Kobold DAG-M3F User manual

Operating Instructions
for
Digital Indicator and Controller
for Panel Mounting
Model: DAG-M3F

DAG-M3F
page 2 DAG-M3F K05/0123
We don’t accept warranty and liability claims neither upon this publication nor in
case of improper treatment of the described products.
The document may contain technical inaccuracies and typographical errors. The
content will be revised on a regular basis. These changes will be implemented in
later versions. The described products can be improved and changed at any time
without prior notice.
© Copyright
All rights reserved.
1. Contents
1.Contents ........................................................................................................ 2
2.Note .............................................................................................................. 4
3.Instrument Inspection .................................................................................... 4
4.Regulation Use ............................................................................................. 4
5.Operating Principle ........................................................................................ 5
6.Assembly ...................................................................................................... 6
7.Electrical Connection .................................................................................... 7
8.Function and operation description ................................................................ 9
9.Setting up the device ................................................................................... 11
9.1Switching-on ...................................................................................... 11
9.2Standard parameterisation: (flat operation level) ............................... 11
9.3Programming interlock RUN .............................................................. 15
9.4Extended parameterisation (Professional operation level) ................. 16
10.Reset to factory settings .............................................................................. 34
11.Alarms/Relays ............................................................................................. 35
12.Interfaces RS232 and RS485 ..................................................................... 36
13.Programmer examples ................................................................................ 37
14.Technical Information .................................................................................. 40
15.Order Codes ............................................................................................... 40
16.Dimensions ................................................................................................. 40
17.Safety advices ............................................................................................. 41
18.Error elimination .......................................................................................... 42
19.Disposal ...................................................................................................... 43
20.EU Declaration of Conformance ................................................................. 44

DAG-M3F
DAG-M3F K05/0123 page 3
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: [email protected]
Internet: www.kobold.com

DAG-M3F
page 4 DAG-M3F K05/0123
2. Note
Please read these operating instructions before unpacking and putting the unit into
operation. Follow the instructions precisely as described herein.
The instruction manuals on our website www.kobold.com are always for currently
manufactured version of our products. Due to technical changes, the instruction
manuals available online may not always correspond to the product version you
have purchased. If you need an instruction manual that corresponds to the
purchased product version, you can request it from us free of charge by email
([email protected]) in PDF format, specifying the relevant invoice number and
serial number. If you wish, the operating instructions can also be sent to you by
post in paper form against an applicable postage fee.
Operating instructions, data sheet, approvals and further information via the QR
code on the device or via www.kobold.com
The devices are only to be used, maintained and serviced by persons familiar with
these operating instructions and in accordance with local regulations applying to
Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the
machines fulfil the EC machinery directive.
3. Instrument Inspection
Instruments are inspected before shipping and sent out in perfect condition.
Should damage to a device be visible, we recommend a thorough inspection of the
delivery packaging. In case of damage, please inform your parcel service /
forwarding agent immediately, since they are responsible for damages during
transit.
Scope of delivery:
The standard delivery includes:
Digital Indicator and Controller model: DAG-M3F
4. Regulation Use
Any use of the device, which exceeds the manufacturer’s specification, may
invalidate its warranty. Therefore, any resulting damage is not the responsibility of
the manufacturer. The user assumes all risk for such usage.

DAG-M3F
DAG-M3F K05/0123 page 5
5. Operating Principle
The panel meter DAG-M3F can evaluate pulses in many different ways and show
the result in the 5-digit LED-display. Available options are: frequency coverage
with optional filters, summate of pulses or display values via the time, detection of
a rotational speed or collection of a position via an incremental encoder. The
results can be monitored via alarm conditions and can be displayed onto the
optional switching point.
Furthermore, the results can be freely scaled on an optional analog output and
relayed to a control system. The device can be operated directly by Namur
sensors, 3-wire sensors, switching/slider contacts, incremental encoders (HTL-
/TTL-output) or TTL-signals.
Via the 3 navigation keys on the front, the device can be adjusted onto different kind
of applications and later on different functions of the device can be controlled.
With an individual code, the created parameterisation can be protected against
changes of the user.
Numerous applications can be realised with this device, like e.g. tachometer,
revolution counter, flowmeter, dosing equipment, filling capacity meter, baking
time meter of a baking oven, flying knife, position evaluation, position surveillance,
flow rate surveillance, acoustic discharge measurements and so on. By use of
the integrated, configurable functions like permanent min/max-recording,
averaging, frequency filter, setpoint setting, threshold value recording via alarm
system, 30-points-linearisation, mathematic charging and many more, you
receive an universal applicable modern instrument for your demands in
measuring and control technique.

DAG-M3F
page 6 DAG-M3F K05/0123
6. Assembly
Please read the Safety advice on page 40 before installation and keep this user
manual for future reference
1. After removing the fixing elements, insert the device.
2. Check the seal to make sure it fits securely.
3. Click the fixing elements back into place and tighten the
clamping screws by hand. Then use a screwdriver to tighten
them another half a turn.
CAUTION! The torque should not exceed 0.1 Nm!
The dimension symbols can be exchanged before installation via a
channel on the side!

DAG-M3F
DAG-M3F K05/0123 page 7
7. Electrical Connection
Type DAG-M3F80W0R supply 100-240 VAC 50/60Hz, DC ±10%
Type DAG-M3F70W0R supply 10-40 VDC galv. isolated, 18-30 VAC 50/60Hz
Connection examples:

DAG-M3F
page 8 DAG-M3F K05/0123
Connection examples:

DAG-M3F
DAG-M3F K05/0123 page 9
8. Function and operation description
Operation
The operation is divided into three different levels.
Menu level (delivery status)
The menu level is for the standard settings of the device. Only menu items
which are sufficient to set the device into operation are displayed. To get into
the professional level, run through the menu level and
parameterise
“prof
“ under
menu item
RUN
.
Menu group level (complete function volume)
Suited for complex applications as e.g. linkage of alarms, setpoint treatment,
totaliser function etc. In this level, function groups which allow an extended
parameterisation of the standard settings are availabe. To leave the menu group
level, run through this level and parameterise „uloc„ under menu item RUN.
Parameterisation level:
Parameter deposited in the menu item can here be parameterised. Functions,
that can be changed or adjusted, are always signalised by a flashing of the
display. Settings that are made in the parameterisation level are confirmed with
[P] and thus safed. Pressing the [O]-key („zero-key“) leads to a break-off of the
value input and to a change into the menu level. All adjustments are safed
automatically by the device and it changes into operating mode, if no further key
operation is done within the next 10 seconds.

DAG-M3F
page 10 DAG-M3F K05/0123

DAG-M3F
DAG-M3F K05/0123 page 11
9. Setting up the device
9.1 Switching-on
Once the installation is complete, start the device by applying the voltage supply.
Before, check once again that all electrical connections are correct.
Starting sequence
For 1 second during the switching-on process, the segment test (8 8 8 8 8) is
displayed, followed by an indication of the software type and, after that, also
for 1 second, the software version. After the starting sequence, the device
switches to operation/display mode.
9.2 Standard parameterisation: (flat operation level)
To parameterize the display, press the [P] key in operating mode for 1 second.
The display then changes to the menu level with the first menu item TYPE.

DAG-M3F
page 12 DAG-M3F K05/0123

DAG-M3F
DAG-M3F K05/0123 page 13

DAG-M3F
page 14 DAG-M3F K05/0123

DAG-M3F
DAG-M3F K05/0123 page 15
9.3 Programming interlock RUN

DAG-M3F
page 16 DAG-M3F K05/0123
9.4 Extended parameterisation (Professional operation level)
9.4.1 Signal input parameters

DAG-M3F
DAG-M3F K05/0123 page 17

DAG-M3F
page 18 DAG-M3F K05/0123

DAG-M3F
DAG-M3F K05/0123 page 19

DAG-M3F
page 20 DAG-M3F K05/0123
9.4.2 General device parameters
Table of contents
Other Kobold Measuring Instrument manuals

Kobold
Kobold DAG-A1T User manual

Kobold
Kobold DAG-M1T User manual

Kobold
Kobold MIM Series User manual

Kobold
Kobold MAK User manual

Kobold
Kobold DPM Series User manual

Kobold
Kobold DRG Series User manual

Kobold
Kobold NBK-01 User manual

Kobold
Kobold HPC-S02 User manual

Kobold
Kobold ZOE User manual

Kobold
Kobold AFS-G1 User manual

Kobold
Kobold OMH-15 User manual

Kobold
Kobold KSK User manual

Kobold
Kobold DAG-S45 Series User manual

Kobold
Kobold APS-Z User manual

Kobold
Kobold Heinrichs TSK User manual

Kobold
Kobold DRH Series User manual

Kobold
Kobold DRS Series User manual

Kobold
Kobold DAG-M4T Series User manual

Kobold
Kobold HND-P105 User manual

Kobold
Kobold DRZ series User manual