Kobelt 7171 Instruction Manual

Kobelt Manufacturing Co. Ltd.
7171 Full Follow Up (FFU) Control Lever
Owner’s Operation, Installation &
Maintenance Manual
March 2019

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 2 of 16
NOTES:
RECORD DATA BEFORE INSTALLATION FOR FUTURE REFERENCE
Model #:
Serial #:
Date of Purchase:
Date of Installation:

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 3 of 16
TABLE OF CONTENTS
1Introduction ............................................................................................................ 4
1.1 Contact .................................................................................................................... 4
1.2 Safety....................................................................................................................... 4
2Product Description ................................................................................................. 6
2.1 Technical Data ......................................................................................................... 6
3Installation .............................................................................................................. 7
3.1 Mechanical .............................................................................................................. 7
3.2 Electrical .................................................................................................................. 7
4Commissioning ...................................................................................................... 11
4.1 Electrical Check...................................................................................................... 11
4.2 Functional Test ...................................................................................................... 11
5Operation.............................................................................................................. 12
6Maintenance ......................................................................................................... 13
6.1 Preventative Maintenance..................................................................................... 13
6.2 Recommended Spare Parts.................................................................................... 13
7Troubleshooting .................................................................................................... 14
8Warranty............................................................................................................... 15

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 4 of 16
1INTRODUCTION
1.1 CONTACT
Kobelt Manufacturing Co. Ltd.
8238 129th Street
Surrey, British Columbia
Canada, V3W 0A6
Sales Tel:
Fax:
Email:
Website:
+1-604-572-3935
+1-604-590-8313
sales@kobelt.com
www.kobelt.com
This document is intended to clearly present comprehensive product data and provide
technical information to assist the end user in design applications. Kobelt reserves the right,
without notice, to change the design, or construction, of any products and to discontinue or
limit distribution of any products. Kobelt also reserves the right to change, or update, without
notice, any technical information contained within this document.
Kobelt recommends that customers visit our website to check for updates to this Manual.
Once a product has been selected for use, it should be tested by the user to ensure proper
function in all possible applications. For further instructions, please contact our distributors or
visit our website.
1.2 SAFETY
1.2.1 Safety Alerts
Throughout this manual, the following symbols, and their accompanying explanation, are
used to alert the user to special instructions concerning a service or operation that may be
hazardous if performed incorrectly or carelessly. The associated risk levels are stated below.
This symbol indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury.
This symbol indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
This symbol indicates a hazardous situation, which if not avoided,
could result in minor or moderate injury.
This symbol informs the reader of events not related to personal
injury but which there is a risk of damage to property or equipment.
This symbol informs the reader of safety-related instructions or
procedures.

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 5 of 16
1.2.2 Notice to Installer
Disregarding the following safety measures can result in an accident causing severe injury to
personnel and damage to material assets.
•Only use the product as directed in this manual.
•Never put the product into service if there is evidence of visible damage.
•Never put the product into service before fully completing installation and
commissioning.
•Do not carry out any modifications to the product.
•Only use authentic Kobelt spare parts.
•Observe all local regulations, directives and laws during the installation of this product.
•All installation, commissioning, and maintenance work must only be conducted by
qualified personnel. (For the purpose of this manual, qualified personnel are persons
who are familiar with the assembly, installation, commissioning, and operation of the
product and who have the qualifications necessary for their occupation.)
•Observe all specifications in this manual. If these guidelines are not followed and
damage occurs, the warranty will be voided.
1.2.3 Product Hazards
Disconnect Power: Turn off power at distribution panel before
beginning installation to protect installer from electrical hazards.
Voltage and Current Compatibility: Confirm that the power source
is compatible with the maximum voltage and current ratings of is
product variant. Failure to do so could result in damage or fire.

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 6 of 16
2PRODUCT DESCRIPTION
The Kobelt 7171 Full Follow Up (FFU) Control Lever is used as an input to FFU electronic
steering systems. The operator can maneuver the vessel by moving the lever port or
starboard to adjust its internal potentiometer. The FFU Control Lever can be used for steering
applications, other marine applications, or industrial installations.
The 7171 can be purchased with electrical switches at the far port and starboard extremes to
handle Non-Follow Up (NFU) mode command signals to the on-board control system.
The 7171 is designed for indoor and outdoor installation with a robust die cast bronze and
stainless steel construction to provide a long service life in a harsh marine environment. The
standard configuration contains an elegant polished chrome jog handle and black surface
finish complements vessel control stations. Optionally, the 7171 can be configured to contain
a small wheel in place of the jog handle.
Figure 1: 7171 Overview Diagram
2.1 TECHNICAL DATA
Table 1: 7171 Technical Data
MODEL
7171 SERIES
KOBELT P/N:
7171-P, 7171-PP
7171-B, 7171-SWB
ELECTRICAL SWITCH CONTACTS
--
Form A, NO (Normally
Open) (per direction)
MAX. CONTACT VOLTAGE
--
250 VAC / 32 VDC
MAX. CONTACT CURRENT
--
10 A (per switch contact)
CONTROL POTENTIOMETER
Up to 2x 1kΩ
MAX. POTENTIOMETER POWER
1 W
OPERATING TEMPERATURE
-13°F … 158°F [-25°C … 70°C]
PRODUCT WEIGHT
5 lbs [2.2 kg]

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 7 of 16
3INSTALLATION
3.1 MECHANICAL
Ideally, the Full Follow Up (FFU) Control Lever should be mounted in a central location at each
station on-board the vessel to control steering operation.
•Within 6 feet [1.8 m] of electrical junction box.
•Placed on horizontal or angled dash surface.
•Placed as to protect external electrical cables from damage.
The FFU Control Lever is equipped with (4) four clearance holes for #10 (M5) screws or bolts
through the top surface for direct mounting to the dash. Ensure the unit is securely fastened
to a suitable surface.
3.2 ELECTRICAL
The FFU Control Lever has 6 foot [1.8 m] long 3C/18 cables for external connections. Connect
them to an electrical junction box and the electronic or power hydraulic steering system
interface as required.
The product’s 3C/18 electrical cables contains the following wires and related functions:
Table 2: 7171 Wire Connections –Potentiometer 1
7171 - Potentiometer 1
Wire #
Wire Name
Colour
Gauge
Function
1
POT+
White
18AWG
FFU potentiometer 1 power supply
connection.
2
POT WIPER
Green
18AWG
FFU potentiometer 1 signal connection.
3
POT-
Black
18AWG
FFU potentiometer 1 ground connection.
Table 3: 7171 Wire Connections –Potentiometer 2 (Dual Pot Configurations Only)
7171 - Potentiometer 2
Wire #
Wire Name
Colour
Gauge
Function
1
POT+
White
18AWG
FFU potentiometer 2 power supply
connection.
2
POT WIPER
Green
18AWG
FFU potentiometer 2 signal connection.
3
POT-
Black
18AWG
FFU potentiometer 2 ground connection.

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 8 of 16
Table 4: 7171 Wire Connections - Switches (‘B’ Configurations Only)
7171 - Switches
Wire #
Wire Name
Colour
Gauge
Function
1
SWA-NO
Black
18AWG
Connects to COM when Switch A is
activated.
2
SWB-NO
White
18AWG
Connects to COM when Switch B is
activated.
3
COM-AB
Green
18AWG
COM connection.
The cable penetration locations shown in Figure 2 and the internal wiring connections are
shown in Figure 3. Note that the internal wiring connections may differ depending on the
configuration variant ordered. For example, not all variants contain two potentiometers or
internal switches.
Figure 2: 7171 Cable Penetration Location

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 9 of 16
Figure 3: 7171 Internal Wiring Diagram
Note that the secondary potentiometer and switches may not be
present on all configurations of this product. Refer to product code
key for definition of internal components.
The operating direction of the Potentiometer in relation to the Full Follow Up Control Lever
handle is shown in Figure 4.

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 10 of 16
Figure 4: 7171 Potentiometer Direction Diagram

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 11 of 16
4COMMISSIONING
4.1 ELECTRICAL CHECK
Ensure that the rear cover is installed and secured before powering
on the 7171.
Confirm that the electrical connections to the 7171 have been made correctly and correspond
to the requirements of your system installation.
4.2 FUNCTIONAL TEST
The Functional Test should be carried out while the vessel is still at
dock and before it is taken out to sea after installation has been
completed.
A complete functional test should be performed on the system that the Full Follow Up Control
Lever has been installed within before entering operational use.

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 12 of 16
5OPERATION
The Kobelt 7171 Full Follow Up (FFU) Control Lever contains one or two potentiometers and
optionally a set of switches for each direction of travel. Operating the FFU Control Lever
causes the steering gear to move in the desired direction. When the lever is released it stays
at the set position and does not spring back to centre.
Operating the lever in either Port and Starboard, or Left and Right, directions commands
motion in the system it is controlling.
Figure 5: 7171 Positions of Operation, SWITCH LEFT, FFU LEFT, CENTRE, FFU RIGHT and
SWTICH RIGHT
Ensure that the FFU Jog Lever is set to within a few degrees of the
current rudder angle before switching into FFU mode.
Not doing so will result in immediate movement of the rudder to
the commanded position.

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 13 of 16
6MAINTENANCE
6.1 PREVENTATIVE MAINTENANCE
•Quarterly (4 times per year)
oVisually inspect wire and cable insulation for splits or damage.
oEnsure there is no visible corrosion on the unit.
oConform cable glands are secured to cables.
6.2 RECOMMENDED SPARE PARTS
No spare parts are recommended for this unit.
It is recommended that any required service work on a Kobelt unit
be performed by a factory authorized service representative. Please
contact the nearest Kobelt authorized distributor for assistance.

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 14 of 16
7TROUBLESHOOTING
If you encounter problems with the operation of your product, please refer to the trouble-
shooting suggestions before contacting Kobelt for assistance. If the steps below do not
resolve your issue, please reach out either Kobelt directly or our Dealers in your area.
Table 5: Common Solutions
Problem
(Issue encountered)
Cause
(What it means)
Corrective Action
(What to do)
Full Follow Up Control
Lever action is
reversed.
Wiring is backwards.
Swap the POT+ and POT- output
wires to their respective
potentiometer and system
connections.
Full Follow Up Control
Lever does not move
rudder at all.
The rest of the system
isn’t hooked up correctly.
Check system wiring.
Confirm wiring to Full Follow Up
Control Lever.
Broken potentiometer or
contact.
Use a multi-meter to monitor the
resistance of the wiring between
potentiometer contacts.
Check for normal operation of the
potentiometer by measuring the
connection while moving the Full
Follow Up Control Lever.
Check potentiometer directions.
Replace any damaged
potentiometers.
Wiring is wrong.
Check wiring.
Refer to system design drawing for
proper wiring.

7171 Full Follow Up (FFU) Control Lever Kobelt Manufacturing Co. Ltd.
Rev A MNL_7171 15 of 16
8WARRANTY
Kobelt Manufacturing Co. Ltd. (“Kobelt”) warrants the Products and Parts manufactured by
Kobelt to be free from defects in workmanship or material and that said products are
designed mechanically and functionally to perform to specifications.
This warranty is effective providing:
•The equipment is used within the intended operating conditions and in accordance with
Kobelt recommendations
•The equipment is installed according to equipment diagrams, specifications and
recommendations which Kobelt has provided
This warranty becomes invalid if the factory supplied serial number has been removed or
altered on the product. This warranty does not cover cosmetic damage or damage caused by
an act of God, accident, misuse, abuse, negligence or modification of any part of the product.
This warranty does not cover damage due to improper operation or maintenance, connection
to inappropriate equipment or attempted repair by anyone other than an authorized Kobelt
representative.
Upon identification of a potential issue or defect with a Kobelt Product or Part, the Warranty
Applicant (“Applicant”) must immediately contact Kobelt and describe the issue in writing, by
letter, fax, email or other electronic conveyance. Kobelt will then assess the cause of the
defect and determine warranty applicability and appropriate remediation.
If any part is found to be defective, Kobelt will replace said part FOB the Kobelt factory
provided that any such defective part is returned by the Buyer with freight and applicable
forwarding charges prepaid by the Buyer. Kobelt’s sole obligation to the Applicant will be to
repair or replace the defective part with same or similar product, to a maximum value of the
list price of the product or part. The Kobelt warranty does not cover labour charges, travel or
any other associated expenses.
All Products and Parts manufactured by Kobelt, are subject to a warranty against
manufacturer’s defects in materials or workmanship for a period of two (2) years from the
date of purchase.
Kobelt will be responsible for all Products or Parts sold by Kobelt but manufactured by 3rd
party manufacturing companies. However, these products and parts are subject to applicable
3rd party warranties and may not be the same as the Kobelt warranty.