12
ENGLISH
The surround consists of the following
parts (fi g. 2):
Part Description Qty
1 Guide pin Ø6X25 8 stk
2 Woodscrew Ø6x80 EZ 8 stk
3 Hex Cap Screw DIN933-M8x16-8.8 Zinc Plated 24 stk
4 Hex Flange Nut M6 DIN6923 8 4 stk
5 Distance sleeve 4 stk
6 Brakett front 1 stk
7 Bracket left side middle uprofi le 1 stk
8 Profi le side øvre uprofi l 2 stk
9 Firewall FS 173 2 stk
10 Bracket for height adjustment 2 stk
11 Bracket right side middle uprofi le 1 stk
12 screen plate part FS 173 1 stk
13 Height adjustment screw M8x54 1 stk
14 Bottom Plate 1 stk
15 Lower Anchoring Profi le 1 stk
16 Upper Anchoring Profi le 1 stk
17 Upper Binding Profi le 1 stk
18 Top Upper Anchoring Profi le 1 stk
19 Top Front Anchoring Profi le 1 stk
20 Bracket front uprofi le 2 stk
21 Steel plate back low 2 stk
22 Soapstone side upper R 1 stk
23 Soapstone front up 2 stk
24 Soapstone lower front 2 stk
25 Soapstone side low left 1 stk
26 Soapstone side lower right 1 stk
27 Soapstone side middle L/R 2 stk
28 Soapstone side upper L 1 stk
29 Sector valve pl compl FS 173 1 stk
30 Soapstone FS 173 1 stk
31 Steel support for soapstone 1 stk
35 Sector valve upper part 1 stk
36 Sector valve lower part 1 stk
3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are fi tted by a qualifi ed installer
(see www.jotul.com for a complete list of dealers).
Any modifi cations to the product may result in the product and
safety features not functioning as intended. The same applies to
the installation of accessories or optional extras not supplied by
Jøtul. This may also be the case if parts that are essential to the
functioning and safety of the fi replace have been disassembled
or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
3.1 Fire Prevention
Measures
There is a certain element of danger every time you use
your fi replace. The following instructions must therefore
be followed:
• The minimum safety distances when installing and using
the fi replace are given in fi g. 1.
• Ensure that furniture and other fl ammable materials are not
too close to the fi replace. Flammable materials should not
be placed within 1 metre of the fi replace.
• Allow the fi re to burn out. Never extinguish the fl ames with
water.
• The fi replace becomes hot when lit and may cause burns
if touched.
• Only remove ash when the fireplace is cold. Ash can
contain hot embers and should therefore be placed in a
non-fl ammable container.
• Ash should be placed outdoors or be emptied in a place
where it will not present a potential fi re hazard
3.2 Floor
Foundation
Make sure that the foundation is strong enough to bear the
weight of the fi replace (110 kg + 274 kg).
We recommend the removal of any fl ooring that is not attached
to the foundation (“fl oating fl oors”) beneath the installation.
Requirements for protection of wooden
fl ooring beneath the fi replace
The product has integrated fl oor protection and may therefore
be placed directly on a wooden fl oor.
Requirements for protection of
combustible fl oors in front of the
fi replace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.3 Walls
Distance to walls made of combustible materials - see fi g. 1.
The fi replace may be used with a semi-insulated fl ue pipe provided
the distances between the fi replace and walls made of combustible
materials are as shown in fi g. 1.
NB: Make sure that furniture and other household items are not
so close as to get dried up by the stove.