Koper Bear IT 10+5 kW Troubleshooting guide

INSTRUCTIONSFORCONNECTING,OPERATION,ANDMAINTENANCEOFTHESTOVE
Hydro+AirPelletstovesBearIT
USER AND SERVICE MANUAL
BEARITPage1

BEARITPage2
TABLEOFCONTENTS
1.0INTRODUCTION………………………………………………………………………………………………………………. 3
2.0UPDATINGTHEINSTRUCTIONS……………………………………………………………………………………….. 3
3.0PRECAUSTIONSANDSAFETY……………………………………………………………………………………………3
4.0.RESPONSIBILITIESOFTHEMANUFACTURER………………………………………………………………….. 4
4.1.RESPONSIBILITIESOFTHEINSTALLER…………………………………………………………………………….. 4
5.0TECHNICALCHARACTERISTICS………………………………………………………………………………………… 5
5.1ACCESSORIES………………………………………………………………………………………………………………….. 5
5.2ASSEMBLINGTHECONTROLPANEL………………………………………………………………………………… 5
5.3TECHNICALDESCRIPTION……………………………………………………………………………………………….. 5
5.4TECHNICALDATAANDDIMENSIONS………………………………………………………………………………. 6
6.0INSTALLATIONSITEPREPARATION………………………………………………………………………………….. 7
6.1GENERALRULES……………………………………………………………………………………………………………… 7
6.2CONNECTIONOFTHEOUTERAIRPIPE……………………………………………………………………………. 8
6.3EXHAUSTGASSYSTEM……………………………………………………………………………………………………. 8
6.4EXHAUSTGASESANDINSTALLATION……………………………………………………………………………… 8
6.5USABLEPIPES…………………………………………………………………………………………………………………. 8
6.6INSTALLATIONSCHEMES………………………………………………………………………………………………… 9
6.7REARENDOFTHEEXHAUSTGASPIPE…………………………………………………………………………….. 9
6.8CONNECTIONTOTHEELECTRICALPOWERSUPPLY…………………………………………………………. 10
7.0USAGE…............................................................................................................................... 10
7.1IMPORTANTINSTRUCTIONS……………………………………………………………………………………………. 10
7.2SAFETYPRECAUTIONS…………………………………………………………………………………………………….. 11
7.3WARNINGSAFETYMEASURESFORSTAFF………………………………………………………………………. 11
7.4WARNINGSAFETYMEASURESFORTHEUSER…………………………………………………………………. 11
7.5SAFETYGUIDILINESFORIGNITIONANDCLEANINGOFTHESTOVE…………………………………. 12
8.0FUELS……………………………………………………………………………………………………………………………… 13
9.0TECHNICALSPECIFICATIONS…………………………………………………………………………….……………… 13
10.0ELECTRONICCOMPONENTSSCHEME………………………………………………………….………………… 14
11.0EXPLANATIONOFTHEELECTRONICCONTROLPANEL………............................................... 15
12.0HYDRAULICINSTALLATION…………………………………………………………….……………………………… 25
13.0PELLETS…………………………………………………………………………………………………………………………. 29
13.1STORAGEOFPELLETS.…………………………………………………………………………………………………… 29
13.2POURINGTHEPELLETS………………………………………………………………………………………………….. 29
14.0CLEANINGANDMAINTENANCE…………………………………………………………………………………….. 30
14.1CLEANINGANDMAINTENANCEOFTHEEXHAUSTPIPE…………………………………………………. 30
14.2CLEANINGANDMAINTENANCEOFTHESTOVE…………………………………………………………….. 30
14.3PERIODICALCLEANING…………………………………………………………………………………………………. 30
14.4GENERALCLEANING……………………………………………………………………………………………………… 31
15.0POSTSALESUPPORT……………………………………………………………………………………………………… 32
16.0FAILURES‐CAUSES–SOLUTIONS…………………………………………………………………………………. 33
17.0WARRANTYTERMSANDCONDITIONS………………………………………………………………………….. 36

BEARITPage3
1.0.INTRODUCTION
Dearbuyer,wethankyouforchoosingthisproduct.
ThisproductismadeinaccordancewiththesafetyrequirementsspecifiedbytherelevantEuropean
directives.Thismanualisintendedtoowners,installers,usersandmaintenancepersonnelofthisproduct
andisanintegralpartoftheproduct.Ifthereareanydoubtsregardingthecontentsofthismanualorofany
explanationpleasecontactmanufactureroranauthorisedservicecentre.Noprintingtranslationor
reproducingofthismanualisallowedwithoutthepermissionofKOPER.Thetechnicalinformation,
illustrationandspecificationincludedinthismanualmaynotbedisclosed.
Donotoperatetheapplianceifanyoftheinstructionprovidedinthemanualarenotunderstood.
KOPERreservestherighttomodifythetechnicaland/orfunctionalspecificationofthestoveatanytime
withoutpriornote.Byusingthisinstructionmanualyouwilllearnhowtouseyourpelletburningstove
roperly;pleasereaditcarefullybeforeuse.p
Thisproductismanufacturedinaccordancetothefollowingdirectivesandstandards:
Directive89/106/EEC–Approximationofthelaws,regulationandadministrativeprovisionsofthemember
statesrelatingtoconstructionproducts.
Directive2004/108/EC–Approximationofthelawsofthememberstatesrelatedtoelectromagnetic
compatibility.
Directive2006/95/EC–Electricalequipmentdesignedforusewithincertainvoltagelimits.Directive
89/391/EEC–Introductionofmeasurestoencourageimprovementsinthesafetyandhealthoftheworkers
atwork.
Directive85/374/EEC–Approximationofthelaws,regulationsandadministrativeprovisionsofthemembers
statesconcerningliabilityfordefectiveproducts.
Directive1999/374/EC–Radioequipmentandtelecommunicationterminalequipmentandthemutual
recognitionoftheirconformity.
StandardEN14785/2006Residentialspaceheatingappliancesfiredbywoodpellets–Requirementsandtest
methods.
2.0.UPDATINGTHEINSTRUCTIONS
Thismanualreflectsaworkofartatthemomentwhenthestovewasplacedonthemarket.Therefore,we
doesnottakeintoaccountthestovesthatarealreadyonthemarketwiththeappropriatetechnical
documentationandconsidersthemasdefectiveorinadequateafteranykindofmodification,adaptationor
applicationofnewtechnologiestonewlyproducedmachines.
Thecontentsofthismanualshouldbecarefullyreadandstudied.Itisnecessarytostrictlyfollowallthe
instructionsgiveninthismanual.Allinformationcontainedinthismanualisnecessaryforproperconnection,
use,andmaintenanceofyourstove.
Therefore,thismanualhastobecarefullystoredforthenecessaryinstructionsintheeventofanyproblems
orconcerns.
Ifthestoveisgivenorsoldtoanotherperson,thenewownermustalsobegiventhisinstructionsmanual.
Ifyouhavelostyourmanual,wecanprovideyouwithanewone.
3.0.PRECAUTIONSANDSAFETY
Thecombined(hydro+air)pelletstovesaredesignedtoprovidemaximumsafetyandeasyofoperation.
Howeveritisnecessarytoobservethefollowingsafetyguidelinestoensureanaccident‐freeoperation.
1. Itisrecommendedthattheauthorizedmaintenancestaffshouldmakesurenottoleavebarepartsof
thewiresnotcompletelyinsertedintotheconnectors,sothatnolivepartsofthewiresmaycontactother
bjects.o
2. Theinstallationshouldbeperformedbyspeciallytrainedstaffauthorizedbythemanufacturer;afterits
completion,thestaffisobligedtogivetotheenduserastatementwhichstatesthatthepelletstoves
connectedaccordingtoallapplicablestandardsandthatthestafftakesoverthecompleteresponsibilityfor
itsinstallation.
3. Itisimportanttoobserveallapplicablenationallawsofthecountrywheretheproductistobeinstalled.
4. Themanufacturerdoesnotbearanyresponsibilityiftheabovestatedobligationsarenotobserved.
5. TheInstructionmanualisoneinseparablepartoftheproduct.IncasetheInstructionmanualismissing

BEARITPage4
o
rlost,theenduserscouldhaveitprovidedbytheseller.
6. Thispelletstoveshouldbeusedonlyforthepurposeitisintendedfor.
7. Themanufacturerdoesnothaveanyresponsibilityfordamagesmadebypeople,animalsorobjects
ausedduetoinstallationerrorsorimproperuse.c
8. Afterremovingthepackaging,theusershouldcheckwhetherallthepartsareinplaceandifanyparts
missing,theusershouldhavethesellerprovidethemissingparts.
9. Onlyoriginalpartsmustbeusedforreplacementoffaultyones.Pleasereferonlytoauthorizedservice
gentsholdingcertificateformaintenanceofequipment.a
10. Forproperoperationoftheproduct,itshouldbeservicedonceafterconsumptionof1800kgcertified
pelletsoronceayear.Theserviceshouldbeperformedbyauthorizedstaff.
Forsafetypurposes,thefollowingmustbestrictlyobserved:
Thepelletstoveisnottobeoperatedbychildrenordisabledpersons.
Itisforbiddentoinstalltheproductinatoilet,dampspaces,suchaslaundryroom,aswellasto
touchthepelletstovewithwethandsorlegs.Powersupplysocketwithagroundterminal(safetysocket)
shouldprovidetopowertheappliance.
Itisforbiddentochangeorcancelthesafetyprecautionswitchoutanauthorizationbyaauthorized
technician.
Donotpull,tear,burnthecablescomingoutfromtheproductevenifitisoff.
Donotleavethepackagingclosetochildrenordisabledpersons.
Duringthenormaloperationoftheproduct,thedoorshouldbeclosedatalltimes.
Avoiddirectcontactwithhotpartsoftheproduct.
Checkiftherearedifficultieswhileturningtheproductonafteralongperiodofnon‐operation(see
chapter6.0).
Thepelletstoveisdesignedtoworkeveninextremeweatherconditions,however,incaseofstrong
windorfrostyconditions,thesafetysystemsmighttriggeronandshutthepelletstoveoff.Insuchcase,the
usershouldcontacttheauthorizedservice.Itisnotadvisabletodisableorresetthesafetydevicesonthe
user’sdiscretion.
Fireextinguishershouldbeinreachincaseofaccidentaloccurrenceoffireintheexhaustgaspipe.
4.0.RESPONSIBILITIESOFTHEMANUFACTURER
Inissuingtheseinstructions,weacceptnocivilorlegalliability,directorindirect,dueto:
Accidentscausedbynotrespectingthestandardsandspecificationsgiveninthismanual,
Accidentscausedbyimproperhandlingoruseofthestovebytheuser,
Accidentsresultingfrommodificationsandrepairs,whichwerenotapprovedbyus,
Poormaintenance,
Unforeseenevents,
Accidentsresultingfromtheuseofsparepartsthatwerenotoriginalornotintendedforthesemodelsof
stoves.
Responsibilityforconnectingisfullyassumedbytheinstaller‐contractor.
4.1.RESPONSIBILITIESOFTHEINSTALLER
Installer'sresponsibilityistodoallthetestsofthefluepipeline,airsupply,andallthethingsthatare
necessaryforconnecting(installing)yourstove.
Installer'sresponsibilityistoadjustthestovetolocalregulationswhichapplywherethestoveisconnected
(installed).
Theuseofthestovemustbeinaccordancewiththeinstructionsforuseandmaintenance,aswellaswithall
thesecuritystandardsthataregivenbythelocalregulationsthatapplywherethestoveisconnected
(installed).
Theinstallerhastocheck:

‐ Thetypeofstovetobeconnected,
‐ Whethertheroomcorrespondstothestovewherethestovewillbeinstalled,whichisexpressedasthe
minimumsizerequiredforinstallation,setforthbythemanufacturerofthestove,
‐ Heatgenerator
‐ Manufacturer’sinstructionsregardingtherequirementsofsmokeremovalsystems(ductsandpipesfor
smokeexhaust),
‐ innercrosssectionofthechimney,thematerialoutofwhichthechimneyismade,uniformcross
section,
‐ Thattherearenodisturbancesandobstaclesinthechimney,
‐ Heightandverticalextensionofthechimney,
‐ Altitudeattheplaceofconnectingthestove,
‐ Theexistenceandsuitabilityoftheprotectivecoverforthechimneythatisresistanttothewind,
‐ Thepossibilityofsecuringtheexternalairsupplyandthesizeofthenecessaryopenings,
‐ Simultaneoususeofstovethatneedstobeconnectedwithotherequipmentthatalreadyexistsatthat
place.Iftheresultsofallchecksarepositive,thenwecanproceedwithconnectingthestove.Makesureyou
followtheinstructionsofthemanufacturerofthestove,aswellasthestandardsforfireprotectionandthe
safetystandardsprovided.
Whenyouarefinishedconnecting,thestovehastobeturnedonintrialmodeforatleast30minutestotest
ifthestoveisworkingproperly.
Whentheinstallationandimportantdetailsarecompleted,theinstallermustprovidetheclientthe
following:
‐ Instructionsforuseandmaintenanceissuedbythemanufacturerofthestove(ifsuchinstructionsare
notprovidedwiththestove),
‐ Thedocumentationnecessarytocomplywiththeexistingstandards.
5.0.TECHNICALCHARACTERISTICS
5.1Accessories
B
eforetheinitialinstallationofthepelletstove,youshouldcheckwhetherallaccessoriesareinplace:
Remotecontroller(ifitsprovided)
Controlpanel+screwsforitsmounting(inthereservoirforpellets)
Powercordwithcable
Documentation(warranty,instructionmanual,service)
Important:Readcarefullythewholedocumentationandkeepitattentively.
5.2Assemblingthecontrolpanel
Whenyoutakethepelletstoveoutfromitspackaging,inthe
reservoirforpelletsyouwillfindthecontrolpanel(2)wrapped
inafoilandM5screws(3)mountedonbacksideoftop,which
reusedforitsassembling
a
(1).TaketheM5screwsoutandattachthepaneltothecover.
Important:Whenconnectingthepanel,becarefulnottocut
thecable
5.3Technicaldescription
TheMODELSisdesignedforheatingresidenceorofficespacestobeconnectedonsystemforcentral
heating,atthesametimecontributingtothemorepleasantambience.
BEARITPage5
Theboilerofthepelletstoveismadeofspecialmetalsheet,aswellasasupportingstructurewhichiscoated
ithhightemperaturepaint.Theburnerandpellettransporteraremadefromcastiron.
w

Thecombustionchamberhasadoorwithceramicglasswhichisheatresistantatatemperatureofupto
700oC.Bythissolutionwewantedyoutoseethefireinsidethechamber,atthesametimeavoidingcontact
withthedangeroussparklesandappearanceofsmoke.Thedoorishermeticallyclosed.
A–CONTROLPANEL
B–PELLETTANKANDCOVER
C–COVERFORCLEANINGOFTURBOLATORS
D–EXCHANGEROFHOTAIRWITHFAN
E–DOOR
F–CERAMICGLASS
G–HANDLE
H–ASHCOMPARATMNET
J–BURNER
K–OPENINGCOVERFORGENERALCLEANING
5.4Technicaldataanddimensions
BEARITPage6
Modelofthepelletstove:
BearIT
10+5kW
BearIT
12+5kW
BearIT
15+5kW
BearIT
17+5kW
BearIT
20+5kW
BearIT
25+5kW
Height(C)mm105010501150 1150 1250 1250
Width(A)mm660660660 660 660 660
Depth(B)mm660660660 660 660 660
Weightkg195205211 216 230 235
Distanceforexhaustpipe(D,E) mm 295,110 295,110 295,110 295,110 295,110 295,110
Distanceforcoolwaterpipe
(G,H) mm 355,145 355,145 355,145 355,145 355,145 355,145
Distanceforhotwaterpipe(F,J) mm 890,60 890,60 990,60 990,60 1090,60 1090,60
Diameterofexhaustgaspipe(K)mm808080 80 80 80
Heatingvolume(*)min‐maxm290‐120102‐136 120‐160 132‐176 150‐200 180‐240
Nominalthermalpower(Ptn)kW151720 22 25 30
Waterheatingoutput kW 10 12 15 17 20 25
Heatoutputtospace kW 5 5 5 5 5 5
Reducedthermalpower(Ptr)kW666 6 6 6
Max.consumptionperhourkg/h2.12.63.1 3.4 4.2 5,2

Min.consumptionperhourkg/h1.21.21.2 1.2 1.2 1.2
Reservoircapacitykg202025 25 30 30
Autonomyatnominalpowerh9.57.78.1 7.4 5.7 8
Autonomyatreducedpowerh16.616.620.8 20.8 25 25
Energyefficiency%939393 93 93 93
Workingpressure bar 1.8 1.8 1.8 1.8 1.8 1.8
Maximumallowedpressure bar 3 3 3 3 3 3
NominalelectricalpowerW340340340 340 340 340
NominalvoltageV230230230 230 230 230
NominalfrequencyHz505050 50 50 50
Theabovetableismadeonthebasisoftestsconductedusingwoodenpelletswithcaloricpowerof18220
j/kg(equalto4350Kcal/kg) K
*)Thesevaluesdependontheplaceofinstallation. (
Theabovevaluesareindicative,notobligatory.Themanufacturerretainshisrighttochangethevaluesin
everymomentinordertoimprovetheperformanceoftheproduct.
6.0.INSTALLATIONSITEPREPARATION
.1.Generalrules
BEARITPage7
6
Knowingthattheproperassemblyisveryimportant,aswellastheproperconnectionoftheexhaustgas
systemandthatthepossibleerrorsmadeduringtheassemblyarenotcoveredbythewarrantyof
MANUFACTURER,ourcompanyadvicestheinstallationtobemadeafterthefollowingchecks:
‐
Minimumvolumeofthespacewherethepelletstoveisinstalled(avoidspacessmallerthan40m3);
‐ Providegoodairflow;
‐ Observeallthenorms;
‐ Properoperationoftheexhaustgassystem;
oushouldalsoobservethefollowinglegalnormative: Y
‐ Bansoninstallation
‐
Therighttooccupyaspace
Itisnotallowedaninstallationofthepelletstoveinbedrooms,toilets,andinspaceswherealreadyexists
anotherheatingbodywithoutsufficientairintake(pelletstove,pelletstoveetc.).Itisnotallowedthe
nstallationofthepelletstoveinspacescontainingexplosivematerials. i
Theinstallationofthepelletstoveshouldbemadeinaccordancetoallpracticalknowledge.Thespace
aroundthepelletstoveshouldbemadeofstone,cementorotherfireproofmaterial.Thepelletstove
generatesheataroundtheburner.Therefore,youshouldavoidcontactofflammablematerialswiththe
burner(alcohol,paper,plastics…)

BEARITPage8
Minimal distance from the flammable materials is 200 mm except dimension explained on picture:
A = 200 mm , B = 200 mm , C = 100 mm
‐ Ifthefloorismadeofflammablematerial(parquet...)itshouldbeadequatelyisolated.
‐ Themetalpipesintendedforthegasexhaustshouldbeatadistanceof1,5mfromflammable
materials.
‐ Werecommendthatthepelletstoveshouldbeinstalledascloseraspossibletotheexhaustgassystem,
alwayshavingmaximum3+1Tcurvesandmaximum3mofhorizontalflowwithminimalelevationof3‐5%.
Assoonastheplaceofinstallationisdefined,removethecardboardandtheotherprotectivematerialand
checkwhetherthedoorisproperlyclosed.
6.2CONNECTIONOFTHEOUTERAIRPIPE
Forproperoperationandproperdistributionofthetemperature,thepelletstoveshouldhavesufficientair
intakeandtobeplacedonsuitableplace(aspecialholeforairintakecanbemade).
T
heholeforairintakeshouldbe80cm2minimumandthereshouldnotbeanyobstacles.
Theairmaybealsotakenfromanotherroomwhichisconstantlyventilatedandinwhichthereisnoother
pelletstoveorothersystemwhichneedsanairintake.Thatroomcannotbeabedroom,toilet,andanother
spacewherethereisadangeroffire,suchasagarage,basement,andwarehousecontainingflammable
aterials. m
Ifthereisapelletstoveinthesameroomusinggasfromanopensystemoranyothersourceofharmfulgas,
theairintakeshouldbedirectlyfromoutside.
ANEXAMPLEOFCONNECTIONDIRECTLYFROMOUTSIDE
Forthesakeofproperoperationofthepelletstoveadirectconnectionfromoutsideispossible,usingmetal
pipeprovidedwithsiliconsealer.Itisimportantthatthefrontopeningofthepipeisprotectedagainstwind,
waterorother,usingacurveof90oturneddownwards.
Manufacturerdoesnotbearanyresponsibilityiftheaboveindicatedinstructionsarenotobserved.
Forproperplacementoftheairintakeyoushouldobservethefollowingdistances:1,5munderneath,1,5m
horizontally,0,3mfromabovethedoors,windows2,0mfromtheexhaustgassystem.
6.3EXHAUSTGASSYSTEM
Itisalwaysimportanttoknowthatthechimneyisimportantasthepelletstove.
Theinstallationoftheexhaustsystemonchimneyshouldbeperformedbyauthorizedpersons.Theauthorized
personshouldbeguidedbythefollowingdatafornormalworkingofstoveonreduced,maximalandnominal
power,Thisdataisoptimalandusedinlaboratorywhenstovearetested.
DraftofthepelletstovePa12
Massofthecombustedair g/s5.3
6.4EXHAUSTGASESANDINSTALLATION
Theexhaustgassystemoperatesasaresultofdepressionwhichoccursinthecombustionarea.Itisvery
mportantfortheexhaustgassystem,abovemarkedasSIG,tobemadeofcertifiedmaterialsand: i
‐ Tobehermeticallyclosed,meaningthesystemshouldbemadeofspecialpipeswithadequatesilicon
sealer.
‐ Tobeabletooperateunderhighpressureandundertemperaturerangingfrom200‐250oC(pipeswith
hicknessnotlessthan1mmisrecommended).t
Ifthepelletstoveisconnectedtotheexistingsystem,thesystemshouldbecheckedbyanauthorized
person.Thesystemcannotbeinstalledindoors.Periodicalcleaningoftheexhaustgassystemis
recommended.
6.5USABLEPIPES
Thepipesusedfortheexhaustgasesshouldberesistant, smoothfrominside,madeofmetalandtohave
siliconsealer.Thediameterofthepipesupto3mlongshouldbe80mmor100mmforpipeslongerthan3
orover1200mheightabovesealevel. m

Thelengthiscalculatedalongthewholehorizontalandverticallength,countingeachcurveof90oas1mof
ength. l
A
TTENTION
Donotconnectthesystemtotheexistingsystemortotheaspirationsystem.
BEARITPage9
6.6INSTALLATIONSCHEMES(optional)
DANGER!
It is forbidden to install shut‐off valves forthe flow (draft)of air (flap valves that can prevent airflow or
disabledrafts).
ATTENTION!!!
If the ejection path of smoke creates such a bad draft, of a bad flow of air (many curves, improper
completion of the ejection of smoke,constriction,etc.)dischargeofsmokecanbebad,orinasituation
likethissmokedischargingisnotasgoodasitcouldbe.
The smoke ejection system from the stove operates under negativepressure in thestove chamber and
with mild pressure from the smoke drain pipe. It is veryimportant that the smoke extraction system is
hermeticallyclosed(sealed). Thisrequirestheuse of asmooth tube onthe inside. First of all you must
carefullystudythe planandstructureoftheroomwhenthesmokeextractionpipeis set up through the
wallsandroof,sothattheinstallationofpipesisperformedproperlyinaccordancewiththestandardsof
fireprotection.
You should first ensure that the room where the stove is located has enough air for combustion. It is
advisable to periodically perform check so as to ensure that the combustion air comes right uptothe
combustion chamber. The stove operates at 230 V~ 50 Hz. Make sure that the electrical cord is not
underneaththefurnace,tobeawayfromthestove,tobeawayfromhotspots,andnottotouchanysharp
edges that it could interdict. If the stove is electrically overloaded, this can lead to shortening of the
lifetimeoftheelectronicsofthestove.
Never turn off the power supplyby pulling the plugwhen thereis a burning flamein the stove.
This
couldjeopardizetheproperfunctioningofthestove.
6.7REARENDOFTHEEXHAUSTGASPIPE
Therearendoftheexhaustgaspipeisintendedforproperexhaustofthegasesintheatmosphere,its
protectionagainstrain,snoworanyotherobjectsinordertoguaranteeexcellentexhaustofthegasesin
indyconditions,aswell. w
T
herearendoftheexhaustgaspipeshouldmeetthefollowingrequirements:
‐ theinnerpartshouldbethesameasthatofthepelletstove;
‐ theouterpartshouldnotbelessthantwicethantheoneofthepelletstove;
‐ themanufactureshouldprotectthesystemagainstrain,snowandwind;
‐ easydisassemblingforcleaningpurposes;
‐
Possibilityforattractivefinishwhichfitstothebuilding.
Thesystemshouldnothaveobstaclesatadistanceoflessthan10m,suchaswalls,trees.Insuchacasethe
systemshouldend1mabovetheobstacles,andincaseofothersystems,2mfromthem,andineverycase
thesystemshouldbeatleast1abovetheroof.

Dimension and position
Angle Deference Min H of chimney
β A (m) H (m)
< 1.85 0.5 m
15 o
> 1.85 1 m
< 1.50 0.5 m
30 o
> 1.50 1 m
< 1.30 0.5 m
45 o
> 1.30 1 m
< 1.20 0.5 m
60 o
> 1.20 1 m
YES
NO
O
PERATIONALPROBLEMSDUETODEFECTSOFTHESYSTEMCAPACITY
Besidesallinfluencingatmosphereagents,thewindisthemostimportantagentforthesystemoperation.
6.8CONNECTIONTOTHEELECTRICALPOWERSUPPLY
ThestovemusttobeinstalledbyqualifiedpersonnelincompliancewithEN10683.
Allrequiredcablesandconnectorsareputintothepelletstove.Theinstallationisquickandsimple.
Beforeeachassemblingofthesystem,anautomatictestofthesystemisperformedforitsproperoperation.
Dependofsomeconfigurationsomecablesandconnectorscanbechanged.Whenyouturnontheproduct
forthefirsttime,youshoulddothefollowing:Whenyouaresurethattheassemblyisproperlydone,itis
possibletostartinitialturningONthepelletstovethesettingmightbemadeeitherthroughthecontrol
panelorthesoftware.
FornormaloperationofthestoveALLPARAMETERSISSAVEONTHEMOTHERBOARD.
Theproductshouldbeconnectedtotheelectricalpowersupply.Ourpelletstovesaresuppliedwitha
mediumtemperaturepersistentcable.Incaseyouneedtoreplacethecable,callanauthorizedservice
gent.Beforeyouconnecttotheelectricalpowersupply,youshouldcheckthefollowing: a
‐ whetherthecharacteristicsoftheelectricalpowersupplymeettherequirementsindicatedontheplate
‐ whethertheconnectionisproperlygrounded
‐ Thecableshouldnothavetemperaturehigherthan75oC.
Incaseofadirectconnectiontotheelectricalpowersupply,callanauthorizedperson,anelectrician.Ifyou
donotusethepelletstoveforalongertimeperiod,youshoulddisconnectitfromtheelectricalpower
supply.Theconnectionshouldbeeasilyaccessible.
7.0USAGE
7.1SAFETYPRECAUTIONS
BEARIT Page10
Takingintoconsiderationthatthepelletstovedevelopshightemperature,theyoungandadultpersons
shouldbecareful,andespeciallythechildren.Itisforbiddentopourwateroranyotherliquidwhichmight
causetemperatureshock.Donotplaceflammableobjectsnearthepelletstove.

BEARIT Page11
7.2IMPORTANTINSTRUCTIONS
THEFOLLOWINGINSTRUCTIONSAREREQUIREDFORTHESAFETYOFPEOPLE,ANIMALS,AND
PROPERTY.
Wewishtoinformtheinstallerofthestoveonsomeofthegeneralguidelineswhichmustbefollowedfor
properinstallationandforproperstovemounting.Thesestandardsarerequired,butnotcompletely.For
furtherandmoredetailedinformationoneneedstoreadtherestofthisinstructionsmanual.
‐Plugthestoveintoanoutletthatisgrounded
‐Theswitchontherearofthestoveissettoposition1
‐Donotallowchildrenorpetstobenearthestove.
‐Usepelletsonly,nototherfuel.
‐Notifyallusersaboutthepotentialrisksanddangersandteachthemhowtohandletheappliance.
‐Ifthestoveisplacedonawooden floor, thenit is recommended to isolate the pedestal on which it
stands.
Thestoveoperateswithacombustionchamber,whichisinthenegativepressure.Therefore,makesure
thatthesmokeiswellthermallyinsulated.
Whenthestoveisturnedonforthefirsttimethen,duetothestabilizationprocessasmallamount
ofpaint
(notharmfultohealth)thatcoversthestovevaporizes.Itisthereforenecessarytoairthe
roomsothatit
isclearedfromthefumes.
7.3WARNINGSAFETYMEASURESFORSTAFF
MAINTENANCE
Thecontractorswhoworkinmaintenance,inadditiontofollowingallsafetymeasures,must:
‐Alwaysusesafetyequipmentandpersonalprotectiveequipment,
‐Turnoffthepowersupplybeforetheystartworking,
‐Alwaysusetheappropriatetools,
‐Beforetheybegin anyworkonthestovetheyneedtokeepinmindthatitshouldbecoldandthatthe
ashesshouldbecoldaswell.Theyneedtomakesurethehandlesarecoldaswell.
–NEVERTURNTHESTOVEONifthereisjustoneofthesafetydevicesthatisdefective,improperlyset
up
oritdoesnotworkatall.
‐Donotmakemodificationsofanykind,foranyreason,otherthanthosepermittedandexplainedbythe
manufacturerhimself.
‐Alwaysuseoriginalspareparts.Neverwaituntilthecomponentswearoutbeforeyoureplacethem.
Replacing the worn parts or the components of the stove before they stop working contributes to the
preventionofdamage causedbyaccidentsduetosuddenfailure, or breakingof thecomponents,which
canleadtoseriousconsequencesforpeopleand/orpropertylocatedaroundthestove.
‐Cleanthefireboxbeforelightingthestove.
‐Makesurethereisnocondensation.Ifcondensationoccursitshowsthatthereiswaterfromthecooling
smoke.
Werecommendyoufindthepossiblecausestobeabletoestablisharegularandcorrectoperationofthe
stove.
7.4WARNINGSAFETYMEASURESFORTHEUSER
Theplacewherethestoveistobesetup,calledthemountingplace,mustbepreparedbylocal,national,
andEuropeanregulations.
The stove is a “heating machine" and while it is on it has outer surfaces that are very hot or that
achieveveryhightemperatures.
Thisstoveisdesignedtoburnfuelfrompressedwoodmass(apellet withadiameterof6mmwiththe
lengthof30mm,withmaximummoisture8‐9%).

BEARIT Page12
Itisthereforeveryimportanttopayattentiontothefollowingwhenthestoveison:
Donotapproachandtouchtheglassonthedoor,thereisaBURNINGHAZARD
Donotapproachandtouchthesmokedrainpipe,thereisaBURNINGHAZARD
Donotdoanycleanups
Donotopenthedoorbecausethestoveisworkingproperlyonlywhenitissealed
DonotthrowawaytheasheswhenthestoveisON
Childrenandpetsneedtostandawayfromthestove
FOLLOWALLINSTRUCTIONSGIVENINTHISMANUAL
Likewise,theproperuseofbiofuelpelletsmeans:
Onlyusethefuelthatmeetsthemanufacturer'sinstructions,
Alwaysfollowthemaintenanceplanforthestove,
Cleanthestoveeveryday(onlywhenthestoveandtheasharecold),
Do not use the stove in case of any defects or abnormalities, in the case of unusual noise and/or
suspected faults,
Do not spray water on the stove, even when fire fighting,
Donotturnoffthestovebypullingtheplug.Usethebuttonontheboardtoturnoff,
Donottiltthestove,ITMAYBECOMEUNSTABLE,
Donotusethestoveasasupportoraholder.Neverleavethetanklidopen.
DonottouchthedyedpartsofthestovewhileitisON,
Donotusewoodorcoalasafuel,butonlythepelletwiththefollowingcharacteristics:diameterof6‐7
mm,maximumlength30mm,maximummoisturecontent8‐9%,
Donotusethestovetoburnwaste,
Alwaysperformalloperationswithmaximumsecuritymeasures.
7.5SAFETYGUIDILINESFORIGNITIONANDCLEANINGOFTHESTOVE
-
ForturningthestoveONneverusegasoline,keroseneoranyotherflammableliquid.Keepthesetypes
offluidawayfromthestovewhileitisrunning,
-
NeverturnthestoveONiftheglassisdamaged.Donotstriketheglassorthedoorsothattheydo
not
getdamaged,
-
WhilethestoveisON,donotopenthedoortocleantheglass.Cleantheglassonlywhenthestoveis
cold,usingacottonclothorpapertowelandaglasscleaner,
-
Makesurethestoveissecuretopreventanymovement,
-
Makesurethattheashboxisinsertedandthatitisfullyclosed,sothatthedoorsareleaning
properly
onthebox,
-
MakesurethestovedoorisfirmlyclosedwhilethestoveisON,
-
Useavacuumcleanertopulltheashesfromthestoveonlywhenthestoveiscompletelycool,
-
Neveruseabrasivecleanersforcleaningthesurfaceofthestove.
IMPORTANTSAFETYINFORMATION
Themanufacturerisalwaysatyourservicetoprovideyouwithalltheinformationyoumayneed
regarding
thestoveandinstructionsforassemblyandinstallationinyourgeographicalconditions.
Properly
connectingthestove,accordingtotheseinstructions,isveryimportanttopreventthedangerof
fireand
anydefects.
The stove works with a combustion suction pressure. Therefore, make sure that the smoke is well
thermallyinsulated.

BEARIT Page13
DANGER!
Incaseoffireinthesmokeexhaustpipetakeallthepeopleandpetsoutoftheroom,unplugthe
powersupplyusingthepowerswitchinthehouseorremovetheplugfromthewall(plugmustalwaysbe
easilyaccessibleandfreeofobstacles),andimmediatelycallthefiredepartment.
DANGER!
Youcannotuseconventionalfirewood.
DANGER!
Donotusethestovetoburnwaste.
8.0FUELS
TheonlyfuelwhichisallowedforusebytheManufacturerpelletstoveisthewoodenpellets.
Inordertoguaranteecombustionwithoutproblem,thepelletsshouldbekeptinadryplace.We
recommendusageofhighqualitypellets,compactandnotpowder‐like.Informyourselfatyourpellet
vendor,whichpelletsarethebest.Keepthepelletsonadistancefromthepelletstove,notlessthan1,5m
(seechapter5.0).
ATTENTION:Thepelletstoveismanufacturedandtestedonlybyusingcertifiedpellets.Themanufacturer
doesnottakeanyresponsibilityifyouusenon‐certifiedpellets.
9.0TECHNICALSPECIFICATIONS
E
lectricalpowersupply230V,50/50Hz,maximumconsumption13/20mA.
Inputs:Exhaustgastemperatureprobe,Temperatureroomprobe,Temperatureboilerprobe,Differential
pressuresensor(HuboControl),Safetyboilertemperaturethermostat,Safetypellettemperature
hermostat,SafetyPressureswitch,Encoderforcombustionfan,RS232connector. t
Outputs:Combustionfanwithencoder,heatingfan,Igniter,Circulationpump,Augerpelletengine,
CN1Keyboardconnection
Roomspecifications:
O
perativetemperature–from0to40oC,Storagetemperature–from‐10to50oC
Maximumrelativehumidity–95%
INSTALLATION
Allrequiredcablesandconnectorsareputintothepelletstove.Theinstallationisquickandsimple.
Before
eachassemblingofthesystem,anautomatictestofthesystemisperformedforitsproper
operation.
Whenyouturnontheproductforthefirsttime,youshoulddothefollowing:
Whenyouaresurethattheassemblyisproperlydone,itispossibletostartinitialturningONthepellet
stove
thesettingmightbemadeeitherthroughthecontrolpanelorthesoftware.
FornormaloperationofthestoveALLPARAMETERSISSAVEONTHEMOTHERBOARD.

10.0ELECTRONICCOMPONENTSSCHEME
EasyTech.FullisacontrolsystemforpelletstovesavailableintheversionsAirandIdro.Itischaracterisedfor:
installingandusesimplicity
simpleanddirectuser’sfunctions
reliableandflexiblefunctioningsoftwarewithwell‐establishedTiEmmeelettronicatechnology
advancedfunctionsavailableforthebuildertoadapttodifferentstovesandinstallations
Productcomposition:
controlboardwith4fixingpoints,solidandsure
extractableconnectors
exhausttemperatureprobe
roomtemperatureprobe
connectioncablemainboard‐controlpanel
controlpanelwithantistaticcover
Safetyrules
Beforeworkingonthesystemmakefollow:
theaccidentpreventionandroompreventionrules
thenationalinstituterulesagainsttheworkaccidents
thelegalsafetyrules
theseinstructions areonl
y
fortechnical
p
ersonnel onl
y
Conformity declaration
Applied rules: EN 60730-1 50081-1 EN 60730-1 A1 50081-2
This manual is done with care and attention, but the information could be incomplete, not comprehensive or could have mistakes. For this reason
the
design, the information could be modified without advance notice according to he model. t
TiEmme elettronica is not responsible for the incomplete or not correct information
Electrical connections
It is possible to use this control board matching or not an additional module.
BEARIT Page14

BEARIT Page15
PIN Function Technical Specifications
1 L
2 N Voltage Power Supply 230 Vac ± 10% 50/60 Hz
F1= Fuse T5,0 A
3 NN
4 FF Combustion Fan Triac Regulation 0,9 A max
5 NN
6 FF
Output V2 configurable (configuration’s
parameter: P36) Triac Regulation 0,9 A max
7 N
8 F
Output R configurable (configuration’s
parameter: P52) Triac Regulation 1,6 A max
9 N
10 L Auger Pellet Engine Triac Regulation 0,9 A max
11
12 Safety Thermostat Input AT1 Contact ON/OFF Normally
closed
To Bypass if not
13
14 Safety Pressures witch Input AT2 Contact ON/OFF Normally
closed
To Bypass if not
15 Red +
16 Green — Exhaust Gas Temperature Probe Thermocouple K: 500 or 1200 °C max
17
18
Configurable Input IN2 (configuration’s
parameter: P74) NTC 10K @25 °C: 120 °C max
19
20 Boiler Probe NTC 10K @25 °C: 120 °C max
21 +5V
22 GND
23 SEG
Encoder Signal (see parameter A57)
Signal TTL 0 / 5 V
24 GND
25 SEG
Configurable Input IN5 (configuration’s
parameter: P70)
26 GND
27 SEG
30 +5V
Configurable Input IN6 (configuration’s
parameter: P72)
-
28 GND
29 SEG
30 +5V
Pressure Sensor
31 +12V - -
32 F - -
33 COM/N
35 NO/FON
34 NC/FOFF
Output Aux1 configurable (configuration’s
parameter: P44)
Relé 3 A max
36 COM
37 NO
Output Aux2* configurable (configuration’s
parameter: P48) Relé 1 A max, free contact output
38 SEG
39 GND
Configurable Input IN8* (configuration’s
parameter: P71) Contact ON/OFF
40 SEG
43 +5V
Configurable Input IN9* (configuration’s
parameter: P76) Contact ON/OFF
41 GND
42 SEG
44 +V
Encoder Fan Signal*
Signal TTL 0 / 5 V
RS232 RS232 Connector Connection for Programmer, Modem, Computer
RS485 RS485 Connector Connection for keyboard, Key Pro
CN1 - -
*only present in the board with the additional module
NOTE: for the outputs Combustion Fan (pin 3-4), Heating Fan (pin 5-6) and R Output (pin 7-8),
the total maximum
consumption must not exceed 3,5 A.

11.0EXPLANATIONOFTHEELECTRONICCONTROLPANEL
LCDVERSION
DisplayLCD100
Themainframeshows:time and date,
chrono activation,
combustion powerand
recipe,,
functioning state, error code,
main
temperature, main thermostat,
summer/wintermode.
Button Function
P1 Exit Menu/Submenu
P2 Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono
P3 Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data
P4 Enter in Visualizations Menu, Increase
P5 Activation chrono time band
P6 Enter in Visualizations Menu, Decrease
Led Function
D1 Auger ON D9 External Chrono reached
D2 V2 ON Output D10 Lack of pellet
D3 R output ON D11 Local Room Thermostat reached
D4 Aux1 ON Output D12 Sanitary water demand
D5 Aux2 ON Output
DisplayK100
The main frame shows:
time,
chrono activation,
combustion
power, heating power,
functioning state, main
temperature, main thermostat,
Button Function
K1 Exit Menu/Submenu
K2 Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono
K3 Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data
K4 Enter in Visualizations Menu, Increase
K5 Enter in Visualizations Menu, Decrease
Led Function Led Function
Lack of pellet External Chrono reached
Domestic hot water demand Local room Thermostat reached
Winter Summer
BEARIT Page16

BEARIT Page17
DisplayK200
Themainframeshows:
dateandtime,chrono
activation,
combustion power
andrecipes,
functioningstate,
errorcode,main
temperature,
main thermostat
pincipale,
summer/wintermodality
KeysfortheMenuselection:
SystemIgnitionbypressingandholdingfor3seconds AccesstoUserMenu2
AlarmsResetifpressedduring3seconds AccesstoInformationMenu
AccesstoUserMenu1
NavigationKeys:
BacktotheMainFrame ExittheMenuandsavedata
Backtoupperlevel ExittheMenuwithoutsavingdata
ScrollIncreaseofthevalue Scrolltotheleft
ScrollDecreaseofthevalue Scrolltotheright
Led:
TheLedzoneisnotalwaysvisibleinthemainframeofthedisplay.Tomakeitappear/disappear,pressdownon
thedisplay
areacontainingthemaintemperatureorthefunctioningstate.ThevisibleLed’sare:
AugerOn ExternalChronoReached
V2OutputOn Lackofmaterialinthetank
ROutputOn RoomThermostatReached
Aux1OutputOn DomesticHotWaterDemand
Aux2OutputOn
SummerModality WinterModality
TouchScreenCalibration:
TheTouchScreenKeyboardisalreadyfactorycalibrated,butif,inanytime,imprecisionintouchingthescreenstart
to
comeup,anewCalibrationcanbedone.
ToCalibratethescreenfollowtheprocedurebelow:
1.
Turnoffthekeyboard.
2.
Presswithafingeronanypointofthescreenandturnonthekeyboardagain.
3.
Onthescreen,awarningframewillappearsaying“Keeptouchingtoforcescreencalibration”.
4.
Afewsecondslaterasecondwarningframewillappearsaying“Removetouchnow”.
5.
Ifeachofthegivencommandsisnotdonewithinafewseconds,theCalibrationprocedurewon’tstartand
thedisplay
willvisualizethemainframe.
OncethecommandsgivenbytheKeyboardarecorrectlyexecuted,theCalibrationprocedurewillstartand
thefig1willappearonthescreen.
6.
Withastylus,orwithfingers,pressonthecentreofthesymbol“+“locatedintheupperleftcornerofthe
screen
7.
Thekeyboardwillstorethecoordinatesofthepointandwillmovethesymbol“+“tothecentreofthescreen
(Fig.2).
8.
Pressagainonthesymbol“+“,thiswillmovetothelowerrightcornerofthescreen(Fig.3).
9.
Oncepressedthislastpoint,theCalibrationprocedureiscompletedandthedisplaywillvisualizethe
mainframe.
Checknow,pressingonthescreen,ifthekeyboardreactstothecommandsgivenmore
preciselythanbefore.

BEARIT Page18
Alarms
DescriptionSystemStateCode
ErrorSafetyHighVoltage1:signalledalsowiththesystemOffBlockEr01
ErrorSafetyHighVoltage2:signalledonlyiftheCombustionFanisOnBlockEr02
ExtinguishingforexhaustundertemperatureBlockEr03
ExtinguishingforwaterovertemperatureBlockEr04
ExtinguishingforexhaustovertemperatureBlockEr05
PelletThermostatopen(flamereturnfromthebrazier)BlockEr06
Encoderfanerror:noEncodersignal(incaseofP25=1or2)BlockEr07
Encoderfanerror:CombustionFanregulationfailed(incaseofP25=1or2)BlockEr08
Lowwaterpressure(theerrorisnotreportedifthe system isin Off orBlockstate and P1
PumpisOff)BlockEr09
HighwaterpressureBlockEr10
DayandtimenotcorrectduetoprolongedabsenceofpowersupplyBlockEr11
FailedignitionBlockEr12
LackofvoltagesupplyBlockEr15
CommunicationRS485errorBlockEr16
AirflowregulatorerrorBlockEr17
RunoutofpelletBlockEr18
BoilerprobeorBufferprobeopenBlockEr23
ErrorEnginecleaningBrazierBlockEr25
AirFlowsensordamagedBlockEr39
MinimumairflowinCheckUpnot reached(FL20)/Test ’Forced Draught Low’ in Check Up
fail(FL71)BlockEr41
Maximumairflowreached(F40)BlockEr42
OpendoorerrorBlockEr44
AugerEncodererror:noEncodersignal(ifP81=1or2)BlockEr47
AugerEncodererror:augerspeedregulationfailed(ifP81=1or2)BlockEr48
ModuleI/OI2CerrorBlockEr52
Messages
DescriptionCode
Anomalyoftheprobeschecking,duringCheckUpphase.Sond
Roomtemperaturegreaterthan99°C.Hi
Thismessagenotifiesthattheplannedhoursoffunctioning(parameterT67)arereached.Clean
DoorOpen.Port
Themessageappearsifthesystemisturnedoffduring Ignition (after Preload) not manually: thesystem
willstoponlywhenitgoesinRun Mode.Ignitionblock
PeriodicalCleaninginprogress.Cleaningon
NocommunicationbetweenmotherboardandkeyboardLinkError
Visualizations
DisplayDescription
ExhaustT.[°C]103Exhausttemperature
RoomT.[°C]25Localroomtemperature;itisvisibleonlyifA19=1

BEARIT Page19
PufferT.[°C]48PufferTemperature,itisvisibleonlyifP26isseton2,3,4
Pressure[mbar]2100Waterpressure
AirFlux750Airflow;itisvisibleonlyifA24isdifferentfrom5
FanSpeed[rpm]1250Exhaustfanspeed;itisvisibleonlyifP25isdifferentfrom0
Auger[s]1.2Augerworktime;itisvisibleonlyifP81isequalto0
Recipe[nr]2Combustionrecipeset;itisvisibleonlyifP04isgreaterthan1
ProductCode:5100000Productcode
User Menu 1
Power
Inthismenuispossibletomodifythecombustionpowerofthesystem.Itcanbesetin
modalityautomaticormanual.Inthefirstcasethesystemchoosesthecombustionpower.In
thesecondcasetheuserselectsthedesiredpower.
Ontheleftsideofthedisplayaresignalledthecombustionmodality(A=automatic
combustion,M=manualcombustion)andtheworkingpowerofthesystem.
Recipe
Menutoselectthecombustionrecipe.Themaximumvalueisthenumberofrecipesvisibleto
theuser(parameterP04).IfP04=1theMenuisn’tvisible.
AugerCalibration
ItallowstomodifythevaluesetinfirmofAuger’sspeedorOntimes.Thevaluesareinthe
range–7÷7.Thefirm’svalueis0
Combustion
Management
FanCalibration
ItallowstomodifythevaluesetinfirmofCombustionFan’sspeed.Thevaluesareintherange
–7÷7.Thefirm’svalueis0.
Boilerthermostat
Menutochangethevalueoftheboilerthermostat.Theminimumandthemaximumvalue
canbeprogrammedbysettingthethermostatsrespectivelyTh26andTh27.
Bufferthermostat
MenutochangethevalueoftheBufferThermostat(Th58);itisvisibleonlyifP26=2,3,4.
Theminimumandthemaximumvaluecanbeprogrammedbysettingthermostats
respectivelyTh51andTh52.
HeatingPower
Itallowstochangethepowerofthefanheating.Thismenuisvisibleonlybysettinganoutput
configurableto6andA04=0.Youcansetthemanagementoftheheatingsystemin
automaticormanualmode.
Heating Description
0FF
Heatingfanisstopped(itispossibleonlyifP95=0)
1
–
Poweruser
number
Powerisadjustedmanuallyfrom1tothemaximumnumberofpoweruser
(parameterP03)
Auto
Powerisadjustedautomaticallyaccordingtothevalueofthe
parameterP06
RoomThermostat
ThisMenuallowsmodifyingtheLocalRoomThermostat’svalue.Itisvisibleonlyiftheambient
probeisselect.
Heating
Management
Summer‐Winter
MenuthatallowstheselectionSummer‐Winter

BEARIT Page20
RemoteControl
ThisMenuallowsenablingordisablingtheremotecontrol.
Buttons
Button1activatesextinguishing
Button2activatesignition
Button3or4decrease/increasethecombustionpower
LearningCode
OntheRemoteController:
• Openthebatterycaseslidingthecovertowardsright
• modifytheconfigurationoftheinternaldip‐switchandclose
OntheControlBoard:
• switchoffthepowersupply
switchonthepowersupplypressingatthesametimeonebuttonontheremotecontrol
waitingabout5secondsuntilanacousticsignalisemittedconfirmingthecodelearned
ManualLoadTheprocedureactivatesthepelletmanualloadingwithactivationincontinuemodalityofthe
Augerengine.Theloadingisstoppedautomaticallyafter600seconds.Thesystemmustbe
OFFforthefunctioncanbeactivated.
CleaningRese
t
Menutoresetthe‘SystemMaintenance2’function.ItisvisibleonlyifT67>0.
EnablingThermostat
Itallowstoactivate/deactivatethefunctionRoomThermostat.
RemoteKeyboard
(onlyonremote
keypad;itisonly
visibleifA52>0)
RoomThermostat
Menutochangethevalueoftheroomthermostatofremotekeypad.
ThisMenuallowsselectingtheprogrammingmodalitiesandandtheIgnition/Extinguishing
timeslots
Modality
Itallowsselectingthe desired modality, or
disable all set
programming.
entermodificationmodethroughthekeyP3
orK3
selectthechosenmodality(Daily,Weekly
orWeek
end)
enable/disablechronomodalitythroughthe
keysP2orK2
savethesettingsthroughthekeysP3orK3
Chrono
(forLCD100and
K100
Keyboards)
Programming
Thesystemincludesthreetypeofprogramming:Daily,
Weekly,Weekend.Afterselectingthedesiredkindof
programming:
‐selecttheprogrammingtimethroughthekeysP4/P6
orK4/K5
‐entertheadjustmentmodality(selectedtimewillbe
flashing)throughthekeysP3orK3
‐changethetimeviakeysP4/P6orK4/K5
‐savetheprogrammingwiththekeysP3orK3
‐enable(a“V”isdisplayed)ordisablethetimeslot(a
“V”isnotdisplayed”)bypressingthekeysP5orK2
Daily
Selectthedayoftheweektoprogramandsetthe
ignitionandextinguishingtimes.
Programsaroundmidnight
This manual suits for next models
9
Table of contents
Popular Stove manuals by other brands

Unical
Unical .it 7 Installation and maintenance instructions

Harvia
Harvia M3 SL Additional instructions

Continental Refrigerator
Continental Refrigerator CEFS22H-LOWC Installation and operation manual

Extraflame
Extraflame SHARON PLUS user manual

Ferlux
Ferlux DENIA manual

Euroheat
Euroheat WIKING MIRO Range installation instructions

New Buck Corporation
New Buck Corporation 74 manual

VENMA
VENMA COMFORT Series operating & maintenance manual

Comfort Glow
Comfort Glow S26PT OWNER'S OPERATION AND INSTALLATION MANUAL

Dimplex
Dimplex DS4411 owner's manual

Woodstock Soapstone
Woodstock Soapstone KEYSTONE 204 owner's manual

AGA
AGA LUDLOW ECG INSTALLATION, SERVICING AND USER OPERATING INSTRUCTIONS