4. INSTALLATION INSTRUCTIONS
4.1 Assembling
To assemble the heater, proceed as follows
1. Insert the wheel shaft K to the corresponding hole of feet pipe B,insert the
cotter J to the corresponding holes; slide the wheel I over the wheel shaft K
put plain washer H to the two sides of shaft,,screw the nut G to fix the wheel
2. Put the heater body on the feet pipe assembly, make sure the 4 holes of
handle A point towards the corresponding 4 holes on the feet pipe
3. Using the screw F ,spring washer E, plain washer D and nut C to fix the feet
pipe assembly and handle to the tank.
4.2 Installation
Position the heater on a flat, level, non-flammable, solid surface.
The exhaust gases are very harmful for people and animals when
released in a closed space without ventilation.
Indirect-fired heaters while used in indoor installation, must be connected
to an exhaust pipe to vent the products of combustion outside. To maintain an
adequate Oxygen rate, a minimum of 80 m3/h airflow from outside must be
ensured.
Direct-fired heaters are intended for use in outdoor open areas or in
indoor well ventilated areas. For indoor use, provide permanent ventilation
openings of at least 25 cm²/kW, equally distributed between floor and high level,
with a minimum of 250 cm².
● Only install the heater in normal upright position.
● Do not place the heater near walls, corners or low ceilings.
● Do not place the heater below a socket outlet.
● Do not place the heater on moving vehicles or where it can tip over.
● Keep the heater away from flammable, combustible, explosive or corrosive
materials.
● Keep the heater away from curtains or similar materials that could block the air
inlet and outlet.
● Never block or restrict the air inlet and outlet for any reason.
● Keep the power cable away from heat sources, sharp edges, cutting and
moving parts.
● Do not expose directly to the weather or to excessive humidity.