DATA (G, Rx, Tx)Terminal Block
Connectors
Connect to a serial data source (for example, a room controller) or to an acceptor for
tunneling control commands via HDBaseT.
Remote 5-pin Terminal Block
Connector
Connect to contact closure switches (by momentary contact between the desired pin and
G pin).
INPUT –Short press—toggles between the PC, DP++ and HDMI inputs; Long press—
adjusts the VGA phase shift.
STEP-IN –activate the STEP-IN function.
VOL UP, VOL DOWN –Short press—increases/decreases the volume by one step;
Long press—Increases/decreases the volume from 0% to 100%/100% to 10% in 10
seconds.
Short press –Power cycle (reboot) the device.
Long press –Reset IP settings to factory default values.
Connect to a PC to perform firmware upgrade.
Connect to an HDBaseT receiver (for example, TP-780Rxr, TP-588D or TP-580Rxr) and
provide or accept power (bidirectional PoE).
Lights green when there is a valid HDBT link.
48V DC Power Terminal Block
Connector
Connect to the Kramer power adapter.
The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc.
Step 3: Mount DIP-22
Install DIP-22 using one of the following methods:
•Attach the rubber feet and place the unit on a flat surface.
•Fasten a bracket (included) on each side of the unit and attach it to a flat surface
(see www.kramerav.com/downloads/DIP-22).
•Mount the unit in a rack using the recommended rack adapter
(see www.kramerav.com/product/DIP-22).
•Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
•Avoid uneven mechanical loading.
•Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
•Reliable earthing of rack-mounted equipment should be maintained.
•Maximum mounting height for the device is 2 meters.
Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your DIP-22.
To achieve specified extension distances, use the recommended Kramer cables available at www.kramerav.com/product/DIP-22.
Using third-party cables may cause damage!
Step 5: Connect power
Connect the power cord to DIP-22 and plug it into the mains electricity.
Safety Instructions (See www.kramerav.com for updated safety information)
Caution:
•For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•There are no operator serviceable parts inside the unit.
Warning:
•Use only the power cord that is supplied with the unit.
•Disconnect the power and unplug the unit from the wall before installing.