manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Knightsbridge
  6. •
  7. Accessories
  8. •
  9. Knightsbridge HBLS Instruction Manual

Knightsbridge HBLS Instruction Manual

Other Knightsbridge Accessories manuals

Knightsbridge RCD9000 Instruction Manual

Knightsbridge

Knightsbridge RCD9000 Instruction Manual

Knightsbridge OS001 Series Instruction Manual

Knightsbridge

Knightsbridge OS001 Series Instruction Manual

Knightsbridge OSHFREC Instruction Manual

Knightsbridge

Knightsbridge OSHFREC Instruction Manual

Knightsbridge OS0010 Instruction Manual

Knightsbridge

Knightsbridge OS0010 Instruction Manual

Knightsbridge MSENSOR Instruction Manual

Knightsbridge

Knightsbridge MSENSOR Instruction Manual

Knightsbridge DC007 Instruction Manual

Knightsbridge

Knightsbridge DC007 Instruction Manual

Knightsbridge OS0016 Instruction Manual

Knightsbridge

Knightsbridge OS0016 Instruction Manual

Knightsbridge OS001 Instruction Manual

Knightsbridge

Knightsbridge OS001 Instruction Manual

Knightsbridge DC002 Instruction Manual

Knightsbridge

Knightsbridge DC002 Instruction Manual

Knightsbridge TPB14SLED Instruction Manual

Knightsbridge

Knightsbridge TPB14SLED Instruction Manual

Knightsbridge IP9000R Instruction Manual

Knightsbridge

Knightsbridge IP9000R Instruction Manual

Knightsbridge DC001 Instruction Manual

Knightsbridge

Knightsbridge DC001 Instruction Manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
122
INSTALLATION & MAINTENANCE MANUAL
HBLS (sensor for HBL fittings)
IP
65
230V
50Hz
2
These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following product:
HBLS (sensor)
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• Installation of this sensor should only be carried out by a qualified electrician or competent person
to the latest Building and current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this sensor is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this sensor when deciding the location for
installation
• This product is Class II double insulated
• This product is IP65 rated (indoor use only)
• The dimming protocol used on this sensor is 1-10V
• This sensor is designed to work with the HBL series products only
• Provide power to the required point of installation. Suitable IP rated junction boxes should be used
where required
• We recommend an installation height of up to 15m max
• Remove screws from sensor mounting bracket holes and line up bracket and screw into place
(See Fig 1)
• Attach sensor to bracket via 3 screws
• Wire the sensor as per Fig 2 ensuring correct polarity is observed
HBLS
Theseinstructionsshouldbereadcarefullyandretainedafterinstallationbytheenduserforfuturereferenceand
maintenance.
Theseinstructionsshouldbeusedtoaidinstallationofthefollowingproduct:
HBLS(sensor)
SAFETY
• Installationofthissensorshouldonlybecarriedoutbyaqualifiedelectricianorcompetentpersontothe
latestBuildingandcurrentIEEWiringRegulations(BS7671)
• Pleaseisolatemainspriortoinstallation/maintenance
• Checkthetotalloadonthecircuit(includingwhenthisluminaireisfitted)doesnotexceedtheratingofthe
circuitcable,fuseorcircuitbreaker
• PleasenotetheIP(IngressofProtection)ratingofthissensorwhendecidingthelocationforinstallation
• ThisproductisClassIIdoubleinsulated
• ThisproductisIP65rated
• Thedimmingprotocolusedonthissensoris1-10V
INSTALLATIONOFSENSOR
• Providepowertotherequiredpointofinstallation.SuitableIPratedjunctionboxesshouldbeusedwhere
required
• Werecommendaninstallationheightofupto15mmax
• Removescrewsfromsensormountingbracketholesandlineupbracketandscrewintoplace(SeeFig1)


• Attachsensortobracketvia3screws
• WirethesensorasperFig2ensuringcorrectpolarityisobserved






Sensormounting
bracket
Fig 1
3


Fig1
SENSORSETUP
Detectionarea
Canbereducedbyselectingthedipswitchlayoutbelow.

S1
Detection
Area
On
100%
-
50%

Holdtime
Referstothetimeperiodthelampremainsat100%illuminationafternomotionisdetected.

S2
S3
S4
Holdtime
On
On
On
5sec
-
On
On
30sec
On
-
On
90sec
-
-
On
3min
On
On
-
20min
-
-
-
30min

Neutral–blue
(Sensor)
Neutral-blue
Earth–green/yellow
White:Dim-
Blue:Dim+
Live-brown
Switchedlive–yellow
(Sensor)
Black:Dim-
Red:Dim+
Live–brown
(Sensor)
Fig 2
SENSOR SETUP
Detection area
Detection area can be adjusted from a maxi-
mum range of 15 meters down to 7 meters by
observing the below settings
S1 Detection
Area
On 100%
- 50%
ON
Hold time
Hold time refers to the time that the
luminaire will remain at 100% brightness
after no motion is detected
S2 S3 S4 HOLD TIME
On On On 5sec
- On On 30sec
On - On 90sec
- - On 3min
On On - 20min
- - - 30min
ON
Standby period
Refers to the time period that the luminaire will
remain at low light level in the absence of movement
If set to “DISABLE”, the low light level will
permanently be maintained until motion is detected
S5 S6 S7 STANDBY
PERIOD
On On On DISABLE
- On On 60min
On - On 30min
- - On 10min
On On - 5min
- - - 5sec
ON
Standby dimming level
This setting refers to the light level you
require once “hold time” has elapsed
ON
S8 S9 STANDBY
DIMMING LEVEL
On On 50%
- On 30%
On - 20%
- - 10%
ON
Daylight sensor
This setting is to set the ambient light level you
would require the luminaire to operate in, selecting
“DISABLE” would enable the luminaire to operate at
all times regardless of ambient light levels
S10 S11 S12 DAYLIGHT
SENSOR
On On On DISABLE
- On - 200lx
On - - 100lx
- - - 50lx
• Switch on and check for correct operation
4
ML Accessories Limited
LU5 5TA
www.mlaccessories.co.uk AKJUL18_V3
This product must be disconnected from the circuit if subjected to any high voltage or insulation
resistance testing. Irreparable damage will occur if this instruction is not followed.
This product is for indoor use only and not to be installed outside
The unit should be recycled in the correct manner when it reaches the end of its life. Check local
authorities for where facilities exist.
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may
damage the fitting.
• Switch on power supply and check for correct operation
WARNING
GENERAL
DETECTION DIAGRAM
Standbyperiod
Thisistheperiodthelampremainsatthelowlightlevelbeforeitcompletelyswitchesoff.WhensettoDisablemode,the
luminaireremainsonatthelowlightuntilmotionisdetected.

S5
S6
S7
Standby
period
On
On
On
Disable
-
On
On
60min
On
-
On
30min
-
-
On
10min
On
On
-
5min
-
-
-
5sec

Standbydimminglevel
Thisisthelowlightlevelaftertheholdtimehaslapsedintheabsenceofmotion/movement.

S8
S9
Standby
dimminglevel
On
On
50%
-
On
30%
On
-
20%
-
-
10%

Daylightsensor
Thesensorcanbesettoonlycomeonatacertainluxlevel.WhensettoDisable,theluminairewillswitchonwhenmotion
isdetectedregardlessofambientlightlevel.Notethatthedaylightsensorisactiveonlywhenlamptotallyswitchesoff.

S10
S11
S12
Daylight
sensor
On
On
On
Disable
-
On
-
200lx
On
-
-
100lx
-
-
-
50lx

DETECTIONDIAGRAM






















Ceiling
Floor
Upto
15m
Upto16m
WARRANTY
This product has a warranty of 5 years from date of purchase. Failure to install in accordance with
the current edition of the IEE Wiring Regulations, improper use, or removal of the batch codes will
invalidate the warranty. If this product should fail within its warranty period it should be returned to
the place of purchase for a free of charge replacement. ML Accessories does not accept responsibility
for any installation costs associated with the replacement product. Your statutory rights are not
affected. ML Accessories reserve the right to alter product specification without prior notice.