IPAS Power Block Series Service manual

Operating and mounting instructions
PowerBlock io64 Order number: 77024-180-03
BMA 77024-io64_Rev1_en 1/7
General usage
Po er Block series consists of 2 different actuator types. It can be installed in a standard distribution board.
 4TE DIN Rail casing modules for 8 outputs
 8TE DIN Rail casing modules for 16 outputs
A brief overvie of the functionality is given in the follo ing table:
evice type and accessories
At present the follo ing device types are available in the Po erBlock control group:
Product escription Order number:
Po er Block o8 8 capacitive outputs 77024-180-01
Po er Block o16 16 capacitive outputs 77024-180-02
Po er Block io64 4 capacitive outpus and 6 analog / digital inputs 77024-180-03
Scope of delivery
The follo ing individual components are included in the delivery of the Po erBlock device:
- Complete device ith connected bus connector
- Operating and mounting instructions
- Delivered in break-proof individual packaging
Application programs
The follo ing application programs are currently available for the Po erBlock device:
- 77014-Po erBlock io64-11-0110
Installation device
 Risk of death by electric shock.
 The device is intended for interior installation in dry rooms.
 The device must only be installed and commissioned by an accredited electrical engineer.
 Please follo country-specific safety and accident prevention rules as ell as all current KNX guide lines.
 Please follo country-specific rules and regulations for the planning and construction of installations, especially
ith regard to emergency lighting systems.
 For the installation the device must be s itched to zero potential.
 Do not open the device! Faulty devices must be returned to the manufacturer.
Outputs
BINARY ( POWER LEDs SUPPORTED) SHUTTER / BLIND
Bus failure Bus failure
Central ON/OFF Scenes
Counters Presets
Scenes Alarms
Timers Disable funktion
Alarms Manual control
Disable function
Manual control
ADVANCED FUNCTIONS
Analog & digital alarms Logic functions
Scene controller Advanced scene controller
Timers Setpoints
Over rite end user parameters Behavior at bus recovery
Operating and mounting instructions
PowerBlock io64 Order number: 77024-180-03
BMA 77024-io64_Rev1_en 2/7
Technical ata
POWER AN OUTPUTS SPECIFICATIONS
Power supply
Via KNX bus
Max. current consumption
21..30VDC
9,4mA
Additional supply No
Number of outputs 4 Dry contact (potential-free)
Output configuration Up to 4 outputs / Up to 2 channels
Output nominal values
AC rated current / voltage
DC rated current / voltage
16A / 250VAC 50/60Hz
C-Loads max. = 140 µF
16A / 30 VDC
evice nominal values
Current/Voltage 16A /250VAC per Output
Phases switching
distribution
1 independent phase allo ed per
output
Output life expectance Mechanical
Electrical
>
3

10

operations (at 60 times/min)
>
4

10

cycles ith resistive load at
max current
Connections KNX bus connection terminal
Terminal scre block
Tightening torque for terminal scre
0,8mm² solid
max. 6mm² Ø solid
maximum 0.5 Nm
Number of inputs Total inputs 6 binary/analog mixed inputs ith 2
common terminals
Art der Eingänge Binary/Analog Ready for:
- Dry contacts
- Standard movement detector ith
dry contact output
- Sensor temperature NTC
- Monitorized inputs ith end line
resistor
Scanning voltage 3,3V at common input
Input current 0,3mA per input
Protection
Short-circuit proof
Max cable length
40m for binary and analog inputs
Connections KNX bus connection terminal
Terminal scre block
Tightening torque for terminal scre
0,8mm² solid
max. 6mm² Ø solid
maximum 0.5 Nm
GENERAL SPECIFICATIONS
Control and display
elements
Programming button LED
8 x buttons for manual channels control
8 x LEDs
To assign the physical address
To s itch On/Off outputs and move
Up/Do n channels.
To display actual outputs/channels
status
Mechanical data
Casing:
Dimensions REG casing 4TE
Width:
Hight:
Length:
Weight:
Mounting:
Plastic
71 mm
58 mm
90 mm
185 g
35 mm DIN rail
Electrical safety
Protection type (in accordance ith EN60529):
KNX Bus:
IP20
Separated extra-lo voltage SELV
DC 24
Operating and mounting instructions
PowerBlock io64 Order number: 77024-180-03
BMA 77024-io64_Rev1_en 3/7
EMC requirements Complies ith:
Overvoltage category:
EN 50491-5-2 / EN 50491-5-3
class III
Environmental conditions
Clima conditions:
Operation temperature:
Storage temperature:
Rel. humidity (non condensing):
EN 60721-3-3 class 3k5
-5°C to +45°C
-25°C to +70°C
5 % to 93 %
Certification
CE-Signage
KNX registered
According to EMC-Guidelines
(Residential and commercial
buildings), Lo Voltage guidelines
Location and function of the LE s and control elements
Mounting and wiring
As an REG device, the Po er Block series are suitable for mounting in distribution boxes on 35 mm DIN rails and all
boxes.
5
4
6.2
6.1
2
1
3
8
72mm / 4 DIN RAIL
7.1
7.2
1: KNX bus connector
2: Programming button
3: Programming LED
4: SD card slot (only for internal use)
5: Outputs connector: Channel A,B
LED output/channel status
6.1: Binary channel: LED ON = Output ON, LED OFF=
Output OFF. Shutter: LED blinks hile moving DOWN
Blind chanal:
Long press: Move do n (LED blinks hile moving)
Short press: Stop / Step
Binary channel:
Short press: Output toggles ON/OFF
6.2: Binary channel: LED ON = Output ON, LED OFF =
Output OFF. Shutter: LED blinks hile moving UP
Blind chanal:
Long press: Move up (LED blinks hile moving)
Short press: Stop / Step
Binary channel:
Short press: Output toggles ON/OFF
7.1: Binary input LED ON = Contact closed, LED OFF =
Contact open
7.2: Binary input "Manual action"/"Input 1..3 OR Input
4…6 range status selector"
8: Inputs terminal block connector
Operating and mounting instructions
PowerBlock io64 Order number: 77024-180-03
BMA 77024-io64_Rev1_en 4/7
To mount the device, it must be angled to slide onto the DIN rail from above and then locked into place ith a do n ard
movement.
Please make sure that the security latch at the bottom side of the device snaps into place and that the device is firmly
attached to the rail. To dismount the device, the security latch can be pulled do n ards ith a suitable tool and then the
device can be removed from the rail.
After the device has been inserted, the cables for the Outputs should be attached to the upper and lo er connectors.
Ho ever, please make sure that these are labelled clearly.
The po er supply is connected to the bottom right-hand side connector according to the order indicated on the casing. To
connect the KNX cable, a standard bus connector is plugged into the respective entry on the device. Please make sure that
there is double basic insulation bet een the KNX installation and the po er supply. To do so, please insulate the ires of
the KNX cable up to the bus connector ith the enclosed shrinkable tubing.
Please make sure that the cables are laid in a ay that ensures sufficient distance bet een the inputs and outputs cables.
OUTPUT / INPUTS SCHEMATIC
Each channel can be configured to be used as 2 binary outputs or as one blind channel. Each output can be
po ered by an independent phase. Inputs can be configured to receive binary and analog signals (movement
detector, temperature sensor and monitored input).
Operating and mounting instructions
PowerBlock io64 Order number: 77024-180-03
BMA 77024-io64_Rev1_en 5/7
ANNEX 1: Manual Control
The
outputs
of the actuator have 2 push buttons and 2 status LEDs for each output channel on the front side.
Operating and mounting instructions
PowerBlock io64 Order number: 77024-180-03
BMA 77024-io64_Rev1_en 6/7
- These buttons can be activated to control each and every channel/output individually if you select "yes" in the
relevant parameter options in Binary outputs and/or Shutter/Blinds.
The LEDs represent:
For Binary outputs:
 The top ro : channels A1, A2, B1, B2
Für Shutter/Blinds:
 The top ro : channel’s first relay A1->UP, A2->DOWN, B1-UP, etc.
The inputs of the actuator have 1 push button and 1 status LED for each input on the belo LED ro
- These buttons can be activated to control each and every input individually if you select “yes” in the relevant
parameter options in Binary Input.
- The LEDs represent: The belo ro inputs 1&4, 2&5, 3&6 actual input status
MANUAL CONTROL – PARAMETER
The PARAMETER Mode allo s you to control all the channels of the actuator as configured in the ETS.
The Action simulates a telegram received at the s itching object of the selected channel.
Binary
Shutter/Blind
Press action: Sends Toggle ON/OFF command “0/1”
to the “S itching” object
LED = EIN (Anzeige Kanal-Status)
LED = AUS (Anzeige Kanal-Status)
Long press action (Channel output 1): Sends a UP
command “0” to the “Move” object.
Long press action (Channel output 2): Sends a DOWN
command “1” to the “Move” object.
Short press action (any output) ( hile shutter/blind is
moving) of same button: sends a Stop command to the
"Stop…" object.
LED blinks hile moving UP/DOWN during
parameterized time
Binäre Eingänge
Press action on 1&4, 2&5, 3&6: Sends Toggle ON/OFF command 0/1 to the "associated object" of the input (simulates
the close/open action on the binary contact)
LED = ON indicates input status -> Input contact closed)
LED = OFF (indicates channel status -> Input contact open)
"Man" push button in the right side for selection inputs status range bet een input 1..3 (LED = ON) and inputs 4..6
(LED = Blinking)
MANUAL CONTROL – TEST
Operating and mounting instructions
PowerBlock io64 Order number: 77024-180-03
BMA 77024-io64_Rev1_en 7/7
The Test Mode allo s you to test all the loads/ iring connected to the channels. It is independent from the ETS
configuration of the actuator (since the “Manual Control / Param mode + Test mode” is a default option, you can use
the Test mode even before programming the actuator).
Important note: Should a blind/shutter be connected to a channel, the 2 channels may never be closed at the same
time. Therefore, even in Test mode, if the channel is configured as a blind, this safety measure is implemented. For this
reason, it is better to first commission the OUTPUT: CHANNEL TYPE SELECTION before using the Test mode.
To change into the test mode, any button can be used depending of the channel configuration:
- If “Binary” channel is configured: Press any button for at least 500ms
- If “Blind” channel is configured: Press the t o buttons of any channel at the same time for at least 500ms
To change back to the normal “Parameter Mode” the same procedure should be repeated. Be a are by changing back
to “Parameter Mode” the device ill restart. Also after the device has restarted and if the channel is configured to be a
blind channel, it ill do a calibration movement on the first movement command.
In order to indicate that the actuator is in Manual Control / Test Mode, the LED of the selected channel is
continuously making a short blinking action every second; no matter hether the channel is ON (LED ON) or OFF (LED
OFF).
The Action s itches/moves the channel, as you can see in the table belo :
Binary
Shutter/Blind
Press action: Sends toggle ON/OFF command to the
relay (ON = Contact closed / OFF = Contact open)
LED = ON (indicates channel status)
LED = OFF (indicates channel status)
Rising edge press action (Channel X): Contact closed
Falling edge press action (Channel X): Contact open
LED = ON (indicates channel status)
LED = OFF (indicates channel status)

This manual suits for next models

2

Other IPAS Controllers manuals

IPAS Power Block Series Quick start guide

IPAS

IPAS Power Block Series Quick start guide

IPAS PowerBlock s4 DC Service manual

IPAS

IPAS PowerBlock s4 DC Service manual

IPAS Power Block Series Service manual

IPAS

IPAS Power Block Series Service manual

IPAS PowerBlock o16 Multi Service manual

IPAS

IPAS PowerBlock o16 Multi Service manual

Popular Controllers manuals by other brands

SmartAV Tango Series install guide

SmartAV

SmartAV Tango Series install guide

Pilz PNOZ mml1p operating manual

Pilz

Pilz PNOZ mml1p operating manual

Bosch BRC3100 Original operating instructions

Bosch

Bosch BRC3100 Original operating instructions

Störk-Tronic ST552G-XQ1TUR.109 manual

Störk-Tronic

Störk-Tronic ST552G-XQ1TUR.109 manual

Ingersoll-Rand ST400 Series Maintenance information

Ingersoll-Rand

Ingersoll-Rand ST400 Series Maintenance information

KELD EKT8 Series operating instructions

KELD

KELD EKT8 Series operating instructions

GE IC3645SR4W606MC2 Installation and operation manual

GE

GE IC3645SR4W606MC2 Installation and operation manual

maxon motor 4-Q-EC operating instructions

maxon motor

maxon motor 4-Q-EC operating instructions

Pedigree Technologies OneView ATG installation manual

Pedigree Technologies

Pedigree Technologies OneView ATG installation manual

ICP DAS USA TPD-280-H quick start guide

ICP DAS USA

ICP DAS USA TPD-280-H quick start guide

Omega CCT-80 Series user guide

Omega

Omega CCT-80 Series user guide

Hunter Hydrawise HCC-800-PL owner's manual

Hunter

Hunter Hydrawise HCC-800-PL owner's manual

SenseAir aSENSE mIII installation manual

SenseAir

SenseAir aSENSE mIII installation manual

Villeroy & Boch L200 installation instructions

Villeroy & Boch

Villeroy & Boch L200 installation instructions

Bosch rexroth SB11 Assembly instructions

Bosch

Bosch rexroth SB11 Assembly instructions

Elation eNODE 4 user manual

Elation

Elation eNODE 4 user manual

Keba ServoOne CM Series Operation manual

Keba

Keba ServoOne CM Series Operation manual

Central Boiler FireStar Operation manual

Central Boiler

Central Boiler FireStar Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.