KaiDeng WVC Modem User manual

KaiDengWVCModem
UserManual
0
KaiDeng Energy Technology Co., Ltd
07/2012 V1.0

http://www.kaidengdg.com
1Summarize
1.1Background
KaiDengEnergytechnologyCo.,LTDasaprofessionalsolar,windpowergenerationsystemproviders,withthestrong
researchanddevelopment,design,productioncapacity,wealwayswillmeetthemaximizationanddiversificationdemand
ofuserasourservicestandards.From21century,solar,windandotherrenewablecleanenergyisappliedmoreandmore
widely,buttheexistingsolar,windpowergenerationsystemgenerallyhavethedifficulttomonitorandmaintenance,
KaiDeng’snewgenerationofcommunicationtypePVpowersystemcameintobeingandsolvethiskindofproblemperfect.
KaiDengWVCModemisaimportantpartofKaiDengcommunicationgenerationsystem.Thesuccessofresearchand
developmentofWVCModemhaveprovidedareliablerelaycommunicationdatasupportforcentralizedand
round‐the‐clockdevicesmonitoringmanagement.Andtheusercanthroughthismanualtounderstandingthedetailedof
KaiDengWVCModem’susemethodandattentions.
1.2ApplicationFieldsandRange
KaiDengWVCModemisaspecialdeviceforKaiDengcommunicationtypegenerationsystemandneedtomatchupto
KaiDeng’scommunicationmicroinverterandKaiDengPowerMonitoringSystemforuse.Ithasn’tcompatibilityforother
companyproducts.
1.3Copyrightstatement
KaiDengWVCModemisresearchanddevelopmentbyKaiDengEnergy.KaiDenghavetheownershipandpowerof
interpretationofitsEnglishlogo"KaiDeng","KDM",Chineselabel"凯登"andimageidentification ,andrelated
softwareintellectualproperty.
2KaiDengWVCModemUserManual
2.1SystemComprehensivedescription
KaiDengWVCModemistheimportantcomponentofKaiDengcommunicationpowergeneratingsystem.Accordingtothe
appliedcharacteristics,wedesignaWVCModemwhichcanmonitoringandmanageof100pcsKaiDeng’smicroinverter.
100pcsmicroinverterandoneWVCModemmakeagroup.Inthesamegroup,microinvertersandWVCModemmustbe
installedinthesamephasecircuit,andinstall2mHfilterbehindinverterandModemtopreventthecommunication
1

http://www.kaidengdg.com
interferencebetweenthedifferentgroups;WVCModemhavetwostandardinterfaces,oneisRS232standard(thedistance
RS232standardinstallationmustnotbemorethan15meters),theotherisRS485standard(RS485standardinstallation
mustnotbemorethan1200mdistance).Weneedaccordingtothesizeofthepowersystemandinstallationdistanceto
choosethestandard,werecommendationslikebelow:
1.IfthesystemhasonlyonegroupandWVCModemdistancelessthan15meters,wecanchooseRS232standard
interface;
2.Ifthesystemhavemorethan1grouporWVCModeminstallationdistanceismorethan15meters,weneedto
chooseRS485standardinterface;
Inthewholepowersystem,WVCModemsystemsimplestructureschemeslikebelow:(detailedinstallationchartplease
seeKaiDengcommunicationpowergenerationsysteminstallationstructureguide):
2.2Equipmentcomponents
KaiDengWVCModemstandardcomponentsincluding:
1. WVCModemunit(Integratedswitchingpowersupply/powerline/plug);
2

http://www.kaidengdg.com
Powerline/plug
SignallampsPowerlight
2. OneRS232serialconnections
2.3Installation
2.3.1oneWVCModem(onlyonegroup)andtheinstallationdistanceis
within15M
Whenthemicroinvertersislessthanorequalto100pcsingenerationsystem,weonlyneedtoinstalloneWVCModem.
Theinstallationisverysimple,justneedusingtheserialporttoconnecttheWVCModemandcomputer,thenpluggedin
power.Ofcourse,thefirstpremiseisyourcomputerneedsaserialport.Andthedetailsinstallationlikebelow:
1.ConnecttheserialportofthefemalecontactoflunktoWVCModemserialportandtightenthescrewonbothendsof
theconnections,showlikesbelow:
3

http://www.kaidengdg.com
Femalecontactoflunk
ConnecttoModemserialport
2.Connecttheserialportofthemalecontactoflunktocomputermainchassis’sserialportandtightenthescrewonboth
endsoftheconnections,showlikesbelow:
Connectto computermain
chassis’sserialport
Malecontactoflunk
3. Connectthepower;
4. FinishinstallationofWVCModem;
4

http://www.kaidengdg.com
2.3.2InstallationwaysofWVCModemwhichthedistanceismorethan
15M
Ifyoursystemhasmorethanonegroupofmicroinvertersandtheinstallationdistanceisfar,weneedtochooseRS485
interface.WeneedaddaconcentratorforRS232serialportbetweenWVCModemandacomputer.Thefunctionof
concentratoristomakeonecomputercanconnecttoseveralWVCModems.Belowisconcentratorofeightserialports,
justasexamplesillustrate:
WVCModemsinstallationdetailsasfollows:
1.ConnectWVCModemwithserialportlineconnectorthoughRS485serialportline;
2.ConnectRS232serialportlineofWVCModemwithPC;
3.ConnectandturnonallWVCModems;
4.WVCModemsinstallationcomplete;
2.4EquipmentinitializationandInstructions
KaiDengWVCModemwillstarttoinitializeautomaticallyafewsecondslaterafterpoweron,andindicatorlightwillbe
flashingforabout1minuteuntilinstallationcomplete.WVCModemwillautomaticallycompletepartofinstructionsand
KaiDengMonitoringSystemwillmanuallyorautomaticallycompletetherestinstructions.(ReferringtoKaiDengMonitoring
SystemInstructions)
ThesequenceofdevicesstartandoperationisthemostimportantinKaiDengGenerationSystem,anddetailsofthe
sequencepleaserefertosection2.4ofthemanual.
2.5Equipmentsoperationsequenceinstructions
ThedevicesofthenewcommunicationalPVgeneratesystemcouldworkingoodconditiontoachievethebest.Inorderto
haveKaiDengcommunicationalPVgeneratesystemoperateandworkfluently,pleasepayattentiontosystemoperation
5

http://www.kaidengdg.com
sequence.Andwrongsequencemayleadtowronganddelayeddata.Andhereisthesystemoperationsequenceas
follows:
2.6Systemcommunicationcontrolflowchart
ThedevicesofthenewcommunicationalPVgeneratesystemislikeanorganicwholethateachrelatedclosely,wehave
designedaWVCModem‐basedcommunicationalPVgeneratesystemandreliableworkingprocessofdatatransmission.
Andhereisthesystemcommunicationcontrolflowchartasfollows:
6

http://www.kaidengdg.com
Micro
Inverter Micro
Inverter Micro
Inverter Micro
Inverter Micro
Inverter Micro
Inverter
Solar
Panel Solar
Panel Solar
Panel Solar
Panel Solar
Panel Solar
Panel
WVC
Modem
Auto-Data
Collection
KaiDengMonitoringSystem
System
Database
Instructions
powerlinecommunication powerlinecommunication
Chart Of
Analysis
2.7Equipmentreboot
ItissimpletorebootKaiDengWVCModem,twowaysasfollows:
1.TurnWVCModempoweroff,thenwaitforsecondstorestorepowersupply;
2.PressRebootModembuttonofInverterMonitorSystemtorebootWVCModem.(ReferringtoKaiDengInverterMonitor
SystemManual)
Notes:
KaiDengWVCModemwillreinitializeafterrebooting,theotherrelatedworkcannotbetakenuntilrebootfinished.
IfsomeinvertermonitoringbyWVCModemchangeafterrebooting,youshouldclickDisconnectonlinebuttonon
InverterMonitorSystemandthenconnectonlinetorecognizetheinvertersthatwasremoved;
7

http://www.kaidengdg.com
2.8Disconnectsequence
AccordingtoKaiDengWVCModem’serialportconnection,pleaseDONOTdisconnectorinstallKaiDengWVCModemto
keepthehardwaresafewhenpoweron.Pleaserefertothefollowingstepstodisconnect:
1.DisconnectKaiDengWVCModempowerplug;
First you need to disconnect
the power of Modem
2.DisconnectWVCModemwithserialportline;
3.DisconnectPCwithserialportline;
4.WVCModemdisconnectedcomplete;
3Operationalenvironment&faulthandling
3.1Naturalenvironment
KaiDengWVCModemisanordinarycommunicationaltrunkingdevice,anditwouldnotworkingoodcondition,orevenbe
damagedinaverybadenvironment.Pleasenotethatnohightemperature,nohighhumidityandnoultra‐lowtemperature
workingenvironment.waterproofboxesneededforoutdoorworkingenvironment,nodirectsunlightexposureandno
extremelycoldenvironmentwithoutheatpreservationdevices.
3.2Applicationenvironment
KaiDengWVCModemtransfersdatabypowerlinescarriercommunicationtechnology,whichhassimpleinstallation,low
cost,highefficiencyandeasymaintenanceadvantagestobringourcustomersenormouseconomicbenefits.Butthereare
requirementsforarrangementofpowerlines:InvertersandWVCModeminthesamegroupshouldbeinstalledwiththe
powerlineinphase,andaddwitha2mHfilterorotherdevicestopreventsignalinterferencefromothergroups.
3.3Errorshandling
Howtodealwithfailingtoconnectdevicesandmonitoringsystemonline?
Therearereasonsaboutfailuretoconnectasthefollowingbelow,pleasekindlycheck:
8

http://www.kaidengdg.com
9
1. CheckKaiDengInverterMonitoringsysteminitializationsettings.
Theinitialnumbersandthenumberofgrouphaveadirecteffectonconnectingonline,pleasecarefullycheckthe
numbersrangeofWVCModemandtheparametersoftheinitializationsettingstokeeprelativeuniformity,andtry
again;
2. CheckWVCModeminitializationcompletedornot.
ConnectonlinewouldstartafterWVCModeminitializationcompleted.Firstitwilltakeabout1minutetoinitializea
groupofalltheinvertersafterpoweronandthebluelightwillbecontinuallyflashingandstopuntilinitialization
finished.Intheprocessing,WVCModemhasnoreactionforanyexternalcommunicationrequests;
3. Checkthebootsequenceofsystemequipments.
RightbootsequencespleaserefertoManualSection2.4;
4. Allabovecheckedandsystemonlinefailurestillexists,pleasetrytorunonlinetestingagainafterWVCModem
restartedandinitializationcompleted;
HowtodealwithoneWVCModemfailingtocommunicatecorrectlyinnormalmonitoringprocessing?
KaiDengWVCModemisdesignfor24‐hourworkandlongtimewiththousandstimesoftesting.However,WVC
Modemmaynotcommunicatecorrectlyallthetimeinthebadconditionbelow:hightemperature,moisture,signal
interferenceofpowerlinesandotherfactors.Whenitoccurtothebadsituation,pleasecutthemodempoweroffand
waitafewminutesandthenconnectthepower,theproblemcanbesolvedgenerally.Orcallourlocalafter‐service
branchforsupportandhelpaftertryingseveraltimes.
4Thankyou!
KaiDengEnergyTechnologyCo.,LTD.thanksforchoosingourproductsandtheservice!Meetingourcustomers’maximize
needsisthefinalgoaltopursue.
Thankyouverymuchforreadingthismanual,andhopeitwouldbehelpfultoyourworkandlife!Thankyou!
Other manuals for WVC Modem
2
Table of contents
Other KaiDeng Modem manuals