the
equipment.
This manual instructs how to setup, operate and perform routine maintenance for the ATS-545
& -645 THERMOSTREAM®Systems.
Other Manuals
in the Set Following is the complete list of manuals which make up this information set
In this Section The following is covered in this preface
Manual Name Part Number
ATS-545 & -645 Interface and Applications Manual LM04050
ATS-545 & -645 Service Manual LM04060
Topic See Page
inTEST Thermal Solutions Support ix
Before You Call x

. . . . .
PREFACE
inTEST Thermal Solutions Support
ATS-545 & -645 Interface & Applications Manual ix
inTEST Thermal Solutions Support
Introduction inTEST Thermal Solutions is committed to assisting end users and technicians to maintain
operational systems which are highly reliable. inTEST Thermal Solutions offers the following
support services.
Customer Training Formal technical training courses are available. The training courses cover the theory of
operation and the maintenance procedures for the System. For further information, contact the
inTEST Thermal Solutions Service Department.
Repair Service Temptronic maintains a fully equipped repair center at the factory plant for warranty and non-
warranty repairs. For further information on module and circuit board repairs, our exchange
program, and the availability of spare parts, contact the inTEST Thermal Solutions Service
Department.
Before returning any module or circuit board for repair, contact the inTEST Thermal Solutions
Service Department to obtain a return authorization (RA) number.
Spare Parts Electrical and mechanical replaceable parts for the System can be obtained through your local
inTEST Thermal Solutions representative, or directly from the inTEST Thermal Solutions
Service Department. When ordering, be sure to specify the:
• Quantity
• Temptronic part number
• Description
• Reference designation (if any)
• Complete model number and serial number of your system
For your convenience, Spare Parts Kits are available for different levels of service activity.
Technical Support Contact the inTEST Thermal Solutions Service Department by one of the following means:
ATTENTION
1. Please note that the 1.800 toll free telephone number is dedicated to Service Department
calls only. It is not possible to dial this number and to transfer to other departments within
inTEST Thermal Solutions.
2. The main telephone number, 781.688.2300, should be used for non-service related calls.
inTEST Thermal Solutions Technical Support
1.800.558.5080 Toll Free Telephone (service calls only)
service@inTESTthermal.com e-Mail Address
781.688.2302 Service FAX line
781.688.2300 Main Telephone line

PREFACE
Before You Call
x ATS-545 & -645 Interface & Applications Manual
Before You Call
Introduction You can help us support your machine in a timely fashion by having on hand specific
information when calling in:
• Software Version
• System Model Number
System Model
Number A modular system design allows the customer to select options or features as desired for a
given installation or application
The System Model Number Designation, printed on the System nameplate, reflects the
configuration at time of shipment:

ATS -545 & -645 Interface & Applications Manual 1-1
1
. . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety
Chapter Overview
Introduction This chapter covers all the safety Warnings and Cautions for the ATS-545 & -645
THERMOSTREAM®Systems.
In this Chapter This chapter is divided into the following Sections:
Topic See Page
Safety Precautions, Warnings, Cautions 2
CONSIGNES DE SÉCURITÉ POUR LE PERSONNEL EXPLOITANT 7
SICHERHEITSHINWEISE FÜR DAS BEDIENPERSONAL 12
PRECAUCIONES DE SEGURIDAD PARA EL PERSONAL DE
OPERACIONES 16
Säkerhets Föreskrifter och Varningar, Varsamhet 20

1SAFETY
Warnings
1-2 ATS -545 & -645 Interface & Applications Manual
Section A:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Precautions, Warnings, Cautions
Warnings
WARNING
WARNING: Refer to Accompanying Documentation
Electrical Hazard
WARNING: High Voltage, Electrical Shock Hazard
Hot Surface
WARNING: Hot Surface
Cold Surface
WARNING: Cold Surface
WARNING 1: The locations of potentially dangerous voltages and other hazards such as hot
surfaces or cold surfaces or compressed air/gases/vapors at high pressures are identified and
labeled on the equipment. Be careful to observe these warnings when installing, operating,
maintaining, or servicing the equipment. Observe all warnings given in this manual. Only use
the equipment for the intended usages specified by the manufacturer.
WARNING 2: The troubleshooting instructions contained in this manual can involve a
possible contact with electrical power at high voltages, compressed air at high pressures, and
refrigerants at high or vacuum pressures. These hazards can be injurious or dangerous to life.
Do not perform these instructions unless you qualify to do them.
WARNING 3: To avoid shock hazard, the equipment must be grounded with an adequate
earth ground per local electrical codes.
WARNING 4: When connecting thermocouple sensors to the Device Under Test (DUT),
electrically isolate the sensors to protect operators from contact with any hazardous voltages
which could be present at the DUT site.
WARNING 5: Parts inside the thermal head operate at extremely hot and cold temperatures
and are dangerous to touch. Do not perform any maintenance inside the thermal head until the
system is turned off. Wait until the head parts have reached a safe and stable temperature near
ambient.
WARNING 6: Keep your fingers out of the space between the thermal cap on the head and the
DUT site during the up/down motion of the System’s thermal head.

. . . . .
SAFETY
Warnings
ATS-545 & -645 Interface & Applications Manual 1-3
WARNING 7: Per SEMI S2-93A, energized electrical work (“Hot Work”) is specified by
Type as follows:
WARNING 8: Where equipment must be fully de-energized (electrically “cold”) to allow safe
entry into system, the following Lockout/Tagout procedure is required per OSHA 29 CFR
1910: a) For devices with a power cord which “unplugs” from a service receptacle, the end
user must supply and tag a Plug lockout shell which completely encloses the plug and prevents
accidental reconnection; b) for devices hardwired to the electrical supply, the end user must
install and tag a power disconnect switch with a lock out position, or install and tag a circuit
breaker with a lock out position, to prevent accidental reconnection.
WARNING 9: To de-energize the System for safe replacement of a module, turn off the ac
power (cease operations and power down), then turn off the System’s air pressure supply, then
bleed all air from System by turning on ac power just long enough to exhaust all air from
System. Now disconnect both the main power supply cord and disconnect the air supply line
from air supply port fitting on the rear frame module. The only stored energy remaining in the
System will then be that within some electrical capacitors. One large capacitor is near the
System’s air-chiller compressor. Other large capacitors are in the System’s electrical power
supplies.
WARNING 10: If service of the Air Chiller Module is required, only a licensed (and/or EPA
Certified) refrigeration service person, authorized by the Temptronic Corporation, is qualified
to perform any charging or handling of the refrigerants in the System.
WARNING 11: Under no circumstances (leak testing or any other purpose) is the Air Chiller
Module to be charged with any gas at a pressure above 150 psig (10.34 bar).
WARNING 12: The Air Chiller Module acts as a counterbalance for the Thermal Head
Assembly. Before removing the Air Chiller Module, make sure the horizontal arm is down on
the vertical C-arm at its lower limit, and the thermal head is in next to the horizontal arm and
stowed toward the rear of the machine. Use appropriate weight lifting equipment when
removing/servicing the Air Chiller module.
WARNING 13: Two persons are required when removing (or installing) the thermal head
assembly at the end of the horizontal arm. One person must lift the thermal head assembly by
the head’s front handles, using both hands, while the other person loosens (or tightens) the
pivot lock.
TYPE DESCRIPTION (per SEMI S2-93A) EXPOSURE
THRESHOLD
1 Fully de-energized (electrically “cold.”) n.a.
2 Live circuits, covered or insulated. Work performed
at remote location to preclude accidental shock. n.a.
3 Live circuits exposed.
Accidental contact is possible.
<= 30v RMS, 42.2v peak,
240 volt-amps, and 20
Joules
4 Live circuits exposed.
Accidental contact is possible.
> 30v RMS, 42.2v peak,
240 volt-amps, and 20
Joules
5 Energized. Measurements & adjustments require
physical entry, or equipment configuration does not
allow use of clamp-on probes.
n.a.

1SAFETY
Warnings
1-4 ATS -545 & -645 Interface & Applications Manual
WARNING 14: To prevent high-pressure ejection of condensate (which may or may not
contain injurious substances) when draining moisture from the air filter elements, first turn off
the System's air pressure supply, second bleed all air from the System by turning on ac power
to the System just long enough to exhaust air in the System, third disconnect the supply line
from the air supply port fitting located on the rear panel.
WARNING 15: When cleaning condenser air inlet fins, (access fins by removing front panel)
use soft brush and/or vacuum cleaner, taking care not to bend inlet fins; as fins have sharp
edges, to prevent getting cut, wear protective gloves and/or do not touch inlet fins directly with
fingers.
WARNING 16: Only use the coolants (heat transfer fluids) and refrigerants specified by the
manufacturer: they are carefully engineered to be safe for operating personnel, to be friendly to
the environment, to operate efficiently, and to not harm the equipment. Do not substitute
unauthorized coolants and refrigerants, nor mix (add) in unauthorized coolants or refrigerants:
doing so can cause warranties to be voided. Wear protective safety eye glasses, gloves, and
apron when filling coolants and refrigerants. Temptronic assumes no liability for damages
caused by use of unauthorized coolants and refrigerants.

. . . . .
SAFETY
Cautions
ATS-545 & -645 Interface & Applications Manual 1-5
Cautions
CAUTION
CAUTION: Refer to Accompanying Documentation
Electrical Hazard
CAUTION: High Voltage, Electrical Shock Hazard
Hot Surface
CAUTION: Hot Surface
Cold Surface
CAUTION: Cold Surface
CAUTION 1: Observe the precautions given on the equipment and within this manual to
prevent damage to the equipment. Only use the equipment for the intended usages specified by
the manufacturer.
CAUTION 2: Unauthorized personnel should not remove from the equipment those panels
which are provided for protection and/or cooling and/or require a tool to remove.
CAUTION 3: Use proper handling and packaging procedures for static-sensitive circuit
boards. Assume that all circuit boards are the static-sensitive type.
CAUTION 4: Before connecting the equipment to its electrical source, check that the ~ (ac)
voltage and frequency to be supplied to the system are correct for those listed on the system’s
data plate (located on the rear panel of the equipment).
CAUTION 5: Disconnect the system’s power cord from its service supply before checking or
replacing any back-up batteries.
CAUTION 6: Be very careful to avoid damaging the two thermocouples which go from the
Head thermal cutout board into the main air stream through various connector/supports. These
thermocouples are very delicate. Do not cut, twist, or bend them as internal connections can be
broken.
CAUTION 7: The weight of the Air Chiller Module is about 175 pounds (79.5 kg), and
counterbalances (is used to stabilize) the System’s frame when the thermal head is extended on
the horizontal arm. If removing the Air Chiller module: a) be careful that the system remains
stable (upright) after the module is removed, b) use appropriate weight lifting equipment when
removing/servicing the Air Chiller module.
CAUTION 8: When removing the flow control board, be extremely careful to avoid flexing
the board when disconnecting the inlet and outlet air hoses. Even a slight flexing of the board
can damage delicate components and/or wiring on the board.

1SAFETY
Cautions
1-6 ATS -545 & -645 Interface & Applications Manual
CAUTION 9: When making the system air connection to the System, hold the AIR INPUT
fitting with a second wrench while tightening the barb fitting to prevent the AIR INPUT fitting
from rotating in the panel.
CAUTION 10: Use suitable Clean Dry Air (CDA) compressed air supply for the System: a) to
prevent premature fouling of the filters/regulator assemblies provided with the System, b) to
prevent ice forming from within the cooling module and possibly reducing or obstructing
output air flow. Improper air supply quality can cause damage to System internal operating
components.
CAUTION 11: Properly use and maintain the provided filters/regulator assemblies. Doing so
prevents moisture and/or compressor oils from being introduced into System operating
components. If left unchecked, moisture and/or compressor oil can cause damages to the
System which are not covered under warranty.
CAUTION 12: To loosen the linear actuator assembly (approximately 3 feet long), first
elevate the system high enough to allow the actuator to drop down clear (use a fork lift truck).
Then loosen the actuator from the rear of the system. Do not position yourself beneath (it is not
necessary to be under) the elevated system.

. . . . .
SAFETY
AVERTISSEMENT
ATS-545 & -645 Interface & Applications Manual 1-7
Section B: CONSIGNES DE SÉCURITÉ POUR LE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERSONNEL EXPLOITANT
AVERTISSEMENT
WARNING
AVERTISSEMENT: Attention
Electrical Hazard
AVERTISSEMENT: Haute tension
Hot Surface
AVERTISSEMENT: Surface chaude
Cold Surface
AVERTISSEMENT: Surface froide
AVERTISSEMENT 1: Des tensions potentiellement dangereuses ainsi que d’autres risques,
tels que la présence de surfaces chaudes ou froides ou d’air comprimé/gaz/vapeurs sous forte
pression existent à certains endroits du système. Ceux-ci sont identifiés et signalés sur le
matériel. Observer soigneusement ces avertissements durant l’installation, l’exploitation, la
maintenance et le dépannage du matériel. Respecter également tous les avertissements énoncés
dans ce manuel. Utiliser le matériel uniquement aux fins spécifiées par le fabricant.
AVERTISSEMENT 2: Les instructions de dépannage contenues dans ce manuel peuvent
exposer le personnel à des tensions élevées, à de l’air comprimé sous forte pression et à des
réfrigérants sous forte pression ou pression négative. Ces dangers peuvent entraîner des
blessures graves, voire mortelles. Ne pas exécuter ces instructions si l’on ne dispose pas des
qualifications nécessaires.
AVERTISSEMENT 3: Pour éviter tout risque de choc électrique, le matériel doit être mis à la
terre en utilisant une prise de terre adéquate, conformément aux codes électriques en vigueur.
AVERTISSEMENT 4: Lors du raccordement des capteurs de thermocouples à l’appareil à
tester (DUT), isoler électriquement les capteurs de manière à protéger les opérateurs de toute
tension dangereuse pouvant exister au niveau du DUT.

1SAFETY
AVERTISSEMENT
1-8 ATS -545 & -645 Interface & Applications Manual
AVERTISSEMENT 5: Les pièces à l’intérieur de la tête thermique fonctionnant à des
températures très élevées ou très basses, tout contact avec ces pièces est dangereux.
N’effectuer aucune maintenance à l’intérieur de la tête thermique tant que le système n’est pas
arrêté. Attendre que la température des pièces de la tête se soit stabilisée aux environs de la
température ambiante.
AVERTISSEMENT 6: Pendant la montée ou la descente de la tête thermique du système, ne
pas mettre les doigts dans l’espace compris entre le capuchon thermique de la tête et l’appareil
à tester.
AVERTISSEMENT 7: Conformément au SEMI S2-93A, les installations électriques sous
tension sont spécifiées par type comme suit:
AVERTISSEMENT 8: Lorsqu’on doit mettre l’équipement hors tension pour pouvoir accéder
sans danger aux circuits, l’OSHA 29 CFR 1910 prescrit la procédure de verrouillage et
d’étiquetage suivante : a) Dans le cas des appareils comportant un cordon d’alimentation
que l’on débranche d’une prise d’alimentation, l’utilisateur final doit fournir et étiqueter un
boîtier verrouillable qui enveloppe complètement la prise et empêche tout rebranchement
accidentel ; b) Dans le cas des appareils reliés par cordon à l’alimentation électrique,
l’utilisateur final doit poser et étiqueter soit un sectionneur à position de verrouillage, soit un
disjoncteur à position de verrouillage, afin d’empêcher tout rebranchement accidentel.
AVERTISSEMENT 9: Pour désactiver le système de manière à remplacer un module sans
risques, couper l’alimentation alternative (arrêt du fonctionnement et mise hors tension), puis
couper l’alimentation pneumatique et purger le système en rétablissant l’alimentation
alternative juste le temps nécessaire pour évacuer tout l’air présent. Débrancher alors le cordon
d’alimentation principal et déconnecter la conduite d’alimentation pneumatique du raccord
d’alimentation pneumatique situé sur le module arrière du châssis. La seule énergie alors
présente dans le système est celle emmagasinée dans des condensateurs électriques. Un gros
condensateur est situé près du compresseur du refroidisseur d’air du système. D’autres gros
condensateurs sont intégrés aux alimentations électriques du système.
AVERTISSEMENT 10: Si l’on doit intervenir sur le module du refroidisseur d’air, seul
un dépanneur en réfrigération breveté (et/ou certifié par l’EPA) agréé par Temptronic
Corporation est qualifié pour manipuler les réfrigérants et recharger le système.
TYPE DESCRIPTION (per SEMI S2-93A) EXPOSURE
THRESHOLD
1 Hors tension s.o.
2 Circuits sous tension, protégés ou isolés.
Exécution des travaux à distance afin d’éviter
tout choc électrique.
s.o.
3 Circuits sous tension exposés.
Risque de contact accidentel
<= 30 V efficaces, 42,2 V
crête, 240 VA, et 20 J
4 Circuits sous tension exposés.
Risque de contact accidentel.
>30 V efficaces, 42,2 V
crête,
240 VA, et 20 J
5 Sous tension. Les mesures et les réglages exigent
un accès physique aux circuits ou l’agencement de
l’équipement ne permet pas l’utilisation de sondes
à pince.
s.o.

. . . . .
SAFETY
AVERTISSEMENT
ATS-545 & -645 Interface & Applications Manual 1-9
AVERTISSEMENT 11: En aucun cas (essai d’étanchéité ou toute autre situation) on ne doit
charger le module du refroidisseur d’air avec un gaz à une pression supérieure à 10,34 bars.
AVERTISSEMENT 12: Le module de refroidissement d’air sert de contrepoids à la tête
thermique. Avant de déposer ce module, s’assurer que le bras horizontal est abaissé au
maximum sur le bras vertical en « C » et que la tête thermique est à proximité du bras
horizontal et repoussée vers l’arrière de la machine. Utiliser un matériel de levage adéquat
pour la dépose et l’entretien du module de refroidissement d’air.
AVERTISSEMENT 13: Deux personnes sont requises pour déposer (ou installer) la tête
thermique à l’extrémité du bras horizontal. Une personne soulève la tête thermique en
saisissant des deux mains les poignées situées à l’avant de la tête pendant que l’autre personne
serre (ou desserre) le dispositif de blocage du pivot.
AVERTISSEMENT 14: Pour éviter une éjection violente du condensat (qui peut ou non
contenir des substances nocives) lorsque l’on évacue l’eau accumulée dans les éléments
filtrants du filtre à air, procéder comme suit : 1) couper l’alimentation pneumatique du système
; 2) purger complètement le système en le mettant sous tension juste le temps nécessaire pour
évacuer tout l’air présent ; 3) déconnecter la conduite d’alimentation pneumatique du raccord
d’alimentation pneumatique situé sur le panneau arrière du châssis.
AVERTISSEMENT 15: Lors du nettoyage des ailettes d’admission d’air du condenseur
(accessibles en déposant le panneau avant), utiliser une brosse douce et/ou un aspirateur en
veillant à ne pas déformer ces ailettes ; les ailettes ayant des bords acérés, porter des gants
protecteurs pour ne pas se couper et/ou ne pas toucher les ailettes directement avec les doigts.
AVERTISSEMENT 16: N’utiliser que les liquides de refroidissement (fluides caloporteurs)
et les réfrigérants spécifiés par le fabricant : ils sont spécialement conçus pour la sécurité du
personnel et la protection de l’environnement et pour offrir un bon rendement d’exploitation et
ne pas endommager le matériel. Ne pas leur substituer des liquides de refroidissement ou
réfrigérants non autorisés, ni les mélanger avec de tels liquides ou réfrigérants : ceci entraînera
une annulation des garanties. Porter des lunettes, des gants et un tablier de protection durant les
remplissages avec ces liquides et réfrigérants. Temptronic n’accepte aucune responsabilité en
cas de dommages dus à l’emploi de liquides de refroidissement et réfrigérants non autorisés.

1SAFETY
ATTENTION
1-10 ATS -545 & -645 Interface & Applications Manual
ATTENTION
CAUTION
ATTENTION: Attention
Electrical Hazard
AVERTISSEMENT: Haute tension
Hot Surface
AVERTISSEMENT: Surface chaude
Cold Surface
AVERTISSEMENT: Surface froide
ATTENTION 1: Se conformer aux mesures de sécurité figurant sur le matériel et dans
ce manuel pour ne pas endommager le matériel. N’utiliser le matériel qu’aux fins
spécifiées par le fabricant.
ATTENTION 2: Seul le personnel autorisé est habilité à déposer les panneaux de
refroidissement et/ou de protection et/ou ceux dont la dépose exige l’emploi d’un
outil.
ATTENTION 3: Respecter les procédures de manutention et d’emballage applicables
aux cartes de circuit imprimé sensibles à l’électricité statique. Considérer a priori que
toutes les cartes sont sensibles à l’électricité statique
ATTENTION 4: Avant de raccorder le matériel à son alimentation électrique, s’assurer
que la tension alternative ~ et la fréquence fournies au système correspondent à celles
indiquées sur la plaque signalétique (située sur le panneau arrière).
ATTENTION 5: Débrancher le cordon d’alimentation du système de sa source
d’alimentation avant de vérifier ou de remplacer les batteries de secours.
ATTENTION 6: Veiller soigneusement à ne pas endommager les deux thermocouples
allant de la découpe thermique de la tête au flux d’air principal par l’intermédiaire de
différents supports et connecteurs. Ces thermocouples sont très fragiles. Ne pas les
couper, les tordre ou les plier car cela risque de rompre leurs connexions internes.
ATTENTION 7: Le module de refroidissement d’air pèse environ 79,5 kg, et il sert de
contrepoids (de stabilisation) au châssis du TP04200A lorsque la tête thermique est
déployée sur le bras horizontal. Si l’on dépose le module de refroidissement d’air : a)
veiller à ce que le système reste stable (vertical) une fois le module déposé, b) utiliser
un matériel de levage adéquat pour faire la dépose/l’entretien du module de
refroidissement d’air.
This manual suits for next models
1
Table of contents
Other inTest Test Equipment manuals