This manual is for connection with the GPS compass KGC-1.
CAUTION
・ Positional data cannot be displayed. ECI 1 displays only the heading data
in this application.
・ Connection with KGC-1 doesn’t give full functions of ECI 1.
・ As the cable to connect with KGC-1 isn't attached, it is necessary to order
a connectin
cable CW-376-5M.
Please refer to the separate simplified or CD manual for operation.
Connecting the unit
Connect the cable (CW-376-5M) and the attached resistor and diode from DATA4 connector of
KGC-1 processor unit to ECI 1 as shown in the following drawing.
Please refer to an attached sheet for the details of the wiring
KGC-1 processor unit
ECI 1
Rear view
To DATA4
of KGC-1
processor unit
No connection
Green Blue
Red
White
Wires not used including shielding
sheath must be insulated to avoid
electrical damage.
CW-376-5M
DATA4
①Ground (GND)
②Serial output + (TX+)
③Serial output – (TX-)
④Serial input + (RX+)
⑤Serial input - (RX-)
⑥+ 12 V
②
①
③
④
⑤
⑥
(not use)
Resistor ERD25TJ102 (1 KΩ)
Diode HZ5-C1
ECI1.OM.E 0093116902-01