KAS KSS-320-FK User manual

!
kas.com.au
kas.com.au
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
For orders, enquiries and technical support please call
1300 939 669
www.KAS.com.au
!
!
!
!
!
!
!
User Guide
KSS-320-FK
Access Control

!
kas.com.au
kas.com.au
Table of Contents
Description!..........................................................................................................!1!
Features!...............................................................................................................!3!
Installation!...........................................................................................................!3!
Sounds and Lighting!...............................................................................................!3!
Rest to Factory Default!..................................................................................!3!
Technical Specifications!...............................................................................!4!
Wiring Colours!...................................................................................................!4!
Wiring Diagram!.................................................................................................!4!
Common Power Supply!..................................................................................................!4!
Special Power Supply!......................................................................................................!4!
Manager Operation!.........................................................................................!5!
Logging User Identification Numbers!.............................................................!5!
User Management with Manager Cards!.................................................!5!
Adding a Fingerprint or Keycard User!............................................................!5!
Removing Users!.......................................................................................................!5!
User Management with Remote Control!................................................!5!
Enter programming mode!....................................................................................!5!
Adding a fingerprint user-Auto generated user ID Number!...................!5!
Adding a Fingerprint/ Keycard user - Appointing specific ID number
to user!...........................................................................................................................!6!
Removing Fingerprint or Keycard User Access!..........................................!6!
User management with Manager Fingerprints!....................................!6!
Adding “Manager Add” and “Manager Delete” fingerprints!..................!6!
Adding a Fingerprint or Keycard User!............................................................!6!
Remove Fingerprint or Keycard Access!........................................................!6!
Settings!................................................................................................................!6!
Remove ALL Users!..................................................................................................!6!
Setting Facility Code!..............................................................................................!6!
Setting Lock Style and Door relay time!..........................................................!6!
Setting “Door Open” Detection!..........................................................................!7!
Setting Security Status!..........................................................................................!7!
Setting Two Devices to be contacted!.............................................................!7!
Setting Alarm signal time!.....................................................................................!7!
User Operation!..................................................................................................!7!
User to release door!...............................................................................................!7!
Switch Alarm off!.......................................................................................................!7!
Advanced Application!....................................................................................!7!
Working as a Slave Reader connecting to Controller!..............................!7!
Working as a Slave Reader connecting to Controller Wiring Diagram!..!8!
Working as Controller connecting to a Slave Reader!..............................!8!
Working as Controller connecting to a Slave Reader Wiring Diagram!..!8!
Using Two Access Controls On One Door!....................................................!8!
Using Two Access Controls On One Door Wiring Diagram!.........................!8!
Two Devices Interconnected & Interlocking- Two Doors!.......................!8!
Two Devices Interconnected & Interlocking- Two Doors Wiring
Diagram!....................................................................................................................................!9!
Description
The KAS-320-FP Fingerprint Access Control is perfect for home and/or office use,
combining fingerprint access and keycard access in the one system.
Program and delete individual cards and fingerprints, includes remote control for
easy programing.

!
kas.com.au
kas.com.au
Features
•Infrared remote control & master cards for programming!
•3000 users, includes 1000 fingerprint users and 2000 keycard users
•Card interface: EM 125KHz card
•Wiegand 26 input & output (Entry and Exit pass code needed compatibility)
•Standalone or Wiegand reader mode
•Adjustable door output time, alarm time, door open time!
•Anti-magnetic & lock output current short protect!
•2 fingerprint access controls can be connected to the 1 door
•Red, yellow and green LED display the working status
•High Security Interlocking option
Installation
Remove the back cover from the device, undoing the screw at the base of the
device
Using the back of the Access control as a template, mark the 4 holes onto the wall
for the screws and 1 hole for the cable
Fix the back cover firmly on the wall with 4 flathead screws!provided
Thread the cable through the cable hole
Attach the device face to the back cover
Sounds and Lighting
Operating Status
LED
Fingerprint
Sensor
Buzzer
Reset to factory default settings
Orange
-
2 Short Rings
Sleeping Mode
Red Glow
-
-
Stand by
Red Glow
Shine
-
Enter into programming mode
Red Glow
-
Long Ring
Wrong operation
-
Long Ring
Access granted- Open door
Green Glow
-
Long Ring
Alarm
Flashing Red
-
Alarm
Rest to Factory Default
This reset will clear all stored Manager Cards, Manager fingerprints, user
fingerprint, keycards and settings.
1. Power off device
2. Press the RESET Key on the inside of the Access Control
3. Holding the RESET Key in- Power on
4. After you hear 2 short beeps- release the key
5. LED will shine Orange- YOU NEED TO ADD THE MANAGER CARDS
6. Swipe Manager ADD Card
7. Swipe Manager DELETE
8. Factory Reset Complete

!
kas.com.au
kas.com.au
Technical Specifications
Wiring Colours
Colour
Function
Description
Orange
L+/Alarm+
Lock Positive/ Alarm Positive
Purple
L-
Lock Negative
Blue
GND
Request to Exit Button & Door Contact
Black
GND
(-) Negative Regulated Power Input
Red
+12V
(+) 12V DC Positive Regulated Power Input
Brown
D-IN
Door Contact
Yellow
OPEN
Request to Exit Button
Grey
Alarm-
Alarm Negative
Green
D0
Wiegand Output D0
White
D1
Wiegand Output D1
Wiring Diagram
Common Power Supply
Special Power Supply
!
!
!
!
!
!
!
!
!
KAS-320-FP
KAS-320-FP
KAS-320-FP
KAS-320-FP

!
kas.com.au
kas.com.au
Manager Operation
There are 3 ways to add and delete users:
•Manager Cards
•Remote Control
•Manager Fingerprints
Logging User Identification Numbers
The KAS-320 Fingerprint Access Control automatically assigns new user ID
numbers to the users. Please ensure you keep a log of your user and their ID
number. The ID numbers are needed when deleting individual users, without their
Keycard or fingerprint, this is done by remote control.
Number 1 & 2-Manager Fingerprint ID
Numbers 3 to1000- User Fingerprint
Numbers 1001 to 3000- Card Users ID
User Management with Manager Cards
Adding a Fingerprint or Keycard User
Note: When adding fingerprints please scan each fingerprint twice during which
the LED will shine red then turn green meaning the fingerprint is enrolled
successfully.
When deleting a fingerprint, just scan once.
1. Swipe Manager Add Card over face of control
2. Enter 1st users fingerprint twice Note: lift finger after first scan and
place back on scanner for second scan or Scan new users Keycard
3. To add more users - Repeat step 2
4. Once all users have been added swipe Manager Add Card over the
face of the control.
Removing Users
1. Swipe Manager Delete Card over face of control
2. Swipe users Keycards over control or place fingerprint on reader
once.
3. To remove more users - Repeat step 2
4. Once all users have been added swipe Manager Add Card over the
face of the control
5. When deleting a fingerprint user, just scan fingerprint once to
remove.
User Management with Remote Control
When managing user control with remote, you must always be in programming
mode.
Enter programming mode
1. Press “ * ” on the remote control
2. Enter Master Code (*Default Master Code 888888*)
3. Press “ # ”
Adding a fingerprint user-Auto generated user ID Number
1. Enter programing mode
2. Press “ 1 ”
3. Enter 1st users fingerprint twice Note: lift finger after first scan and
place back on scanner for second scan
4. Press “ # ”

!
kas.com.au
kas.com.au
5. To add more users - Repeat steps 3 and 4
6. Press “ # ” to exit Programing mode
!
!
!
!
!
Adding a Fingerprint/ Keycard user - Appointing specific ID number to
user
Fingerprint ID Numbers can be from 3 to 1000
Keycard ID Numbers can be from 1001 to 3000
1. Enter programing mode
2. Press “ 1 ”
3. Enter User chosen ID number and press “ # ”
4. Scan fingerprint twice or Scan Keycard
5. To add more users - Repeat steps 3 and 4
6. Press “ # ” to exit Programing mode
Removing Fingerprint or Keycard User Access
1. Enter programing mode
2. Press “ 2 ”
3. Enter fingerprint or Swipe card over control or Enter User ID No
4. To remove more users - Repeat steps 3
5. Press “ # ” exit programming mode
User management with Manager Fingerprints
Manager fingerprints must be added before using this method.
Manager fingerprints must be added using the remote control method first.
Adding “Manager Add” and “Manager Delete” fingerprints
1. Enter programing mode
2. Press “ 1 ” “ 1 ” “ # ”
3. Scan fingerprint twice - This will be the “ADD Fingerprint”
4. Press “2 ” “ # “
5. Scan another finger twice – This will be the “DELETE fingerprint”
6. Press “ * ”
Adding a Fingerprint or Keycard User
1. Scan Manager ADD fingerprint
2. Scan new user fingerprint twice or Scan Keycard
3. Scan Manager ADD fingerprint
Remove Fingerprint or Keycard Access
1. Scan Manager DELETE fingerprint
2. Scan fingerprint or Scan Keycard
3. To remove more users simply repeat step 2
4. Scan Manager DELETE fingerprint
Settings
Remove ALL Users
This will delete all fingerprint and card users including manager fingerprints.
Only Manager Cards will still be programmed
1. Enter programing mode on the remote control
2. Enter 20000
3. Press “ # ”
Setting Faculity Code
This operation might be required when the control is acting as a Wiegand reader
and connected to multi-door controllers
1. Press “ 3 ”
2. 0 to 255
3. Press “ # ”
Setting Lock Style and Door relay time
“Fail Safe” and “Fail Secure” are the setting your door will be in when there is no
power to the strike.

!
kas.com.au
kas.com.au
Factory Default is Fail Safe
The relay time relates to the how long the door will hold in the position.
1. Enter programming mode
2. Press “ 4 ” Fail Secure (locked when power is off) (Factory Default)
Press “ 5 ” Fail Safe (unlocked when power is off)
3. Enter relay time 0-99 seconds
4. Press “ # ”
Setting “Door Open” Detection
This feature will enable a buzzer alarm
Note: the door connector must be installed
•If the door is not shut properly after 1 minute
•If the door was not opened after 2 minutes when access was granted.
•If the door is forced open without access being granted
1. Enter programming mode
2. Press “ 6 ” “ 0 ” to disable function (factory default) or
Press “ 6 ” “ 1 ” to enable function
3. Press “ # ”
Setting Security Status
Normal Status- Factory default
Lock Status-If there is 10 invalid access attempts the device will lock for 10 minute
Alarm Status- If there is 10 invalid access attempts the device will sound an alarm
until a valid access attempt is entered.
1. Enter programming mode
2. Select Status
Press “ 7 ” “ 0 ”- Normal Status
Press “ 7 ” “ 1 ”- Lock on Status
Press “ 7 ” “ 2 ”- Alarm Status
3. Press “#”
Setting Two Devices to be contacted
Disabled- Factory default
1. Enter programming mode
2. Press “ 8 ” “ 0 ”- Disabled
Press “ 8 ” “ 1 ”- Enabled
3. Press “ # ”
Setting Alarm signal time
Set the length of time you want the alarm to signal if enabled.
0 to 3 minutes
1 minute- Factory default
1. Enter programming mode
2. Press “ 9 ”
3. Enter minute 1, 2 or 3
4. Press “#”
User Operation
User to release door
1. Swipe card over face of control
2. Scan fingerprint on reader
3. Open Door
Switch Alarm off
When alarm is sounding, simply enter a valid fingerprint or swipe a valid keycard
over the access control.
Advanced Application
Working as a Slave Reader connecting to Controller
The KAS-322-AC supports Wiegand output, it can be connected to a controller,
which supports Wiegand 26 input as its slave reader.
If the connector is a PC connection, the User ID can be shown in the software.
-Keycard user ID is the RF card number (8 digits)
-Fingerprint User ID is a combination of the device ID and fingerprint ID
The Fingerprint ID is set below
1. Enter programing mode
2. Press 3
3. Enter device ID- Device ID can be any number from 0-255 E.g 255

!
kas.com.au
kas.com.au
4. Fingerprint ID (set previously) E.g 3
Controller ID will be set 2550003
Working as a Slave Reader connecting to Controller Wiring Diagram
!
!
Working as Controller connecting to a Slave Reader
The KAS-322-FP supports Wiegand input. Any card reader, which supports
Wiegand 26 interface can connect to it as its slave reader, including ID and IC.
Keycards must be added at the slave reader, not the controller unless an EM card
reader is used. EM Cards can be added either by slave reader or control.
Working as Controller connecting to a Slave Reader Wiring Diagram
Using Two Access Controls On One Door
Two KAS-322-FP can be used on a single door, creating the need for users to be
verified upon entering and exiting.
The information on the 2 devices is shared so users can enroll on either device,
gaining access on both sides of the door. This doubles you current memory to
6000 users.
Note: The settings, Master code and Master fingerprints for the 2 controls must be
the same. If they are not the same the controls will act as individual controls and
you will need to add users on both controls etc.
Using Two Access Controls On One Door Wiring Diagram
Two Devices Interconnected & Interlocking- Two Doors
This high security feature is designed for areas that have 2 doors accessing the
same area eg, banks, safe rooms.
The interlocked function will work on either door. One door must be locked for the
other to unlock and open.
1. Scan Keycard or fingerprint on first access control
2. Enter first door
3. Shut first door
KAS-320-FP
KAS-320-FP
KAS-320-FP Controller 1
KAS-320-FP Controller 2

!
kas.com.au
kas.com.au
4. Scan Keycard or fingerprint on second access control
5. Enter second door
6. Shut second door
Two Devices Interconnected & Interlocking- Two Doors Wiring Diagram
KAS-320-FP Controller 1
KAS-320-FP Controller 2
Table of contents