ADJUSTING THE ‘LUX’ CONTROL
1. Turning Lux control fully clock wise, the sensor will operate in both aylight an arkness.
2. Turning Lux control fully anti-clockwise, the sensor will operate in arkness only.
3. Set control to operate at your require aylight level.
ADJUSTING THE ‘TIME ON’ CONTROL
1. Turning the time control fully anti-clock wise will set the on uration to 10 secon s +/- 3
secon s.
2. Turning the time control fully clock wise will set the on uration to 15 minutes +/- 2minutes.
TROUBLE SHOOTING
Light ot comi g o
• Check that lamp is goo .
• Check there is nothing obscuring the PIR sensor.
I termitte t operatio
• Check there are no curtains that can move in the win .
• Check there are no heating vents nearby.
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
N L L
3. Fol the metal springs of the sensor upwar s an insert into the installation hole releasing
springs, the springs will hol sensor in position.
4. To access the lux an time controls, insert a small flat-bla e screw river into the open
release slot an twist, pull own until the controls are showing.
1. Turn ‘Time’control fully anti-clockwise an ‘Lux’ control fully clock wise refer to Dia:4.
TESTING
Dia:4
2. Re-connect mains supply, allow 30 secon s for the sensor to warm-up, an then perform a
walk-by in front of the sensor; lamp shoul turn on an stay on for approximately 10 secon s,
an will go off if no further movement is etecte .
TECHNICAL INFORMATION
Rate Voltage: 230V~50Hz
IP Rating: IP20
Ambient Light: <3-2,000 LUX (A j)
Time Delay: Min 10 sec ± 3sec
Max 15 min ± 2min
Rate Loa : Max 800W
Max 400W
Detection Range: 360°
Detection Distance: 6M max (<24°C)
Working Temp: -20° - + 40°C
Working Humi ity: <93%RH
Power Consumption: 0.5W approx
Installation Height: 2.2 - 4M
Detection Moving Spee : 0.6 - 1.5m/s