TL20 Adjustable Joiner
1. Remove dead-end from Trac.
2. Slide TL20 endfeed connector into Trac over
buss bars. Tighten endfeed Trac attachment
screw and terminal block set screws.
3. Secure TL20 cover to TL20 endfeed connector.
4. Remove cover from endfeed of other Trac and
attach jumper cord wires using terminal block
set screws. Tighten screws to a torque of 7 in/lb.
minimum.
5. Carefully remove center breakout from endfeed
cover and secure cover onto endfeed connector.
TL21 Outlet Box/T-Bar Ceiling Feed
A. Feeding Trac from outlet box:
1. Attach mounting plate in outlet box.
2. Remove and discard cover from endfeed
connector and mount endfeed connector to
mountingplateusing1/2˝screw.
3. Mount Trac to ceiling.
4. Attach secondary transformer wires to end
feed connector using set screws. Tighten
screws to a torque at 7 in/lb. minimum.
5. Secure cover to mounting plate (if feeding
more than one (1) Trac, carefully remove the
corresponding breakout in canopy).
B. Feeding Trac in T-bar Ceiling:
1. Attach TL37 T-bar clip (ordered separately) to
T-bar runner, and then install mounting plate
to TL37.
2. Secure secondary wires to mounting plate
using1/2˝conduitorBXfitting(notsupplied).
3. Mount Trac to ceiling using TL37 T-bar clips
at12˝intervals.Tocompleteinstallation,
follow steps 4 & 5 described above.
TL24 Right Angle Joiner
1. Remove dead-end from Trac.
2. Slide TL24 endfeed connector into Trac over
buss bars. Tighten endfeed Trac attachment
screw and terminal block set screws.
3. Remove cover from endfeed of other Trac.
4. Slide formed wires into endfeed connector and
tighten set screws. Tighten screws to a torque of
7 in/lb. minimum.
5. Secure right angle cover onto both endfeed
connectors.
TL34 Conduit Feed
1. FastenconduitorBXtobracketeitherthrough
end knockout with coupler fitting (supplied) or
through top knockout with standard conduit or
BXfitting(notsupplied).
2. Fasten bracket to mounting surface.
3. Remove and discard endfeed cover from Trac
endfeed connector.
4. Fasten endfeed connector to bracket with screw,
and mount Trac to ceiling.
5. Attach secondary transformer wires to endfeed
connector using set screws. Tighten screws to a
torque of 7 in/lb. minimum.
6. Secure cover to bracket.
IMPORTANT SAFETY/OPERATING
INSTRUCTIONS
1. Read and save all instructions.
2. Do not install this Trac in wet locations.
3. Do not install any fixture assembly closer than 6
inches from any curtain or similar combustible
material.
4. Trac intended to be connected to 12 volt second-
ary of an isolated type transformer supply.
5. Use only fixtures and fittings intended for use with
Juno TL series Trac.
6. Do not exceed 20 amp capacity of Trac (240
watts at 12 volts).
7. Reference local electrical/building codes for
approved wiring techniques.
TRAC INSTALLATION
A. Installing Trac 12 using standard
endfeed connector:
1. Attach Trac to mounting surface using #6
toggle bolts or wood screws (supplied) at
12˝intervals.
2. Remove endfeed cover and loosen terminal
block set screws.
3. Insert 12 volt supply wire from transformer
secondary and tighten set screws. Tighten
screws to a torque at 7 in/lb. minimum.
(Do not use wire smaller than No. 12 AWG).
4. If wire is being fed in from end, carefully
remove center breakout tab from cover and
re-install onto endfeed.
Note: See separate instructions for installing Trac in
conjunction with TL34 conduit feed. TL21 out-
let box canopy, or in-line with TL546/TL547
transformers.
B. Joining Trac sections:
1. Remove dead end from first Trac.
2. Remove endfeed cover from second Trac.
3. Insert end of first Trac attachment screw and
terminal block set screws over buss bars.
Tighten screws to a torque at 7 in/lb.
minimum.
4. Breakoutendofcoverandre-installonto
connector.
C. Field cutting instructions:
1. Remove dead-end and endfeed connector.
2. Loosen endfeed Trac attachment screw and
pull out endfeed so buss bars pass point
where Trac will be cut.
3. Cut Trac with fine-tooth hack saw, slide
endfeed with buss bars back into Trac and
re-tighten Trac attachment screw.
4. Usingside-cutters,cutbussbars1/4˝longer
than Trac and re-install dead-end or desired
connector.
INSTALLATION INSTRUCTIONS
For Juno TL Series Low Voltage Trac
©2016 Acuity Brands Lighting, Inc. Printed in USA Rev 2/16 P1927A pg 1 of 2
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com

For Juno TL546/TL566U and TL547/TL567U
ELECTRONIC Transformers
IMPORTANT SAFETY/OPERATING INSTRUCTIONS
1. Do not install TL547/TL567U surface transformer in hot attics or in confined or
unventililated areas which may entrap heat.
2. Do not install TL547/TL567U surafce transformer more than 5 feet from Trac.
(For distances more than 5 feet, use TL549 magnetic transformer).
3. TL546/TL566U & TL547/TL567U electronic transformers will automatically shut-
off in the event of a short circuit on the secondary. Normal operation will resume
when short circuit is corrected.
4. TL546/TL566U & TL547/TL567U electronic transformers will automatically shut-
off or dim lamps if more than 150 watts of lamps are installed on trac. Normal
operation will resume when wattage is reduced.
5. TL546 and TL547 electronic transformers require at least a 50 watt load to
function properly.
6. TL546/TL566U & TL547/TL567U electronic transformers may be dimmed using
most better quality standard incandescent dimmers.
(Note: Under certain conditions, use of ELV dimmers specifically designed for
use with electronic transformers may be required to circumvent “cross-talk inter-
ference” or audible noise problems).
A. TL546 150VA/TL566U 100VA CANOPY TRANSFORMER
1. Attach mounting plate to outlet box.
2. Remove and discard cover from Trac endfeed and mount Trac to mounting
plateusing1/2˝screw.
3. Attach Trac to ceiling with toggle bolts or wood screws.
4. Attach transformer prmary wires (black & white) to branch circuit wires with
wire nuts.
5. Fasten transformer secondary wires (red) to endfeed connector using set
screws. Tighten screws to a torque of 7 in/lb. minimum.
6. Secure canopy cover to mounting plate.
B. TL547 150VA/TL567U 100VA SURFACE TRANSFORMER
1. Remove cover and mount transformer bracket.
2. Attach120voltsupplytoswitchendofbracketwith1/2˝conduitfitting
(by others).
3. Attach positive wire to available switch wire using wire nut.
4. Attach neutral wire to transformer neutral (white) using wire nut.
5. Fasten ground wire to green ground screw on bracket.
6. Remove cover from Trac endfeed.
7. If mounting transformer separately from Trac, use (2) No. 12 AWG 300 Volt
minimum wires and attach one to each of the transformer secondary wires
(red) with wire nuts. Attach the other ends to the Trac endfeed connector
using terminal block set screws. Tighten screws to a torque of 7 in/lb.
minimum.
If mounting transformer inline with Trac, remove rectangular Trac knockout.
Attach transformer secondary wires (red) to endfeed using set screws.
Tighten screws to a torque of 7 in/lb. minimum. Attach Trac endfeed to
transformer bracket.
8. Secure cover onto transformer bracket.
WARRANTY
Juno Lighting Group warrants that its products are free from defects in material and workmanship. Juno Lighting Group’s obligation is expressly
limited to repair or replacement, without charge, at Juno Lighting Group’s factory after prior written return authorization has been granted. This
warranty shall not apply to products which have been altered or repaired outside of Juno Lighting Group’s factory. This warranty is in lieu of all
other warranties, expressed or implied, and without limiting the generality of the foregoing phrase, excludes any implied warranty of merchantabil-
ity. Also, there are no warranties which extend beyond the description of the product on the company’s literature setting forth terms of sale.
Product Services Phone (888) 387-2212
©2016 Acuity Brands Lighting, Inc. Printed in USA Rev 2/16 P1927A pg 2 of 2
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
INSTALLATION INSTRUCTIONS
TL546, TL566U CANOPY TRANSFORMER
TL547, TL567U SURFACE TRANSFORMER
This manual suits for next models
4
Other JUNO Transformer manuals
Popular Transformer manuals by other brands

Monacor
Monacor Stage Line FGA-102 quick start guide

Ashly
Ashly SRA-TR2 Installation

Intermatic
Intermatic PX100 Installation, operation & service manual

Altronix
Altronix T1618300 installation instructions

LightPro
LightPro 144A Manual and safety instructions

Titanium
Titanium TT-DR-CVR-060 instruction manual