jbc FAE1-B User manual

Fume Extractor
Ref. FAE1-B
INSTRUCTION MANUAL
www.jbctools.com

Fume Extractor
Ref. FAE1-B
www.jbctools.com
INSTRUCTION MANUAL
H13 Filter & Carbon Filter
& M5 Pre-filter ........................................... 1 unit
Ref. FAE1-100
*Already assembled
Packing List
The following items are included:
Fume Extractor ......................................... 1 unit
Ref. FAE1-1B (100V / 120V)
FAE1-2B (230V)
Unseal the filter
before the first use
Manual ................................................. 1 unit
Ref. 0023483
Power cable ........................................... 1 unit
Ref. 0009417 (100V / 120V)
0009401 (230V)
RJ12 direct cable ................................ 2 units
Ref. 0019751
RJ12-USB A adapter ........................... 1 unit
Ref. 0023504
USB A/B cable ..................................... 1 unit
Ref. 0021042
2

Features
Aspiration tubes for 1 workbench and up to 4 stands (1 work intake
configuration) or for 2 workbenchs (2 work intakes configuration).
Quick release
levers for filter
change
Power socket
Main switch
Process screen
USB-B connection Pedal connection
RJ12 station
connections
Filter saturation indicator
Green: Filter OK
Yellow: ≤ 20% carbon lifetime or about to saturate
Red: End of carbon lifetime or filter saturated
www.jbctools.com
3

FlowFlow
HML
Saturation 20%
FilterFilter
Carbon life 90%
Aspiration
ON
FlowFlow
Saturation 20% 100%
FilterFilter
Carbon life 90%
Aspiration
ON
Fume Extractor
Ref. FAE1-1B (100V / 120V)
FAE1-2B (230V)
Accessory for
stand aspiration
(up to 4 stands)
Ref. FAE040
To be assembled on
your workbench with
the included clamp
Ref. FAE030
To be assembled directly
on your workbench (hole
drilling required)
Stand
Aspiration Duct
Ref. FAE050
For modular stands
(From SD versions
onwards)
Ref. FAE060
For compact stations
(From B versions
onwards)
Flexible arm Ø50
Ref. FAE070
Lenght: 1 m (39.37 in)
To be assembled on
your workbench with
the included clamp
Ref. FAE020
To be assembled directly
on your workbench
(hole drilling required)
Flexible Hoses Ø50
Ref. FAE010
Lenght: 1,5 m
(59.05 in)
Connect the Fume Extractor
indifferently to the flexible
arm or to the accessory for
stand aspiration
Attention
Avoid awkward positions
in order to minimize
pressure losses
1 work intake configuration assembly (default configuration)
Main screen
Preset program screen Custom program screen
Troubleshooting
Station troubleshooting available on the product page at www.jbctools.com
High, medium and low
aspiration programs Aspiration status
Flow rate
4

20%
Saturation
Aspiration
ONON
Carbon life
80%
Fume Extractor
Ref. FAE1-1B (100V / 120V)
FAE1-2B (230V)
Flexible arms Ø50
Ref. FAE070
Lenght: 1 m (39.37 in)
To be assembled on
your workbench with
the included clamp
Flexible Hoses Ø50
Ref. FAE010
Lenght: 1,5 m
(59.05 in)
Connect the Fume
Extractor to the flexible arm
Attention
Avoid awkward positions
in order to minimize
pressure losses
2 work intakes configuration assembly (optional configuration)
Main screen
Troubleshooting
Station troubleshooting available on the product page at www.jbctools.com
Aspiration status
In this configuration aspiration at stand is not available, aspiration flow is set High. Note that in this
configuration, suction force per intake is decreased when compared to 1 work intake configuration (see
details on page 14). Change Work intakes parameter into 2 in order to set this configuration (see page
7).
Ref. FAE020
To be assembled directly
on your workbench
(hole drilling required)
www.jbctools.com
5

STOPSTOP ##44
Cover opened or badly
closed. Double check the
cover.
FlowFlow
HML
Saturation 20%
FilterFilter
Carbon life 90%
Aspiration
ON
FlowFlow
HML
Saturation 20%
FilterFilter
Carbon life 90%
Aspiration
ON
FlowFlow
Saturation 20% 100%
FilterFilter
Carbon life 90%
Aspiration
ON
20%
Saturation
Aspiration
ONON
Carbon life
80%
If the display shows STOP#4, power off the fume extractor, remove the cover, place it back and
secure it using the quick release levers.
Menu Interface
Main Screen
Main screen may vary according to the Work intakes and Program parameters. For 1 work intake
configuration the aspiration flow can be changed by keys, whereas for 2 work intakes configuration
the flow cannot be changed.
Change the aspiration
Custom level and the
aspiration Preset program.
Turning on the fume extractor
Once the fume extractor is turned on, the display shows a similar screen as the following one and
the filter saturation indicator is green if the carbon lifetime is higher than 20%.
Troubleshooting
Station troubleshooting available on the product page at www.jbctools.com
1 work intake configuration12 work intakes configuration2
6

PortPort
1 Pedal
BackBack
4 Filter set
5 Counters
6 Program version
Main menuMain menu
Exit
1 Reset
2
Unit
3
Port
UnitUnit
1 Continuous mode OFF
2
Beep ON
3 PIN OFF
4 Change PIN
Filter setFilter set
1 Carbon life 90%
2 Saturation 20%
3 Reset carbon
BackBack
CountersCounters
1 Total
2 Partial
BackBack
PortPort
1 Program Ctm - 100%
2
Delay to stop
3
Pedal
BackBack
Total CountersTotal Counters
1 Plugged hrs 100
2 Idle hrs 10
3 Work area hrs 70
4 Stand hrs 20
5 Work area cys 10
BackBack
Partial CountersPartial Counters
1 Plugged hrs 100
2 Idle hrs 10
3 Work area hrs 70
4 Stand hrs 20
5 Work area cys 10
6 Reset
BackBack
5 Work intakes 1
BackBack
Menu Interface
Main menu parameters
Original PIN: 0105
1 work intake configuration12 work intakes configuration2
Not available for
2 work intakes
configuration
www.jbctools.com
7

Delay to stopDelay to stop
1 Stand 30 sec
BackBack
PedalPedal
1 Activation One-touch
2 Mode Pressed
BackBack
Custom programCustom program
Select work area flow
80 %
PortPort
1 Program Ctm - 100%
2
Delay to stop
3
Pedal
BackBack
PortPort
1 Program Ctm - 100%
2
Delay to stop
3
Pedal
CustomCustom
BackBack
PortPort
1 Pedal
BackBack
PedalPedal
1 Activation One-touch
2 Mode Pressed
BackBack
Menu Interface
1Port menu 1 work intake configuration
OK
2Port menu 2 work intakes configuration
8

Parameters
Important: Power off any Station or Device connected to the fume extractor before
modifying any parameter.
Unit
Parameter Description
Continuous mode
Enable/disable continuous aspiration. When enabled, fume extractor
suction is activated. Aspiration remains active until continuous mode is
disabled or the equipment is powered off.
By default Continuous mode is OFF.
Beep
Enable/disable the sound of the keypad.
By default Beep is ON.
PIN
Enable/disable PIN request when modifying parameters.
By default PIN is ON.
Change PIN
Change the default security PIN code.
By default the PIN is 0105.
Work intakes
It sets how many intakes will work as workbench extractions. The options
are 1 and 2.
By default Work intakes is 1.
www.jbctools.com
9

Port
Parameter Description
Program
It sets the fume extractor aspiration flow. You can select between Preset
and Custom aspiration programs.
H (High), M (Medium) or L (Low) are the three Preset available options.
Use Up and Down keys to switch between them while being on the main
screen.
Up to ten aspiration levels between H (High) and L (Low) can be selected
for Custom program (range 10-100%). If a Custom aspiration program
is selected, the selected aspiration level can be changed on the main
screen.
By default M (Medium) aspiration program is selected.
Delay to stop /
Stand
It sets the time that a fume extractor keeps aspirating fumes at the stand
once the tool is returned to it (range 0-999 seconds)
By default Stand time is 60 seconds.
Pedal / Activation
It sets the pedal activation mode.
One-touch: Press the pedal once to activate aspiration. Press again to
stop aspiration.
Pressed: (Mode function must be Pressed) aspiration is active as long as
the pedal is kept pressed.
By default Activation is Pressed.
Pedal / Mode
When the activation parameter is set to Pressed, the Mode parameter can
be configured to Released mode. In this mode aspiration is always active
until the pedal is pressed.
By default Mode is Pressed.
10

Extraction control
Fume extractor aspiration may be controlled by:
Pedal connection
By means of the Pedal connection, fume extractor aspiration may be activated/deactivated by a
P-005/P-405 pedal. (See pedal activation modes on page 10)
Filter set
Parameter Description
Carbon life
It shows remaining activated carbon lifetime expressed in %. It is also
displayed on the main screen. When 0% is reached the system will show
pop-up message STOP#1 to replace the filter.
Saturation
It shows saturation status of HEPA + carbon filter set, expressed in %. It is
also displayed on the main screen. When 100% is reached the system will
show pop-up message STOP#2 to replace the filter.
Reset carbon
Perform this action after replacing the HEPA + carbon filter set. The car-
bon lifetime counter will not start until the filter is detected for the first time.
After executing that function Carbon life will be 100%.
www.jbctools.com
11

17:14
Peripherals Port 1-T245
Pedal None
Module None
Fume extractor FAE_a
Back
RJ12 station connections for Excellence range
Allows connecting JBC Soldering Stations featuring a Robot port to the fume extractor in order to
automatically activate the extraction when the tools are in use. An RJ12 direct cable is required (ref.
0019751).
RJ12 cable
Connect up to 4 stations directly to a fume extractor through the Soldering Station Robot port.
Every tool connected to a station can control the aspiration system, but previously it has to be
assigned to the fume extractor through the Peripherals menu of the station. Each station detects a
fume extractor as a FAE_a.
For a correct operation always update soldering stations with the latest available software version.
The minimum required version is 8886160 for DDE, HDE and NAE stations and 8886162 for DME
stations.
12

RJ12 station connections for Advanced range
Allows connecting JBC Soldering Stations featuring a USB-B port to the fume extractor in order to
automatically activate the extraction when the tools are in use. An USB A/B cable (ref. 0021042) and
RJ12-USB A adapter (ref. 0023504) are required. (You must not configure anything on the soldering
station).
RJ12-USB A adapter
+
USB A/B
Update
Allows updating a fume extractor via the USB-B connector.
Update the equipment software
Fume extractor can be updated by means of JBC Updater software. If you want to update
the equipment be aware there is not a station connected to RJ12 connectors. If a station is
connected to RJ12 connector the update process will not start. Download software from:
https://www.jbctools.com/software.html.
Continuous mode
When continuous mode is enabled, fume extractor suction is activated. Aspiration remains active
until continuous mode is disabled or the equipment is powered off (see details on page 9).
Fume extractor aspiration control priority:
RJ12 station connections / pedal > Continuous mode function
www.jbctools.com
13

Fume extractor configurations
Some parameters, features and the performance vary depending on fume extractor configuration,
see the following table:
230V 50/60Hz 1 work intake 2 work intakes
Work aspiration intakes 1 2
Stand aspiration intakes 1Not available
Flow per work intake 80 m3 / h (47.08 cfm) 60 m3 / h (35.31 cfm)
Preset aspiration programs 3 1
Custom aspiration programs 10 Not available
Power consumption 110 W 115 W
120V 50/60Hz 1 work intake 2 work intakes
Work aspiration intakes 1 2
Stand aspiration intakes 1 Not available
Flow per work intake 80 m3 / h (47.08 cfm) 60 m3 / h (35.31 cfm)
Preset aspiration programs 3 1
Custom aspiration programs 10 Not available
Power consumption 115 W 135 W
100V 50/60Hz 1 work intake 2 work intakes
Work aspiration intakes 1 2
Stand aspiration intakes 1 Not available
Flow per work intake 75 m3 / h (44.14 cfm) 55 m3 / h (32.37 cfm)
Preset aspiration programs 3 1
Custom aspiration programs 10 Not available
Power consumption 100 W 105 W
14

Maintenance - Filter replacement
- The unit notifies through both the display and
the LED when filters need maintenance.
- To replace the filters remove the cover by
opening the quick release levers of the
casing.
- If the saturation indicator remains in red
after changing the pre-filter, it means that
H13 particle filter is already saturated and
must be replaced too.
- See Filter replacement instruction on
page 16.
- When the H13 particle filter has been
replaced, the carbon filter counter must be
reseted.
(Main Menu > Filter set > Reset carbon)
The duration of the compact filter is 1 year
maximum after its packaging is opened.
- If the filter is changed while the fume
extractor is on, the unit starts the filter
detection process, activating aspiration
for a few seconds.
M5 Pre-filter
Re f. FA E1-110
H13 Filter
& Carbon Filter
H13 Filter & Carbon Filter
& M5 Pre-filter
Ref. FAE1-100
www.jbctools.com
15

-
+
Quick Release Levers Adjustment
- Turn clockwise to loosen and counterclockwise to tighten, in order to adjust the filter airtightness.
Read safety guidelines to do the equipment maintenance safely.
Connect the filter tube to
the quick coupling placed
on the metal sheet
The filter has a given position.
Make sure the filter ribs mate
with the corresponding slots.
Maintenance - Filter replacement
16

Safety
- The equipment is only designed to filtrate the fumes generated by soldering.
- Do not use the units for the filtration of combustible, explosive or corrosive gasses.
Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded
before use. When unplugging it, hold the plug, not the wire.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- This appliance can be used by children over the age of eight and persons with reduced
capabilities or lack of experience provided that they have been given adequate supervision or
instruction concerning use of the appliance and understand the hazards involved.
- Maintenance must not be carried out by children unless supervised.
- Keep your workplace clean and tidy. Wear appropriate protective mask, glasses and gloves when
handling dirt filter or pre-filter.
- Do not use the equipment without the filters.
- Saturated filters can not be cleaned and reused.
- Avoid blowing the filter or the dirty parts of the equipment, if necessary it is advisable to vacuum.
- Avoid losing particles in the filter during handling it.
- Treat the saturated filters as waste depending on the filtered contaminant and the applicable
standars in each country. This is the European Waste Catalog classification:
15 02: Absorbents, filter materials, wiping cloths and protective clothing.
15 02 02: Absorbents, filter materials (including oil filters not otherwise specified, wiping cloths,
protective clothing contaminated by dangerous substances.
15 02 03: Absorbents, filter materials, wiping cloths and protective clothing.
- In case of not complying with the filter change recommendations, the maximum particle and gas
concentrations established in each country could be exceeded.
Follow safety guidelines to prevent electric shock, injury, fire or explosion.
www.jbctools.com
17

Notes
18

Notes
www.jbctools.com
19

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
be collected and returned to an authorized recycling facility.
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/
within 30 days of purchase.
www.jbctools.com
0023483-0420
Specifications
FAE1-1B 100V 50/60Hz. Input power: 105W Fuse 2A
120V 50/60Hz. Input power: 135W Fuse 2A
FAE1-2B 230V 50/60Hz. Input power: 115W Fuse 1.25A
- Weight: 10.5 kg (23.2 lb)
- Dimensions: 382 x 344 x 476 mm (15 x 13.5 x 18.7 in)
- Blower type: Brushless
- Blower max. flow rate: 180 m³/h (106 CFM)
- Blower max. vacuum: 3.2 kPa (0.46 psi)
- Work areas: 1
- Noise: 55 dB @ 1m
- Pre-filter: Medium dust filter M5 (EN 779)
- Compact Filters: H13 particle filter (EN 1822)
Activated carbon filter
- Connections: USB-B
Pedal connector
4 RJ12 connectrors
Complies with CE standards.
ESD protected.
This manual suits for next models
3
Table of contents
Other jbc Scrubber manuals
Popular Scrubber manuals by other brands

SapphireScientific
SapphireScientific Dri-Eaz HVE3000 owner's manual

Grizzly
Grizzly H8375 owner's manual

Miele
Miele ProLine CSDA 1010 Operating and installation instructions

RCm
RCm TERA Series Instruction and maintenance handbook

Minuteman
Minuteman Port A Scrub 14 instruction manual

Comet
Comet CPS 45E manual