Other Operaon
a. External & Internal Temperature Check:
Long press the ‘ ’ and ‘ ’ to switch the internal temperature
or the external temperature.
b. Temperature Protecon Warning:
When the temperature is higher or lower than the protecon
value, ‘ ’will flash, the valve will autoclose or open, and
adjust the temperature to2℃lower or 2℃higher than the
protecon value, ‘ ’ will stop flash and the protecon mode
cancelled.
c. ERR Excepon :
d. There have the Valve An-lock Funcon.
When the ‘ ’ light up, it means the sensor mode was wrong or
the sensor was broken. And the temperature value in the screen
will show ‘ -- ’ .
Advanced Sengs
1Sensor type
00: Internal 01: External 02: Internal & External. Default is 00
2High temperature protecon:
20~90℃, Default is 28℃, ‘ -- ’ Cancel the protecon
3Low temperature protecon :
0~15℃, Default is 5℃, ‘ -- ’ Cancel the protecon
4
5
6
7
8
9
10
11
12
Swing: 1-9 ℃,Default 2 ℃
Temperature calibraon :-9℃~+9℃, Default is 0℃
35~90℃, Default is 35℃Highest target temperature:
Lowest target temperature: 0~30 ℃, Default is 5℃
Home mode target temperature: Default is 22℃
Away mode target temperature: Default is 15℃
System restart:
Press ‘ ’ or ‘ ’ to switch the ‘ -- ’ to ‘ == ’ and wait for 5s
Press ‘ ’ or ‘ ’ to switch the ‘ -- ’ to ‘ == ’ and wait for 5s
Factory seng:
AUTO mode target temperature: Default is 20℃
When the thermostat is power on, long press the ‘ ’ and ‘ ’
(5s),
press ‘ ’ select the seng items, and press ‘ ’ or ‘ ’ to select.
09