Keysight Ixia XG12 User manual

XG12 Chassis
Release 9.10
Assembly Guide
Document version: 202008071846+05:30

Notices
Copyright Notice
© Keysight Technologies 2020
No part of this document may
be reproduced in any form or by
any means (including electronic
storage and retrieval or
translation into a foreign
language) without prior
agreement and written consent
from Keysight Technologies,
Inc. as governed by United
States and international
copyright laws.
Warranty
The material contained in this
document is provided “as is,”
and is subject to being
changed, without notice, in
future editions. Further, to the
maximum extent permitted by
applicable law, Keysight
disclaims all warranties, either
express or implied, with regard
to this manual and any
information contained herein,
including but not limited to the
implied warranties of
merchantability and fitness for
a particular purpose. Keysight
shall not be liable for errors or
for incidental or consequential
damages in connection with the
furnishing, use, or performance
of this document or of any
information contained herein.
Should Keysight and the user
have a separate written
agreement with warranty terms
covering the material in this
document that conflict with
these terms, the warranty
terms in the separate
agreement shall control.
Technology Licenses
The hardware and/or software
described in this document are
furnished under a license and
may be used or copied only in
accordance with the terms of
such license.
U.S. Government Rights
The Software is "commercial
computer software," as defined
by Federal Acquisition
Regulation ("FAR") 2.101.
Pursuant to FAR 12.212 and
27.405-3 and Department of
Defense FAR Supplement
("DFARS") 227.7202, the U.S.
government acquires
commercial computer software
under the same terms by which
the software is customarily
provided to the public.
Accordingly, Keysight provides
the Software to U.S.
government customers under
its standard commercial
license, which is embodied in
its End User License Agreement
(EULA), a copy of which can be
found at
http://www.keysight.com/find
/sweula or
https://support.ixiacom.com/s
upport-services/warranty-
license-agreements. The
license set forth in the EULA
represents the exclusive
authority by which the U.S.
government may use, modify,
distribute, or disclose the
Software. The EULA and the
license set forth therein, does
not require or permit, among
other things, that Keysight: (1)
Furnish technical information
related to commercial computer
software or commercial
computer software
documentation that is not
customarily provided to the
public; or (2) Relinquish to, or
otherwise provide, the
government rights in excess of
these rights customarily
provided to the public to use,
modify, reproduce, release,
perform, display, or disclose
commercial computer software
or commercial computer
software documentation. No
additional government
requirements beyond those set
forth in the EULA shall apply,
except to the extent that those
terms, rights, or licenses are
explicitly required from all
providers of commercial
computer software pursuant to
the FAR and the DFARS and are
set forth specifically in writing
elsewhere in the EULA.
Keysight shall be under no
obligation to update, revise or
otherwise modify the Software.
With respect to any technical
data as defined by FAR 2.101,
pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102,
the U.S. government acquires
no greater than Limited Rights
as defined in FAR 27.401 or
DFAR 227.7103-5 (c), as
applicable in any technical
data. 52.227-14 (June 1987) or
DFAR 252.227-7015 (b)(2)
(November 1995), as
applicable in any technical
data.
Safety Information
Do not proceed
beyond a hazard
notice until the
indicated conditions
are fully understood and met.
– ii –

ACAUTION notice denotes a
hazardous situation that, if not
avoided, could result in minor
or moderate injury.
AWARNING notice denotes a
hazardous situation that, if not
avoided, could result in death
or serious injury.
– iii –

Contact Us
Ixia headquarters
26601 West Agoura Road
Calabasas, California 91302
+1877 367 4942 – Toll-free North America
+1 818 871 1800 – Outside North America
+1.818.871.1805 – Fax
www.ixiacom.com/contact/info
Support
Global Support +1 818 595 2599 support@ixiacom.com
Regional and local support contacts:
APAC Support +91 80 4939 6410 support@ixiacom.com
Australia +61-742434942 support@ixiacom.com
EMEA Support +40 21 301 5699 support-emea@ixiacom.com
Greater ChinaRegion +400 898 0598 support-china@ixiacom.com
Hong Kong +852-30084465 support@ixiacom.com
India Office +91 80 4939 6410 support-india@ixiacom.com
Japan Head Office +81 3 5326 1980 support-japan@ixiacom.com
Korea Office +82 2 3461 0095 support-korea@ixiacom.com
Singapore Office +65-6215-7700 support@ixiacom.com
Taiwan (local toll-free number) 00801856991 support@ixiacom.com
– iv –

This page intentionally left blank.
– v –

CONTENTS
Chapter 1 Introduction 1
Chapter 2 XG12 Chassis modules 3
Chapter 3 Install XG12 Chassis 5
XG12 Chassis installation precautions 6
Un-pack and mount the chassis 7
Remove and insert processor module 8
Remove and insert power supply module 9
Power cords 11
Remove and insert fan module 12
Chapter 4 Log on to XG12 Chassis 13
INDEX 15
– vi –

This page intentionally left blank.
– vii –

CHAPTER 1Introduction
This document describes how to install the XG12 chassis and its various modules.
The XG12 Chassis is the next generation high performance platform capable of supporting all XM form
factor load modules, including full chassis configurations of the Xcellon-Flex load modules. It is a 12-
slot chassis with increased total power capacity available for all load modules and front-to-back airflow
delivery along with increased bandwidth from the CPU to the load modules.
The chassis provides improved modularity and access to the major components to reduce downtime of
a failed chassis and to reduce the probability of needing to remove a failed chassis from the test
environment.
Chapter 1 Introduction
–1–

This page intentionally left blank.
–2–

CHAPTER 2XG12 Chassis modules
The modules that make up the chassis are as follows:
lChassis Frame Module
lChassis Fan Module
lChassis Power Supply Module
lChassis Processor Module
The Processor Module is plugged into the front of the chassis. The power supplies and fans are
accessible from the rear of the chassis. Each of the modular components is capable of being removed
in the field and replaced with minimum downtime.
Chapter 2 XG12 Chassis modules
–3–

This page intentionally left blank.
–4–

CHAPTER 3Install XG12 Chassis
This section explains the notational and typographical conventions used in this documentation, and
provides a list of related documentation.
Section contents:
XG12 Chassis installation precautions 6
Un-pack and mount the chassis 7
Remove and insert processor module 8
Remove and insert power supply module 9
Power cords 11
Remove and insert fan module 12
Chapter 3 Install XG12 Chassis
–5–

XG12 Chassis installation precautions
The following precautions should be followed while installing the XG12 chassis:
lThe chassis should be installed in the rack before installing the power supply module, fan module
and load modules, thereby reducing the weight of the chassis.
lThe two lower bolts used to secure the chassis to a rack can be used to hold the chassis frame in
place while securing all of the other bolts.
lSecure the chassis to rack face with all six bolts.
lFully depress power supply clamps when installing power supply module.
lSecure the power supply module thumb bolt when installing power supply module.
lInstall the rear power supply cover before applying AC power. After removing or installing this
cover, ensure that the thumbscrews are tightened down with a 'Flat Blade' screwdriver.
lDo not use the chassis without installing the Fan module.
lDo not use the chassis without installing the Processor module.
lDo not leave unused slots open. Use the filler panels to cover the un-used slots.
lDo not block the front air intake.
lA minimum air flow clearance of 12 inches is required. 24 inches of air flow clearance is preferred
at the rear of the chassis.
lOperator intervention may be required to power cycle the XG12 chassis or restart a software
program in the event the XG12 chassis operation is upset or stopped by electrostatic discharge.
Chapter 3 Install XG12 Chassis
–6–

Un-pack and mount the chassis
1. Cut tape and open the carton.
2. Remove accessories box, top foam inserts, and side packing inserts.
3. Lift chassis out of the carton.
4. Remove power supply cover and keep it aside.
5. Remove the plastic wrapping.
6. Insert the lowermost screws on the rack.
7. Slide the chassis into the rack so that the lower screw notches of the chassis rests on the screws
on the rack.
8. Insert the other screws and secure the chassis to the rack by tightening the screws.
Chapter 3 Install XG12 Chassis
–7–

WARNING:The weight of the chassis components are as follows:
lEmpty chassis with air baffles = 70 lbs
lEmpty chassis without air baffles = 48 lbs
l3 power cords = 6 lbs
lPower supply assembly = 29 lbs
lFan Assembly = 10 lbs
lCPU card = 4 lbs
Do not attempt to lift the fully assembled chassis.
Remove and insert processor module
To remove the processor module:
1. Unfasten the screws.
2. Pinch the clips and then pull outwards.
Chapter 3 Install XG12 Chassis
–8–

To insert the processor module:
1. Slide the module into the slot.
2. Pinch on the clips and push them in.
3. Fasten the screws.
Remove and insert power supply module
The power supply module is accessible after removing the rear cover.
To remove the rear cover, unfasten the four screws around the cover and pull out the cover.
To remove the power supply module:
Chapter 3 Install XG12 Chassis
–9–

1. Loosen the thumbscrew in the upper left corner of the power supply module.
2. Pull the power clamp handles.
3. Hold the two handles provided on the power supply module and pull them.
To remove the individual power supplies,
1. Hold the handle on the power supply
2. Pull the clip inwards and then pull the handle out.
To insert the individual power supplies, slide the power supply in until you hear the clicking sound of
the clip.
To insert the power supply module:
1. Place the power supply module on the rails.
2. Push the power supply module inwards.
Chapter 3 Install XG12 Chassis
– 10 –

3. Push the power clamp handles in to lock the busbars in place.
4. To hold the power module in place, tighten the thumbscrew at the upper left corner of the power
supply module.
5. Replace the rear cover and fasten it with the screws.
Power cords
The XG12 chassis is CE marked and UL™ certified when using the 200-240VAC power cords supplied
with the chassis. However, these certifications for the chassis safety approvals are only valid when the
unit is operating from all three 200-240VAC main power sources.
Chapter 3 Install XG12 Chassis
– 11 –

Refer to the Ixia Platform Reference Manual at https://support.ixiacom.com/user-guide/ixos for more
details.
Remove and insert fan module
The fan module is located on the rear side of the chassis.
To remove the fan module:
1. Unfasten the four screws that are present on the edges of the fan module.
2. Pull the module outwards.
To install the fan module:
1. Push the rubber grommets over the metal standoff on the chassis.
2. Fasten the four screws tightly.
Chapter 3 Install XG12 Chassis
– 12 –

CHAPTER 4Log on to XG12 Chassis
The Username for an XG12 (Windows 7) remote desktop session is ixia and the password is the CPU
module serial number found on the sticker located in front of the CPU module.
The two network ports on the CPU module are configured by default for DHCP.
Note: The chassis windows wallpaper is not displayed. So the credentials are required to log on.
Chapter 4 Log on to XG12 Chassis
– 13 –
Table of contents
Other Keysight Chassis manuals

Keysight
Keysight PXIe M9018B User guide

Keysight
Keysight ixia XGS12 User manual

Keysight
Keysight M9514A User guide

Keysight
Keysight E8401A Troubleshooting guide

Keysight
Keysight M9506A User manual

Keysight
Keysight M9514A Operating instructions

Keysight
Keysight PXIe M9010A User guide

Keysight
Keysight M9018A User manual

Keysight
Keysight Ixia XGS2 User manual

Keysight
Keysight Ixia IxOS XGS2 Series User manual