Iron logic Z-595 EHT User manual

1. OVERVIEW
Z-595 EHT electronic lock is a reader for contactless keys with a controller powered by one 9V
PP3/E battery. One battery should suffice for 20,000 openings or 2.5 years in stand-by mode.
This lock has unique enclosure design and installation method, allowing it to be mounted on any
metal or wooden furniture, and get connected within 5 minutes.
Locking part of Z-595 EHT is fully identical in dimensions with a CAM LOCK mechanical lock,
which enables installation of Z-595 EHT into any opening made for that lock.
Compact in size, supporting both single-user and multi-user modes, easy in installation,
programming and servicing, this lock is a perfect Access Control solution for various storage
places like work clothes locker, mailboxes, office furniture, trade equipment.
Z-595 EHT can operate in five different modes:
- Gym Mode keys are not tied to locks. Any key can open and close any free locker.
- Logic Mode keys are not tied to locks. Any key can open and close any free locker. The
number of used locker and battery levels are stored into keys. This is convenient when the
client forgets which locker he used. Can limit the allowed number of lockers per client
(1 to 15). Computerized journaling of attendance times, reports, software administrators audit.
- General Mode a typical lock controller operation: only the key(s) stored in the lock's memory
(maximum 24) can open that lock.
- Safe Deposit Box Mode the lock emulates safe deposit box operation. To open the lock, all
the keys stored in controller database (maximum 24) must be presented to it, one after
another.
- Custom Mode can be designed for your specific needs. We will issue custom firmware, to be
downloaded into the lock via an Z-2 USB RF-1996 adapter.
Z-595 EHT Operational Modes Comparison Table.
-
Note:Logic Mode requires special Atmel (T5557) keys and Lock Manager software.
Z-595 EHT www.ironlogic.me
Z-595 EHT RFID Electronic Furniture Lock
with EM-Marine & HID ProxCard II & Atmel (T5557) reader (125 kHz)
and standalone controller
User Manual
page 1
Feature Operational Modes
Gym
Logic*
General
Safe Deposit Box
Custom
Any key can open/close any locker + + +
Limit on lockers number that can be taken
by one bracelet. The operator defines the
maximum lockers number for one bracelet
(1…15)
+ +
Logging of free/taken lockers through time + +
Logging the gym attendance times + +
Information Kiosk (tells the client their
locker number, if forgotten)
+ +
Battery charge level stored into bracelet + +
Encryption, protection against bracelet
cloning
+ +
Locks setup and further use without a PC + + + +

page 2
Z-595 EHT www.ironlogic.me
12,5
45,0
20 6,0
22,5
32,8
2,0
38,8
22,5
A34 30 26 20
A
(mm)
ON
9V
5
18
63
5 6
4
2 31
ON
ON
ON
Alcohol
ON ON
2. MOUNTING

page 3
Z-595 EHT www.ironlogic.me
3. SPECIFICATIONS
- Working Frequency: .......................................................................125 kHz;
- Keys standards: ......................EM-Marine, Atmel (T5557), HID ProxCard II;
- Maximum number of keys: ........................................Normal - 24; Master - 4;
- Power: ...............................................................One 9V PP3/E type battery;
- NVRAM to store settings:................................................................. Present;
- Standby consumption current: ............................................................≤ 3 µA;
- Audio-visual status indication: ..................................buzzer, bicoloured LED.
- Operating temperature range: ........................................................0…40 °C;
- Case material: ......................................................silumin, steel, ABS plastic;
- Colour: ................................................................................................Silver;
- Dimensions, mm: ......................................................................150 x 40 x 27;
4. INITIAL POWER-UP, ADDING MASTER KEYS
In the factory settings, Z-595 EHT is set to Installer mode, its handle rotates freely, no Master or
Normal keys stored in memory.
To create Master keys, the initial power-up condition must be met: no keys in lock's memory.
Minding the polarity, please install a 9V PP3 type battery into lock's battery compartment. When
powered up, the lock issues short beeps and the LED blinks green for 16 s this shows that the
lock's memory is empty and the lock is ready to create Master key(s).
While the beeps are still sounding (within 16 s), approach the reader with a key, it will store it in
lock's memory as a Master key. Short beeps will stop, confirming that the first Master key was
successfully stored. To add more Master keys (up to 4 total), please approach the keys to be
programmed to the lock, one after another. Each key approach is acknowledged by the reader with
a short beep and a green LED flash. The Add Master Keys mode ends automatically in 16 s after
the last key touch, and the reader informs about the exit by five short beeps and a red LED flash.
If no keys could be stored as Master, repeat the power-up sequence again. This Master key
creation sequence can only be performed if the lock's memory is empty. Later, you will use the
created Master key(s) for programming.
5. SELECTION OF OPERATIONAL MODE BY 'ON' BUTTON
Note: Cannot select an operational mode without a Master key.
The lock supports four pre-customised operational modes:
- Gym mode allows not to tie keys to certain locks. Any key can open/close any free locker.
- Logic mode allows not to tie keys to certain locks. Any key can open/close any free locker. This
mode enables storing the number of used locker and its battery level into the key. This is
convenient when clientsforget which locker they have used. Counts how many lockers are used
this key (1…15). Computerized logging of attendance times, report generation, auditing the
software operators.
- General mode traditional lock controller operation: only the keys in lock's database (max. 24)
can open the locker. Operation principle: first key approach pops out the latch, second approach
draws the latch back in.
- Safe Deposit Box mode safe deposit box mode emulation. To open the lock, all the keys in
lock's controller database (max. 24) need to be presented to the lock, one after another.

page 4
Z-595 EHT www.ironlogic.me
At the factory, Gym mode is pre-selected. It is activated straight after adding the Master key(s). To
select a different operational mode, perform the following steps:
a. Disconnect power (extract the battery).
b. Press and hold ON button.
c. Connect power (insert the battery) and only after that, release ON button.
d. After ≤ 5 s, press ON button shortly once. The lock will respond with two audio and visual
signals. The lock is now in Logic Mode.
e. Press ON button shortly once. The lock will respond with three audio and visual signals. It is
now in General Mode.
f. Press ON button shortly once. The lock will respond with four audio and visual signals. It is now
in Safe Deposit Box Mode.
g. Press ON button shortly once. The lock will respond with one audio and visual signals. It is now
in Gym Mode.
h. To confirm the currently selected mode or retain the previously selected mode, just do nothing
for 6 s. After these 6 s, exit from mode selection will be confirmed by audio and visual signal.
6. GYM MODE.
Note: Cannot select an operational mode without a Master key.
Rules of operations for Gym mode:
1) Opening the lock is possible with the key stored when door was locked.
2) Lock closing. Press ON button, then while the LED is blinking red and green (12 s), touch the
lock reader with a key. If the key is valid, the LED shines solid green for 6 s; during this time, turn
the lock handle into closed position. After lock is closed, the LED goes off.
3) Lock opening. Press ON button, then while the LED is blinking red and green (12 s), touch the
lock reader with the same key used when closing the lock. The LED shines solid green for 6 s;
during this time, turn the lock handle into open position. After lock is opened, the LED goes off
and the key is erased from lock's memory. The lock is ready for step 1 again. If a key not stored in
lock's memory was attempted at its reader, a beep sounds and the LED flashes red.
Legend: - beep once, - multiple beeps, G LED flashes green once,
R LED flashes red once, “blink” blinking multiple times.
Action
Sound
LED
Handle
What for
Opening/Closing the lock with a User key
Default state None None OPEN Standby Mode
Press ON button R and G blink OPEN Waiting 12 s for the User key
to be stored into memory
Approaching a key G Turn into CLOSED Closing the lock
Press ON button, approach a
wrong key
R blink CLOSED Wrong key indication
Press ON button, approach a
correct User key
G Turn into OPEN Opening the lock, erasing the
User key from memory,
standby for next User key
Master key override, KEEPING the User key in memory
Door closed. Press ON button,
approach a Master key
R blink Turn into OPEN Master key override: opening
the lock
Within 10 s, turn the handle
into closed position
R blink Turn into CLOSED Master key override: closing
the lock, User key remains in
memory
Master key override, ERASING the User key from memory
Door closed. Press ON button,
approach a Master key
R blink Turn into OPEN Master key override: opening
the lock.
Wait 10 s R blink OPEN Master key override: erasing
the User key from memory.
Standby for next User key.

page 5
7. LOGIC MODE
Note 1: Cannot select an operational mode without a Master key.
Note 2:Logic mode works only in cooperation with Lock Manager software and Z-2 USB RF-1996
adapter.
Note 3:Logic mode works only with Atmel (T5557) keys.
.
Rules of operations for Logic mode:
1) Opening the lock is possible with the key stored when the door was locked.
2) Lock closing. Press ON button, then while the LED is blinking red and green (12 s), touch the
lock reader with a key. If the key is suitable, the LED shines solid green for 6 s; during this time
turn the lock handle into closed position. After the lock is closed, the LED goes off.
3) Lock opening. Press ON button, then while the LED is blinking red and green (12 s), touch the
lock reader with the same key used when closing the lock. The LED shines solid green for 6 s;
during this time turn the lock handle into open position. After the lock is opened, the LED goes
off, and the key is erased from lock's memory. The lock is ready for step 1 again. If a key not
stored in memory was attempted at the reader, a beep sounds and the LED flashes red.
Z-595 EHT www.ironlogic.me
Action
Sound
LED
Handle
What for
Open/Close the lock with a User key
Default state None None OPEN Standby Mode
Press ON button R / G blink OPEN Waiting 12 s for a User key to be
stored into memory
Approach a key G Turn into CLOSED Closing the lock; locker number,
lock battery charge info, used
lockers number limit – stored into
User key.
Press ON button, approach a
wrong key
R blink CLOSED Wrong key indication
Press ON button, approach a
correct User key
G Turn into OPEN Opening the lock, erase key from
memory, standby for next User
key
Master key override, KEEPING the User key in memory
Door closed. Press ON button,
approach a Master key
R blink Turn into OPEN Master key override: opening the
lock
Within 10 s, turn handle into
closed position
R blink Turn into CLOSED Master key override: closing the
lock, User key remains in memory
Master key override, ERASING the User key from memory
Door closed. Press ON button,
approach a Master key
R blink Turn into OPEN Master key override: opening the
lock.
Wait 10 s R blink OPEN Master key override: erasing the
User key from memory. Standby
for next User key.

8. GENERAL MODE
Note: Cannot select an operational mode without a Master key.
Rules of operation for General mode.
1) Opening the lock is possible by the key(s) stored in lock's memory.
2) Lock closing. Press ON button, then while the LED is blinking red and green (12 s), touch the
lock reader with a key stored in memory. If the key is valid, the LED shines solid green for 6 s;
during this time turn the lock handle into closed position. After lock is closed, the LED goes
off. If a key not stored in memory was attempted at the reader, a beep sounds and the LED
flashes red.
3) Lock opening. Press ON button, then while the LED is blinking red and green (12 s), touch the
lock reader with a key stored in memory. The LED shines solid green for 6 s; during this time
turn the lock handle into open position. After lock is opened, the LED goes off. The lock is ready
for step 1 again. If a key not stored in memory was attempted at the reader, a beep sounds and
the LED flashes red.
page 6
Z-595 EHT www.ironlogic.me
Action
Sound
LED
Handle
What for
Adding User keys into lock’s memory
Default state None None Free while no User
keys in memory
Standby Mode
Press ON button G / R blink Free while no User
keys in memory
Lock activation (12 s)
Approach the Master
key 1st time
R blink Free while no User
keys in memory
Entering User key
editing mode.
Approach the Master
key 2nd time
R blink Free while no User
keys in memory
Entering User key
editing mode.
Approach the Master
key 3rd time
R blink Free while no User
keys in memory
Entering User key
editing mode.
Approach 1st, 2nd, 3rd…
(? 24) keys
G Free while no User
keys in memory
Entering User key
editing mode.
Approach the Master
key or waiting 5 s
R blink Blocked Exiting Add User Key
mode into lock’s
memory
Erasing All User keys from lock’s memory
Default state None None OPEN/CLOSED Standby Mode
Press ON button G / R blink OPEN/CLOSED Lock activation (12 s)
Approach the Master
key 1st time
R blink OPEN Entering User key
editing mode.
Approach the Master
key 2nd time
R blink OPEN Entering User key
editing mode.
Approach the Master
key 3rd time
R blink OPEN Entering User key
editing mode.
Press ON button once R blink OPEN Erasing all User keys
from lock’s memory
Approach the Master
key or wait 5 s
R blink Blocked Exiting Erase All User
keys from lock’s
memory
Master key override, opening the lock
Default state None None OPEN/CLOSED Standby Mode
Press ON button G / R blink OPEN/CLOSED Lock activation (12 s)
Approaching Master
key once
R blink Turn to OPEN Turn handle into open
state
Wait 10 s R blink Blocked Standby mode

9. SAFE DEPOSIT BOX MODE
Note: Cannot select an operational mode without a Master key.
Rules of operation for Safe Deposit Box mode.
1) Opening the lock is possible by ALL the key(s) stored in lock's memory, approached to the
lock's reader one by one.
2) Lock closing. Turn the handle to closed position (no keys to approachor ON button to press).
3) Lock opening. Press ON button, then while the LED is blinking red and green (12 s), touch
the lock reader with ALL the keys stored in memory, one after another. The LED shines solid
green for 6 s; during this time turn the lock handle into open position. After lock is opened,
the LED goes off. The lock is ready for Step 1 again. If a key not stored in memory was
attempted at the reader, a beep sounds and the LED flashes red.
page 7
Z-595 EHT www.ironlogic.me
Action
Sound
LED
Handle
What for
Adding User keys into lock memory
Default state None None Free while no User
keys in memory
Standby Mode
Press ON button G / R blink Free while no User
keys in memory
Lock activation (12 s)
Approachthe Master
key 1st time
R blink Free while no User
keys in memory
Entering User key
editing mode.
Approachthe Master
key 2nd time
R blink Free while no User
keys in memory
Entering User key
editing mode.
Approach the Master
key 3rd time
R blink Free while no User
keys in memory
Entering User key
editing mode
Approach 1st, 2nd, 3rd…
(? 24) keys
G Free while no User
keys in memory
Storing User keys into
lock’s memory
Approach Master key
or wait 5 s
R blink Blocked Exiting Add User Keys
mode into lock’s
memory
Erasing All User keys from lock’s memory
Default state None None OPEN/CLOSED Standby Mode
Press ON button G / R blink OPEN/CLOSED Lock activation (12 s)
Approach the Master
key 1st time
R blink OPEN Entering User key
editing mode.
Approach the Master
key 2nd time
R blink OPEN Entering User key
editing mode.
Approach the Master
key 3rd time
R blink OPEN Entering User key
editing mode
Press ON button once R blink OPEN Erasing all User keys
from lock’s memory
Approach the Master
key or wait 5 s
R blink Blocked Exiting Erase All User
Keys from lock’s
memory
Master key override, opening the lock
Default state None None OPEN/CLOSED Standby Mode
Press ON button G / R blink OPEN/CLOSED Lock activation (12 s)
Approach the Master
key once
R blink Turn to OPEN Turn handle into open
state
Wait 10 s R blink Blocked Standby mode

page 8
10. RESET TO FACTORY DEFAULTS
This function resets the device to factory (initial) state. All Master and Normal keys are
erased, the currently selected operational mode is cancelled.
To reset to factory defaults, please perform the following steps:
a. Disconnect the power;
b. Push and hold the ON button;
c. Connect the power (re-insert the battery). Continue holding down the ON button for 16 s.
The audio and visual signals will appear as follows:
- when powered on, 1 long beep and red LED,
- at 6 s, 1 beep and red LED,
- at 16 s, long beep sequence and red LED.
d. The beep and visual signal at 16 s denote that the lock has been reset to factory defaults.
e. Release ON button, in 3 s the lock issues short beeps and the LED blinks green for 16 s.
This indicates that lock's memory is empty and it is ready to store Master key(s). (See also
chapter INITIAL POWER-UP, ADDING MASTER KEYS).
11. PROGRAMMING USING Z-2 USB RF-1996 ADAPTER AND LOCK'S MANAGER
SOFTWARE
Lock's Manager software with an Z-2 USB RF-1996 adapter take care about configuration,
setting up and subsequent operation of electronic furniture locks.
Lock's Manager software comprises two modules:
- Edit Module: configures and sets up electronic furniture locks and keys for further
operations.
- Manager Module: takes care about day-to-day site operation. Manages keys, tracks
attendance, oversees staff operations, provides periodic reports, monitors the used lockers
numbers, provides the client info-kiosk function (reminds the locker number to the client, in
case they forget), monitors battery levels in the locks, protects against fraudulent card
cloning.
The software works only in Logic Mode and with Atmel (T5557) keys.
Programming works as follows:
- Install Edit Module onto a laptop (so can be carried around and taken to each lock for
programming).
- Connect a Z-2 USB RF-1996 adapter to the laptop.
- Assign Master card(s).
- Approach the Z-2 USB RF-1996 adapter to the lock's reader, to store the selected
operational mode and the Master card into that lock via contactless technology. The
transmission takes 2…3 s after the laptop has been connected to the lock.
Z-595 EHT www.ironlogic.me
USB
Lock
Z-2 USB RF-1996 Adapter
LOCK’S
MANAGER
ON

page 9
12. BATTERY DISCHARGE SIGNS AND
REPLACEMENT.
The lock's battery will suffice for at least 20,000
openings, or to work 2.5 years in stand-by mode.
The lock monitors the battery charge and informs the
users when the battery need to be replaced:
- Battery needs replacing.
If when pressing ON button, no beep sounds but the lock
is still working that lock's battery is almost discharged
and needs replacing. If the battery could not be timely
replaced and the lock lacks energy to open the locker,
please use external power through provided contact
pads, press ON button and approach a valid key. See
Figure.
- Battery fully discharged.
If when pressing ON button, no beep sounds, and the
latch can't lock/unlock the lock it means that lock's
battery is fully discharged.
- Battery replacement.
The lock's electronics includes NVRAM for settings and
keys, so they are not lost after battery replacement. To
replace the lock's battery, please see Figure.
13. FIRMWARE UPDATE
Z-595 EHT lock firmware can be updated and changed.
An Z-2 USB RF-1996 adapter and Lock's Manager
software are required for it.
14. PACKAGE CONTENTS
- Lock: ..........................................................................1;
- Sticker for the handle: ...............................................1;
- Locking bars of different sizes:.................................. 2;
- Guide plankto the side wall (for chipboard lockers): ..1;
- Mounting kit: ..............................................................1.
Z-595 EHT www.ironlogic.me
9V
9V
ON
ON

page 10
15. OPERATING CONDITIONS
Ambient temperature: +5…40°C.
Humidity: ≤ 98% at 25°C.
When operating under non-recommended conditions, device parameters can deviate from
specified values.
The device must be operated in absence of: precipitation, direct sunlight, sand, dust, and moisture
condensation.
16. LIMITED WARRANTY.
This Device is covered by limited warranty for 24 months.
The warranty becomes void, if:
- this Manual's guidelines are not followed;
- the device has suffered physical damage;
- the device has visible traces of exposure to moist and/or aggressive chemicals;
- the device circuits have visible traces of tampering by unauthorised parties.
Under this warranty, the Manufacturer shall repair the device or replace any broken parts as
required, free of charge, in cases where the fault is caused by a Manufacturer's defect.
17. CONTACTS
Authorized representative in the European Union
ICONTROL SIA
Slokas iela 79A, LV-1007, Riga, Latvia
E-mail: info@icontrol.lv
Phone: +37124422922
www.ironlogic.me
The symbol of crossed-throught waste bin on wheels means that the product
must be disposed of at f separate collection point. This also applies to the product
and all accessories marked with this symbol. Products labeled as such must not
be disposed of with normal household waste, but should be taken to a collection
point for recycling electrical and electronic equipment. Recycling helps to reduce
the consumption of raw materials, thus protecting the environment.
Z-595 EHT www.ironlogic.me
Table of contents
Other Iron logic Lock manuals
Popular Lock manuals by other brands

Sentrilock
Sentrilock NXT-M installation manual

Sargent and Greenleaf
Sargent and Greenleaf 6631 Operating and Combinatiion Changing Instructions

Nuctech
Nuctech SL3601 user manual

National Cabinet Lock
National Cabinet Lock C8710 Dimensional drawing

Vanderbilt
Vanderbilt CD30 Codoor Configuration manual

AmazonBasics
AmazonBasics TravelSentry B07SZ7732P manual