IOT-Smart Solutions MPTZ20XIRIP-HLC Instruction Manual

MPTZ20XIRIP-HLC
Network HD IR High Speed Dome Camera
Manual operation
V1.0
http://iotsmartsolutions.net

I. SAFETY PRECAUTIONS
CAUTION
RISK OF ELECTRIC
SHOCK. DO NOT OPEN!
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO DOT
OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
The lighting flash with a arrowhead symbol, in an
equilateral triangle, is intended to alert the user.
There is uninsulated “dangerous voltage” presence
near by the product's enclosure which may be risk of
to persons .
The exclamation point within an equilateral
triangle is intended to alert the user to reference
of the imp ortant operatin g and maintenance
(servicing ) instructions .
THE PRODUCT CODE MARKED ON THE BOTTOM COVER. PLEASE
FILL THE CODE IN THE FOLLOWING BLANK. PLEASE SAVING
THIS SPECIFICATION CAREFULLY, SO THAT CHECKING.
MODEL:________________________
PRODUCT CODE:________________________
Please read the operation manual
carefully before installing and using this product

Index
I. Important Safeguards………………………………………………………………… 1
II. Description of Functions……………………………………………………………1
III. Setup of Dome Camera…………………………………………………………… 2
1. Connection of the System……………………………………………………… 2
2. Setup of Coding Switch of Dome Camera…………………………………3
3.Setup of the Protocol and the Default Baud Rate…………………………4
4.Setup of the Baud Rate of Communication…………………………………4
5.Selection of the Terminal Resistor of the Dome Camera………………4
IV. Description of airlines seat outlet………………………………………………4
V. Installing ways …………………………………………………………………………5
VI. System control wires as figure shows…………………………………………7
VII. To Ensure a Smooth and Successful Installation…………………………7
VIII.Technical data table…………………………………………………………………7
IX.Troubleshooting ………………………………………………………………………10
Appendix Ⅲ: RS485 Bus Basic Knowledge………………………………………12

--
1
I. Important Safeguards
1. All the safety and operating instructions should be read before the units is operated.
2.Power supply for IR Dome Camera:DC12V. The power input power supply indicated on the
base of dome or other related marking label.
3.During the course of transportation, storage and installation, the product should be avoided
from incorrect operations such as heavy pressing, strong vibration etc, which can cause
damage of product as there are sophisticated optical and electronic devices inside the machine.
4. Do not attempt to disassemble the camera. In order to prevent electric shock, do not remove
screws or covers. There are no user-serviceable parts inside.
5. Always follow all electrical standards for safety when it is in operation.Adopt the particular
power supply which is provided with the unit. RS-485 and video signal should keep enough
distance with high voltage equipments and cables when they are in transmission. Precautions
for anti-lightning and anti-surging should be taken if necessary.
6. Do not operate it in case temperature, humidity and power supply are beyond the limited
stipulations.
7. Do not let the camera aim at the sun or the object with extreme light whatsoever it is
switched on or not. Do not let the camera aim at or monitor bright and standstill object for a
long time.
8. Do not use aggressive detergent to clean the main body of the camera. Wipe dirt with dry
cloth. If needed, mild detergent can be used suitably.
9. Operate the intelligent speed dome camera with great care to avoid shock or vibration. It
operate incorrectly, the Speed Dome could be damaged.
10. Please ensure the installation position with enough endurance when you install the
intelligent IR High speed dome camera.
11. If necessary, use a commercial lens cleaning paper to clear the lens windows. Gentlywipe
the lens window until clean.
II. Description of Functions
This Infra Red High Speed dome Camera uses the highly integrated 16-bit processor, low
power consumption, super stable. Built-in high-power infrared array light inside, ultra-high
luminous efficiency, fill light uniform, smaller heat and night vision range up to 80 meters.
1. Integrated Speed-Variable PAN/TILT
a. Turning 360ºh orizontally and continuously with unlimited positions and an adjustable
speed from 0.01 - 300 º/s; turning 0 - 90ºvertically with a speed up to 120 º/s.

--
2
b. Running stably at low speed with super lower noise. Pictures have no shaking.
c. Automatic 180ºflip and panoramic monitoring without blind point, the location
precision up to ±0.1°.
2. High Intelligent Degree
a. As much as 255preset positions can be preset with powerless memory.
b. The camera can scan horizontally between two points and scan speed can be modified.
The positions of linear scan are optional and the dome camera can scan the range
larger or smaller than 180°between any two points with adjustable speed;
c. Proportional pan function. The speed dome will depend on the amount of zoom. At
telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of
joystick deflection than at wide zoom settings. This keeps the image from moving too
fast on the monitor when there is a large amount of zoom. This slowing does not
happen when going to a preset, but does occur in turbo mode when high zoom is
selected. The minimum pan and tilt speeds are 0.1 degree per second at full zoom.
d. The Integrated Protocol-D. Communication protocols are integrated inside the dome
camera with selectable baud rate from 2400 bps to 19200 bps.
III. Setup of Dome Camera
1. Connection of the system
1) Address/Protocol Code
Before installing, please ensure the control communications and baud rates of the dome systems, then setup
the dome SW2 code as the same as the system,SW1 is used to set address of the dome camera,
SW2 is used to set the protocol of communication and the baud rate used by the dome camera.
And the code switch as Figure 1 shows.

--
3
SW1 SW2
Address selecting Protocol selecting
Figure 1
2. Setup of Coding Switch of Dome Camera. As figure 1 shows,J6(SW1) is used to set
dome address,address of dome camera from 1~1023.The coding switches from DIP-10
to DIP-1 are equivalent to a 10-bit binary digital. DIP-10 is MSB while DIP-1 is LSB.
The state “ON” of each bit means 1 while “OFF” means 0. Following table shows the
States of Coding Switches.
Dome
Address
States of Coding Switches
DIP-1
DIP-2
DIP-3
DIP-4
DIP-5
DIP-6
DIP-7
DIP-8
DIP-9
DIP-10
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
10
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
11
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
12
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
13
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
14
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
15
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
16
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
17
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
18
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
…
…
1023
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Table 1
For example:

--
4
Speed Dome Address=1
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=2
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=3
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=4
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=18
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=512
ON
1 2 3 4 5 6 7 8 9 10
3. Setup of the Protocol and the Default Baud Rate. As table 2 shows,J8 (SW2)is used to
set protocol and baud rate of dome camera. From DIP-4 to DIP-1of J8 is used to select
protocol,Please setup from DIP-1 to DIP-4 as OFF,it is PELCL-D.
Protocols Type
Selecting of protocol
Normal baud rate
DIP-1
DIP-2
DIP-3
DIP-4
DIP-5
DIP-6
PELCO-D
OFF
OFF
OFF
OFF
OFF
OFF
PELCO-P
OFF
ON
OFF
OFF
OFF
OFF
Table 2
4. Setup of the Baud Rate of Communication. As shown in Figure 2, J8 is used to set the
protocol of communication and the baud rate used by the dome camera. DIP-6 and DIP-5
of J8(SW2) are used to select the baud rate of communication and 4 different baud rates
can be selected in maximum. If the controller adopts non-standard baud rate, you can
adjust it to be identical with that of the main machine as per the following table.
Baud Rate of Communication
DIP-1
DIP-2
DIP-3
DIP-4
Setup of Baud Rate
DIP-5
DIP-6
2400 bps
OFF
OFF
4800 bps
ON
OFF
9600 bps
OFF
ON
19200 bps
ON
ON
5. Selection of the Terminal Resistor of the Dome Camera.
Please open the base of dome ,and there have 3-line jumper on base power control board,
this is the select switch of the 120 Ωterminal resistor on the bus RS485, on which only
one terminal resistor of the dome camera at the farthest end can be connected, while the
terminal resistors of other devices should be opened.
120 Ωterminal resistor is connected on RS485 Bus,if 3-line jumper connecting 1,2.
120 Ωterminal resistor is opened on RS485 Bus, if 3-line jumper connecting 2,3.
IV. Description of airlines seat outlet.

--
5
4.1 9-pin input socket cores descriptions:
1. Red DC12+ 2. GND with Video - 3. Yellow;RS485-
4. Orange:RS485+ 5.TX+ 6. Video +
7. TX- 8. RX+ 9. RX-
V. Installing ways
1. Dimension as figure 2 shows.
Figure 2
2. Car surveillance PTZ installing way:
2.1 Car vehicle shock absorber dimension as figure 3 shows.

--
6
Figure 3
3.Steps of installation
3.1 As Figure 4 shows, please remove the outer cover and take out it;
3.2 Please set the dome protocol and baud rate, also check the address of the dome.
3.3Please fix the outer cover, and ensure the tightness of waterproof seals.
3.4 Please fix the vehicle shock-absorb to the bottom basement of the dome, and fix the whole
dome.
3.5Please connect the air socket outline in accordance with the connection wire color of the
diagram correctly.
Figure 4

--
7
VI. System control wires as figure shows
VII. To Ensure a Smooth and Successful Installation, You Should:
1、Have electrical work to comply with latest national electrical code, national fire code,
and all applicable local codes and ordinances.
2、Coordinate with other trades to avoid interference.
3、Verify existing conditions on the site and coordinate with owner side to ensure
necessary utilities available.
4、Copy all related plans, specifications, shop drawings and attachments to schedule and
coordinate related work.
5、Thoroughly review the project to ensure that all jobs should meet or exceed the above requirements.
Contact with the CCTV Project Coordinator to draw attention in case alleged discrepancies occur.
VIII. Technical data table.
1、Main technical data table of high speed dome camera.
Power supply
DC12V 50/60Hz 2.5A
Power consumption
18W Heater:6W
Preset position
255
Zoom-rotation interaction
The dome will adjust the manual control speed automatically
according to the current zoom.
Auto overturning
The camera will rotate 180°automatically, when it reaches the
vertical position.
Pan scanning
360°programmable
Cruising track
8
Pan speed(Max)
300°/S
Pan running speed
0°-- 220°/S
Pan range
360°continuously
Tilt range
PTZ:-20—90° Dome:-95°-- 95°
Tilt speed(Max)
120°/S

--
8
Tilt running speed
0°-- 90°/S
Communication
RS485
Baud rate
2400/4800/9600/19200 bps
Fan / heater
Auto control
Infra Red distance
80m (2 groups Infrared light) / 200 m (1 group infrared lamp with
1W linkage laser light)
Relative humidity
10-75%(without agglomeration)
Work temperature
Outdoor:–45℃-- +60℃
Weight
2.5KG
2、Dome command
Operation Command
Operation
Operation
Display (SONY)
Preset NO 1 point
Preset + 1+ Enter
SET 001
CALL NO 1 point
Call + 1 + Enter
POS 001
Auto scan
Call + 141 + Enter
SCAN POS001~002
Counterclockwise 180 °horizontal rotation
Call + 33 + Enter
PAN 180
360°Auto scan (10°/s)
Call + 99 (149)+ Enter
SCAN 360
Set the start point of scan
Preset + 51+ Enter
SET START
Set the end point of scan
Preset + 52+ Enter
SET END
Auto scan start
Call + 51+ Enter
SCAN
Auto scan stop
Call + 52+ Enter
Cruise (From NO.1 to NO.16 )
Call + 53(76/97/151) + Enter
PATROL POS001~016
Cruise 2 (from NO.21 to No.32 )
Call + 152(98) + Enter
PATROL POS021~032
Dome Reset
Preset + 53+ Enter
SELF TEST
BLC ON
Call + 55(171)+ Enter
BLC ON
BLC OFF
Call + 170+ Enter /Preset+55+Enter
BLC OFF
D-ZOOM ON
Call + 58(231)+ Enter
DIGI ON
D-ZOOM OFF
Preset+58+Enter/ Call + 230+ Enter
DIGI OFF
AUTO Focus
Call + 59+ Enter
AUTO FOCUS
Manual Focus
Preset + 59+ Enter
MAN FOCUS
AUTO AE
Call + 60+ Enter
AUTO Exposure
Manual AE
Preset + 60+ Enter
MAN IRIS
WB AUTO
Call + 61+ Enter
AWB
WB Indoor
call + 62+enter
WB Outdoor
preset+62+enter
WB ATW
Preset + 61+ Enter
ATW
Level reverse ON
Call + 63+ Enter
Mirror ON
Level reverse OFF
Preset + 63+ Enter
Mirror OFF
Camera Display ON
Call + 57(192)+ Enter
OSD ON
Camera Display OFF
Preset+57+Enter/ Call + 191+ Enter
OSD OFF

--
9
ICR OFF Color Mode
Call + 67(179)+ Enter
IRCUT OFF
ICR ON B&W Mode
Preset+67+Enter/ Call + 178+ Enter
IRCUT ON
ICR AUTO Mode
call+56+enter
IRCUT AUTO
Fan ON
Call + 201+ Enter
FAN ON
Fan Auto (Fan Work 45°above)
Call + 202+ Enter
FAN AUTO
Adaptation Speed ON
Call + 210+ Enter
LIM ON
Adaptation Speed OFF
Call + 211+ Enter
LIM OFF
Power failure memory OFF
Call + 220+ Enter
PWR OFF
Power failure memory ON
Call + 221+ Enter
PWR ON
FLIP ON
Call + 248+ Enter
AFLIP ON
FLIP OFF
Preset + 248+ Enter
AFLIP OFF
AUTO HOME ON For Cruise (in 5 minutes)
Call + 90+ Enter
PARK ON
AUTO HOME OFF
Preset+90+Enter/ Call + 250+ENTER
PARK OFF
AUTO HOME ON For NO.1 (in 5 minutes)
Call + 251+ENTER
PARK POS1
AUTO HOME ON For SCAN (in 5 minutes)
Call + 252 +ENTER
PARK SCAN
AUTO HOME ON For Cruise (in 5 minutes)
Call + 253 +ENTER
PARKPATROL
Camera Reset
Preset + 54 + Enter /Call + 241 + Enter
RESET C
SYSTEM RESET
Call + 54 (240)+ Enter
RESET D
SHARP +
call+80+enter
Sharpness +
SHARP -
call+81+enter
Sharpness -
SHARP reset
call+82+enter
WDR ON
call+71+enter
WDR ON
WDR OFF
preset+71+enter
WDR OFF
Auto WDR
call+70+enter
SLOW Shutter ON
call+83+enter
SLOW Shutter OFF
preset+83+enter
3、Hikvision HD Camera Parameter:
Camera
HK 30x,2.0 Mega pixel camera module
Model
DS-2ZMD3007B
Image sensor
1/2.8" Progressive Scan CMOS
Zoom
30X Optical zoom
Focal length
4.5-135mm
Resolutions
50HZ:25fps(1920x1080) 60HZ:30fps(1920x1080)
50HZ:25fps(1280x720) 60HZ:30fps(1280x720)
Min.illumination
Color:
0.05Lux @ (F1.6,
AGC ON)Day&Night:
0.01Lux
@(F1.6,AGC ON)
S/N ratio
>52dB
Back light compensation
ON/OFF
WB、Iris、Focus
Auto/Manual
Day&Night model
ICR filter
Electronic shutter
1/1s ~ 1/30,000s
WDR
Support
3D Noise Reducing
Support

--
10
ONVIF
Support
PoE
NO
4、Hikvision HD Camera Parameter:
Camera
HK20x,2.0 Mega pixel camera module
Model
DS-2ZMD2007B
Image sensor
1/2.8" Progressive Scan CMOS
Zoom
20X Optical zoom
Focal length
4.7-94mm
Resolutions
50HZ:25fps(1920x1080) 60HZ:30fps(1920x1080)
50HZ:25fps(1280x720) 60HZ:30fps(1280x720)
Min.illumination
Color:
0.05Lux @ (F1.6,
AGC ON)Day&Night:
0.01Lux
@(F1.6,AGC ON)
S/N ratio
>52dB
Backlight compensation
ON/OFF
WB、Iris、Focus
Auto/Manual
Day&Night model
ICR filter
Electronic shutter
1/1s ~ 1/30,000s
WDR
Support
3D Noise Reducing
Support
ONVIF
Support
PoE
NO
IX、Troubleshooting
Problems
Possible Causes
Remedies
No action when power
is switched on
Power supply fault
Replace
Bad connection of the
power
Correct
Transformer damaged
Replace
Abnormal self-check.
Images with motor
noise
Mechanical failure
Repair
Camera inclined
Reinstall
Power supply not enough
Replace
Normal self-check but
no images
Video signal fault
Reinstall
Bad connection of the
video
Press to connect well
Camera damaged
Replace
Normal self-check but
out of control
RS485 bus bad connection
Check the RS485 connection
Dome ID setup is wrong
Reselect

--
11
Protocol setup is wrong
Reset and Switch ON again
Vague image
Bad connection of the
video
Press to connect well
Power supply not enough
Replace
Dome camera out of
control
Self check error
Switch ON again
Bad connection of control
wire
Replace
Bad control of dome
Switch ON again
Load much or
communication distance is
far
1. The farthest dome
terminal resistor away
from the control set to
“ON”status, the rest set
to “OFF”status.
2. Adding code distributor
Appendix Ⅰ: Lightning Proof and Surge Signal Proof
The product adopts TVS lightning proof technology to prevent from damage by lightning strike below 1500
W and impulse signals such as surge; but it is also necessary to abide by the following precautions to ensure
electrical safety based on practical circumstances:
Keep the communication cables at least 50 meters away from high voltage equipment or cables.
Make outdoor cable laying-out under eaves as possible as you can.
In open area shield cables in steel tube and conduct a single point ground to the tube. Trolley wire is
forbidden in such circumstances.
In strong thunderstorm or high faradic zone (such as high voltage transformer substation), extra strong
lightning proof equipment must be installed.
Take the building lightning proof requirements into account to design the lightning proof and
grounding of outdoor equipment and cable laying-out in accordance with the national and industrial
standards.
The system must be grounded with equal potentials. The earth ground connection must satisfy the
anti-interference and electrical safety requirements and must not short circuited with high voltage
electricity net. When the system is grounded separately, the resistance of down conductor should be
≤4Ωand the sectional area of down conductor should be ≤25mm2.

--
12
<Figure 5>
Appendix Ⅱ: The Cleaning of Clear Dome Cover
To obtain constant clear videos, user should clean the down cover periodically.
Be cautious when cleaning. Hold the down cover ring only to avoid direct touch to the acrylic down
cover. The acid sweat mark of fingerprint will corrode the coating of down cover and scratch on down
cover will cause vague images.
Use soft dry cloth or the substitute to clean the inner and outer surfaces.
For hard contamination, use neutral detergent. Any cleanser for high grade furniture is applicable.
Appendix Ⅲ: RS485 Bus Basic Knowledge
1. Characteristics of RS485 Bus
As specified by RS485 standards, RS485 Bus is of half-duplexed data transmission cables with
characteristic impedance as 120Ω. The maximum load capacity is 32 unit loads (including main
controller and controlled equipment).
2. Transmission distances of RS485 Bus
When user selects the 0.56mm (24AWG) twisted pair wires as data transmission cable, the maximum
theoretical transmitting distances are as follows:
Baud Rate
Maximum Transmitting Distance
2400 Bps
1800m
4800 Bps
1200m
9600Bps
800m
Table 3
If user selects thinner cables, or installs the dome in an environment with strong electromagnetic
interference, or connects lots of equipment to the RS485 Bus, the maximum transmitting distance will
be decreased. To increase the maximum transmitting distance, do the contrary.
3. Connection and termination resistor
The RS485 standards require a daisy-chain connection between the equipment. There must be
termination resistors with 120Ωimpedance at both ends of the connection (refer to Figure 6).

--
13
Please refer to Figure 7 for simple connection. “D” should not exceed 7m.
120Ω120Ω
1# 2# 3# 4# 32#
. . . . .
Figure 6
120Ω
1# 2# 3# 31#
120Ω
D
A+
B-
A+ B-
. . . . .
. . . . .
M ain controller
Figure 7
The connection of 120Ωtermination resistor: The termination resistor is ready on the Protocol PCB.
There are two kinds of connection. Refer to the Protocol PCB jumper setting form (refer to Picture 1).
1) In the Picture it is the factory default connection. The jumper is seated on Pin2&Pin3 and the
termination resistor is not connected.
2) when connecting the 120Ωtermination resistor, user should plug the jumper on Pin1&Pin2. and
the termination resistor is connected.
<Figure 8>
120Ω
120Ω
120Ω
1#
2#
16#
. . . .
MC2080
A+
B-
<Figure 9>
Table of contents