Feature: The most important
feature of this controller is
intelligent tracking input voltage
from solar panel, which could let
solar panel always working at
Maximum Power Point of V-A
curve. Compared with normal solar
charge controller, this MPPT
controller could increase 10%-30%
electrical power using efficiency from solar panel.
Function: This MPPT controller is not only have above mentioned special function, at the
same time including completely Protecting and Controlling functions:
Overcharge Protection
Overdischarge Protection
Battery Reverse Current Protection
Overloading Protection
Short Circuit Protection
Battery Reverse Polarity Connection Protection
Schematic Diagram: Picture 2 shows typical 12V battery solar charge system V-A curve.
Normal Solar Charge Controller: Solar Panel works at point A state, the solar panel
working voltage is a little higher than battery voltage.
Charge Voltage: UA=13.2V
Charge Current:: IA=9.8A
Charge Power: PA=13.2*9.8=129.36w
Area in drawing: ①+③
MPPT Solar Charge Controller: Solar Panel works at
point B state, the solar panel working voltage much
higher than battery voltage.
Charge Voltage: UB=18.4V,
Charge Current:: IB=9.3A
Charge Power: PB=18.4*9.3=171.12w
Area in drawing: ①+②
Comparison: The power B is more than power A..
P/ PA=(PB— PA)/ PA=32..3%
As a result of different manufacture of solar panels, different solar illumination intensity, different
temperature, different efficiency of solar charge controller and so on. The effective power
increase rate is 10-30%.
Choose the model:
Solar Panel: 12V solar system should use 40pcs cells laminated solar panel. The maximum
power pointvoltage is18V above. 24V solar system should use 2pcs above mentioned solar
panels. 48V solar system should use 4pcs above mentioned solar panels.
Conductor: The cable between solar panel with MPPT solar charge controller should be better
calculated by 1Ampere per 1mm².
Solar Charge Controller: JUTA brand MPPT-10 Model solar charge controller Rated input
Ampere is 10A. We have 12V, 24V and 48V three kinds of MPPT solar charge controllers.
Fit for power of solar panels: 20—200Wp(12V), 40—400Wp(24V), 80-800Wp (48V).
Connection: ( As Picture 3 according to
below process)
1. Connected the “+”, “-” poles of the
battery to the controller ( 3, 4 from left)
firmly and correctly. At this time the
LOAD green LED is bright. If the LOAD
green LED is not bright, it is indicate
there is battery reverse polarity
connection. Only LOAD green LED is
bright, we could continue next step
operation.
2. Connected the “+”, “-” poles of the solar
panel to the controller (1,2 from the left)
firmly and correctly.
3. Connected the “+”, “-” poles of the LOAD to the controller (5,6 from the left) firmly and
correctly.
Simply Measure Methord: For 12V system, measure the input voltage from solar panel
with multimeter (terminal 1, 2 of controller), it is normal if the voltage of solar panel more
than battery voltage 0.5-6V. Generally, the higher input voltage, the better charge
efficiency. For 24v and 48V system, the input voltage will be much more higher than
battery voltage
(Note: It is normal phenomenon the controller can not find Maximum Power Point within
10 minutes from system start.)
Indicator: (Picture 1)
1. Load indicator, green, bright indicate there is output, Load could work, “off” indicate
there is not output, Load can not work.
2. Low Voltage Indicator, red, bright indicate the voltage of the battery is low. Load
could not normal working. This is normal phenomenon. When the battery voltage
recover to 12.6V or (25.2v), the Load will be automatically working, at this time the
indicator is off.
3. Charge Indicator, green, bright indicate the battery need to charge, flickering means
float charging, off means charge has stop.
RESET Button: The rated output current of this MPPT solar charge controller is 10A, if
there is short circuit or overload happened, the MPPT controller will close output. ( Load
indicator off, Low voltage indicator off.)
If you need the MPPT controller recover work, please check the reasons and clear out the
fault firstly. Then put a small stick such as toothpick, ball-pen tip inside the RESET hole,
and press RESET button will be OK.
Attention:
1. Please check the rated voltage of the solar panel, battery, load are all the same
with 12V or 24V or 48V.
2. Please pay attention to connection, the best way is that do not connect the “+”
“-” poles of battery wrong, never connect “+” “-” poles of Loads and solar
panels wrong.( Wrong connection will be possible burn your MPPT controller)
3. Battery must be connected earlier than solar panels and load. When take off the
system, Solar Panels must be take down first, then cut off battery.
4. The rated current of solar panel and load must be less than MPPT controller’s
rated current.

Other Juta Controllers manuals

Juta CM3024Z User manual

Juta

Juta CM3024Z User manual

Juta SR1012 User manual

Juta

Juta SR1012 User manual

Juta CM5024Z User manual

Juta

Juta CM5024Z User manual

Popular Controllers manuals by other brands

Danfoss ERC 211 installation guide

Danfoss

Danfoss ERC 211 installation guide

FS AC-224AP quick start guide

FS

FS AC-224AP quick start guide

Minebea Intec Maxxis 4 installation manual

Minebea Intec

Minebea Intec Maxxis 4 installation manual

YASKAWA motoman NX100 Operator's manual

YASKAWA

YASKAWA motoman NX100 Operator's manual

DINGO FW2170 user manual

DINGO

DINGO FW2170 user manual

Roco and Fleischmann 10798 manual

Roco and Fleischmann

Roco and Fleischmann 10798 manual

Uponor Smatrix Base PULSE Installation and operation manual

Uponor

Uponor Smatrix Base PULSE Installation and operation manual

GReddy PRofec B-specII instruction manual

GReddy

GReddy PRofec B-specII instruction manual

OGS Merlin 1000V+ Installation operation & maintenance

OGS

OGS Merlin 1000V+ Installation operation & maintenance

AT&T Digital Life DLC-200C Installation and operation manual

AT&T

AT&T Digital Life DLC-200C Installation and operation manual

Carrier 40WA900024 Installation and operating instructions

Carrier

Carrier 40WA900024 Installation and operating instructions

Turbosmart e-Boost 2 quick start guide

Turbosmart

Turbosmart e-Boost 2 quick start guide

3DS MAX Series user manual

3DS

3DS MAX Series user manual

Hayward CAT-2000 owner's manual

Hayward

Hayward CAT-2000 owner's manual

TopXGun T1 user manual

TopXGun

TopXGun T1 user manual

Honeywell ML6421 Product data

Honeywell

Honeywell ML6421 Product data

Parker P2M Node 24 DO user manual

Parker

Parker P2M Node 24 DO user manual

Hardy Process Solutions HI 2160RC PLUS Operation and installation manual

Hardy Process Solutions

Hardy Process Solutions HI 2160RC PLUS Operation and installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.