General Information:
Exit setting mode: Enter * to exit the setting procedure, or
wait for 10 seconds
Low battery warning: When the voltage drops below 5.2V
after entering a valid code, the lock beeps for three times.
Unlocking indicator: Music sounds and motor rotate.
Locking indicator: Red Light flashing one time, and music
sounds and motor rotate.
Restore Factory Default
a. Disconnect 1pcs battery
b. Press and hold the reset button
c. While holding the reset button, reconnect the
battery
d. Until the lock beeps, release the reset button.
e. Press digit ‘1’to restore factory default or other
digit to abort reset procedure.
f. The lock must be set up again after the reset is
complete.
Warning: After restore, all existing user codes and
programming code will be erased, default
programming code will be restored , but the
enrolling of lock with gateway will not be erased.
The reset button is located below the battery holder.
(See Picture)

Page - 3 - of 8
Types to operate the lock:
User code unlock: 6 digits user code
Emergency unlock: 8 digits programming code + 9 (for
emergency)
Wireless :Mobile or PC or PAD
Manual key: Turn the override key 90 degree clockwise, then
turn the handle
Terms:
Programming code: 8 digits. The programming code puts the lock into
a programming mode. If more than 10 seconds pass in between
programming entries, the lock will return to normal operational status.
For maximum security it is necessary to change the default
Programming Code.
User code: 6 digits. User code is the normal code for day-to-day
operations.
Z-Wave: Every unlocking need be through Z-wave Controller.
Index No.*: 2 digits. For each user code. It is associate with a unique
number, we call it index No. The Index No. is auto generated by lock
and starts with 01. The highest Index No. will be 20. Total user index
is 20 that can be added to each lock. (* Please log the user code along
with its index No. for deleting reference)
Storehouse mode (Lock-back mode): For each valid entry, lock will
automatically relock back in 5 seconds.
Manufacture Default Setting:
Default programming code: 12345678
User code: Up to 20pcs,6 digits

Page - 4 - of 8
Steps to setup a new lock (please follow the order)
a. Change programming code (For example, change to
23456789)
{12345678}+{4}+{23456789}+{23456789}
b. Add user code (For example, add 123456 to the lock)
{23456789}+{1}+{123456 }+{123456}
Functions Detail
1. How to change programming code (but not delete existing users)
Function Code: 4
{ programming code}+{4}+{new programming
code}+{new programming code}
2. How to add one user code
Function Code: 1
{ programming code}+{1}+{user code}+{user code}
3. How to delete one user code with index No.
Function Code: 2
{ programming code}+{2}+{index No.}+ {#}
4. How to edit one user code with index No.
Function Code: 2
{ programming code}+{2}+{index No.}+ {6 digits new
user code}+ {6 digits new user code}
5. How to delete all user code
Function Code: 3
{programming code}+{3}+{ programming code}
6. How to enable/disable vacation mode
Function Code: 5
{programming code}+{5}, enable vacation

Page - 5 - of 8
Please be noted that the lock will not accept any user
code but programming code only in vacation mode.
{programming code}, disable vocation mode.
7. How to enable button beeps (on & off)
Function Code: 6
{programming code}+{6}, toggle beep on/off.
8. How to enable/disable passage mode
Function Code: 8
1.{programming code}+{8}, turn passage mode on/off.
2. Unlock the lock with any user code, press #until there
is a long beeps, that means passage mode set
successfully.
Please be noted that the lock would not re-lock automatic while
passage mode disable, user can re-lock it by press star key ‘*’on the
keypad manually.
9. How to enroll/unenroll lock to Z-wave network
Enroll
Put the Z-wave controller into enroll mode
Input {programming code} + {0} --- lock is into enroll mode
a. If the lock has not been enrolled with any other gateway or
have been enrolled with the same gateway, the lock sounds
long beep indicating unenroll successfully.
b. If the lock has been enrolled with other gateway, lock sounds
a short beep after 5 sec indicating enroll unsuccessfully.
Unenroll operation is needed at first.
Unenroll
Put the Z-wave controller into unenroll mode
Input {programming code } + {0 } --- lock is into unenroll mode
a. If lock has been enrolled with any other gateway, lock sounds
a long beep after 5 sec indicating unenroll successfully.

Page - 6 - of 8
b. If the lock has not been enrolled with any other gateway, lock
sounds a short beep after 50sec indicating unenroll
unsuccessfully. Unenroll operation is unnecessary.
After restore factory default, the enroll status of Z-Wave is still
effective.
Z-wave Generic Information:
Generic Device Class =
GENERIC_TYPE_ENTRY_CONTROL;
Specific Device Class =
SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK;
FLIRS setting =
APPLICATION_FREQ_LISTENING_MODE_1000ms;
Device is a security enabled Z-wave production, implements Z-Wave
Application Security Layer in accordance with Z-wave protocol. The
functionality and support command class is difference when included
as secure or no-secure node.
Device supports Anti-theft protect function in accordance with Z-
wave Anti-theft Command Class V2. Supported command class is
only Anti-theft CC when anti-theft protection enabled as Z-wave
protocol.

Page - 7 - of 8
Device Support Command Class
设备支持的命令类
Included
as no-
secure
node,
NIF
response
Included
as no-
secure
node,
Anti-
theft
protect,
NIF
response
Included
as
secure
node,
NIF
response
Included
as
secure
node,
Security
support
response
Included
as
secure
node,
Anti-
theft
protect,
NIF
response
Included
as
secure
node,
Anti-
theft
protect,
Security
support
response
ANTITHEFT
√
√
√
√
MANUFACTURER_SPECIFIC
√
√
√
√
√
VERSION
√
√
√
√
√
SECURITY
安全
√
√
√
APPLICATION_STATUS
√
√
√
ALARM
√
√
ASSOCIATION
√
√
BASIC
√
√
√
BATTERY
√
√
CONFIGURATION
√
√
DOOR_LOCK
√
DOOR_LOCK_LOGGING
√
√
NODE_NAMING
√
√
SCHEDULE_ENTRY_LOCK
√
√
TIME_PARAMETERS
√
√
USER_CODE
√
Z-Wave Command Class Specific:
COMMAND_CLASS_APPLICATION_STATUS
Device responses Application Rejected Request Command to source
node while received invalid Set command.
COMMAND_CLASS_ASSOCIATION
Device supports two(2) association groups, each group support two(2)
nodes maximum. Group ID one(1) used to send out un-socialite
operation and alarm reports. Group ID two(2) used to send out

Page - 8 - of 8
BASIC SET ON(0xFF) and OFF(0x00) command while vacation
mode is enable and disable.
COMMAND_CLASS_CONFIGURATION
Device reserves 255 bytes memory store space use for upper
application. Upper application could access the memory by
configuration command class, default setting always set to zero
(0x00) , parameter size always set to one (0x01), parameter possible
value could be from 0x00 to 0xFF which is decided by upper
application.
COMMAND_CLASS_DOOR_LOCK
Device has two(2) difference relock mode, auto-relock mode (Timed
Operation) and constant-unlock mode (Constant Operation). It can
setting by manual or Door Lock Configuration Command. Auto-
relock timeout fix in eight (8) seconds.
Device treats constant Unsecure setting of Door Lock Operation as
Unsecure with timeout while device auto-relock mode is enable.
COMMAND_CLASS_NODE_NAMING
Device report Node Name Report in ASCII with brand name and
production version inform after retrieve factory default.
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK
Device doesn’t support Daylight Saving function. It will ignore DST
offset of Schedule Entry Lock Time Offset Set Command.
Device supports Duration Hour of Schedule Entry Lock Daily
Repeating Set command from zero (0) to 168 (=7x24) maximum.
COMMAND_CLASS_USER_CODE
Device user code fix to six(6) digits. It will ignore User Code Set
Command if user code length no equal to six digits.
Z-Wave Certification No:ZC08-13100011
Table of contents
Other KAS Lock manuals