ITC Audio T-6230 User manual

Please follow the instructions in this manual to obtain the optimum resultsfrom this unit.
We also recommend that you keep this manual handyfor future reference.
DIGITAL PLAYER
OPERATION MANUAL
AUDIOAUDIO
PUBLIC ADDRESS SYSTEM
T-6230
POWER
T-6230
DIGITAL PLAYER
ON
OFF
AUDIO
5
0
1
2
3
4 6
7
8
9
10
VOLUME
2 4 68
LEVEL
RESET
ALARM LAYER
88

TABLE OFCONTENTS
T-6230 2
1. SAFETYPRECAUTIONS .......................................................................................3
2. GENERALDESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATUREAND FUNCTIONS
4.1 Front Panel............................................................................................................. 6
4.2 RearPanel..............................................................................................................7
5. CD .......................................................................................................8
6. APPLICATIONS .......................................................................................................9
7.SPECIFICATIONS .................................................................................................. 10
8.DIMENSIONAL DIAGRAM .................................................................................... 11
OPERATION
V1.0-2008-09-18

Be sure to read the instructions in this sectioncarefully before use.
Make sure to observe the instructions inthis manual as the conventions of safety symbols andmessages
regarded as very important precautions are included.
We also recommend you keep this instructionmanual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
3
1. SAFETY PRECAUTIONS
T-6230

An all-pole mainsswitch with acontact separation ofat least 3mm in eachpole shall beincorporated in
the electrical installationof the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so maycause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning. If dust
is allowed toaccumulate in the unit over a long
periodof time,a fire or damage to the unit may
result.
ITC
Ifdust accumulates onthepower supply plug orin
the wall AC outlet, a fire may result. Clean it
periodically.In addition, inserttheplug in thewall
outletsecurely.
Switchoff the power, andunplugthe power supply
plug from the ACoutlet for safety purposes when
cleaning or leaving theunitunused for 10 daysor
more.Doingotherwise maycause a fire or electric
shock.
1. SAFETY PRECAUTIONS
4
T-6230

5
3. FEATURES
The T-6230 is a public address digital player with can provide an ideal public address solution from small to
big places such us mosques, schools, hotels and factories to train stadium and air stations.
2. GENERAL DESCRIPTION
=Digital recorder/player for voice announcements .
=256 MB memory, expandable to 64TB .
T-6230

POWER
ON
OFF
T-6230
DIGITAL PLAYER
5
0
1
2
3
4 6
7
8
9
10
VOLUME
2 4 68
LEVEL
RESET
ALARM LAYER
6
1. POWER
Power indicator
2. POWER SWITCH
On top of the opening Power
Press the end, power shut down
3. ALARM LAYER
Display the working
4. NOMENCLATUREAND FUNCTIONS
23
4. ALARM LAYER
Reset button
5. VOLUME
Volume control
6. LEVEL INDICATORS
Level meters 4 output level indicators
1
4.1 FRONT PANEL
4
T-6230
5
6

NOMENCLATURE ANDFUCTIONS
7
7. 4 ADDRESS CODE CHOICE
8. LINE INTERFACE
9. AUDIO SIGNAL OUTPUT
10.USB DATA PORT
(and USB devices)
11.~230V/50HZ AC POWER INTERFACE
4.2 REAR PANEL
11
78
T-6230
OUTPUT
L
R
COM
ADDRESSTAG
USB
~230V 50Hz
T1AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
910

8
5. OPERATION
T-6230
USAGE METHODS
1. Use USB wire connect computer with equipment by
USB access, and send the
recorded audio warning music to equipment
2. Connect well with all wires and power on.
3. When fire intelligent access collect zone warning
short circuit signals, triggering audio warning player
by net wires, play relative programs repeatedly.
Such as: Fire intelligent access collect the fifth areas
short circuit, audio warning player was triggered, and
play the fifth program, if there is no the fifth program,
then it can play last time program
4. Adjust the volume button to monitor, press REST
button to stop audio warning.

6. APPLICATIONS
REAR PANEL CONNECTIONS
9T-6230
~230V 50Hz
T1AL250V
AUDIO
OUT
RR
LL
COM
ADRESSTAG
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
AUDIO SOURCES
12345678MP3
910 11 12 13 14 15 16
VOLUME IN
AUDIO IN
AUDIO OUTA
AUDIO OUTB CH1(5A) CH2(5A) CH3(5A) CH4(5A) CH6(5A)CH5(5A)
~230V 50Hz
T0.5AL250V
CF CARD
COM1 COM2 EM
IN EM
OUT TM
OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
MATRIX CONTROLLER
MIC 4 MIC 3 MIC2 MIC 1 EMC 1 EMC 2
OUTPUT
AUX 3 AUX 2 AUX1
INPUT
INPUT
~230V 50Hz
T1AL250V
MIC 4MIC 5 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2
LINE INPUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
MIXER PRE-AMPLIFIER
USB PORT
OUTPUT
L
R
COM
ADDRESSTAG
USB
~230V 50Hz
T1AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:

7.SPECIFICATIONS
10
T-6230
MODEL
DIGITALPLAYERDIGITALPLAYER
T-6230
DIMENSION(mm)
NET WEIGHT
GROSS WEIGHT
484X368X88
POWER CONSUMPTION
POWER REQUIREMENTS
~230V/50Hz
5.9Kg
4.7Kg
20W

100
Over
100
Over
Over
100
8. DIMENSIONALDIAGRAM
UNIT :mm
6
84 84
25
337
331
88
94
436
484
UNIT :mm
11 T-6230
OUTPUT
L
R
COM
ADDRESSTAG
USB
~230V 50Hz
T1AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
POWER
ON
OFF
T-6230
DIGITAL PLAYER
5
0
1
2
3
4 6
7
8
9
10
VOLUME
2 4 68
LEVEL
RESET
ALARM LAYER
POWER
ON
OFF
T-6230
DIGITAL PLAYER
5
0
1
2
3
4 6
7
8
9
10
VOLUME
2 4 68
LEVEL
RESET
ALARM LAYER

AUDIOAUDIO
Guangzhou ITC Electronic Technology Limited
Http://www.itc-pa.com.cn
PUBLIC ADDRESS SYSTEM
2008-08 Version1.1
Table of contents
Popular Media Player manuals by other brands

Conceptronic
Conceptronic CSM3PL Firmware Upgrade Instructions

DANE-ELEC
DANE-ELEC SO SPEAKY BLACK DIAMOND quick start guide

Toshiba
Toshiba GigaBeat F60 owner's manual

TriangleTube
TriangleTube AIO C user manual

Arec
Arec KL-3 Quick installation guide

LaCie
LaCie 301450U - LaCinema RECORD - Digital AV... user manual