Intracom WiBAS OSDR Quick start guide

Start Up &
Commissioning Manual
Edition 5.1
GDC-003/63
Confidential

INTRACOM TELECOM
19.7 km Markopoulou Ave., Peania, Athens, GR 19002
T +30 210 667 1000, F +30 210 667 1001
http://www.intracom-telecom.com
email (product support): wireless-support@intracom-telecom.com
The information contained in this document is subject to change without prior notice.
INTRACOM S.A. TELECOM SOLUTIONS, 2019.All rights reserved.
All copyright, intellectual and industrial rights in this document and in the technical knowledge it contains
are owned by INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners.
This document is made available to the end users only for their internal use.
No part of this document nor any data herein may be published, disclosed, copied, reproduced,
redistributed by any form or means, electronically or mechanically, or used for any other purpose
whatsoever without the prior written approval of INTRACOM S.A. TELECOM SOLUTIONS.
Information as well as drawings and specifications contained in this document are subject to change
without prior notice.
All trademarks and copyrights mentioned herein are the property of INTRACOM S.A. TELECOM
SOLUTIONS and/or their respective owners.
Any rights not expressly granted herein are reserved.
Printed in Greece.

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
-3-
Document Revision History
Previous Edition: 5.0
Current Edition: 5.1
Reasons of Change
M
=
Modified,
A
= Added,
R
= Removed
Details
Configuring Operational Parameters on page 32
(M) •WiBAS-Connect TS (Auto-
Polarization Edition) on
page 38 added.
Appendix C – Quality Indicator Thresholds on page
93 (M) Table modified.

(Page intentionally left blank)

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
-5-
Equipment Disposal
Disposal of old electrical and electronic equipment (applicable through the
European Union and other European countries with separate waste collection
systems).
This symbol, found on this product and any of its parts or on its operating instructions
or on its packaging, indicates that electrical and electronic equipment may not be
disposed of as unsorted municipal waste. Instead, this product should be handed over
to applicable collection points for the recycling of electrical and electronic equipment.
By ensuring the correct disposal of this product, you will help prevent potential
negative consequences to the environment and human health, which could otherwise
be caused by inappropriate disposal of this product.
By recycling, reusing and other forms of recovery of old electrical and electronic
equipment you are making an important contribution to the conservation of natural
resources and to the protection of the environment.
For more information about the recycling of this product, please contact your local
municipal authorities, municipal waste disposal service or the store where you
purchased this product.
Απόρριψη παλαιών ηλεκτρικών και ηλεκτρονικών συσκευών (ισχύει στην
Ευρωπαϊκή Ένωση και άλλες Ευρωπαϊκές χώρες με συστήματα χωριστής
συλλογής απορριμμάτων).
Το σύμβολο αυτό, που απεικονίζεται πάνω στο προϊόν και σε τυχόν εξαρτήματα του
ή στο εγχειρίδιο οδηγιών του ή στη συσκευασία του, δείχνει ότι οι ηλεκτρικές και
ηλεκτρονικές συσκευές, μετά το πέρας της λειτουργίας τους, δεν θα πρέπει να
απορρίπτονται μαζί με τα αστικά απόβλητα. Αντίθετα θα πρέπει να παραδίδονται σε
κατάλληλα σημεία συλλογής για την ανακύκλωση των ηλεκτρικών και ηλεκτρονικών
συσκευών.
Διασφαλίζοντας τη σωστή απόρριψη αυτού του προϊόντος, συνεισφέρετε στην
πρόληψη πιθανών αρνητικών συνεπειών στο περιβάλλον και την ανθρώπινη υγεία,
οι οποίες θα μπορούσαν να προκληθούν από την μη ενδεδειγμένη απόρριψη του
προϊόντος.
Η ανακύκλωση, επαναχρησιμοποίηση και άλλες μορφές αξιοποίησης των παλαιών
ηλεκτρικών και ηλεκτρονικών συσκευών βοηθούν στη διαφύλαξη των φυσικών πόρων
και στην προστασία του περιβάλλοντος.
Για περισσότερες πληροφορίες σχετικά την ανακύκλωση αυτού του προϊόντος,
παρακαλούμε επικοινωνήστε με τις τοπικές δημοτικές αρχές, την υπηρεσία
αποκομιδής αστικών αποβλήτων ή το κατάστημα από το οποίο αγοράσατε το
συγκεκριμένο προϊόν.
Για περισσότερες πληροφορίες, μπορείτε να επικοινωνείτε με το Συλλογικό Σύστημα
Εναλλακτικής Διαχείρισης Αποβλήτων Ηλεκτρικού και Ηλεκτρονικού Εξοπλισμού
“Ανακύκλωση Συσκευών Α.Ε.” (www.electrocycle.gr).

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
-6-
Declaration of Conformity
English
Hereby, Intracom S.A. Telecom Solutions declares that the product
WiBASTM is CE marked in compliance with the essential requirements and
other relevant provisions of the Radio Equipment Directive 2014/53/EU, Eco
Design Directives 2009/125/EC, 2010/30/EU and with the requirements of
the RoHS directive 2011/65/EU.
The full text of the EU declaration of conformity is available at the
following URL: http://emc.intracom-telecom.com/en/start.htm
Δήλωση Συμμόρφωσης
Greek
Με την παρούσα, η Intracom Α.Ε. Τηλεπικοινωνιακών Λύσεων δηλώνει ότι
το προϊόν WiBASTM φέρει την σήμανση CE συμμορφούμενο προς τις
απαιτήσεις και τις λοιπές διατάξεις των οδηγιών Radio Equipment Directive
2014/53/EU, Eco Design Directives 2009/125/EC, 2010/30/EU καθώς και με
τις απαιτήσεις της οδηγίας RoHS 2011/65/EU.
Το πλήρες κείμενο της δήλωσης συμμόρφωσης (EU) είναι διαθέσιμο στην
ακόλουθη διεύθυνση URL: http://emc.intracom-telecom.com/en/start.htm

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
7
Table of Contents
1. Introduction.........................................................................................................................9
About this Document..........................................................................................................9
Safety Precautions...........................................................................................................11
About WiBAS-OSDR Hub / TS and WiBAS-Connect........................................................ 12
2. Before Starting the Commissioning.................................................................................13
Prerequisites ....................................................................................................................14
Hardware & Software Requirements ................................................................................ 16
Required Tools.................................................................................................................17
3. Powering Up......................................................................................................................18
Powering through DC Power Injector................................................................................ 19
Powering through AC Power Injector................................................................................21
4. Physical Management Connection...................................................................................23
4.1. WiBAS-OSDR Hub & TS..................................................................................................24
INBAND Management Connection (through GbE2 port)...................................................24
INBAND Management Connection (through GbE1 port)................................................... 25
OUTBAND Management Connection...............................................................................26
4.2. WiBAS-Connect TS..........................................................................................................27
INBAND Management Connection...................................................................................27
5. Accessing a Radio Unit via Node Manager ..................................................................... 28
Default IP Address ...........................................................................................................28
Accessing a Radio Unit ....................................................................................................29
6. Equipment Commissioning.............................................................................................. 30
6.1. Performing Preliminary Actions ........................................................................................31
6.2. Configuring Operational Parameters ................................................................................ 32
WiBAS-OSDR Hub...........................................................................................................32
WiBAS-OSDR TS.............................................................................................................34
WiBAS-Connect TS..........................................................................................................36
WiBAS-Connect TS (Auto-Polarization Edition)................................................................38
6.3. Antenna Alignment...........................................................................................................40
Connect RSSI Cable ........................................................................................................42
WiBAS-OSDR Hub...........................................................................................................44
WiBAS-OSDR TS.............................................................................................................45
WiBAS-Connect TS..........................................................................................................53
WiBAS-Connect TS (Auto-Polarization Edition)................................................................68
6.4. Checking Operation..........................................................................................................81
6.5. Service Provisioning.........................................................................................................83
Appendix A – LED Indications .............................................................................................85

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
9
1. Introduction
About this Document
Scope of
Document The scope of this document is to provide detailed instructions on the startup
and commissioning of the following PtMP products:
•WiBASTM - OSDR Hub & Terminal Station
•WiBASTM - Connect Terminal Station
The commissioning is performed via Node Manager(1).
Target
audience The procedures described in current document can be carried out ONLY by
wireless certified technician with the following skills:
•Wireless installation inspection (pole installation, cabling, grounding,
powering e.t.c)
•Coarse and Fine antenna alignment (for Hub and Terminal Station)
•System commissioning using laptop and telecom software.
•System services provisioning.
Software
version This document applies in a specific software release.
The Release version as well as the Release Notes of product are available
and provided by the product support (wireless_support@intracom-
telecom.com) of Intracom S.A. Telecom Solutions.
Reference
manuals The reference manuals are listed below:
Item
Description
1
OSDR Installation Manual.
2
WiBAS-Connect Installation Manual.
3
WiBASOSDR Node Manager Manual.
4
OSDR_WiBAS-Connect Product Catalog.
Continued on next page
(1) Embedded application.

1. Introduction
10
About this Document, Continued
Conventions This document applies to the following conventions:
•Arial Bold blue fonts are used for order codes.
•Arial Blue underline fonts are used for document references.
•Arial Bold black fonts are used for indicating important information or
paragraph header.
This symbol means DANGER. The purpose of this symbol is to warn
you that any wrong action can cause bodily injury or even death.
This symbol means CAUTION. The purpose of this symbol is to
prevent you from performing an action that might result in damage of
the equipment.
The purpose of this symbol is to protect you from unauthorized entry
to the site and damage your equipment.
A note calls your attention to important supplementary information.
A hint denotes helpful piece of advice or practical suggestion.

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
11
Safety Precautions
Reference Before starting any commissioning works please follow the safety
precautions as described to the following reference manuals:
Product
Reference Manuals
Description
Chapter No.
Paragraph
WiBAS OSDR Hub OSDR
Installation
Manual 1 Safety
precautions
WiBAS OSDR Terminal Station
WiBAS-Connect Terminal Station WiBAS-
Connect
Installation
Manual

1. Introduction
12
About WiBAS-OSDR Hub / TS and WiBAS-Connect
Overview
This document describes the startup & commissioning of the products shown
below.
The dimension of parabolic integrated antennas is indicative. For more information
regarding antennas dimension please refer on page 9, item 4 of Reference manuals.

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
13
2. Before Starting the Commissioning
Prior to starting the commissioning of a WiBAS OSDR-Hub or Terminal
station and WiBAS-Connect , verify that the prerequisites mentioned below
are fulfilled and all required HW / SW and mechanical tools are available.
Topic Page
Prerequisites 14
Hardware & Software Requirements 16
Required Tools 17

2. Before Starting the Commissioning
14
Prerequisites
Required
commissioning
data
Commissioning data at site should be entered according to Radio and
Network planning.
The following commissioning data should be available before starting
commissioning works on site:
•RF planning values: expected RSSI, SNR, Modulation and Tx Power.
•Modem and Radio configuration data: Bandwidth, Tx Frequency and ACM
& ATPC Profiles.
•Management settings: IP Address, Subnet Mask, Gateway Address and
Management VLAN.
On-site works Before starting any commissioning actions, ensure that all the following
works have been carried out on site according the below table:
Check about Reference Manuals
Description Chapter No. Paragraph
Radio unit grounding.
OSDR
Installation
Manual 4 4.2
WiBAS-
Connect
Installation
Manual
4 4.4
Radio unit cabling.
OSDR
Installation
Manual 3 3.2
WiBAS-
Connect
Installation
Manual
3 Radio unit
cabling.
Power injector installation
OSDR
Installation
Manual Appendix C All
WiBAS-
Connect
Installation
Manual
Appendix D All
Continued on next page

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
15
Prerequisites, Continued
Antenna
orientation •The antenna orientation of WiBASTM–OSDR Hub should be carried out
toward the planned service area, as specified in the radio planning
document.
•The antenna orientation of terminal stations should be carried out toward
to the corresponding WiBASTM–OSDR Hub sector, as specified in the
radio planning document.
Number of
commissioners
required
For the commissioning of the base station one commissioner is required.
For the link commissioning between a terminal station and a base station,
one commissioner is required (terminal side).

2. Before Starting the Commissioning
16
Hardware & Software Requirements
Scope This paragraph provides the hardware and software resources required to
perform commissioning procedures on WiBAS-OSDR Hub / TS & WiBAS-
Connect.
Laptop Laptop with the following minimum requirements:
•CPU x86, 9th generation (Intel Core 2 or AMD ATHLON II Neo)
•250 MB HDD
•2 GB RAM
•Ethernet (RJ-45) port
•Windows 7 or later version
•Web Browser(1)
Software •Appropriate License.
•Latest WiBAS firmware upgrade pack.
CAT5 Ethernet
cable CAT-5 or higher Gigabit Ethernet straight cable (for outband management).
RSSI cable RSSI cable for antennas alignment (available by Intracom S.A Telecom
Solutions).
WiBAS-OSDR Hub / TS
WiBAS
TM
-Connect
(1) For details on the compatible Web Browsers, please refer to Node Manager for WiBAS OSDR
Reference Manual (Chapter 2, par. Log in).

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
17
Required Tools
Tools
Description
Digital Voltmeter.
For measuring:
•Power injector input power.
•The RSSI of radio unit during antennas
alignment.
Adjustable torque U-wrench (up to 19 mm
opening and supporting max tightening
torque 45 Nm) for applying final tightening
torque to all antennas mounting kit.
A set of spanners (ring and open jaw) for
pre-tightening the mounting kit during
alignment process:
Description Size / Dimension Qty
Parabolic
and sectoral
integrated
antennas
M10 (17 mm A/F) 2
M12 (19 mm A/F) 2
WiBAS-
Connect
parabolic low
profile and
panel
antennas
M8 (13 mm A/F) 2
Adjustable torque wrench tool (supporting
max tightening torque 25 Nm).
Hexagon male bit for adjustable torque
wrench tool (for tightening WiBAS-OSDR TS
mounting kit with panel antenna).
T10 TORX bit for adjustable torque wrench
tool (for tightening outdoor DC PonE cover).
Flat slotted screw driver (min 10 mm).
Compass and Binocular for antenna
alignment.

3. Powering Up
18
3. Powering Up
Scope This chapter provides information on powering up a radio unit through a
power injector.
Intracom Telecom provides the following power injectors(1):
Radio Unit Order Code Use Input
Power Hardened
Construction Output
Power
Connect POE-ID-AC35 Indoor AC 35 W
Hub POE-AC56-IDH Indoor 56 W
Hub-TS PONE-OD-DC Outdoor DC
60 W
Hub-TS PONE-OD67-AC Outdoor AC
67.2 W
Hub(2) POE-AC75-ID Indoor AC 75 W
Prerequisite
Prior to powering up a radio unit, ensure that all On-site works
(mentioned on page 14) have been carried out as instructed in the
OSDR Installation & Cabling Manual.
(1) After interoperability confirmation by Intracom Telecom, other types of power injectors can also be used.
(2) 72 W POE also is applicable (POE-AC72-ID).

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
19
Powering through DC Power Injector
Introduction DC power cable coming from the DC power injector(1) must be connected to
a DC Distribution Board.
A circuit breaker(2) must be employed between the blue wire of DC power
cable and the negative pole (-) V pole of the Local DC Power Source.
The positive pole (+) V of the Local DC Power Source, which the brown wire
of DC power cable is terminated on, is grounded.
Circuit breaker must remain to the OFF position until the
power at the input of radio (Vin) to be checked.
Vin must be measured in the range of -60 V to -40 V.
Procedure To power up radio unit using the DC power injector, please follow the steps
below:
Step Action
1 Ensure that circuit breaker is in OFF position and connect a
voltmeter to DC Distribution Board to measure the voltages at the
input (IN) of circuit breaker (see schematic above).
The measurement value must be in the range of: -60 ≤ Vin ≤ -40.
2 If measurement value is ok, disconnect the voltmeter and switch
ON the circuit breaker.
3 Wait (approx. 120 sec) for the radio unit to power up.
Continued on next page
(1) DC power injector code: PONE-OD-DC
(2) Single-pole MCB 6A, 72 Vdc, C-curve for Telecom Applications.
This manual suits for next models
3
Table of contents
Popular Conference System manuals by other brands

AT&T
AT&T PARTNER II Release 3.1 installation guide

Palm Radio
Palm Radio Palm Portable Key Quick start manual

LifeSize
LifeSize Passport Series user guide

Polycom
Polycom RPX HD 400 Series Release notes

Texas Instruments
Texas Instruments TI-Nspire CX Navigator 4.2 Faq

Yealink