
Step1:SelectBatterytype
ForSC1210LD,SC1220LD:useprovidedjumpertoselectbatterytype.
•Connectbetweenpin6and7tochargeSealedLeadAcidbatteries
•Disconnectthejumperconnectedbetweenpin6and7tochargeFloodedbatteries
ForSCD1230:UseAppendixandfollowinginstructionstoselectbatterytype.
Step2:Connectingabattery
•Connect‘‐‘terminalpin4onunittobatterynegativeterminal
•Connect‘+’terminalpin3onunittobatterypositiveterminal
Step3:Connectingasolarpanel
•Connect‘‐‘terminalofsolarInput(pin2)onunittosolarpanelnegativeterminal
•Connect‘+’terminalofsolarInput(pin1)onunittosolarpanelpositiveterminal
Step4:ConnectingaDCload
•Connect‘‐‘terminalofLoadOutput(pin6)onunittosolarpanelnegativeterminal
•Connect‘+’terminalofLoadOutput(pin5)onunittosolarpanelpositiveterminal
5. UnderstandingtheUnitSetting
SC1210LDandSC1220LD:
Theunitisfullyautomatic;nootherunitsettingisrequiredoncethebatterytype(Sealed
LeadAcidorFlooded)issetanditisinstalledproperly.Itisrecommendedtoverifythe
stateofchargeofthebatteryregularlyandtoverifythattheloadconnectedtotheunitis
notoverratedfortheunit.Itisalsorecommendedtoverifythatthepowerconsumption
ontheloadislessthatthesolarpanelcanproduce.
SCD1230:
Theunithasabuilt‐inclockandtheDCLoadisprogrammabletobeturnedONandOFF
automaticallyeachdaythroughtheunitsetting(seeAppendixformoredetails).TheDC
LoadcanalsobeswitchedtoONorOFFmanuallyusingthe‘Enter’button.TheDigital
displayshowschargingstatus,solarpanelvoltage,batterychargingcurrent,DCLoad
currentanderror/warningcode.
6. UnderstandingtheDisplayonSCD1230
SymbolDescriptions
Solarisconnectedandischargingthebattery
DCLoadisONandcurrentisdrawingfromthebattery
Therelatediconindicatesthebatterytypeisset
Therelatediconshowsthechargingstatus.
AutomaticLoadON/OFFfunctionissetandLoadisON
AutomaticLoadON/OFFfunctionissetandLoadisOFF
24Vbatterysystemisdetected
Thebatteryisdischarging.Chargingcurrentis<Loadcurrent
Thedisplayshowstime(e.g.’12:00’),Chargingcurrent,Loadcurrent
(e.g.’20.0’),batteryvoltage(e.g.’12.8’),Timersetting(e.g.‘C01’andError
code(e.g.’E02’)
Thedisplayisshowingtheafternoontime
ThedisplayisshowingcurrentinAmps
ThedisplayisshowingvoltageinVolts
Errorisdetectedandthedisplayisshowingtheerrorcode
7. OperationandMaintenance
Theunitisfullyautomaticandnounitsettingisrequiredonceitisinstalledproperly.Itis
recommendedtoverifythestateofchargeofthebatteryregularlyandtoverifythatthe
loadconnectedtotheunitisnotoverratedfortheunit.Itisalsorecommendedtoverify
thatthepowerconsumptionontheloadislessthatthesolarpanelcanproduce.
Thefollowingperiodicinspectionsandmaintenancetasksarehighlyrecommendedforbest
performance.
•Checkforanyrustingorcorrosionaroundthebatteryterminals
•Verifythesolarpanelsandloadsconnecteddonotexceedtheunitrating
•Tightenalltheterminalscrewsandinspectforanyloose,brokenorburntwire
connections.
•Ensuresolarpanelismountedproperlyandisplacedintherightposition.Checkforany
dirt,debrisandcorrosiononthepanel.
•Periodicallycleansolarpanelswithwateranddonotusechemicals
8. Troubleshooting
NoOutputatDCLoad:
zCheckDCloadterminalconnection.Connectionmaybelooseordisconnected.For
SCD1230,checkthe‘ClockOFF’icon.TheDCloadmaybeturnedOFFautomaticallybythe
unitsetting.
zCheckconnectionpolarity.Reversepolarityonanyterminalswilldamageunitandisnot
coveredbywarranty.
zCheckthebatteryvoltage:
−ForSC1210LDandSC1220LDmodels,checkthatthe‘Loaddisconnect’LEDisON.Verify
batteryvoltageisabove12.6V.
−ForSCD1230,checkforanyerrorcodeonthedisplay.Verifybatteryvoltage.Checkifthe
timeandtheautomaticON/OFFfunctionisactive.
Batterydidnotcharge:
zVerifythesolarpanelisfunctioningproperly.Checkforpoorconnectiononthesolarpanel
zVerifysolarpanelisnotblockedbyanysurroundingtallobjects.Checkthesolarpanel
surroundingarea.
zChecksolarpanelandbatteryconnections.Looseconnectionwillreduceunit
performance.
zCheckconnectionpolarity.Reversepolarityonanyterminalswilldamageunitandisnot
coveredbywarranty.
zVerifytheDCloadconsumption.ThepowerconsumedbytheDCloadshouldbelessthan
thesolarpanelgenerates.
9. Specifications
SC1210LDSC1220LDSCD1230
BatteryVoltageSystem12VDC12/24VDC
SolarOpenCircuitVoltage(max.)26VDC12V:26VDC*
ChargeCurrent(Max.)10A20A30A
LoadCurrent(max.)10A20A30A
LoadSurgeCurrent(max.)35A‐1min40A‐1min50A?
OperationCurrent<10mA<10mA<20mA?
ChargeControllerTypePWM(PulseWidthModulation)
ChargeControllerGroundingSystemNegativeGrounding
RegulatedVoltage
SealedBattery Bulk:14.2V
Float:13.5V
NotApplicable
FloodedBatteryBulk:14.4V
Float:13.3V
Bulk:14.4V*
Float:13.3V*
GEL
11.Warranty
TwoYearsLimitedWarranty
Thelimitedwarrantyprogramistheonlyonethatappliestothisunit,anditsetsforthallthe
responsibilitiesofKISAE.Thereisnootherwarranty,otherthanthosedescribedherein.Any
impliedwarrantyofmerchantabilityoffitnessforaparticularpurposeonthisunitislimitedin
durationtothedurationofthiswarranty.Thisunitiswarranted,totheoriginalpurchaseronly,
tobefreeofdefectsinmaterialsandworkmanshipforoneyearfromthedateofpurchase
withoutadditionalcharge.Thewarrantydoesnotextendtosubsequentpurchasersorusers.
Manufacturerwillnotberesponsibleforanyamountofdamageinexcessoftheretail
purchasepriceoftheunitunderanycircumstances.Incidentalandconsequentialdamages
arespecificallyexcludedfromcoverageunderthiswarranty.Thisunitisnotintendedfor
commercialuse.Thiswarrantydoesnotapplytodamagetounitsfrommisuseorincorrect
installation/connection.Misuseincludeswiringorconnectingtoimproperpolaritypower
sources.
Return/RepairPolicy:
Ifyouareexperiencinganyproblemswithyourunit,pleasecontactourcustomerservice
toretailstore.Afterspeakingtoacustomerservicerepresentative,ifproductsaredeemed
non‐workingormalfunctioning,theproductmaybereturnedtothepurchasingstorewithin
30daysoforiginalpurchase.Anydefectiveunitthatisreturnedtomanufacturerwithin30
daysofthedateofpurchasewillbereplacedfreeofcharge.Ifsuchaunitisreturnedmore
than30daysbutlessthanoneyearfromthepurchasedate,manufacturerwillrepairtheunit
or,atitsoption,replaceit,freeofcharge.Iftheunitisrepaired,neworreconditioned
replacementpartsmaybeused,atmanufacturer’soption.Aunitmaybereplacedwithanew
orreconditionedunitofthesameorcomparabledesign.Therepairedorreplacedunitwill
thenbewarrantedunderthesetermsfortheremainderofthewarrantyperiod.Thecustomer
isresponsiblefortheshippingchargesonallreturneditems.
LIMITATIONS:
Thiswarrantydoesnotcoveraccessories,suchasadaptersandbatteries,damageordefects
resultfromnormalwearandtear(includingchips,scratches,abrasions,discolorationor
fadingduetousageorexposuretosunlight),accidents,damageduringshippingtoourservice
facility,alterations,unauthorizeduseorrepair,neglect,misuse,abuse,failuretofollow
instructionsforcareandmaintenance,fireandflood.Ifyourproblemisnotcoveredbyhis
1‐877‐897‐5778forgeneralinformationifapplicable.
zSelectanappropriatemountinglocationandorientation.Theunitcanbeorientedinany
direction.
zHoldthesolarchargecontrolleragainstthemountingsurfaceandmarkthepositions
usingthemountingflangesasguide.
*voltageisdoublewhenunitisuseon24Vbatterysystem.
zPilot‐drillthefourmountingholes.
10.UnitMounting
Bulk:14.4V*
NotApplicable
Float:13.7V*
AGMBulk:14.6V*
Float:13.6V*
LithiumBulk:13.9‐14.6V*
Float:13.0‐14.0V*
ProgramBulk:13.9‐15.0V*
Float:13.0‐14.0V*
LoadDisconnectVoltage11.5V11.5V*
LoadDisconnectVoltageRangeNotapplicable10‐11.8V*
LoadReconnectVoltage12.6V12.6V*
LoadReconnectVoltageRangeNotapplicable10‐12.3V*
RecommendedWireSize#10‐12AWG#6AWG
OperatingTemperature‐40to60°C(‐40to140°F)
Dimensions(LxWxH)4.1x4.1x1.3inches
(104x104x33mm)
6.7x4.7x1.7inches
(170x120x43mm)
Weight0.7lb
(320g)
0.77lb
(350g)
1.25lb
(570g)