PON-55
PASSIVE OPTICAL NETWORK
POWER METER FOR
BPON/EPON/GPON, APC
INSTRUCTION MANUAL
3
3. dBm/W
a. You can change the output units from dBm to W or vice versa by pressing the UP or
DOWN arrow buttons and ENTER to select.
4. Language
a. You can change the language to Chinese or English or vice versa by pressing the UP or
DOWN arrow buttons and ENTER to select.
5. Time Set
a. You can change the date and time of the device by pressing the UP or DOWN arrow
buttons and ENTER to confirm.
6. History Data
a. Data View - You can view the latest saved data here.
b. Del Cur - Deletes the latest saved data.
c. Del All - Deletes all saved data on the device.
4. Setting Custom Thresholds
The PON-55 can store up to 10 different threshold settings. Download and use the following software to set up
your own thresholds to easily read whether the power output is within the specified range.
Software can be downloaded at: jonard.com/PON50
Below is an example of a custom threshold:
In this example, the threshold range is between +3 ~ -20 dBm.
PASS: If the measured result is between this range for the 1310 nm wavelength, then the LED above the 1310
nm marking will illuminate green, indicating that it passes.
WARN: If the measured result is between -20~-30 dBm, the optical signal is in the warn status, and the LED
above the 1310 nm marking will illuminate yellow.
FAIL: If the measured result is above +3 dBm or below -30 dBm, the optical signal is out of the threshold range,
and the LED above the 1310 nm marking will illuminate red.
Troubleshooting
Problem
Possible Cause
Solu�on
No display on the LCD /
Cannot turn on the device
1. Power is o
1. Press the Power buon for 2 seconds to turn it on
2. No Baery
2. Change the Baery
Inaccurate readings /
Instability
1. Opcal Interface is not clean
1. Clean the adapter heads and ber cable surface
2. Improper ber connecon
2. Reconnect the ber using the correct adapters
OVERVIEW:
Designed to perform live testing with OLT equipment, this PON Power Meter is perfect for use during
FTTx/PON service tune-up or maintenance. It is able to simultaneously test and measure the signal power of
voice, data, and video connections, and is an essential tool for the construction and maintenance of PON
systems.
PRODUCT FEATURES:
- Analyzes voice, data, and video signals in BPON/EPON/GPON FTTx systems
- Concurrently measures 1310 nm, 1490 nm, and 1550 nm wavelengths anywhere in the network
- Three Pass, Warning, and Fail LED indicators allow you to quickly assess your network's power level
- USB port allows quick transfer of data, and up to 1,000 measurement items can be saved at once
- Optional 10-minute auto-off can be activated or deactivated
- Shatter-resistant sleeve protects it from accidental falls or other damage
SPECIFICATIONS:
jonard.com | PON-55 Instruction Manual
12
INSTRUCTIONS:
1. Powering the Device ON and OFF
a. Power the device ON by pressing the Power button for 2 seconds. The unit will display the
following on the screen:
b. The power symbol on the screen indicates that the 10 minute auto-off is activated. Short press
the Power button to disable this auto-off feature.
c. To turn the device off manually, press the Power button for 2 seconds.
2. PON Power Meter Testing
The PON-55 can simultaneously measure the PON network upstream signals of 1310 nm, downstream data
signals of 1490 nm, and descending output video signals of 1550 nm. After powering the device on while not
connected, the optical channels will display “LOW”. Also, ensure you have selected the correct Threshold via the
Options Menu before proceeding. If you have not set any thresholds yet, the default one will be used.
a. Before connecting the fiber cables to be tested, ensure they are cleaned well using fiber cleaning
fluid for optimal test results.
b. Choose the appropriate adapter heads (SC or ST), connect them to the PON-55, and connect the
corresponding fiber optic cables into them.
c. Power ON the PON-55 via the Power button and it will display the output power for each
wavelength being used.
d. While at this test interface, press ENTER to prompt you if you want to save the data. Press ENTER
again to save the data or CANCEL to back out.
3. Options Menu
a. Press the MENU button and press ENTER on PON PM to enter the options menu.
b. Press the UP or DOWN arrow buttons to navigate the menu. Press ENTER to choose an option or
CANCEL to back out of the MENU. There are 6 options to choose from:
1. REF
a. Relative output power measurements’ reference values can be set.
b. Relative Power = Testing Value – REF value.
c. Press the UP or DOWN arrow buttons to select different wavelengths and press ENTER
to change the REF value.
2. Threshold
a. You can change the Threshold values here by pressing the UP and DOWN arrow
buttons and ENTER to select which Threshold to use. There is one preset Threshold,
but you can choose additional ones by setting them up in the provided software.
PON OPTICAL POWER METER MODULE
1310 Upstream Measurement
Pass Zone (nm) 1260 nm ~ 1360 nm
Measurement Range (dBM) -35 dBm ~+ 10 dBm
Output Power (max) 15 dBm
Isolation @ 1490/1550 (dB) >40 dB
Burst Mode Measurement Error < ± 0.5 dB
Pass Zone (nm) 1470 nm ~ 1505 nm
Measurement Range (dBm) -35 dBm ~+ 10 dBm
Output Power (max) 15 dBm
Isolation @ 1310/1550 (dB) >40 dB
1550 Downstream Measurement
Pass Zone (nm) 1535 nm ~ 1570 nm
Measurement Range (dBm) -35 dBm ~+ 20 dBm
Output Power (max) 15 dBm
Isolation @ (1310/1490 nm) >40 dB
Measurement Accuracy
Connatural Uncertainty (dB) ± 0.5 dB
Linearity (dB) ± 0.1 dB
Passing through Insertion Loss (dB) <1.5 dB
General Information
Detector Type InGaAs
Optical Connector (APC) FC/SC/ST Interchangeable/ 2.5 Universal Adapter
Fiber Type SM 9/125 um
Measurement Unit dB/dBm/xW
Resolution (dB) 0.01 dB
Operation Voltage (V) DC 3.3 V ~ 5.5 V
Power Supply 3 pc 1.5 V Battery
Continuous Operation Time (h) 90 h
Operation Temperature (°C) -10°C ~ 70°C
Storage Temperature (°C) -25°C ~ 70°C

Other JONARD TOOLS Measuring Instrument manuals

JONARD TOOLS FLS-55 User manual

JONARD TOOLS

JONARD TOOLS FLS-55 User manual

JONARD TOOLS FPM-55 User manual

JONARD TOOLS

JONARD TOOLS FPM-55 User manual

JONARD TOOLS FPM-50a User manual

JONARD TOOLS

JONARD TOOLS FPM-50a User manual

JONARD TOOLS FLS-50 User manual

JONARD TOOLS

JONARD TOOLS FLS-50 User manual

JONARD TOOLS ACM-1000 User manual

JONARD TOOLS

JONARD TOOLS ACM-1000 User manual

JONARD TOOLS OTDR-1500 User manual

JONARD TOOLS

JONARD TOOLS OTDR-1500 User manual

JONARD TOOLS PON-55 User manual

JONARD TOOLS

JONARD TOOLS PON-55 User manual

JONARD TOOLS OFI-100 User manual

JONARD TOOLS

JONARD TOOLS OFI-100 User manual

JONARD TOOLS PON-50 User manual

JONARD TOOLS

JONARD TOOLS PON-50 User manual

JONARD TOOLS PON-55 User manual

JONARD TOOLS

JONARD TOOLS PON-55 User manual

JONARD TOOLS FPM-50 User manual

JONARD TOOLS

JONARD TOOLS FPM-50 User manual

Popular Measuring Instrument manuals by other brands

PROF 502212378 instruction manual

PROF

PROF 502212378 instruction manual

Seahorse XF24 Training manual

Seahorse

Seahorse XF24 Training manual

Newport INF-B Operation manual

Newport

Newport INF-B Operation manual

Reftek 130-SMHR/9 user guide

Reftek

Reftek 130-SMHR/9 user guide

Nokeval 575F manual

Nokeval

Nokeval 575F manual

Euromag EUROSONIC 2000 HH user manual

Euromag

Euromag EUROSONIC 2000 HH user manual

IFM Electronic SI5007 operating instructions

IFM Electronic

IFM Electronic SI5007 operating instructions

Siemens OCM III instruction manual

Siemens

Siemens OCM III instruction manual

Opti-Med JM022-001 user manual

Opti-Med

Opti-Med JM022-001 user manual

Keysight Technologies N9030A Installation note

Keysight Technologies

Keysight Technologies N9030A Installation note

Hanna Instruments HI 83748 instruction manual

Hanna Instruments

Hanna Instruments HI 83748 instruction manual

KPS KPS-PF10 instruction manual

KPS

KPS KPS-PF10 instruction manual

Hamron 619-566 User instructions

Hamron

Hamron 619-566 User instructions

Anritsu MT8802A Service manual

Anritsu

Anritsu MT8802A Service manual

Prismatibro Prisma DI-5 manual

Prismatibro

Prismatibro Prisma DI-5 manual

Allen-Bradley 1756-CFM user manual

Allen-Bradley

Allen-Bradley 1756-CFM user manual

dymax ACCU-CAL 150 user guide

dymax

dymax ACCU-CAL 150 user guide

Minebea CSD-904-EX instruction manual

Minebea

Minebea CSD-904-EX instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.