Ionic Pro CA200 User manual

CA200
Owner’
s
Manual

TABLE OF CONTENTS
PRODUCT BENEFITS 1
SAFETY INSTRUCTIONS 1
IMPORTANT WARNINGS 3
Main Parts 3
OPERATING THE IONIC PRO®COMPACT IONIC AIR PURIFIER 5
Getting Ready 5
Controls/Settings 6
Operation 7
CLEANING & MAINTENANCE 8
To Clean the Collection Blades 9
To Clean the Internal Ionizing Wires 10
Cleaning External Surfaces 11
DEEP CLEANING 11
TROUBLE-SHOOTING 12
MORE THINGS YOU SHOULD KNOW 13
Ozone and Your Health 13
ORDERING IONIC PRO® IONIC AIR PURIFIERS 13
ORDERING EXTRA COLLECTION BLADES 13
WARRANTY 14
ARBITRATION AGREEMENT 15
Thank you for purchasing
the Ionic Pro® Compact and
congratulations on taking this
important step in improving
the quality of air in your home,
office and other environments.
Customer satisfaction is our
number one goal. Your Ionic
Pro® Compact is a premium air
purifying appliance which comes
with a limited one-year warranty.
Enjoy your Ionic Pro® Compact
and visit our website for
more exciting quality products
and upgrades.
envionproducts.com

1
CA200
2
CA200
SAFETY INSTRUCTIONS
IONIC PRO®COMPACTIONIC AIR PURIFIER PRODUCT BENEFITS
Your Ionic Pro® Compact ionic air purier delivers all these wonderful benets:
> Totally silent
> No filters to replace
> Easy to use
> Easy to clean
> Energy-efficient
Breathe even easier when you order additional Ionic Pro® Air Purier products today to
enjoy fresh and puried air in every room of your home everyday. See our “Ordering Ionic
Pro® Air Puriers” section in this owner’s guide for details (Pg 13).
SAFETY INSTRUCTIONS
EXTREMELY IMPORTANT INFORMATION:
Safety precautions should always be used when operating this or any electrical appliance.
Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the
warnings below:
Use only as described in this Ionic Pro® Compact ionic air purifier owner’s manual.
To reduce the risk of electric shock, do not attempt to service the product in any way other than in
the manner described in the “CLEANING & MAINTENANCE” section of this owner’s manual.
Do not use the Ionic Pro® Compact ionic air purifier outdoors.
Do not use the Ionic Pro® Compact ionic air purifier in bathrooms or other humid environments,
near fireplaces or in areas where flammable or combustible vapors or products may exist.
The Ionic Pro® Compact ionic air purifier operates at 120v AC and 60Hz only.
To reduce the risk of electric shock, this product has a grounding-type plug that has a third
grounding pin. This plug will fit only into a grounding-type power outlet. If the plug does not fit
into the outlet, contact qualified service personnel to install the proper outlet. Do not alter the
plug in any way.
Always turn off all controls before unplugging the Ionic Pro® Compact ionic air purifier from outlet.
Always turn off and unplug this product from outlet before cleaning the collection blades.
Always turn this product off when not in use.
Never touch the internal collection blades, electrodes, ionizing wires, or any part of the Ionic Pro®
Compact ionic air purifier with any object capable of conducting electricity.
PRODUCT BENEFITS
Do not open the door of the Ionic Pro® Compact air purifier when it is in operation.
Attempting to dissemble the unit may cause serious personal injury to the user and/or result
in considerable damage to the unit.
Do not place the Ionic Pro® Compact ionic air purifier’s cord near a heated surface.
Never operate the Ionic Pro® Compact ionic air purifier if the plug or cord is damaged or appears
damaged. Only qualified service personnel should ever replace or attempt to replace a damaged
power cord.
Never use the power cord to pick up, carry, drag, pull, or lift the Ionic Pro® Compact ionic air purifier.
Do not pull the cord against or around sharp corners and edges. This could result in injury to the user
or damage to the cord and is prohibited.
Always remove the plug from its power outlet by holding onto the plug itself and pulling gently.
Never pull on the cord itself to unplug it from its power outlet.
Use care when operating the Ionic Pro® Compact ionic air purifier by keeping all fingers, body parts,
hair, loose clothing and jewelry away from openings.
Never touch the Ionic Pro® Compact ionic air purifier or its plug when your hands are wet.
Never try to insert any object into the body of the Ionic
Pro® Compact ionic air purifier when it is in operation.
The Ionic Pro® Compact ionic air purifier is an
electrical appliance. Adult supervision is required
when operating the Ionic Pro® Compact ionic air
purifier in the presence of children.
Do not touch the metal blades until after discharging
residual electricity by touching blades to an electrical
ground such as a water pipe or metal faucet.
The collection blades and ionizing wires should be
inspected frequently and cleaned regularly to prevent
excessive accumulation that may result in an electrical
flashover or a risk of fire.
This product complies with the maximum allowable
concentration of ozone of 0.050 parts per million by
volume (ppmv) in a 24-hour period. The Health Canada
Guideline 2010 recommends that the maximum
exposure limit, based on an averaging time of 8
hours, is 0.020 ppmv or less when tested in a sealed,
controlled room approximately 30 m3.

3
CA200
4
CA200
IMPORTANT WARNINGS IMPORTANT WARNINGS
If the product is still making excessive
noise after cleaning and thoroughly drying
the collection blades and re-inserting
them as described in the “CLEANING &
MAINTENANCE” section of this manual,
turn off and unplug the unit. After you
have turned off and unplugged the
unit, see Diagram B or F for the location
of the Wire Cleaning Mechanism. Lift
and lower the Wire Cleaning Mechanism
three to four times to thoroughly clean
the internal ionizing wires (see Diagram
Hin the “CLEANING & MAINTENANCE”
section). This movement helps to scrape
free particles from the internal ionizing
wires. To keep your Ionic Pro® Compact
ionic air purifier working properly, it will
be necessary to clean the collection blades
after every month of use and the internal
ionizing wires after every two weeks of use
(see “CLEANING & MAINTENANCE” and
“DEEP CLEANING” section of this manual
for the proper techniques).
WARNING: After cleaning the
collection blades (see “CLEANING &
MAINTENANCE” section) with soap and
water, allow at least 24 hours for the
collection blades to dry thoroughly
before inserting them back into the unit.
Water can easily get trapped along the
collection blades’ many surfaces and
edges and damage could result if there
is any moisture on the collection blades.
You will need to clean your Ionic Pro®
Compact ionic air purier more often if it
has been exposed to heavy pollution.
MAIN PARTS
A. Collection Blades
B. Operating Panel
C. Outer Case Housing
D. AC Cord
E. Base
F. Wire Cleaning Mechanism
G. Removable Cap
IMPORTANT WARNINGS
Before using your Ionic Pro® Turbo air purifier,
please read all safety instructions and the following
important information.
Collection Blades
Please look at the “Main Parts” diagram and locate
the part labeled “A”.
These are the collection blades and are a vital part
of this amazing ionic air purifying system. The
collection blades are where unhealthy pollutants,
allergens, irritants and odors are trapped when the
Ionic Pro® Turbo Ionic Air Purifier air purifier is in
proper working condition and in use.
READ THIS: The metal collection blades may
contain a static charge. Do not touch the
metal collection blades, even when you take
the collection blade unit out for cleaning.
(See “CLEANING & MAINTENANCE” section
of this manual.)
The Ionic Pro® Compact ionic air purifier is designed
to run quietly and requires very little time and
effort to maintain in proper working condition. If
you hear excessive noise or static coming from your
Ionic Pro® Compact ionic air purifier, it generally
indicates that the product needs to be cleaned.
Turn off your Ionic Pro® Compact ionic air purifier,
unplug the cord and carefully follow the cleaning
instructions in the “CLEANING & MAINTENANCE”
section of this manual.
Do not place Ionic Pro® Compact ionic air purifier near a fireplace. Even if a fireplace is not in use,
chimney dust and soot may circulate through the Ionic Pro® Compact ionic air purifier and then
re-circulate and leave a residue on the unit and surrounding areas. We recommend not placing
the Ionic Pro® Compact ionic air purifier anywhere near candles or oil lamps. If you intend to use
candles or oil lamps near the Ionic Pro® Compact ionic air purifier despite this warning, make
sure that the wicks are cut to no more than a quarter inch to cut down on smoke production.
A.
Collection
Blades’
Handle
Wire Cleaning
Mechanism
Removable
Cap
B.
C.
D. E.
F.
G.

5
CA200
6
CA200
OPERATING THE IONIC PRO® COMPACT
IONIC AIR PURIFIER
OPERATING THE IONIC PRO® COMPACT
IONIC AIR PURIFIER
Getting Ready
Locate a level surface on which to place your Ionic Pro® Compact ionic air purifier and a grounded
120v outlet (follow warnings described in the “SAFETY INSTRUCTIONS” section of this manual).
Position your Ionic Pro® Compact ionic air purifier at least one foot (12 inches) from the wall.
Plug in the unit. You are now ready to turn on your Ionic Pro® Compact ionic air purifier!
Controls/Settings
1. ON/OFF Button – Turns unit on and off.
2. Lo (low output indiciation light) – At this setting, the unit will cycle ON and OFF.
It will cycle ON for approximately 25 seconds, and then rest for 25 seconds. This cycling
will continue as long as the unit is in Lo mode.
3. Hi (high output indiciation light) – At this setting, the unit stays ON continuously.
4. Clean (clean indiciation light) – This red light goes on when your Ionic Pro® Compact
ionic air purifier needs to be cleaned, or the unit is experiencing some other problem.
See the “CLEANING & MAINTENANCE” and “TROUBLE-SHOOTING” sections.
5. Wire Cleaning Mechanism – This is used to clean the internal ionizing wires.
See “CLEANING & MAINTENANCE” for full details.
6. Removable Cap – Lift off the Removable Cap to locate collection
blades for cleaning (as described in “CLEANING & MAINTENANCE” section).
1. ON/OFF
Button
2. Low
Output
Indictaion
Light
3. High
Output
Indication
Light
4. Clean
Indictaion
Light
5. Wire
Cleaning
Mechanism
6. Removable
Cap

7
CA200
8
CA200
Operation
Set up the Ionic Pro® Compact ionic air purifier as described in “Getting Ready”. Press the
ON/OFF button to activate your ionic air purifier and get ready to enjoy clean, ionized air that
cycles through pre-programmed run/rest intervals according to the setting you select.
The Ionic Pro® Compact ionic air purifier automatically defaults to the Hi (high/maximum
output) setting whenever the unit is turned on.
Press the ON/OFF button one more time to select the Lo (low) output setting to enjoy
intermittent run/rest periods.
Press the ON/OFF button a third time to turn the unit off.
The indicator LEDs light up to indicate your current setting (Lo, Hi).
Clean Light:
The red CLEAN light will turn on and the unit
will shut down if cleaning is overdue.
The Ionic Pro® Compact ionic air purifier’s
collection blades must be cleaned after
month of use and the internal ionizing wires
must be cleaned after every two weeks of
use (see “CLEANING & MAINTENANCE” for
full directions). Once the collection blades
are properly cleaned, thoroughly dried and
re-inserted into your Ionic Pro® Compact ionic
air purifier and the internal ionizing wires are
properly cleaned, normal operations should
continue. If not, see “DEEP CLEANING” and
“TROUBLE-SHOOTING”.
CLEANING & MAINTENANCE
With very little effort, the Ionic Pro® Compact
ionic air purifier delivers cleaner, fresher,
healthier air to your indoor environments.
Keep your Ionic Pro® Compact ionic air
purifier functioning properly by cleaning
the collection blades after every month of
use as recommended. The internal ionizing
wires are an important part of the Ionic
Pro® air purifying system and need to be
cleaned after every two weeks of use or if
your unit starts to make a buzzing noise (see
“TO CLEAN IONIZING WIRES” and “DEEP
CLEANING”sections).
More frequent cleaning is often required if
your Ionic Pro® Compact ionic air purifier is
new or if you place it in a different location.
Exposing your Ionic Pro® Compact ionic air
purifier to candle/oil lamp/fireplace soot
and smoke is not recommended and will
require the collection blades to be cleaned
after every exposure (see “IMPORTANT
WARNINGS”).
OPERATING THE IONIC PRO® COMPACT
IONIC AIR PURIFIER
Removable
Cap
Collection
Blades
Unit

9
CA200
10
CA200
Helpful Tips: Remember to clean your Ionic
Pro® Compact ionic air purier every month and
any time the red CLEAN /FAULT light comes on
or whenever you hear your unit begin to make
excessive noise.
To Clean the Collection Blades
Turn off and unplug your Ionic Pro® Compact air
purifier. Let the unit rest a minute.
Next, lift off the removable cap and pull up on the
collection blades’ handle to slide the collection
blades out of the top of your Ionic Pro® ionic air
purifier.
Do not touch the metal blades until after discharging
residual electricity by touching blades to an electrical
ground such as a water pipe or metal faucet. Wipe
away the trapped particles collected on the three
blades with a slightly damp sponge or cloth. If you
use a slightly damp cloth to clean the blades, it is
possible the collection blades will be completely dry
within two to three hours. Always allow the collection
blades to dry thoroughly before resuming use.
IMPORTANT: To avoid damaging your Ionic
Pro® Compact ionic air purier, make sure the
collection blades are completely dry and free of
all moisture and that your Ionic Pro® Compact
ionic air purier is turned o and unplugged
before attempting to re-insert the collection
blades.
If you have used soap and water to clean the
collection blades, wait at least 24 hours to ensure that
they are thoroughly dry before re-inserting them into
your Ionic Pro® Compact ionic air purifier.
To Clean the Ionizing Wires
The internal ionizing wires need to be cleaned
after every two weeks of use. There is a Wire
Cleaning Mechanism used to clean the
internal ionizing wires which you slide up
and down to scrape off particle residue, (see
Diagram B of the Operating Panel to locate the
Wire Cleaning Mechanism). Lift and lower the
Wire Cleaning Mechanism three or four times
to thoroughly clean the ionizing wires (see
Diagram H).
REMEMBER TO ALWAYS RETURN THE WIRE
CLEANING MECHANISM TO ITS ORIGINAL
POSITION BEFORE ATTEMPTING TO RESUME
USE OR THE UNIT WILL NOT FUNCTION.
CLEANING & MAINTENANCE CLEANING & MAINTENANCE
H.
Cleaning the
Ionizing Wires
Collection Blades

11
CA200
12
CA200
TROUBLE-SHOOTING
DEEP CLEANING
Noisy functioning (audible loud buzzing sound) is a sign that
your Ionic Pro® Compact ionic air purifier is overdue for a complete
clean-up of the collection blades and the internal ionizing wires.
The internal ionizing wires must be kept clean to ensure silent
and normal operation.
To Deep Clean:
1. Before beginning, make sure you have read all of the safety
precautions and cleaning instructions located in the “SAFETY
INSTRUCTION”, “IMPORTANT WARNINGS”, and “CLEANING
& MAINTENANCE” sections of this owner’s manual.
2. First, turn OFF and unplug your Ionic Pro® Compact ionic
air purifier.
3. Let it rest for a minute before removing the collection blades
as described in the “To Clean the Collection Blades” section of
this manual.
4. Use a cloth and warm, sudsy water to wipe away dirt particles
on the blades’ surfaces and edges.
5. Rinse and let the blades dry thoroughly for 24 hours before
re-inserting them into your Ionic Pro® Compact ionic air purifier.
If desired, you can purchase a second set of collection blades to
use while the original blades are drying to allow for virtually
uninterrupted air purification. (See the “ORDERING EXTRA
COLLECTION BLADES” section of this owner’s manual for details.)
6. Clean the ionizing wires as described in the “To Clean the Ionizing
Wires” section of this manual.
Cleaning External Surfaces
Over time, some particles and dust may accumulate on the
external surfaces of your Ionic Pro® Compact ionic air purifier.
If this happens:
1. Turn off and unplug the unit.
2. Mix one ounce of soap or detergent with five ounces of water
and apply sparingly with a moist sponge to wipe the outer
case surfaces.
3. Do not allow any water to slip into the internal parts of the Ionic Pro®
Compact ionic air purifier as this could damage its functioning and
may result in injury to you.
4. Allow the unit to dry for at least 24 hours before resuming use.
CLEANING & MAINTENANCE
TROUBLE REASON TROUBLE-SHOOTING
Indication/Setting light
does not turn on.
Machine is unplugged.
ON/OFF button has not
been pressed.
Check if plug is loose.
Press the ON/OFF button.
Red CLEAN light is on or
the unit shuts down.
Too much dust has
accumulated.
AC input unstable or
overloaded.
Moisture on collection blades.
Red light may go on if the unit
just needs to be “reset”.
Turn off, unplug & lift the lever
to the wire cleaning mechanism
to clean the ionizing wires.
Turn off, allow unit to rest
a while to return to normal.
Temperature & moisture level
and then turn on again.
Press “ON” button to reset.
Excessive noise
generated.
Collection blades are not
installed properly.
Too much dust has
accumulated.
Internal parts are wet.
Remove & replace collection
blades & press “On” button.
Clean and dry blades and
ionizing wires thoroughly.*
Keep the machine dry.
Collection blades
do not go back in.
Improper orientation. Reverse blade orientation.
Indication light
does not go on.
Collection blades are not
completely inserted
Wire Cleaning Mechanism is
not completely inserted.
Check to see that the blades are
completely seated in housing
Check to see that Wire Cleaning
Mechanism is completely seated
in housing.
*See “CLEANING & MAINTENANCE” section.
Ozone and Your Health
After you activate your Ionic Pro® Compact ionic air purifier, you may notice a new clean scent.

13
CA200
14
CA200
MORE THINGS YOU SHOULD KNOW ONE YEAR LIMITED WARRANTY
One Year limited Warranty
Your Ionic Pro® Compact ionic air purifier is warranted to be free from defects in materials and
workmanship for one year from the original purchase date. Should the product have a defect
in materials or workmanship, we will repair or replace it without charge to you (a shipping and
processing fee will apply). To obtain service under warranty, simply call our customer service center
toll-free at 1.800.875.8577.
This warranty does not cover damage caused by accident, misuse or any use other than as intended
and described in this product manual, or damage resulting from failure to maintain and clean this
product as specified in this product manual. This warranty applies only to the original purchaser of
the Ionic Pro® Compact ionic air purifier.
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT, INCLUDING IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED
IN DURATION TO THE WARRANTY PERIOD, AND NO WARRANTIES, WHETHER EXPRESS OR
IMPLIED WILL APPLY AFTER THIS PERIOD.
Some states do not allow limitations on the duration of implied warranties, so the above limitation
may not apply to you. While this warranty gives you specific legal rights, you may also have other
rights which may vary from state to state.
Contact Info for Warranty Service:
Ionic Pro® by Envion®
P.O. Box 9169 | Van Nuys, CA | 91409-8291
1.800.875.8577 | envionproducts.com
Ionic Pro Compact
©2018 Envion, LLC. All Rights Reserved.
U.S. Patent Nos. D495,042; D505,488; D522,116; 6,855,190; 6,946,103; and 6,977,008.
Chinese Patent No. ZL03353322.9; ZL200420006826.0; ZL200420077199.X, and ZL200620004930.5.
Hong Kong Patent Nos. HK1063973; HK1066437; and HK1082896.
Important Information For Your Health.
The Ionic Pro® Compact ionic air purifying system utilizes an ionizing process which results in very
low ozone emission. The Ionic Pro® Compact air purifier complies with U.S. safety requirements for
low ozone emission (less than 50 parts per billion) and meets the UL867 standard for consumer
products. UL867 is the U.L. standard for safety for electrostatic air cleaners.
Individuals with a history of respiratory disease, asthma, heart disease, lung disease,
breathing problems or concerns about ozone should ask their doctor whether the
concentrations of ozone generated by this or other commercial ionic air puriers are
appropriate for their specic health needs.
ORDERING IONIC PRO®IONIC AIR PURIFIERS
There’s no such thing as too much clean air. Breathe even easier when you order additional
Ionic Pro® air purier products today to enjoy fresh and puried air in every room of your
home every day. Visit our website at envionproducts.com or call 1.800.875.8577 to order your
new Ionic Pro® air purifiers today and to find out about our entire line of exciting products.
ORDERING EXTRA COLLECTION BLADES
Enjoy virtually uninterrupted air purification by ordering an extra set of collection blades today.
This is a great way to make sure you can always have a clean and thoroughly dry set of collection
blades available to insert into your Ionic Pro® Compact ionic air purifier whenever the other
blades are being cleaned and dried for 24 hours. Visit our website at envionproducts.com or call
1.800.875.8577 to order your new collection blades today.

15
CA200
16
CA200
ARBITRATION AGREEMENT
PLEASE READ THIS AGREEMENT CAREFULLY. YOU ACCEPT THE TERMS OF THIS AGREEMENT BY RETAINING
THE PRODUCT(S) SHIPPED IN CONNECTION WITH THIS AGREEMENT (THE “PRODUCTS”) FOR MORE THAN
THIRTY (30) DAYS AFTER RECEIPT. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, YOU MAY
RETURN THE PRODUCT TO COMPANY WITHIN THIRTY (30) DAYS OF RECEIPT FOR A FULL REFUND.
THIS ARBITRATION AGREEMENT (“AGREEMENT”) AFFECTS YOUR LEGAL RIGHTS AND REMEDIES BY
PROVIDING THAT DISPUTES BETWEEN YOU AND THE MANUFACTURER, DISTRIBUTOR AND/OR SELLER
OF THIS PRODUCT (COLLECTIVELY, “COMPANY”), MUST BE RESOLVED THROUGH BINDING ARBITRATION
AND NOT IN COURT. IT ALSO PROVIDES THAT ANY DISPUTE CANNOT BE RESOLVED IN A CLASS ACTION
OR OTHER PROCEEDING WHERE YOU REPRESENT OTHER PERSONS OR OTHER PERSONS REPRESENT YOU,
AND THAT NO CLASS OR REPRESENTATIVE ARBITRATIONS ARE PERMITTED. PLEASE CAREFULLY READ ALL
TERMS IN THIS AGREEMENT.
1. RESOLUTION OF CLAIMS OR DISPUTES.
Any claim or dispute between you and Company (or any of Company’s subsidiaries or affiliates) arising out of or
relating in any way to the Product or this Agreement shall be resolved through final, binding arbitration. This
arbitration obligation is reciprocally binding on both you and the Company and applies regardless of whether
the claim or dispute involves a tort, fraud, misrepresentation, product liability, negligence, violation of a statute,
or any other legal theory. Both you and Company specifically acknowledge and agree that you waive your right
to bring a lawsuit based on such claims or disputes and to have such lawsuit resolved by a judge or jury.
2. LIMITATION OF LEGAL REMEDIES.
All arbitrations under this Agreement shall be conducted on an individual (and not a class-wide) basis, and an
arbitrator shall have no authority to award class-wide relief. You acknowledge and agree that this Agreement
specifically prohibits you and the Company from commencing arbitration proceedings as a representative of
others or joining in any arbitration proceedings brought by any other person. The parties agree that no class or
representative actions of any type are permitted.
3. ARBITRATION PROCEDURES.
a.Before instituting an arbitration, if you have any dispute, we strongly encourage you to contact the Company
to try to resolve the matter by calling 800.218.3560, although you are not required to do so.
b.The arbitration of any claim or dispute under this Agreement shall be conducted in accordance with the
expedited procedures set forth in the JAMS Comprehensive Arbitration Rules and Procedures as those
Rules exist on the date you receive the Product, including Rules 16.1 and 16.2 of those Rules. These rules and
procedures are available by calling JAMS or by visiting its web site at www.jamsadr.com. The arbitration of
any claim or dispute under this Agreement shall be conducted by an arbitrator who has at least five years of
experience conducting arbitrations.
c. The arbitration of any claim or dispute under this Agreement shall be conducted in the State of California or
the location in which you received this Agreement. For claims of $10,000 or less, you may choose whether the
arbitration proceeds in person, by telephone, or based only on submissions.
d. The Company shall pay costs for the arbitration of claims, including any JAMS Case Management Fee and all
professional fees for the arbitrator’s services. The Company shall pay the fees and costs of its own counsel,
experts and witnesses and shall not be able to recoup them from you even if you do not prevail in the
arbitration. Unless otherwise provided by law, you acknowledge and agree that you shall pay the fees and costs
of your own counsel, experts and witnesses.
4. CHOICE OF LAW.
The arbitration provisions of this Agreement and any arbitration conducted pursuant to the terms of this
Agreement shall be governed by the Federal Arbitration Act (9 U.S.C. Secs. 1-16). In this respect, the parties
acknowledge that this Agreement involves a transaction conducted in interstate commerce. Otherwise, this
Agreement and the rights of the parties hereunder shall be governed by and construed in accordance with
the laws of the State of California, exclusive of conflict or choice of law rules.
5. SEVERABI LITY.
If any provision of this Agreement is declared or found to be unlawful, unenforceable or void, such provision
will be ineffective only to the extent that it is found unlawful, unenforceable or void, and the remainder of the
provision and all other provisions shall remain fully enforceable.

CA200 / 102418 / R1
CA200
Table of contents
Other Ionic Pro Air Cleaner manuals

Ionic Pro
Ionic Pro IPMIN052208 User manual

Ionic Pro
Ionic Pro Turbo TA500 User manual

Ionic Pro
Ionic Pro CA500 User manual

Ionic Pro
Ionic Pro TURBO User manual

Ionic Pro
Ionic Pro TP101M User manual

Ionic Pro
Ionic Pro CA500 User manual

Ionic Pro
Ionic Pro TA750 User manual

Ionic Pro
Ionic Pro ELITE TA740 User manual