Kimberly-Clark KIMTECHT N95 User manual

Revised July 17, 2020
Kimberly-Clark warrants that its products (1) comply with K-C’s standard specifications as of the delivery date to K-C’s authorized distributors/direct purchasers (2) comply with all
K-C labeling representations; and (3) are manufactured in compliance with all applicable federal, state, and local laws in effect at the time and place of manufacture of the products.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. K-C is not liable for any kind of special, incidental, or consequential damages. K-C’s liability for breach of contract, tort or other cause of action shall not
exceed the product purchase price. Purchasers and users are deemed to have accepted the above warranty and limitation of liability, and cannot change the terms by verbal
agreement or by any writing not signed by K-C. To the extent required by applicable law, K-C does not limit its liability for death/injury resulting from K-C’s negligence.
®/TM Trademarks of Kimberly-Clark Worldwide, Inc. Marques déposées de Kimberly-Clark Worldwide, Inc. ©KCWW.
Page 1 of 1
KIMTECHTM N95 RESPIRATOR
KIMTECH™ N95 Respirator is a single-use respirator to be used by skilled professionals in critical environments who need to protect the process and
are mandated to wear specific PPE to protect against the transfer of non-oil aerosolized particulate matter.
Not tested against COVID-19 and therefore not recommended for efficacy or use. Not for medical use.
Product Description
Code
Description
Color
Quantity
53358
Respirator with pouch
White
50/bag, 6 bags/case, 300 total
Construction
Physical Properties
Property
Target
Test Method
NaCl Penetration
<5% @ 85 lpm
TEB-APR-STP-0059
Exhalation Resistance
<25mm H₂O
TEB-APR-STP-0003
Inhalation Resistance
<35mm H₂O
TEB-APR-STP-0007
Features
•NIOSH certified: TC# 84A-9042
•Comfortable non-irritating lining
•Flat pouch-style breathing chamber for added comfort
•Headbands of bicomponent elastomer material
•Fits secure to face, helps ensure tight facial seal, and prevents leakage
around edges
•Two layers of electro-statically treated meltblown filter media
•Provides a minimum of 95% filtration efficiency for 0.3 micron particles
•Not oil resistant
For Additional information: Contact your Kimberly-Clark representative or our North America Customer Service Team at (888)-346-GOKC (4652) or
KCPInfo@kcc.com.
Certificate of Conformance available online at www.kimtech.com/certificates.
K-C Confidential: The information contained in this document is intended for the use of the addressee(s) only and may contain privileged, confidential,
or proprietary information that should not be distributed publicly without Kimberly-Clark’s written consent.
Component
Material
Inner facing
Non-irritating polypropylene
Outer facing
Clean durable bicomponent material
Filter Media
Electro-statically treated meltblown
Headband
Elastomeric polypropylene material
Nosepiece
Flexible wire


2
N95
U
S
A
D
E
P
A
R
T
M
E
N
T
O
F
H
E
A
L
T
H
&
H
U
M
A
N
S
E
R
V
I
C
E
S
2
<%

3
Directions for Application
1. Separate the edges of the respirator to fully open it.
2. Slightly bend the nose wire to form a gentle curve.
3. Hold the respirator upside down to expose the two headbands.
4. Using your index ngers and thumbs, separate the two headbands.
5. While holding the headbands with your index ngers and thumbs, cup the respirator under your
chin.
6. Pull the headbands up and over your head.
7. Release the lower headband from your thumbs and position it at the base of your neck.
8. Position the remaining headband on the crown of your head.
9. Conform the nose piece across the bridge of your nose by rmly pressing down with your ngers.
10. Continue to adjust the respirator and secure the edges until you feel you have achieved a good
facial t. Now, perform a Fit Check.
Fitting Instructions:
• Follow Directions for Application each time respirator is worn.
• Check facial seal to assure proper t before entering any contaminated area.
• Adjust nosepiece if there is air leakage around the nose.
• Reposition headbands to secure facial seal around edges of respirator.
• Do not enter a contaminated area if a proper t cannot be obtained. Follow all instructions and
warnings on the use of this respirator, obtain a proper t, and wear during all times of exposure.
Failure to do so will reduce respirator eectiveness and user protection, and may result in
sickness or death.
KIMTECH™ N95 Pouch Respirator (TC-84A-9042) are NIOSH approved as N95 particulate lter respirators.They
provide 95% ltration eciency of 0.3 micron particles.
Intended Use:
The KIMTECHTM N95 Pouch respirator is intended for use against particulate aerosols free of oil; time use
restrictions may apply.
Use Instructions:
1. Before use, the wearer must be trained by the employer in proper respirator use in accordance
with applicable safety and health standards.
2. If the respirator becomes damaged or breathing becomes dicult, leave the area. Discard and
replace the respirator.
Warning: For the United States and countries using NIOSH-certied respirators. Before
occupational use, OSHA requires the user to be t tested with this model of respirator per
regulation 29 CFR 1910.134. Eective against oil-free particulate aerosols and dust. Important: Follow
all instructions and warnings on the use of this respirator. Wear during all times of exposure.
Failure to do so will reduce respirator eectiveness and user protection, and may result in
sickness or death. Time use limitations: If respirator becomes damaged, soiled, or breathing becomes
dicult, leave the contaminated area and properly dispose of respirator.
WARNING! 1. Do not use for sandblasting or to protect against asbestos, lead-based paint, pesticides,
oil aerosols, vapors or gases. 2. Do not wear this respirator when conditions prevent a good facial seal.
Reminder: It is important to t check the respirator each time it is worn. 3. This respirator is not for medical
use. 4. Never alter or modify this product.
These respirators are approved only in the following congurations:
TC- Protection1Respirator Cautions and Limitations2
84A-9042 N95
53358
ABCJMNOP
X
1. PROTECTION:
N95-Particulate Filter (95% lter eciency level) eective against particulate aerosols free
of oil; time use restrictions may apply.
2. CAUTIONS AND LIMITATIONS:
A. Not for use in atmospheres containing less than 19.5 percent oxygen.
B. Not for use in atmospheres immediately dangerous to life or health.
C. Do not exceed maximum use concentrations established by regulatory standards.
J. Failure to properly use and maintain this product could result in injury or death.
M. All approved respirators shall be selected, tted, used, and maintained in accordance with MSHA, OSHA,
and other applicable regulations.
N. Never substitute, modify, add, or omit parts. Use only exact replacement
parts in the conguration as specied by the manufacturer.
O. Refer to users instructions, and/or maintenance of these respirators.
P. NIOSH does not evaluate respirators for use as surgical masks.

This manual suits for next models
1
Table of contents
Other Kimberly-Clark Respiratory Product manuals

Kimberly-Clark
Kimberly-Clark RA3316V N95 User manual

Kimberly-Clark
Kimberly-Clark Kimtech N95 User manual

Kimberly-Clark
Kimberly-Clark RA3830V User manual

Kimberly-Clark
Kimberly-Clark KleenGuard RA3315 User manual

Kimberly-Clark
Kimberly-Clark RA3316 User manual

Kimberly-Clark
Kimberly-Clark Jackson R60 AIRMAX ELITE User manual