UC-280 wireless interface 1 / 2 MFT51202
UC-280 Wireless Interface
The UC-280 is an 8-zone interface linking JA-60 wireless detectors
with hard-wired security control panels. It can also send triggering
signals to a JA-60A wireless outdoor siren and/or UC-216 and UC-222
universal receivers. Additionally, it can receive signals from Jablotron
RC-xx remote controls. If necessary, UC-282 expander modules can
be used to increase the number of zones up to 40.
Specification
Power 12VDC(10.5V–16.0V)
Power consumption typ. 50 mA (all relays off)
max. 150 mA
Zone outputs Z1-Z8 8 relays 50 mA / 50 V
with COM1 common terminal
Tamper, fault, battery outputs 3 relays 50 mA / 50 V
with COM2 common terminal
X, Y and Siren inputs activated when switched to GND
(filter 0.2 sec., 3 V DC triggering
level)
Operating frequency 433.9 MHz
Working range with JA-60 100 m (open area)
Working range with RC 30 m (open area)
Working environment indoor use (class II, EN 50131-1)
Operating temperatures -10 °C to +70 °C
Operating humidity max. 90 %
Dimensions 188 x 135 x 40 mm
Weight 800 g
Purchase package contains: electronic board, metal case, antenna,
screws, dowels, and manual.
Installation
The UC-280 is an electronic module built-in to a metal case
(protected by a tamper switch). The case should be installed on a wall
with its antenna in a vertical position. The device should not be
installed close to any metal structures or other objects obstructing radio
signal transmission.
Route the wires through the hole in the rear part of the housing.
Attach the case to the desired place using the provided screws.
Connect the antenna and the tamper switch.
Terminals:
Z1-Z8 Zone 1-8 output relays’ contacts, max. 50 mA / 50 V, pulse
length can be set by 1s/3s jumper, normally closed or
normally opened mode is selected by the NO/NC jumper
COM1 common terminal of Z1-Z8 relays
TMP tamper relay output (tamper signal from wireless detectors,
a wireless siren and the UC-280 tamper switch), max. 50 mA
/50V
BAT low battery relay output (low battery signal from wireless
detectors 1-8 or a wireless siren), max. 50 mA / 50 V
TRB trouble relay output (trouble signal from wireless detectors
1-8 or a wireless siren - e.g. lost communication), max.
50 mA / 50 V
COM2 common terminal of TMP, BAT and TRB relays
GND power supply ground terminal
SIR triggering input for activation of JA-60A wireless siren (the
siren sounds as long as this input is closed to GND, max.
15 minutes)
Xinput, which can trigger relay X of a UC-216 or UC-222
universal receiver when switched to GND
Yinput, which can trigger relay Y of a UC-216 universal
receiver when switched to GND
OUT input, which can trigger output OUT of a UC-216 universal
receiver when switched to GND
+12V power voltage terminal
TAMPER a pair of terminals used for the connection of the UC-280
case tamper switch
UC-280 wireless interface 2 / 2 MFT51202
Connectors:
OUT data connector for UC-282 expander module
ANT AN-01A external antenna connector (when AN-01A is used,
the rod antenna must be disconnected)
Setting buttons:
LEARN if this button is briefly pressed, you can scroll through the
learning modes of Z1-Z8 zones and a wireless siren SIR (a
selected channel is indicated by a red flashing LED). When
this button is pressed for more than 3 sec., the enrolling
signal for a UC-216 / UC-222 receiver will be transmitted
(learning mode of Z1-Z8 and SIR must be closed first)
RESET if this button is briefly pressed, the learning mode of a
selected zone will be closed. When this button is pressed for
more than 3 sec., a selected zone will be deleted (confirmed
by flashing of the TMP, BAT and TRB indicators). When this
button is pressed for more than 6 sec., all zones will be
deleted (confirmed by flashing of all indicators). Note, in
order to delete all zones, a learning mode of any zone must
be selected first.
Jumpers:
1s / 3s pulse length of 1 sec. or 3 sec. of Z1-Z8 output relays
NO / NC normally closed or normally opened mode of Z1-Z8 output
relays (TMP, BAT and TRB are normally closed)
Supervision - Regular checking of wireless detectors’ communication
can be disabled (NO SUPERVISION position). This setting
is recommended in places with radio interferences. When
the supervision is enabled, lost communication will trigger
the TRB output relay.
Indicators:
POWER The green LED indicates the presence of the power supply
Z1 -Z8, LED lights green when zone is occupied;
LED lights red when zone detector is triggered;
LED flashes red, when zone is in a learning mode;
LED flashes red together with the TMP, BAT or TRB LED =
tamper, low battery or trouble signal in zone
TMP tamper alarm – flashes together with a corresponding zone
indicator every 3 sec.
BAT low battery - flashes together with a corresponding zone
indicator every 3 sec.
TRB trouble or lost communication - flashes together with a
corresponding zone or SIR indicator every 3 sec.
Enrolling of wireless components
Enrolling of detectors and remote controls
• Scroll to a desired zone Z1-Z8 using the LEARN button
• JA-60 detectors will be enrolled by inserting their batteries or
switching on a power supply
• RC-xx remote controls will be enrolled by pressing a button (for
pulse mode)
• RC-11 or RC-22 remote controls can also be enrolled to any zone in
an ON/OFF mode by pressing both buttons and keeping them
pressed for more then 5 sec. After this the corresponding relay will
switch on when the A button is pressed, and off, when the B button
is pressed.
• Successful learning is indicated by the red LED
• If you enroll an existing component to a new position, it will move
from its previous position
• Only one detector or remote control can be enrolled to each zone
Enrolling of a wireless siren
• Connect a battery in a JA-60A siren and power its adapter
• Select the SIR position with the LEARN button
• When the SIR position is selected, the UC-280 will send a learning
signal to the JA-60A and vice versa. Triggering the SIR input will
then activate a JA-60A, tamper alarm or power supply failure of the
JA-60A will be transmitted to a UC-280
• Only one JA-60A siren can be used with a UC-280
Enrolling of UC-216 or UC-222 modules
• Select the learning mode in a receiver (mode X1 for UC-216 or
mode 4 for UC-222)
• Learning mode of UC-280 must be closed
• Press and hold the LEARN button in UC-280 for 3 seconds
• The UC-280 will now be enrolled to the UC-216 or UC-222 receivers
and triggering of X and Y inputs will trigger the UC-216 / UC-222
output relays.
• Unlimited number of UC-216 / UC-222 can be used with a UC-280
Erasing components
If you want to delete any item from a UC-280, use the RESET button
(the procedure is described in “Setting buttons” paragraph).
Extension for more zones
When 8 zones are not enough, you can use UC-282 expander
modules. Each UC-282 module provides additional 8 zones. A
maximum of 4 expanders can be used with UC-280. Modules are
interconnected using the IN and OUT connectors, wiring should not
exceed 1 meter. Each UC-282 must be powered by 12 V DC
separately.
fax: 420-428-313183
tel.: 420-428-346911
www.jablotron.cz
export@jablotron.cz
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic
SIR

Other jablotron Recording Equipment manuals

jablotron JA-111R User manual

jablotron

jablotron JA-111R User manual

jablotron UC-280 User manual

jablotron

jablotron UC-280 User manual

jablotron JA-121T User manual

jablotron

jablotron JA-121T User manual

Popular Recording Equipment manuals by other brands

NKE NMEA 183 User's installation guide

NKE

NKE NMEA 183 User's installation guide

Fostex DV-824 Owner's manual supplement

Fostex

Fostex DV-824 Owner's manual supplement

Atomos Ninja V quick start guide

Atomos

Atomos Ninja V quick start guide

Roger UT-2USB operating manual

Roger

Roger UT-2USB operating manual

Velleman K8045 manual

Velleman

Velleman K8045 manual

Roland AX-7 owner's manual

Roland

Roland AX-7 owner's manual

Rockville REQ231 owner's manual

Rockville

Rockville REQ231 owner's manual

Panasonic AYNE2000 - NONLINEAR AV WORKSTA installation manual

Panasonic

Panasonic AYNE2000 - NONLINEAR AV WORKSTA installation manual

Olivetti Explor 200XS Service manual

Olivetti

Olivetti Explor 200XS Service manual

PAC uPAC-GMC2 quick start guide

PAC

PAC uPAC-GMC2 quick start guide

Festo CAMC-D-8E8A Assembly instructions

Festo

Festo CAMC-D-8E8A Assembly instructions

RSS AR-200S brochure

RSS

RSS AR-200S brochure

Waves Maserati B72 user guide

Waves

Waves Maserati B72 user guide

Korg D1200 mkII owner's manual

Korg

Korg D1200 mkII owner's manual

Rath 2100-Series Installation & operation manual

Rath

Rath 2100-Series Installation & operation manual

Eurotherm Drives Metasys N2 Technical manual

Eurotherm Drives

Eurotherm Drives Metasys N2 Technical manual

Yamaha M7CL-48 quick start guide

Yamaha

Yamaha M7CL-48 quick start guide

Harris Legacy 99-1300-0 Operation & technical manual

Harris

Harris Legacy 99-1300-0 Operation & technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.