1
IMPORTANT:
Completely read these instructions and warnings prior
to installing and operating your Kasco equipment.
This portable timer is designed to CONTROL the
connected equipment only. THIS SWITCH IS NOT TO
BE USED AS A POWER DISCONNECT! Unplug The
C-20 and the equipment it controls before servicing.
Mount at least 5 ft. from open water. Refer to your
de-icer owner’s manual for additional safety and
de-icer installation/operation instructions. The C-20
is designed to operate only ONE Kasco de-icer.
INSTALLATION:
The C-20 must be mounted upright on a vertical
surface or post. For the most accurate operation
do not mount in direct sunlight. Mount close to an
outdoor receptacle to allow slack in the C-20 power
cord. Mount high enough above ground level for easy

damaging the C-20. Use corrosion resistant screws
to mount the C-20. One screw for the top hanger slot
and one for the bottom mounting tab to secure the
C-20. Insert your de-icer power cord through the hole
in the bottom of the C-20 enclosure. Allow enough
slack to prevent strain on the plug. You may also need
to provide a tether (another point to hold the cord
in place) to prevent your de-icer power cord from
slipping into the water. You can install the closure
plate provided by snapping into place from the outside
of the enclosure hole. Note: Install closure plate
with 3R (outdoor use) rating to maintain enclosure
environmental integrity.
UNDER NO CIRCUMSTANCES SHOULD
ANYONE ENTER THE WATER WHEN A UNIT
IS IN OPERATION.
SETTING THE TIMER & THERMOSTAT:
The C-20 energizes your De-icer only when both the
timer and thermostat turn on. The Indicator light will
illuminate when both timer and thermostat are on
(de-icer outlet is energized).
Timer Thermostat De-icer
OFF OFF = OFF
ON OFF = OFF
OFF ON = OFF
ON ON = ON
TIMER SETTING:
1. Push each tripper to the outer ring for every 15

and effective De-Icing, do not set the timer in
segments of less than one hour activation time. (Set
4 trippers on together for 1 hour minimum.)
2. Turn timer dial clockwise until correct time-of-day
is aligned with “TIME NOW” arrow.
3. Set AUTO/ON switch to AUTO for automatic timer
control.
Note: Setting the timer switch to ON will allow the
de-icer to operate by the thermostat only (timer output
is always on).
THERMOSTAT SETTING:
Simply set the thermostat dial to the temperature you
want the de-icer to turn on. (Remember the timer must
also be set to ON or AUTO for the de-icer to energize.)
The thermostat has a 6°F ON/OFF differential. This
differential helps prevent short cycling of the de-icer.
Set the thermostat to the desired ON temperature and it
will shut off approximately 6°F above the ON setting.
Note: The C-20 control must acclimate to the outdoor
ambient temperature for proper operation. Allow
at least 1 hour for the C-20 to adjust to ambient
temperature.
OPERATING RECOMMENDATIONS:
Use the following tips and suggestions to assist in
customizing your settings for local conditions.
• De-icers will create small localized currents the
longer they run. Fewer and longer operation cycles
will prove to be more effective than more frequent
and shorter operating cycles.
• Fresh water freezes at 32°F, salt water at 28°F, and
Kasco C-20 Portable Timer & Temperature Control
2
and cycle the De-icer on temperature.
• To bypass the thermostat and operate only on
time, set the thermostat to its highest temperature
setting. Use the timer settings to cycle the de-icer.
Note: If the ambient temperature rises above the
thermostat highest setting, it will shut off the
de-icer.
• When not in use (summer time), store the C-20
indoors away from salt air. This will help extend
the life of the C-20 controller.
• Operate with the door closed to keep salt air away
from internal components.
• Mount the C-20 out of direct sun light. This will
prevent excessive internal heating of the controller.
Internal heating may prevent the C-20 from
operating correctly.
WARRANTY:
Kasco Marine, Inc. warrants the C-20 to be free from
defects in material or workmanship under normal use
and service. The Kasco Marine, Inc. obligation under
this warranty is limited to replacing free of charge
any defective part within two (2) years from date of
purchase. Customer shall pay all shipping charges.
THIS WARRANTY IS IN LIEU OF ANY OTHER
WARRANTIES EXPRESSED OR IMPLIED, AND
ANY OTHER OBLIGATION OR LIABILITY
WHATEVER ON THE PART OF KASCO MARINE,
INC. AND IN NO EVENT SHALL KASCO
MARINE, INC. BE LIABLE FOR ANY SPECIAL
OR CONSEQUENTIAL DAMAGES.
No warranty registration is required, only original
purchase receipt is needed for limited warranty
coverage. Warranty is void: If the C-20 is damaged by

The Industry Leader in
Ice Control Engineering.
Kasco Marine, Inc.
800 Deere Rd.
Prescott, WI 54021
PH (715) 262-4488
FAX (715) 262-4487
www.kascomarine.com
www.de-icer.com
brackish water will freeze somewhere in between.
Setting the thermostat a couple degrees below the
freezing point can minimize unneeded operation
time.
• Daily observation is required for all de-icing
installations. Adjust operating times based on
when you can observe the operation. This will help
you check the de-icer is operating properly.
• Several factors can increase freeze rate. Such
as, wind, snow, and colder temperatures. When
picking operation times, set the de-icer to operate
more when conditions promote quicker freezing.
• 
Remember to observe your de-icer installation
and be prepared to adjust your settings of the
C-20. Thermostat tolerance may also need to
be adjusted for. The actual ON/OFF point of the
thermostat may be -/+ 2.7°F of the actual ambient
temperature.
• Operating with fewer, longer cycles will provide

example of setting the timer over a 24 hour period.
The 4 ON cycles below allow for more operating
time during dark hours and less during daytime
hours. (This is suggested due to increased freezing
rate at night).
Cycle Time Length
ON 7:00 a.m. - 9:00 a.m. 2 hr
OFF 9:00 a.m. - 1:00 p.m. 4 hr
ON 1:00 p.m. - 3:00 p.m. 2 hr
OFF 3:00 p.m. - 7:00 p.m. 4 hr
ON 7:00 p.m. - 10:00 p.m. 3 hr
OFF 10:00 p.m. - 12:00 a.m. 2 hr
ON 12:00 a.m. - 5:00 a.m. 5 hr
OFF 5:00 a.m. - 7:00 a.m. 2 hr
This sample would allow the de-icer to operate a
maximum of 12 hours in a 24 hour period. During
the ON cycles, the thermostat would determine if
the de-icer operates based on its dial setting. Actual
settings and durations of run time will depend on your
installation requirements and regional demands for
de-icing.
• To bypass the timer and operate only on
temperature, set the timer ON/AUTO switch to
 #824401 Rev. 02/12/15

Other manuals for C20

2

Popular Temperature Controllers manuals by other brands

Ogden ETR-901 instruction manual

Ogden

Ogden ETR-901 instruction manual

Yolink YS8006-UC Installation manual & users guide

Yolink

Yolink YS8006-UC Installation manual & users guide

Vaisala CARBOCAP GMW86P user guide

Vaisala

Vaisala CARBOCAP GMW86P user guide

Omron E5ZN Series brochure

Omron

Omron E5ZN Series brochure

ELEKTRA ELR-10 installation manual

ELEKTRA

ELEKTRA ELR-10 installation manual

ATIM TM2D-HP Series user guide

ATIM

ATIM TM2D-HP Series user guide

Viessmann VITOTROL 100 Installation and service instructions

Viessmann

Viessmann VITOTROL 100 Installation and service instructions

Aqua Medic T controller CC Operation manual

Aqua Medic

Aqua Medic T controller CC Operation manual

NTI ENVIROMUX-STSP-SL-7 installation manual

NTI

NTI ENVIROMUX-STSP-SL-7 installation manual

Conotec FOX-2000TT quick guide

Conotec

Conotec FOX-2000TT quick guide

Innovative instruments i-therm AI-5441 User's operating manual

Innovative instruments

Innovative instruments i-therm AI-5441 User's operating manual

Komfovent C5.1 Electrical installation and Operation Manual

Komfovent

Komfovent C5.1 Electrical installation and Operation Manual

GIC PR-69 Series instructions

GIC

GIC PR-69 Series instructions

Vector TLC-BCR-T manual

Vector

Vector TLC-BCR-T manual

Siemens REV23 user guide

Siemens

Siemens REV23 user guide

dixell XH460L operating instructions

dixell

dixell XH460L operating instructions

Automationdirect.com SOLO SLM Series user manual

Automationdirect.com

Automationdirect.com SOLO SLM Series user manual

Uniflair UST500 instruction manual

Uniflair

Uniflair UST500 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.