Keysight M9710A User guide

Startup
Guide
Keysight M9710A
AXIe High-Speed Digitizer
4 channels, 10-bit, up to 10 GS/s,
DC up to 2.5 GHz bandwidth

Notices
Copyright Notice
© Keysight Technologies 2016
No part of this manual may be
reproduced in any form or by any
means (including electronic storage
and retrieval or translation into a foreign
language) without prior agreement and
written consent from Keysight
Technologies, Inc. as governed by
United States and international
copyright laws.
Manual Part Number
M9710-90001
Published By
Keysight Technologies
Chemin des Aulx, 12
1228 Plan-Les-Ouates
Switzerland
Edition
Edition 1, January, 2016
Printed In USA
Regulatory Compliance
This product has been designed and
tested in accordance with accepted
industry standards, and has been
supplied in a safe condition. To review
the Declaration of Conformity, go to
http://www.keysight.com/go/conformity.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,” AND
IS SUBJECT TO BEING CHANGED,
WITHOUT NOTICE, IN FUTURE
EDITIONS. FURTHER, TO THE
MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT
DISCLAIMS ALL WARRANTIES, EITHER
EXPRESS OR IMPLIED, WITH REGARD
TO THIS MANUAL AND ANY
INFORMATION CONTAINED HEREIN,
INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS
OR FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES IN
CONNECTION WITH THE
FURNISHING, USE, OR
PERFORMANCE OF THIS DOCUMENT
OR OF ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND THE
USER HAVE A SEPARATE WRITTEN
AGREEMENT WITH WARRANTY TERMS
COVERING THE MATERIAL IN THIS
DOCUMENT THAT CONFLICT WITH
THESE TERMS, THE WARRANTY
TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.
KEYSIGHT TECHNOLOGIES DOES NOT
WARRANT THIRD-PARTY SYSTEM-
LEVEL (COMBINATION OF CHASSIS,
CONTROLLERS, MODULES, ETC.)
PERFORMANCE, SAFETY, OR
REGULATORY COMPLIANCE, UNLESS
SPECIFICALLY STATED.
Technology Licenses
The hardware and/or software
described in this document are
furnished under a license and may be
used or copied only in accordance with
the terms of such license.
U.S. Government Rights
The Software is “commercial computer
software,” as defined by Federal
Acquisition Regulation (“FAR”) 2.101.
Pursuant to FAR 12.212 and 27.405-3
and Department of Defense FAR
Supplement (“DFARS”) 227.7202, the
U.S. government acquires commercial
computer software under the same
terms by which the software is
customarily provided to the public.
Accordingly, Keysight provides the
Software to U.S. government customers
under its standard commercial license,
which is embodied in its End User
License Agreement (EULA), a copy of
which can be found at
http://www.keysight.com/find/sweula. The
license set forth in the EULA represents
the exclusive authority by which the
U.S. government may use, modify,
distribute, or disclose the Software. The
EULA and the license set forth therein,
does not require or permit, among other
things, that Keysight: (1) Furnish
technical information related to
commercial computer software or
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish
to, or otherwise provide, the
government rights in excess of these
rights customarily provided to the
public to use, modify, reproduce,
release, perform, display, or disclose
commercial computer software or
commercial computer software
documentation. No additional
government requirements beyond
those set forth in the EULA shall apply,
except to the extent that those terms,
rights, or licenses are explicitly required
from all providers of commercial
computer software pursuant to the FAR
and the DFARS and are set forth
specifically in writing elsewhere in the
EULA. Keysight shall be under no
obligation to update, revise or otherwise
modify the Software. With respect to
any technical data as defined by FAR
2.101, pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102, the U.S.
government acquires no greater than
Limited Rights as defined in FAR 27.401
or DFAR 227.7103-5 (c), as applicable in
any technical data.
Safety Notices
A CAUTION notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that, if
not correctly performed or adhered to,
could result in damage to the product
or loss of important data. Do not
proceed beyond a CAUTION notice until
the indicated conditions are fully
understood and met.
A WARNING notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that, if
not correctly performed or adhered to,
could result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated conditions are
fully understood and met.
The following safety precautions should
be observed before using this product
and any associated instrumentation.
This product is intended for use by
qualified personnel who recognize
shock hazards and are familiar with the
safety precautions required to avoid
2

possible injury. Read and follow all
installation, operation, and
maintenance information carefully
before using the product.
If this product is not used as specified,
the protection provided by the
equipment could be impaired. This
product must be used in a normal
condition (in which all means for
protection are intact) only.
The types of product users are:
Responsible body is the individual or
group responsible for the use and main-
tenance of equipment, for ensuring that
the equipment is operated within its spe-
cifications and operating limits, and for
ensuring operators are adequately trained.
Operators use the product for its intended
function. They must be trained in electrical
safety procedures and proper use of the
instrument. They must be protected from
electric shock and contact with hazardous
live circuits.
Maintenance personnel perform routine
procedures on the product to keep it oper-
ating properly (for example, setting the line
voltage or replacing consumable mater-
ials). Maintenance procedures are
described in the user documentation. The
procedures explicitly state if the operator
may perform them. Otherwise, they should
be performed only by service personnel.
Service personnel are trained to work on
live circuits, perform safe installations, and
repair products. Only properly trained ser-
vice personnel may perform installation
and service procedures.
Operator is responsible to maintain safe
operating conditions. To ensure safe
operating conditions, modules should
not be operated beyond the full
temperature range specified in the
Environmental and physical
specification. Exceeding safe operating
conditions can result in shorter
lifespans, improper module
performance and user safety issues.
When the modules are in use and
operation within the specified full
temperature range is not maintained,
module surface temperatures may
exceed safe handling conditions which
can cause discomfort or burns if
touched. In the event of a module
exceeding the full temperature range,
always allow the module to cool before
touching or removing modules from
chassis.
Keysight products are designed for use
with electrical signals that are rated
Measurement Category I and
Measurement Category II, as described
in the International Electrotechnical
Commission (IEC) Standard IEC 60664.
Most measurement, control, and data
I/O signals are Measurement Category I
and must not be directly connected to
mains voltage or to voltage sources with
high transient over-voltages.
Measurement Category II connections
require protection for high transient
over-voltages often associated with
local AC mains connections. Assume all
measurement, control, and data I/O
connections are for connection to
Category I sources unless otherwise
marked or described in the user
documentation.
Exercise extreme caution when a shock
hazard is present. Lethal voltage may
be present on cable connector jacks or
test fixtures. The American National
Standards Institute (ANSI) states that a
shock hazard exists when voltage levels
greater than 30V RMS, 42.4V peak, or
60VDC are present. A good safety
practice is to expect that hazardous
voltage is present in any unknown
circuit before measuring.
Operators of this product must be
protected from electric shock at all
times. The responsible body must
ensure that operators are prevented
access and/or insulated from every
connection point. In some cases,
connections must be exposed to
potential human contact. Product
operators in these circumstances must
be trained to protect themselves from
the risk of electric shock. If the circuit is
capable of operating at or above 1000V,
no conductive part of the circuit may be
exposed.
Do not connect switching cards directly
to unlimited power circuits. They are
intended to be used with impedance-
limited sources. NEVER connect
switching cards directly to AC mains.
When connecting sources to switching
cards, install protective devices to limit
fault current and voltage to the card.
Before operating an instrument, ensure
that the line cord is connected to a
properly-grounded power receptacle.
Inspect the connecting cables, test
leads, and jumpers for possible wear,
cracks, or breaks before each use.
When installing equipment where
access to the main power cord is
restricted, such as rack mounting, a
separate main input power disconnect
device must be provided in close
proximity to the equipment and within
easy reach of the operator.
For maximum safety, do not touch the
product, test cables, or any other
instruments while power is applied to
the circuit under test. ALWAYS remove
power from the entire test system and
discharge any capacitors before:
connecting or disconnecting cables or
jumpers, installing or removing
switching cards, or making internal
changes, such as installing or removing
jumpers.
Do not touch any object that could
provide a current path to the common
side of the circuit under test or power
line (earth) ground. Always make
measurements with dry hands while
standing on a dry, insulated surface
capable of withstanding the voltage
being measured.
The instrument and accessories must
be used in accordance with its
specifications and operating
instructions, or the safety of the
equipment may be impaired.
Do not exceed the maximum signal
levels of the instruments and
accessories, as defined in the
specifications and operating
information, and as shown on the
instrument or test fixture panels, or
switching card.
When fuses are used in a product,
replace with the same type and rating
for continued protection against fire
hazard.
Chassis connections must only be used
as shield connections for measuring
3

circuits, NOT as safety earth ground
connections.
If you are using a test fixture, keep the
lid closed while power is applied to the
device under test. Safe operation
requires the use of a lid interlock.
Instrumentation and accessories shall
not be connected to humans.
Before performing any maintenance,
disconnect the line cord and all test
cables.
To maintain protection from electric
shock and fire, replacement
components in mains circuits –
including the power transformer, test
leads, and input jacks – must be
purchased from Keysight. Standard
fuses with applicable national safety
approvals may be used if the rating and
type are the same. Other components
that are not safety-related may be
purchased from other suppliers as long
as they are equivalent to the original
component (note that selected parts
should be purchased only through
Keysight to maintain accuracy and
functionality of the product). If you are
unsure about the applicability of a
replacement component, call an
Keysight office for information.
No operator serviceable parts inside.
Refer servicing to qualified personnel.
To prevent electrical shock do not
remove covers. For continued
protection against fire hazard, replace
fuse with same type and rating.
PRODUCT MARKINGS:
The CE mark is a registered trademark
of the European Community.
Australian Communication and Media
Authority mark to indicate regulatory
compliance as a registered supplier.
This symbol indicates product
compliance with the Canadian
Interference-Causing Equipment
Standard (ICES-001). It also identifies
the product is an Industrial Scientific
and Medical Group 1 Class A product
(CISPR 11, Clause 4).
South Korean Class A EMC Declaration.
This equipment is Class A suitable for
professional use and is for use in
electromagnetic environments outside
of the home. A급기기( 업무용 방송통
신기자재 )이 기기는 업무용 (A 급)전 자
파적합기기로서 판 매자 또는 사용자는
이점을주의하시기바라며,가정외의
지역에서 사용하는 것을 목적으 로 합니
다.
This product complies with the WEEE
Directive marketing requirement. The
affixed product label (above) indicates
that you must not discard this
electrical/electronic product in
domestic household waste. Product
Category: With reference to the
equipment types in the WEEE directive
Annex 1, this product is classified as
“Monitoring and Control
instrumentation” product. Do not
dispose in domestic household waste.
To return unwanted products, contact
your local Keysight office, or for more
information see
http://about.keysight.com/en/companyinfo/e
nvironment/takeback.shtml.
This symbol indicates the instrument is
sensitive to electrostatic discharge
(ESD). ESD can damage the highly
sensitive components in your
instrument. ESD damage is most likely
to occur as the module is being
installed or when cables are connected
or disconnected. Protect the circuits
from ESD damage by wearing a
grounding strap that provides a high
resistance path to ground. Alternatively,
ground yourself to discharge any built-
up static charge by touching the outer
shell of any grounded instrument
chassis before touching the port
connectors.
This symbol on an instrument means
caution, risk of danger. You should refer
to the operating instructions located in
the user documentation in all cases
where the symbol is marked on the
instrument.
This symbol indicates the time period
during which no hazardous or toxic
substance elements are expected to
leak or deteriorate during normal use.
Forty years is the expected useful life of
the product.
This symbol denotes a hot surface. The
side cover of the module will be hot
after use and should be allowed to cool
for several minutes.
CLEANING PRECAUTIONS:
To prevent electrical shock, disconnect
the Keysight Technologies instrument
from mains before cleaning. Use a dry
cloth or one slightly dampened with
water to clean the external case parts.
Do not attempt to clean internally. To
clean the connectors, use alcohol in a
well-ventilated area. Allow all residual
alcohol moisture to evaporate, and the
fumes to dissipate prior to energizing
the instrument.
4

5
Contents
Documentation Map 6
M9710A AXIe High-Speed Digitizer Introduction 7
Step 1: Unpack and Inspect the Module 9
Electrostatic Discharge (ESD) Precautions 9
Inspect for Damage 9
Return a Module for Service 10
Step 2: Verify M9710A Shipment Contents 11
Step 3: Install the Software 12
System Requirements 12
Hardware Requirements 13
Install the Software 13
Keysight IO Libraries Suite (IOLS) 13
Instrument Software 13
Step 4: Install the Module 15
M9710A Front Panel Features 17
Front Panel Connectors 17
Front Panel LEDs 18
Step 5: Verify Operation of the M9710A Module 19
Keysight Connection Expert 19
Driver Graphical Interface: MD2 Soft Front Panel 20
Perform a Verification of the M9710A (optional) 21
Requirements for Verification 21
Required Hardware 21
Operational Verification Procedure 21

Documentation Map
Documentation Map
6 Keysight M9710A Startup Guide

M9710A AXIe High-Speed Digitizer Introduction
Keysight M9710A Startup Guide 7
M9710A AXIe High-Speed Digitizer Introduction
The scope of this Startup Guide is to detail the processes of receiving and installing
the Keysight M9710A AXIe High-Speed Digitizer, installing the required software, and
verifying basic module operation.
If you have any questions after reviewing this information, please contact your local
Keysight representative or contact us through our website at
www.keysight.com/find/contactus.
Related Documentation
If you have run the Keysight MD2 software installer on your PC, this Startup Guide
and the related product documentation listed below have been installed to your hard
drive.
These documents are also available for download from the Keysight Technologies
website www.keysight.com/find/M9710A.
Document Description and location
Startup Guide Includes procedures to help you to unpack, inspect, install (software and hardware), perform
instrument connections, verify operation, and troubleshoot your product. Startup Menu >
Keysight MD2 Digitizer > Startup Guides
User Manual Provides in-depth information and reference material specific to your digitizer product. Star-
tup Menu > Keysight MD2 Digitizer > Users Manuals
Data Sheet In addition to a detailed product introduction, the data sheet supplies full product spe-
cifications. Startup Menu > Keysight MD2 Digitizer > Data Sheets
Soft Front Panel (help system) Provides information on the use of the driver Soft Front Panel.
Startup Menu > Keysight MD2 Digitizer > MD2 SFPHelp
IVI Driver reference (help sys-
tem)
Provides detailed documentation of the IVI-COM and IVI-C driver API functions, as well as
information to help you get started with using the IVI drivers in your application devel-
opment environment. Startup Menu > Keysight MD2 Digitizer > AgMD2 IVI Driver Help
LabVIEW Driver reference (help
system)
Provides detailed documentation of the LabVIEW G driver API functions.
Startup Menu > Keysight MD2 Digitizer > LabView Help

M9710A AXIe High-Speed Digitizer Introduction
Follow the Startup Sequence
This Start-Up Guide is intended to lead the user through the four steps of product
installation as summarized in the diagram below. An optional fifth step shows how to
perform an operational verification of the M9710A AXIe High-Speed Digitizer.
Step 1: Unpack and Inspect
Step 2: Verify Shipment
Step 3: Install Drivers and Software
Step 4: Install Modules
Closely follow the startup process flow in this document. Deviating from the
sequence can cause unpredictable system behavior, damage your system, and
may cause personal injury.
8 Keysight M9710A Startup Guide

Step 1: Unpack and Inspect the Module
Keysight M9710A Startup Guide 9
Step 1: Unpack and Inspect the Module
The module is shipped in materials which prevent damage from static. The
module should only be removed from the packaging in an anti-static area
ensuring that correct anti-static precautions are taken. Store all modules in anti-
static envelopes when not in use.
Electrostatic Discharge (ESD) Precautions
Electrostatic discharge (ESD) can
damage or destroy electronic
components. Use a static-safe work
station to perform all work on electronic
assemblies. The figure (left) shows a
static-safe work station using two types
of ESD protection: conductive table-
mat and wrist-strap combination, and
conductive floor-mat and heel-strap
combination. Both types, when used
together, provide a significant level of
ESD protection. Of the two, only the
table-mat and wrist-strap combination
provides adequate ESD protection when used alone. To ensure user safety, the
static-safe accessories must provide at least 1MΩ of isolation from ground.
DONOT use these techniques for a static-safe work station when working on
circuitry with a voltage potential greater than 500volts.
Inspect for Damage
After unpacking a module, inspect it for any shipping damage. Report any damage to
the shipping agent immediately, as such damage is not covered by the warranty (see
warranty information at beginning of this document).
To avoid damage when handling a module, do not touch any exposed
components or connector pins.
See http://www.keysight.com/find/tips for information on preventing damage to
your Keysight equipment.

Step 1: Unpack and Inspect the Module
Return a Module for Service
Should it become necessary to return a module for repair or service, follow the steps
below:
1. Review the warranty information shipped with your product.
2. Contact Keysight to obtain a Return Material Authorization (RMA) and return
address. For assistance finding Keysight contact information, go to
www.keysight.com/find/assist (worldwide contact information for repair and
service).
3. Write the following information on a tag and attach it to the malfunctioning equip-
ment:
Name and address of owner. A P.O. box is not acceptable as a return address.
Product model number (for example, M9710A).
Product serial number. The serial number label is located on the top cover of the
module. The serial number can also be read from the Soft Front Panel interface,
but only after the hardware is installed.
Description of failure or service required.
4. Pack the module in its original ESD bag and packing carton. If the original carton is
not available, use bubble wrap or packing peanuts and place the instrument in a
sealed container and mark the container “FRAGILE”.
5. On the shipping label, write ATTENTION REPAIR DEPARTMENT and the RMA num-
ber.
If any correspondence is required, refer to the product by serial number and
model number.
10 Keysight M9710A Startup Guide

Step 2: Verify M9710A Shipment Contents
Keysight M9710A Startup Guide 11
Step 2: Verify M9710A Shipment Contents
The following items are also included with your M9710A AXIe High-Speed Digitizer
order:
Part Number Quantity Description
M9710A 1 AXIe High-Speed Digitizer.
M9700-10001 1 Keysight MD2 High-Speed Digitizer Software & Product Information DVD.
E2094-60003 1 Keysight IO Libraries Suite.
M9710-90001 1 Startup Guide in hard copy.
5962-0476 1 Certificate of Calibration.
5964-8178 1 Form-determining recalibration due date.
9320-6741 1 ROHS (China addendum).
U1092-80002 2 Cable, BNC (male) to MCX (male), 1 m.

Step 3: Install the Software
Step 3: Install the Software
System Requirements
Requirements Windows Linux
Operating
system
Windows 10 (32 or 64-bit), all versions
Windows 8.1 (32 or 64-bit), all versions
Windows 7 SP1 (32 or 64-bit)
Linux Kernel 2.6 or higher (32 or 64-bit),
Debian-8, Ubuntu-16.04, CentOS-7
Processor
speed
1 GHz 32-bit (x86), 1 GHz 64-bit (x64),
no support for Itanium64
As per the minimum requirements of the
chosen distribution
Available
memory
1 GB minimum1As per the minimum requirements of the
chosen distribution
Available disk
space
2.5 GB available hard disk space, includes2:
1.5 GB for Keysight IO Libraries Suite
1 GB for Keysight MD2
100 MB
Display Minimum of 1024 x 768, 96 or 120 DPI No display required
Browser Use a supported version of Internet Explorer; see
http://support.microsoft.com/kb/969393
Distribution supplied browser
1On older PCs with minimum RAM, installation can take a long time when installing the IO Libraries
Suite and the .NET Framework.
2Because of the installation procedure, less disk space may be required for operation than is required for
installation. The amount of space listed above is required for installation. The .NET Framework Runtime
Components are installed by default with most Windows installations, so you may not need this amount
of available disk space.
12 Keysight M9710A Startup Guide

Step 3: Install the Software
Keysight M9710A Startup Guide 13
Hardware Requirements
Item Requirements
Chassis AXIe chassis (Keysight M9502A 2-slot, or M9505A 5-slot chassis recommended).
Host Controller:
- Embedded Controller
- Remote Controller
Remote PC Host Controller, or AXIe Embedded Controller:
- Keysight M9536A or M9537A1AXIe Embedded Controller.
- A PC running one of the above operating systems.
(Recommended models are: HP Z420, HP Z440, or Dell T5810)
- For Laptop PC's: A Keysight M9045B ExpressCard Adaptor x1, with cable.
- For Workstations: A Keysight M9048A Desktop Adaptor x8, with cable.
1When using M9537A, the chassis (M9502A 2-slot or M9505A 5-slot) firmware has to be updated to the
latest version (available at http://www.keysight.com/main/software.jspx?id=2073359, or from
www.keysight.com/find/M9502A or www.keysight.com/find/M9505A, click on Product Support Center > Drivers,
Firmware & Software taband select AXIe Chassis Firmware).
Install the Software
If the Keysight MD2 software is installed on your computer, first uninstall the
Keysight MD2 software from the Control Panel > Programs and Features before
installing the Keysight MD2 High-Speed Digitizer Software.
Keysight IO Libraries Suite (IOLS)
The Keysight IO Libraries Suite (IOLS) contains the Keysight Connection Expert. This
software is included with your shipment (CD part number E2094-60003), and is also
available at www.keysight.com/find/IOsuite. This software must be installed first.
For Keysight IO Libraries Suite, the recommended version is indicated on MD2
Driver DVD or on www.keysight.com/find/MD2.
1. From the Keysight IOLS CD (E2094-60003) browser launch the installer.
2. Follow the installer prompts to install the IO libraries.
Instrument Software
The Instrument software, which includes device drivers (IVI-C, IVI-COM) and
documentation is delivered with your shipment (part number M9700-10001) or can be
downloaded from www.keysight.com/find/MD2.

Step 3: Install the Software
Version 2.2 or higher of the Keysight MD2 High-Speed Digitizer Software is
required.
1. From the Keysight MD2 High-Speed Digitizer Software & Product Information
DVD launch the installer.
2. Follow the installer prompts. Choose a "Complete" installation to install all soft-
ware and documentation, or a "Custom" installation to select from a listing of
components and other features.
3. After installation is complete, please shut-down the PC.
14 Keysight M9710A Startup Guide

Step 4: Install the Module
Keysight M9710A Startup Guide 15
Step 4: Install the Module
M9710A supported AXIe chassis configurations:
In a M9502A 2-slot chassis, two M9710A could be used.
In a M9505A 5-slot chassis, five M9710As could be used.
In a M9514A 14-slot chassis, up to thirteen M9710As could be installed.
The empty slots must be closed using Y1221A AXIe Filler Module.
In any case, the remaining slots should be filled either with another instrument,
or with an AXIe slot filler
The M9710A hardware does not support "hot-swap" operations. Before installing
the module into the chassis, power-off the chassis to prevent damage to the
module.
1. Make sure that the power cord is plugged-in to establish earth ground but the
chassis power is Off (Standby).
2. Position the chassis so that there is ample space between the chassis fan intake
and exhaust vents.
3. If you are using an embedded controller, this must normally be installed in slot 1 of
the chassis. In this case install the M9710A in slot 2 or higher.
If you are using M9537A AXIe Embedded Controller, the chassis (M9502A or
M9505A) firmware has to be updated to the latest version (available at
http://www.keysight.com/main/software.jspx?id=2073359, or from
www.keysight.com/find/M9502A or www.keysight.com/find/M9505A, click on Product
Support Center > Drivers, Firmware & Software > AXIe Chassis Firmware).
4. To insert the module into a chassis:
a. Align the module's board edges with the chassis guide rails and push it for-
ward into the chassis. Note: that it is the circuit board, not the metal cover
plate which must be inserted into the rails. The module should slide in eas-
ily, if it does not, withdraw it and re-check the alignment.
b. Locate the extraction handles at either end of the module. Extend the ends
of both handles by pulling them inwards towards each other; the plastic
ends will slide out by about 1 cm. Then put the handles into the extracted
position by pivoting them outwards until they are perpendicular to the front
panel as shown in the diagram below.

Step 4: Install the Module
c. Slide the module completely into the chassis. When the module's con-
nectors contact the chassis backplane you will feel some resistance, and
the extraction handles will begin to move inwards. Now you may press the
handles inwards and towards the front panel until the module is completely
inserted.
d. Slide the plastic ends of the extraction handles outwards and tighten the
captive retaining screws at both ends of the module.
5. Install filler panels in any unused slots. Missing filler panels may disrupt necessary
air circulation in the chassis.
6. If you are using a remote controller, with an interface such as the M9045B or
M9048A, connect the cable from the chassis to the PChost, as per the instruc-
tions that came with the interface.
7. Power up the chassis. It is often necessary to wait until the chassis and its mod-
ules have completed their start-up sequence before proceeding to power-up the
host controller.
8. Reboot or power-up the PC host. Check the module front panel indicators - after
the boot process the STATUS LED should be green, and no other LEDs lit.
16 Keysight M9710A Startup Guide

Step 4: Install the Module
Keysight M9710A Startup Guide 17
M9710A Front Panel Features
Please note that analog Input IN 1 to IN 4 have a maximum voltage limitation of
±1.5 Vmax while using the default 1V full scale range (±0.5 Vmax if using 0.25V
FSR).
Front panel of M9710A.
Front Panel Connectors
Connector Type Description
IN (1 - 4)
SMA female The analog signal inputs, which are DC-coupled and 50 Ω terminated.
The input full scale ranges are selectable:
Range Maximum Input
0.25 V ±0.5 Vmax
1 V ±1.5 Vmax
REF IN MCX female External reference clock input, AC coupled and 50 Ω terminated. It can accept a
100MHz signal from -3 to +3 dBm.
CLKIN
SMA female External clock input. AC coupled and 50 Ω terminated, signal level: +5 to +15
dBm. (Please refer to product user manual or datasheet for supported
frequency values).
TRG 1, 2, 3 MCX female These external trigger inputs are DC-coupled, 50 Ω terminated. The trigger
level range is ±5V.
TRGOUT MCX female Trigger Out signal. User selectable from several functions.
DPU JTAG USBMini Not currently supported.
CTR JTAG USB Mini Not currently supported.
I/O 1, 2 MCX female User configurable Input / Output signal. 3.3 V CMOS and TTLcompatible.
Digitizer can usually work with signals present at the external reference and
clock inputs (REF IN and CLK IN). However, to ensure the best performance, or if
the calibration is found to be unreliable, it is recommended to remove such
signals when working with internal clock.

Step 4: Install the Module
Front Panel LEDs
Indicator Purpose Color State Meaning
H/S Hot Swap Off Normal operating mode
Blue, blinking Initializing
OOS Out Of Service Off ATCA bus is ready
Red ATCA bus is not ready
LB, LC DPU status Off DPU FPGA is not configured
White Idle
STATUS Instrument
status
White, blinking Firmware initialization in progress
Green, blinking Software initialization in progress
Orange, blinking Warning (see note below)
Red, blinking Error (see note below)
Green OK
If warning or error status is observed, please try the following steps:
Power-cycle the chassis (If using a PCIe expansion chassis, observe the power
sequence requirements)
If the error persists please contact Keysight technical support
http://www.keysight.com/find/assist.
18 Keysight M9710A Startup Guide

Step 5: Verify Operation of the M9710A Module
Keysight M9710A Startup Guide 19
Step 5: Verify Operation of the M9710A Module
Keysight Connection Expert
The intention of this step is to verify correct operation of the newly installed module.
Run Keysight Connection Expert by clicking the task bar icon , and select
Connection Expert.
The list of installed modules is displayed. The instrument properties may be viewed by
clicking on the desired instrument from the list on the left.
Review the configuration data and then click on Start soft front panel to launch the
MD2 Soft Front Panel. This will provide control of the module for calibration, test and
other operational verification procedures.
If the module does not appear in the Keysight Connection Expert, first try the
Rescan button. If that does not work, restart your PC or embedded controller and
restart Keysight Connection Expert again.

Step 5: Verify Operation of the M9710A Module
Driver Graphical Interface: MD2 Soft Front Panel
The Keysight MD2 SFP (Soft Front Pannel) is a graphical interface for High-Speed
Digitizer Instrument Drivers that enables the control of any supported digitizers.
The MD2 SFP can be launched from Keysight
Connection Expert, directly from the Windows
Start Menu > Keysight MD2
Digitizer>Keysight MD2 SFP.
The Connection window opens with the selection of the digitizer to monitor. After
selecting your digitizer, click Connect. For details, please refer to MD2 SFPHelp.
Example of display after running a high-speed digitizer acquisition with the MD2 SFP (Acquisition parameters depends
on your digitizer).
20 Keysight M9710A Startup Guide
Table of contents
Other Keysight Media Converter manuals

Keysight
Keysight APM0100E User manual

Keysight
Keysight LPDDR5 User manual

Keysight
Keysight M9361A User guide

Keysight
Keysight N9029ACST User manual

Keysight
Keysight 11667C Service manual

Keysight
Keysight N7004A User manual

Keysight
Keysight E1418A Series User manual

Keysight
Keysight 34951A User manual

Keysight
Keysight M9185A User guide

Keysight
Keysight E1418A Series User manual