Klafs 18043 User manual

Operating Instructions
Klafs Softclima with Control System type 18043

Contents Page
1. Brief description of Softclima controller ...................... 3
2. Bathing types ................................................. 3
2.1. Sauna ............................................................... 3
2.2. Softclima ............................................................. 3
3. Technical data ................................................ 3
4. Intended Use ................................................. 4
5. General safety information ................................... 4
6. Operation and Display Elements ............................. 5
7. Operation .................................................... 6
7.1. Switching the cabin light On/Off ......................................... 6
7.2. Switching stand-by mode On/Off ........................................ 6
7.3. Starting bathing type Sauna ............................................. 6
7.4. Starting Softclima mode ................................................. 6
7.5. Changing bathing mode ................................................ 7
7.6. Stopping Sauna mode .................................................. 7
7.7. Stopping Softclima mode ............................................... 7
7.8. PLURIS - Starting the evaporator .......................................... 8
7.9. PLURIS - Shutting down the evaporator ..................................... 10
8. Individual settings ............................................ 12
8.1. Sauna/Softclima temperatures ........................................... 12
8.2. Setting sauna temperature ............................................... 12
8.3. Setting Softclima temperature ............................................ 13
8.4. Setting the Softclima humidity ............................................ 13
8.5. Setting the exhaust air flap for cabin ventilation (option) ....................... 13
9. If something does not work .................................. 14
9.1. Error indication at bathing type LEDs ...................................... 14
9.2. Other possible errors ................................................... 14
10. Maintenance and Cleaning ................................... 15
10.1. Cleaning the sauna cabin ............................................... 15
10.2. Softclima ............................................................. 16
11. Notes ......................................................... 17
12. Addresses .................................................... 20

Softclima
PAGE 3
50701256/12.12
1. Brief description of Softclima controller
The Klafs Softclima control system offers you the possibility to operate your sauna with high
convenience. The bathing conditions can be changed within the allowed adjustment range before
and during the operation.
I/O
Main switch Operation elements
2. Bathing types
2.1. Sauna
Sauna
With temperatures of 85 - 100 °C and a low relative humidity.
WARM AIR BATH
With extra mild climate, with temperatures of 45 - 60 °C and a relative humidity of up to approx.
20 %.
2.2. Softclima
Soft steam bath
As gentle and humid bath with temperatures of 50 - 60 °C and infinitely adjustable humidity.
With the Soft Steam Bath, the temperature and the relative humidity are controlled by a
microprocessor controller.
Herbal Bath
With same climate values as for soft steam bath, and additional evaporation of herbal extracts
and scent extracts mixed with water. This improves the effect of the soft steam bath.
Taking a sauna in your Klafs sauna cabin should benefit your health and well-being.
Therefore: Don't overdo it ! That applies to the temperature, the relative humidity and the bathing time.
Orientate yourself not only on the given bathing times, but also on your condition. Leave the cabin as
soon as you no longer feel well.
3. Technical data
Control System Type 18043: 3/N/PE ~400 V, max. 9 kW.
Operating conditions: Temperature 0 °C to 35 °C, max. 80 % relative humidity.

Softclima
PAGE 4 50701256/12.12
4. Intended Use
The Softclima controller is intended exclusively for normal use for controlling approved (registered
with VDE or TÜV by Klafs) sauna stoves and automatic evaporators (intended use).
Any other use is considered not in accordance with the terms of usage! The manufacturer is not
responsible for damage resulting from other forms of usage; the user alone carries this risk. Proper
and intended use and operation include compliance with the requirements for assembly, operation,
maintenance and repair stipulated by the manufacturer.
The Softclima control system may only be operated and maintained by persons who are familiar with
its usage and aware of the dangers involved. Follow the relevant German VDE regulations as well as
other generally recognized safety rules. Damage resulting from arbitrary changes to the control
system are excluded from the manufacturer's liability.
5. General safety information
Read and observe the operating and safety instructions before start-up!
dBefore opening the control system housing remove the power from the control system!
dThe control system may be connected to mains by a locally authorised electrician only!
dSauna installations may be connected to mains with a fixed connection only according to VDE
regulations. In the connecting feed line use a residual-current breaker InNv0.03 A with at
least 3 mm contact opening.
dInform Klafs Customer Service of problems that a certified electrician cannot repair!
dOnly use original Klafs spare parts!
dArbitrary changes to the control system are not allowed!
dInstall the control system, in accordance with the assembly instructions!
dElectrical wiring inside the cabin and the cabin walls must have silicone insulation.
dBefore activating the control system always make sure that no inflammable objects are on or
near the sauna heater. FIRE RISK!
dDo not use the sauna to dry your laundry!
dNever pour concentrated aromatic oils or extracts directly onto the sauna heater. Only use the
indicated concentration (approx. 20 - 30 drops to 1 liter of water)!
dNever pour herbal extracts, as used in Softclima mode, directly into the evaporator. Outside of
the cabin, fill the fragrance bowl a quarter full with water and add the herbal extracts drop by
drop in accordance with the instructions on the bottle. Then re-attach the fragrance bowl to the
steam exit!
dAs infusion agent it is only permissible to use Klafs aromatic extract!
dNever store the bottle containing aromatic oils or infusion agent in the sauna cabin!
dRegularly check the sauna heater for damage.
dThis equipment is not intended for use by persons (including children) with reduced, physical,
sensory or mental abilities or by persons with a lack of experience or knowledge, unless they
have received instructions in the use of the equipment or are supervised by a person responsible
for their safety. Children must be supervised to ensure that they will not play with the unit.

Softclima
PAGE 5
50701256/12.12
6. Operation and Display Elements
I/O
Main switch Operation elements
Display elements
D
A
I/O
B
C
E
F
Unit/
button:
Description: Function:
I/O Main switch Switch On/Off stand-by of control system.
ACubicle light button Cabin light On/Off switch.
BMODE button Mode selection: Sauna, Softclima or End programme.
CBathing type LEDs Displays the selected bathing mode.
dA permanently lit END LED (C) indicates standby
mode.
dA flashing Sauna/Softclima LED indicates the selected
bathing mode.
Error Indicator.
'See page 14.
DRotary knob Sauna
temperature To set temperature - Sauna.
ERotary knob Softclima
temperature To set temperature - Softclima bath.
FRotary knob Softclima
humidity To set Softclima bath humidity.

Softclima
PAGE 6 50701256/12.12
7. Operation
7.1. Switching the cabin light On/Off
.Prerequisite: Switch On the main switch of the control system.
1. Keep the .
7.2. Switching stand-by
mode On/Off
1. Press button I/O.
.When the master switch is on the controller is
in standby mode and Softclima or Sauna
mode can be started from the control panel. I/O
Main switch
Prerequisite for the following operations:
.The control system is switched to stand-by.
7.3. Starting bathing type Sauna
Fire risk!
Before starting up the controller, always check that there are no combustible objects on
or near the sauna stove.
Remove herbal aroma pillow before starting Sauna mode.
1. Press the MODE button, repeatedly if necessary, until the Sauna mode LED lights up.
'Setting temperature - see page 12.
.The sauna heater switches On. The sauna is heated and is ready for bathing after the warm-up
period.
After 4 and/or 6 hours, the sauna heater switches off automatically.
Delivery settings: 4 hours.
7.4. Starting Softclima mode
Fire risk!
Before starting up the controller, always check that there are no combustible objects on
or near the sauna stove.
1. Fill the water container of the Softclima heater before starting the Softclima mode.
'Fill the evaporator with water - see page 8.
2. Press the MODE button, repeatedly if necessary, until the Softclima mode LED lights up.
'Setting temperature - see page 12.
'Setting humidity - see page 13.
.The sauna heater switches On. The sauna is heated and is ready for bathing after the warm-up
period.

Softclima
PAGE 7
50701256/12.12
7. Operation
7.5. Changing bathing mode
The bathing mode can be changed while a programme is in progress.
1. Press the MODE button, repeatedly if necessary, until the Sauna or Softclima mode LED lights up.
.A transition period of at least 20 minutes is necessary because of the different climatic conditions
of the two forms of bathing.
7.6. Stopping Sauna mode
1. Press the MODE button, repeatedly if necessary, until the End LED lights up.
.The sauna heater switches Off.
2. To switch off the controller: Press I/O button on the controller.
.The End LED goes out.
3. After the bath, temporarily open the cabin door and leave it open to air out the cabin.
7.7. Stopping Softclima mode
1. Press the MODE button, repeatedly if necessary, until the End LED lights up.
.The sauna heater is switched Off and the 25-minute-follow-up program starts. While the follow-on
programme is running, the End LED flashes. As soon as the follow-on programme has ended, the
End LED remains permanently lit.
2. Then switch off the controller: To do so press I/O button on the controller.
.The End LED goes out.
Danger of scalding!
Drain the water only after the heater has cooled off.
3. Drain the cooled-off water from the water tank of the Softclima heater.
'Draining off residual water - see page 10.
4. After the bath, temporarily open the cabin door and leave it open to air out the cabin.

Softclima
PAGE 8 50701256/12.12
7. Operation
7.8. PLURIS - Starting the evaporator
Fire risk!
Before starting up, always check
there are no combustible objects on
or near the sauna stove.
12
3
Hot surfaces - Risk of skin
burns!
Immediately after the bath the
cover (1) is still hot.
Protect hands and fingers from burns.
Fill the evaporator with water
1. Use the aroma fork (2) to remove the
cover (1).
2. Fill the water container (3) with water via the
port.
.Maximum filling capacity is 7 liters of water.
3. Put the cover (1) back on.
Add scent to the fragrance bowl 42
1
Hot surfaces - Risk of skin
burns!
Immediately after the bath the
cover (1) is still hot.
Protect hands and fingers from burns.
Fire risk!
Do not fill the fragrance bowl at the
heater.
1. Use the aroma fork (2) to remove the
cover (1).
2. Pour diluted scent into the fragrance bowl (4).
3. Put the cover (1) back on.
Continued on the next page

Softclima
PAGE 9
50701256/12.12
7. Operation
7.8. PLURIS - Starting the evaporator
Continued
Place herbal pillow (option) 2
3
1
4
Fire risk!
Do not place herb pillow (4) on hot
stones.
Use herb pillows approved by Klafs
only.
1. Remove the herb pillow support (1) from the
steam exit body (3) with the aroma fork (2).
2. Place the herb pillow (4) in the herb pillow
support (1).
3. Place the herb pillow support (1) back on the
steam exit body (3).

Softclima
PAGE 10 50701256/12.12
7. Operation
7.9. PLURIS - Shutting down the evaporator
Drain residual water
1
3
2
Drain off residual water after every
use.
Hot surfaces - Risk of skin
burns!
The residual water is still hot
immediately after the bath.
Protect hands and fingers against
scalding.
1. Place the filler can (1) under the discharge
opening (2).
2. Open the drain valve (3).
3. As soon as the evaporator is empty, close the
drain valve (3).
4. Empty the filler can (1).
Empty the fragrance bowl 45
Hot surfaces - Risk of skin
burns!
Immediately after the bath the
fragrance bowl (4) is still hot.
Protect hands and fingers against
scalding.
1. Use the aroma fork to remove the fragrance
bowl (4) from the cover (5).
2. Rinse the fragrance bowl with water.
3. Place the fragrance bowl (4) back on the
cover (5).
Continued on the next page

Softclima
PAGE 11
50701256/12.12
7. Operation
7.9. PLURIS - Shutting down the evaporator
Continued
Remove the herbal pillow (option) 2
3
1
4
Danger of scalding!
The herb pillow support is still hot
immediately after the bath.
1. Remove the herb pillow support (1) from the
steam exit body (3) with the aroma fork (2).
2. Dispose of herb pillow (4).
3. Place the herb pillow support (1) back on the
steam exit body (3).

Softclima
PAGE 12 50701256/12.12
8. Individual settings
I/O A D C BEF Unit/
button:
Description:
ACubicle light button
BMODE button
CBathing type LEDs
DRotary knob Sauna temperature
ERotary knob Softclima temperature
FRotary knob Humidity
8.1. Sauna/Softclima temperatures
Sauna temperature
.Normal temperature 85 °C - 95 °C.
.The centre position of the sauna temperature control Dcorresponds to
approx. 80 °C.
Softclima temperature
.Normal temperature 50 °C - 60 °C.
.The centre position of the Softclima temperature control Ecorresponds to
approx. 55 °C.
The temperature sensor is mounted in the warm air stream above the sauna heater.
An unavoidable temperature difference exists between the temperature sensor and the
temperature display. Therefore, the temperature control knob has no marked scale.
8.2. Setting sauna temperature
Setting sauna temperature
1. Turn the sauna temperature control Dclockwise as far as the stop.
2. Observe the temperature display in the cabin.
3. Has the desired temperature been reached? Slowly turn the sauna temperature control D
anticlockwise.
.A soft click in the control system can be heard. Leave the sauna temperature control Din that
position.
Readjusting sauna temperature
1. Readjust the sauna temperature control Dto the desired temperature.
2. Mark the temperature that you find the most comfortable.

Softclima
PAGE 13
50701256/12.12
8. Individual settings
I/O A D C BEF Unit/
button:
Description:
ACubicle light button
BMODE button
CBathing type LEDs
DRotary knob Sauna temperature
ERotary knob Softclima temperature
FRotary knob Humidity
8.3. Setting Softclima temperature
Setting Softclima temperature
1. Turn the Softclima temperature rotary knob Eall the way to the right until the stop.
2. Observe the temperature display in the cabin.
3. Has the desired temperature been reached? Turn the Softclima temperature rotary knob Eslowly
to the left.
.A soft click in the control system can be heard. Leave the Softclima temperature rotary knob Ein
this position.
Readjusting Softclima temperature
1. Readjust the Softclima temperature control Eto the desired temperature.
2. Mark the temperature that you find the most comfortable.
8.4. Setting the Softclima humidity
Setting the Softclima humidity
1. Set the desired humidity for the Softclima mode with the humidity rotary knob F.
.Adjust according to personal preferences. The humidity can be adjusted with the humidity rotary
knob Fany time during operation.
8.5. Setting the exhaust air flap for cabin ventilation (option)
Heating up
Exhaust air flap, level 1.
With this position, there is only a low air flow.
Sauna mode
Exhaust air flap, level 4.
Bathing operation with maximum number of sauna
users. With this position, there is a maximum air
flow.
1
4
Level
It is better to obtain a larger air flow volume for the
sauna climate. Intermediate stages can be selected
in accordance with the number of sauna users.
4

Softclima
PAGE 14 50701256/12.12
9. If something does not work
9.1. Error indication at bathing type LEDs
Repair and maintenance is to be carried out exclusively by Klafs' service personnel or by
personnel expressly authorized by Klafs!
The following errors are indicated by simultaneous flashing of all LEDs.
No. Display Error
1Fast flashing. Error safety temperature limiter (STL).
2Slow flashing. Error temperature sensor.
3Short flashing (0.1 sec On
0.9 sec. Off). Error on one of the rotary control knobs of the control
system.
9.2. Other possible errors
Error Cause Remedy
The control sys
tem cannot be
switched On.
No operating voltage availa
ble. Check the FI-switch and the fuse in the mains
supply.
Fuse SI102 or SI104 trigge
red. Replace fuse SI102 (1.6 AT) or
SI104 (1.0 AT) or contact Klafs Service.
The cabin light
does not turn On.
The main switch of the
control system is not switched
On.
Switch On the main switch at the control
system.
Light bulb defective. Procedure:
Remove power from the control system.
Change the light bulb.
.Replace with a light bulb of the same
wattage.
No mains voltage. Check the FI-switch and the fuse in the mains
supply.
The Fuse SI103 light trigge
red. Replace fuse SI103 light (0.6 AT) or contact
Klafs Service.
Evaporator does
not heat.
Acoustic signal on heater. Fill water tank with water.
Water tank is empty.

Softclima
PAGE 15
50701256/12.12
10. Maintenance and Cleaning
10.1. Cleaning the sauna cabin
The high humidity level in Softclima mode does not harm the wood of your cubicle.
The requirement is that the cabin is well aired out after usage.
Never hose down inner cabin walls, bench or seats with water or a high pressure
cleaner!
Dirty benches
Wipe the wooden surfaces with a damp cloth.
If necessary, sand the surface of the benches with fine sandpaper.
The benches can also be washed off with a 3 %- hydrogen peroxide solution (available in
specialized stores).
Disinfectants are highly corrosive!
Therefore, pay attention to the relevant safety regulations!
Use household rubber gloves!
The outer cabin walls are impregnated or glazed.
In no case glaze, paint or impregnate the inner panelling or the cabin inner walls and
units (benches etc.).

Softclima
PAGE 16 50701256/12.12
10. Maintenance and Cleaning
10.2. Softclima
Note!
Only allow work to be done on electrical components/assemblies by qualified
electricians that work in accordance with the prevailing electrotechnical rules and
regulations.
Evaporator - draining
1. Place the filler can (1) under the discharge
opening (2). Open the drain valve (3).
2. As soon as the evaporator is empty, close the
drain valve (3).
3. Empty the filler can (1).
1
3
2
45
1
Evaporator - decalcifying
4. Remove cover (4) of evaporator.
5. Fill the evaporator unit (5) with water.
6. Add approx. two tablespoons of normal
household decalcifier (chlorine-free!) to the
evaporator unit (5).
7. Allow the decalcifying mixture to work over
night on the calcium layer, at least 12 hours.
The decalcifying process can be easily
repeated 2 - 3 times for the same length of
time to ensure that the entire calcium deposit
is dissolved.
8. Place cover (4) on evaporator.
9. Place the filler can (1) under the discharge
opening (2). Open the drain valve (3). Drain
water into the filler can (1).
Evaporator - rinse
10. Close the drain valve (3).
11. Remove cover (4) of evaporator.
12. Fill the evaporator unit (5) with water.
13. Place the filler can (1) under the discharge
opening (2). Open the drain valve (3).
14. After draining the evaporator, close the drain
valve (3).
15. Repeat the rinsing procedure two or three
times.
16. Place cover (4) on evaporator.

Softclima
PAGE 17
50701256/12.12
11. Notes

You can also find
many accessories in
our online shop at
www.klafs.de
You can also find
many accessories in
our online shop at
www.klafs.de
Softclima
PAGE 20 50701256/12.12
12. Addresses
Wherever you are: Klafs is near you!
We provide expert service.
Klafs GmbH & Co. KG
Parent company Germany:
Erich‐Klafs‐Straße 1-3
D-74523 Schwäbisch Hall
Customer Service Tel. +49 791 501-220
Accessories / Spare parts Tel. +49 791 501-310
Switzerland:
Klafs AG
Oberneuhofstr. 11
CH-6342 Baar/Zug
Tel. +41 41 760 22 42
Austria:
Klafs GmbH
Sonnwiesenweg 19
A-6361 Hopfgarten/Tirol
Tel. +43 5335 2330-0
We hope your ”Klafs Softclima with Control System Type 18043“
brings you lots of fun, relaxation, well-being and rejuvenation.
Subject to technical modifications.
Reproduction in whole or in part is prohibited without the written permission of
Klafs GmbH & Co. KG
Article number 50701256 / Release 12.12
Table of contents