عDISASSEMBLY PROCEDURE
1. Removing the COMMON PWB
(1) Detach the 7 connectors.
(2) Remove the 8 screws [A].
(3) Remove the COMMON PWB.
2. Removing the DIGITAL PWB
(1) Detach the 6 connectors.
(2) Remove the 6 screws [B].
(3) Remove the DIGITAL PWB.
3. Removing the SCAN PWB
(1) Detach the 11 connectors.
(2) Remove the 7 screws [C].
(3) Remove the SCAN PWB.
4. Removing the SIGNAL RELAY PWB (upper left)
(1) Detach the 6 connectors.
(2) Remove the SIGNAL RELAY PWB (upper left).
5. Removing the SIGNAL RELAY PWB (upper right)
(1) Detach the 7 connectors.
(2) Remove the SIGNAL RELAY PWB (upper right).
6. Removing the SIGNAL RELAY PWB (lower left)
(1) Detach the 7 connectors.
(2) Remove the SIGNAL RELAY PWB (lower left).
7. Removing the SIGNAL RELAY PWB (lower right)
(1) Detach the 7 connectors.
(2) Remove the SIGNAL RELAY PWB (lower right).
Notes : Check the state of the detached cables and connectors.
(1) Check any dirt or peeling in the contact part of the flat cable, and any crack, crease, disconnection
and short-circuit of wires.
(2) Check any foreign substance in the connector's contact .
(3) Check the state of plugging the flat cable into the connector, and confirm it locks completely.
: Connector
COMMON
PWB
SCAN PWBDIGITAL PWB
SIGNAL RELAY PWB
(upper left)
SIGNAL RELAY PWB
(upper right)
SIGNAL RELAY PWB
(lower right)
SIGNAL RELAY PWB
(lower left)
AB
C