iZone 220 Quick guide

Installation, Configuration & User Manual
for
iZone 220 & iZone 320

Section Description Page No.
1.0 Installation
1.1 iZone 220—Wiring layout for base system up to 8 zones 6
1.2 iZone 220—Wiring layout for base system up to 9 to 14 zones 7
1.3 Stan alone VAV system for a typical 4 zone system 8
1.4 iZone 320—Wiring layout for base system up to 8 zones 9
1.5 iZone 320—Wiring layout for base system up to 9 to 14 zones 10
1.6 Optional equipment for wireless temperature controlle zones 11
1.7 Optional equipment for wire temperature sensors 12
1.8 Optional equipment for iSense temperature an occupancy controlle zones 13
1.9 Optional equipment for colour touch screen temperature controlle zones 14
1.10 Example of ifferent types of temperature sensors an controllers on a single system 15
1.11 Option equipment for wire WiFi control of system 16
1.12 Option equipment for wireless WiFi control of system 17
1.13 iZone 320—Optional equipment for iSave a ition (up to 6 zones) 18
1.14 iZone 320—Optional equipment for iSave a ition (7 to 12 zones) 19
1.15 iZone 320—Optional equipment for Ethernet Home Automation connection 20
1.16 iZone 320—Wiring connection to AC units 21
1.17 iZone 320—Wiring connection to LG units 22
1.18 iZone 320—Wiring connection to Temperzone units 23
1.19 General installation instructions 24
Table of contents

Table of contents
Section Description Page No.
2.0 System initialisation 25
2.1 During initialisation 26
3.0 System Configuration 27
3.1 Configuration main menu 28
3.2 Zone setup 29-30
3.2.1 Sensor configuration 31
3.2.2 Pairing an configuring iZone RF sensors 32
3.2.3 Sensor calibration 33
3.2.4 iSense controller configuration 34
3.3 AC unit configuration (iZone 320 only) 35
3.3.1 Fan auto configuration 36
3.3.2 Fan auto zone area setup 37
3.4 System options (Display, Taglines, Filter Maintenance, Locks) 38-39
3.5 WiFi bri ge configuration 40
3.5.1 Manual IP configuration 41
3.5.2 WiFi connection 42
3.5.3 Smart phone, tablet an PC configuration 43-45
3.6 Home automation integration 46

Table of contents
Section Description Page No.
4.0 User Manual 47
4.1 iZone 220 home screen 47
4.2 iZone 320 home screen 48
4.3 iZone 320 AC unit control 49
4.4 Zone control 50
4.5 E it zone names an settings 51
4.6 A justing temperature controlle zones 52
4.7 Zone airflow summary 53
4.8 Changing zone airflows 54
4.9 Favourites 55
4.10 Assigning an e iting favourites 56
4.11 Sche ules 57
4.12 Setting an e iting a sche ule 58
4.13 Setting the time 59
4.14 Changing the home screen colour 60
4.15 iSense controller 61
4.16 Warranty registration 62
4.17 Airstream pro uct warranty policy 63
4.18 Further assistance 64


1.1 iZone 220 - Wiring layout for base system up to 8 zones
8 Zone system with 1 colour touch screen shown above
A maximum of 14 zones and 12 colour touch screens can be supported by
one iZone system (See Network Extension Module 1.3 for Details)
iZone

1.2 iZone 220 - Wiring layout for base system 9 to 14 zones
iZone
14 Zone system with 1 colour touch
screen shown above
A maximum of 14 zones and 12 colour touch
screens can be supported by one iZone sys-
tem (See Network Extension Module 1.3 for
Details)

1.3 Stan alone VAV systems - Wiring layout for typical 4 zone
system
4 Zone system shown above. (CVAV4)
A maximum of 14 zones and 14 iSense controllers can be supported by one
iZone system. For CVAV1 to CVAV3 no CNEM is required

1.4 iZone 320 - Wiring layout for base system up to 8 zones
8 Zone system with 1 colour touch
screen shown above
A maximum of 14 zones and 12 colour touch
screens can be supported by one iZone sys-
tem (See Network Extension Module 1.3 for
Details)

1.5 iZone 320 - Wiring layout for base system 9 to 14 zones
14 Zone system with 1 colour
touch screen shown above
A maximum of 14 zones and 12 colour
touch screens can be supported by one
iZone system (See Network Extension
Module 1.3 for Details)

1.6 Optional equipment for wireless temperature controlle zones

1.7 Optional equipment for wire temperature sensors

1.8 Optional equipment for iSense temperature an occupancy
controlle zones

1.9 Optional equipment for colour touch screen temperature
controlle zones

1.10 Example of ifferent types of temperature sensors &
controllers on a single system

1.11 Optional equipment for wire WiFi Control of system

1.12 Optional equipment for wireless WiFi control of system

1.13 iZone 320 - Optional equipment for iSave a ition
(up to 6 zones)
Note:
When the iSave option is used with an 8 zone system it is limited to a
maximum of Zones
Use Zone 8 port on CC220 for Outsi e Air ampers
Use Zone 7 port on CC220 for Return Air ampers

1.14 iZone 320 - Optional equipment for iSave a ition (7-12 Zones)
Note:
When the iSave option is used with the CEXT the iZone system is limited to
a maximum of 12 Zones
Use Zone 14 port on CEXT for Outsi e Air
ampers
Use Zone 13 port on CEXT for Return Air
ampers

1.15 Optional equipment for Ethernet Home Automation connection
This manual suits for next models
1
Other iZone Control Unit manuals
Popular Control Unit manuals by other brands

Veethree
Veethree VeeCAN 320 instructions

Dometic
Dometic AH Series Installation and operating manual

AERMEC
AERMEC MODUCONTROL Summarized User manual

FlowCon
FlowCon S-JUST Installation and operation instruction

RJG
RJG Lynx IA1-M-V product manual

Aumuller
Aumuller M-COM Click Assembly and commissioning instructions