CONTROL PADS ON THE DEHUMIDIFIER
NOTE: The control panelof the unityou purchased maybe slightly taccording to the
models.
CONTROL PADS ON THE DEHUMIDIFIER
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied.
When frost builds up on the evaporator coils, the
compressor will cycle o and the fan will continue
to run until the frost disappears.
Auto Defrost
Wait 3 minutes before resuming operation
After the unit has stopped, it will not restart operation
for three minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
Setting the Timer
When the unit ison, press the Timer
button, the Timer indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again and the
TimeOn indecator lightilluminates.It
indicates the Auto Start is initiated.
Press or hold theUPor DOWN pad to
change theAuto time by 0.5 hour incre-
ments, up to10 hours, then at 1hour
increments upto 24hours. The control
will count down the time remaining until
start.
The selected time will register in 5seconds
and the system will automatically revert
back to display the previoushumidity
setting.
When theAuto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ONand OFF times are
now programmed.
Turning the unitON or OFFat any timeor
adjusting thetimer setting to 0.0 willcancel
theAuto Start/Stop function.
When the LED display window displays the
code of P2, theAuto Start/Stop function
will also becancelled.
When the unit is press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again and the
Time indecator lightilluminates.It
indicates theAutoStop is initiated.
Check feature
The system starts to count the time once the fan
motor operates. The check feature can be
only activated when the accumulated operation
timeachieves 250 hours or more. The Reset
light(Clean indicator light) at one time
persecond, after clean the air press
the Filter pad and the Reset light(Clean indicator
light) goes o .
Auto Shut O
The shuts when the bucket is
full, or when the bucket is removed or not replaced
in the proper position. When the set humidity level
For some models,the fan motor will continue
operating.
Auto-Restart
it will restart with the previously set functions automatically
when the power resumes.
Control pads
When you pushthe button tochange
operation modes, theunit will make
a beep soundto indicate thatit is
changing modes.
Humidity Set Control Pads
: Up/Down Pads
TIMER Set Control Pads
Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air,press the pad and set to a lower
percent value(%).
For damper air,press the pad and set a higher
percent value(%).
Timer Pad
Press to initiate the Auto start and Auto stop feature,
in conjuction with the and key pads.
11
7
6
5
Power Pad .
22
COMFORT Pad(optional)
Press to activate the comfort dehumidifying operation.
NOTE: In this operation, the unit's humidity level can not
be set.
33
CONTINUE Pad
Press to activate the c
ontinuous dehumidifying operation.
TURBO Pad
Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
( 5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS - Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES - Tube Temperature sensor of the evaporator error-- Unplug
the unit and plug it back in. If error repeats, call for service.
P2-- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.(only available for
the uint with no pump feature.)
EC - Refrigerant leakage detection-- With this new technology,
the display area will appear EC when the unit detects
refrigerant leakage, call for service.
E3 - Unit malfunction-- Unplug the unit and plug it back in. If
error repeats, call for service.
Eb - Bucket is removed or not in right position-- Replace the
bucket in the right position.(only available for the unit with
pump feature.)
Fig.1a
High fan
indicator light
On
Off
Full
2
Clean filter
indicator light Continuous
operation on
indicator light
Timer on/off
indicator light
1
Auto defrost
3 4 5 6 7
8
8
Auto defrost operation
on indicator light
Bucket full
indicator light
Comfort dehumidifying
operation on
indicator light
FILTER Pad
shows AP to indicate you can set WiFi connection. If connection
(router) is successful within 8 minutes, the unit will exit WiF
connection mode automatically and the WiFi indicator
illuminates. If connection fails within 8 minutes, the unit exits
the WiFi connection mode automatically.