inXite DX1000 Disinfection Robot User manual

DX1000 Disinfection Robot
www.inxite360.com
Disinfection Robot
Product Manual

DX1000 Disinfection Robot
www.inxite360.com
PRODUCT MANUAL
Statement
Copyright © 2020 InXite Data Systems LLC. All rights reserved.
Unless otherwise permitted by InXite Data Systems LLC. in writing, no companies or
individuals may copy, replicate, transcribe or translate the contents of the manual, whether
in part or in whole, nor spread it in any way (electronic, photocopying, and recording, etc.)
for lucrative purpose.
The product specications and information specied herein are for reference only. No prior
notice will be given when content is updated. Unless otherwise specied, this manual is only
for instructional use only. The statements made hereunder shall not constitute any form of
warranty.

DX1000 Disinfection Robot
www.inxite360.com
Introduction
Dear users,
Thank you for choosing the DX1000
Disinfection Robot. Before using your robot,
please read this manual in its entirety.
James Paat
President Inxite360
Introduction to the
Product Manual
This manual describes the functional
characteristics, methods of installation and
use of the DX1000 Disinfection Robot.
This manual includes the following
contents:
1. About the Robot: Gives a short description
on the basic functional characteristics of the
robot and shows the structure of the robot in
detail.
2. Operating Steps: Gives a description on
how to prepare the robot for usage.
3. Appendix: Describes common errors and
detailed technical parameters of the robot, as
well as safety precautions.

DX1000 Disinfection Robot
www.inxite360.com
Table of Contents
DX1000 Disinfection Robot............................................................................................1
Statement.......................................................................................................................1
Introduction ..................................................................................................................3
Introduction to the Product Manual .............................................................................3
About the DX1000 Robot ..............................................................................................5
Main Structure of the Robot .........................................................................................6
Operating steps (Use robot) .........................................................................................7
Installation ....................................................................................................................7
Power on ......................................................................................................................7
Charging .................................................................................................................10
Filling Disinfectant .....................................................................................................10
Description on state of indicator light...........................................................................10
Emergency treatment ...................................................................................................11
Handling the robot ......................................................................................................12
Appendix .................................................................................................................12
List of Exception and Troubleshooting..........................................................................12
Performance parameters of the Machine......................................................................13
Safety instructions ......................................................................................................14

DX1000 Disinfection Robot
www.inxite360.com
Fig. 1 Structure diagram of the DX1000 Disinfection Robot
Note: The above gure is for reference only. The appearance and color of specic products
shall be subject to the actual products.
Front View Side View Rear View
About the DX1000 Robot
The DX1000 Disinfection Robot should
only be operated in indoor spaces, such as
nursing homes, hospitals, quarantine areas,
hotels, business ofces, etc.
The DX1000 Disinfection Robot is fully
autonomous and navigates via intelligent
obstacle avoidance through machine vision
and laser radar to provide disinfection and
sterilization services.

DX1000 Disinfection Robot
www.inxite360.com
Main Structure of the Robot
Fig. 1 shows the main structure of the DX1000 Disinfection Robot. The robot chassis has two
driving wheels and four driven wheels. Autonomous movement is made through machine
vision and laser radar. Intelligent obstacle avoidance function is realized through integrated
application of different sensors such as contact sensors. Users are able to operate the robot
system through the touchscreen.
Fig. 2 shows the structure of the DX1000 charging station. The robot is enabled with intelligent
autonomous recharge, allowing the robot to independently nd, match and contact the
charging port to automatically recharge.
Fig. 2 Structure diagram of charging port

DX1000 Disinfection Robot
www.inxite360.com
Operating steps (Use robot)
Please follow the following steps to operate your robot.
Installation
1. Robot mapping
Before moving, the robot needs to check the surrounding environment. It stores and identies
its operating environment in the form of a map. This step is called mapping.
Power on
1. Power on/off
The power switch is located on the lower surface of the gap (near liquid injection port) in the
laser layer of the robot. You may nd the power switch in the position shown in g. 3. Start
the robot by pressing the power switch upward with your nger. It will take about 40 seconds
to start the system before operation.
To turn off the robot, press the power switch downward.
Fig. 3 Schematic diagram of power switch position

DX1000 Disinfection Robot
www.inxite360.com
2. Mobile app instructions
2.1 Introduction of functions
To disinfect, follow these steps:
1. Select “disinfection” mode.
2. Select the route to the desired destination or moving point. The robot will then travel to each
destination after departure.
3. Upon arrival at destination (or route area), the robot will send a voice prompt, turn on its
disinfection equipment, and conduct continuous disinfection task for a given period of time.
4. After completion of disinfection, the robot will automatically return to its original location.
2.2 Disinfection mode
The robot has three modes of disinfection:
1. On-the-way mode: open the nozzle for spraying disinfection along the route.
2. Fixed-point mode: operate ultraviolet disinfection for one single room.
3. Dual mode: UV and spraying sanitization functions are activated at the same time for
disinfection of a single room.
Under the “on-the-way” mode, the user may select up to four routes. Press on the power switch
to start the robot. When the robot arrives at the starting point of the rst route, it will begin
spraying disinfection and continue this operation along the way back and forth. Meanwhile, the
robot will send a voice prompt every two minutes until the disinfection process for a preset num-
ber of cycles is completed. After that, the robot continues to spray on the next route or returns to
the original point. Manual operation is required for this mode.
Under the xed-point mode, the user may select up to four routes. Press the power switch to
start the robot. When it reaches the destination room, the robot will send a voice prompt. Then,
it will operate ultraviolet disinfection while sending a voice prompt every two minutes until the
preset disinfection time is over. After that, the robot continues disinfection operation on the next
point or returns to the original point.

DX1000 Disinfection Robot
www.inxite360.com
Under the dual mode, the user may select up to four routes. Press the power switch to start the
robot. When it reaches the destination room, the robot will send a voice prompt. Then, it operates
both ultraviolet and spraying disinfection while sending a voice prompt every two minutes until
the preset disinfection time is over. After that, the robot continues disinfection operation on the
next point or returns to the original point. Please keep away from the robot under the xed-point
mode and dual mode to prevent damage caused by ultraviolet radiation.
In the disinfection process, each mode supports the functions of suspending disinfection and
ending tasks, and the interface of the robot displays the remaining disinfection time or spraying
disinfection mileage.
Upon completion of each disinfection task, the main interface will update to display the analytics
of the day, such as accumulative total disinfection duration, accumulative total disinfection
mileage and task load.
2.3 Settings
Press the “Settings” button at the top left of the main page and enter the 4-digit password to
enter the Settings page.
Users can set the number of cycles for spraying disinfection, duration of stay, intensity of spraying,
sound volume, new password, motor unlock switch during pause, working time, instant charging,
and so on.
Among these settings, the number of cycles for spraying disinfection is only available for “on-the
way” mode. It refers to the number of cycles for spraying disinfection by the robot on the given
route. Users can set 1-5 times, or unlimited times for the number of cycles.
Intensity level of spraying: refers to the speed in which the robot sprays when under the “on-
the-way” mode and “dual” mode. The speed of spraying is divided into 5 levels. Level 1 is the
slowest while Level 5 is the fastest. With the speed increase, the amount of spraying increases and
the disinfection efciency will be higher.
Duration of stay: refers to the irradiation time (15-90 minutes) under the xed-point mode and
dual mode with the ultraviolet equipment turned on. The longer the irradiation time, the better
the disinfection effect will be achieved.
Motor unlock switch during pause: if this function is turned off, the user clicks on the screen, and
the motor will not unlock when the robot pauses, then the user cannot push the robot to move.

DX1000 Disinfection Robot
www.inxite360.com
Charging
1. Robot Autonomous Intelligent Recharge
The robot has the function of intelligent autonomous recharge. The robot will return to the
charging port to recharge if both two conditions bellow are met. Please ensure that the charging
port is secured in position and energized.
The electric quantity of the robot is lower than the recharge value set by the user. The robot is
idle and its electric quantity does not reach 100%.
2. Adapter charging (robot operation is prohibited during adapter charging) The robot can be
charged through the adapter as follows:
Power off the machine.
Open the silicone sleeve outside the [Charging port] on the back of the robot and connect the
robot with the charging plug of the adapter.
After successful connection, the adapter indicator will turn red (if the indicator light is yellow,
press the indicator light, then the light it will turn red).
The charging is complete when the adapter indicator light turns yellow. Then, disconnect the
adapter and plug the silicone sleeve outside the charging socket of the robot.
Filling Disinfectant
The user should ll the robot with disinfectant if the robot indicates that the liquid level is too
low. The lling port is located at the rear side of the machine body. Lift the silicone cover, press
the blue knob, and then rotate counterclockwise to open the cover, as shown in g. 4.
Fig. 4 Partial enlarged detail upon opening the outer silica gel cover of the liquid lling port

DX1000 Disinfection Robot
www.inxite360.com
Indicator light state Meaning
Blue breathing light (slow blinking) The robot is in standby mode. The spraying
device and the ultraviolet lamp are not on.
Blue operation lamp (rotating) The robot is in operation, with spraying
device or ultraviolet lamp on.
Blue Warning Light (fast blinking) Warning - ultraviolet lamp will be turned on
soon.
Orange breathing light (slow blinking) The robot is low on disinfectant.
Description on state of indicator light
Emergency treatment
When the robot is moving, if the user needs to push and move the robot by hand, or the
robot is in abnormal operation that may cause damage to the surrounding environment,
or some other emergency event occurs, the user can stop the robot by pressing the red
emergency stop button on the top of the robot. The position of the emergency stop button
and how to operate the button are shown in g. 5
Fig. 5 Partial enlarged detail after opening the emergency stop button cover
The emergency stop button is located at the back of the robot, i.e. the position indicated by
reference No. 11 in the gure. For emergency stop, you should rst open its cover outwards. Then,
break the acrylic protection plate in the middle layer. Lastly, press the red emergency stop button.
* Note:
The user is required to break the acrylic protection plate before pressing the emergency stop button.
Therefore, please don’t use this button unless an emergency event occurs.

DX1000 Disinfection Robot
www.inxite360.com
Handling the robot
Robots are expensive, so please follow the instructions below when moving the robot manually.
As shown in g. 6, the upper part of the robot laser layer gap (the surface indicated by the arrow) is
the force-bearing part, through which you can lift the robot. Please hold the upper part of the laser
layer with your hands when handling. Please keep the robot upright at all times when handling.
Fig. 6 Schematic diagram for handling the robot
* Note:
The laser layer gap is the only force-bearing part of the robot to be handled. When moving
robots, you should strictly follow the instructions. Do not pull and lift the bottom of the robot,
turn over the robot, or directly lift the robot’s face and head. The damage to the robot caused
by improper operation during handling shall be borne by the user.

DX1000 Disinfection Robot
www.inxite360.com
Appendix
List of Exception and Troubleshooting
Failure Problem Possible Causes and Solutions
The user cannot turn on the robot 1. There is an electricity shortage – charge the robot via
the adapter.
2. For other causes, please contact customer service.
Failure to charge normally 1. Press the yellow indicator light of the adapter; the indi-
cator will turn red.
2. For other causes, please contact customer service.
Robot cannot move or
navigate
1. The robot is in the blind area of the map. Turn off the
robot and push it to the vicinity of the starting point to
start navigation again.
2. The top camera, stereo vision or laser layer gap is
covered. Ensure that the above modules are not covered.
3. Robot radar failure. Check the rotation of the laser radar.
4. Robot collision switch failure. Check whether the
collision switch is squeezed.
5. For other causes, please contact customer service.
Abnormal robot movement Turn off the power supply of the machine immediately and
contact customer service for disposal.
Robot falls Turn off the power supply of the machine immediately and
contact customer service for disposal.

DX1000 Disinfection Robot
www.inxite360.com
Performance parameters of the Machine
Model DX1000 Disinfection Robot
Dimension 500*500*1350 mm
Disinfectant volume 15L
Spraying Parameter Spraying output: 2-4L/h; Spray particle size
10µm.
Number of ultrasonic atomization sets 6 sets of ultra-dry atomizing nozzles
Applicable disinfectant Hydrogen peroxide, hypochlorous acid, and
peroxyacetic acid
Ultraviolet radiation intensity Each group: >90µW/cm²
Number of ultraviolet lamps Four sets of UVC ultraviolet germicidal lamps,
with 360 ° coverage for irradiation
Disinfection method
( three methods for choice)
Ultrasonic dry spray disinfection
Ultraviolet irradiation disinfection
Ultrasonic dry spray disinfection +
Ultraviolet irradiation disinfection
N.W. 70Kg
Moving speed 0-0.8m/s
Maximum climbing angle Slope ≤ 3°
Network interface WIFI/4G/ Bluetooth
Battery capacity DC 48V 15Ah
Rated power 90W
Standby current Standby current is less than 0.5A
Endurance time Work continuously for more than 8 hours
Standby time Standby time is greater than 48 hours
Life span 20,000 h
Temperature and humidity operation 0-45, RH: 5%-85%, no dust
Operation environment Indoor environment, at and smooth ground
Charging mode Automatic/manual charging
Input voltage input rated voltage for charging port and
adapter: 220V/50Hz
Storage temperature 0-60 degreed C.

DX1000 Disinfection Robot
www.inxite360.com
Safety instructions
Use restrictions:
As a wheeled robot, the product shall only operate indoors on a at surface (smooth ground; slope:
5°; protrusion height: ≤ 1cm). Do not operate the robot outdoors (such as an open balcony) or
rugged ground (such as stairs).
Do not operate the robot in a suspended environment (e.g. duplex oor, open balcony, top of
house, stairs) or environment without a protective fence.
Do not operate the robot in an environment where the temperature is higher than 50> or lower than
0> or there is liquid or viscous substance on the ground.
Before using the robot, please remove all kinds of wires on the ground in the operating environment
to avoid dragging when the robot is in operation.
Before use the robot, please remove sharp objects on the ground (such as decoration waste, glass,
nails, etc.) to avoid damage to the chassis of the machine.
Do not place any non-transportable objects (including children and pets) on stationary or running
robot.
Do not push or handle the robot while the machine is moving.
Do not arbitrarily move the robot.
Do not clean and maintain the main machine and charging port unless the robot is shut down or
powered off.
Do not use allow hard or sharp objects to collide with the robot.
Do not spill any liquid into this product.
Do not push down the robot or place it upside down.
The robot is an electronic product. Please keep it away from re.
Before handling the product, please ensure that the main machine is powered off. It is
recommended to use the original packaging box for packaging.
Please use this product according to the instructions in the user manual or the introduction guide.
Any loss or injury caused by improper use shall be borne by the user.
Battery and charging:
Do not use any battery or power adapter from a third party.
Do not disassemble, repair or ret batteries or charging ports without permission. Do not place the
charging port near a heat source (such as radiator, etc.).
Do not wipe or clean the charging port contact piece with a wet cloth or wet hands.
Please recycle old batteries.
If the robot is idle for a long time, please power off the machine upon full charge and put it in a cool
and dry place. Charge it at least once a month to avoid battery damage.

DX1000 Disinfection Robot
www.inxite360.com
Warranty period:
1. Clients can request for return, replace or repair of the products with performance failure due to
the reason other than the operation of the users within 7 days from the date of purchase.
2. Clients can request for replace or repair of the products with performance failure due to the
reason other than the operation of the users within 15 days from the date of purchase.
3. We promise to provide free warranty service for our products with performance failure due to the
reason other than the operation of the users within the warranty period from the date of purchase.
Warranty coverage:
Name Warranty period
Robot 1 year
Non-warranty terms:
The warranty service is only applicable to the products under normal use. Products damaged by
users and the following clauses are not covered by our warranty.
1. Product damage caused by negligence, fault and misuse of users, or disaster (e.g. food liquid
stains, water seepage, external force cracking, scratches and damage of peripheral components,
etc.).
2. Users dismantle the machine by themselves, and repair and ret it without authorization and ap-
proval of the manufacturer.
3. Improper connection of accessories; product damage caused by transportation and other acci-
dents.
4. Damage caused by force movement.
Product information Product model: SN code:
User information Name:
Tel.:
Date of purchase:
Email:
Address: Purchase address:
Sales unit information Distributor:
Stamp of distributor
InXite Date Systems LLC.
www.inxite360.com
1. E Campus View Blvd
Ste. 320
Columbus, Ohio 43235
Table of contents
Popular Robotics manuals by other brands

rozum robotics
rozum robotics Pulse Operator's manual

ROKAE
ROKAE xMate CR18 Hardware installation manual

dji
dji Robomaster S1 Disclaimer and safety guidelines

Syntec
Syntec LA2000-8 product manual

Mitsubishi Electric
Mitsubishi Electric MELFA RH-3CRH Series instruction manual

ICHIBOT
ICHIBOT LF ULTIMATE 4S user guide