10V DC 14V DC
500 mA
50 feet
-20°C (-4°F) 55°C (131°F)
7 7/8in 7 7/8in 3 in
Specications
Operating temperature
Electrical
Environment
Dimensions
Min Max
Width Height Depth
Cable length between ACU and Caller ID reader
Waterproof
Additional power supply required
No
No
Voltage - Reader module
Current - Reader module
Set the reader operating mode in the Net2 software to 'Paxton Reader' and the Operating mode to 'Token only'
Enter the last 8 digits of the phone number into the Net2 user record as the token number.
A phone number of 1 800 672 7298 becomes 06727298 as a Net2 token.
Adding the user's phone to a Net2 user record
Features
Carrier frequency Quad band GSM
Phones supported Caller ID enabled
LED indications
Power - 12v DC supply OK
Network - Connected to the Mobile phone network
Activity - The reader is receiving data from a mobile phone
Installation
Insert the SIM card in its holder at the top right of the unit.
A drilling template for the plastic housing is available at < http://paxton.info/1715 >
If the device is to be installed where the mobile signal may be low, the antenna should be installed externally.
Secure the antenna by:
1. Internal - Remove the peel o paper from the adhesive strip and x within the enclosure.
2. Externally - Disconnect the SMA screw connection and route the cable through any of the cabinet push-out plugs
and x to a smooth surface.
Wire the Caller ID reader color for color to a Net2 ACU reader port within a maximum cable length of 50 feet.
Belden 9540 or General Cable C0745A is recommended for all data cable wiring.
If a token reader is also installed, it is connected to the Caller ID's own reader port within a maximum cable length
to the Net2 ACU of 300 feet.
Power up the unit and conrm that the Power LED comes on. The Network LED will come on within a few minutes
once the unit is active on its GSM network.